OCTANORM â Doppelform<br />

OCTANORM â Doubleform<br />

Auskragung<br />

Cantilever<br />

KragarmloÈsungen m<strong>it</strong> DFT 250<br />

StuÈtzen untergestellt<br />

Cantilever solutions w<strong>it</strong>h DFT 250<br />

supported by uprights<br />

Irrtum und technische A È nderungen vorbehalten / Errors and technical modifications reserved<br />

StandardstuÈtze Standard upright<br />

untergestellte StuÈtze<br />

supporting upright<br />

Kupplungsstutzen<br />

Gewinde M 10<br />

Coupling stud<br />

Thread M 10<br />

dazwischengehaÈngtes Feld<br />

Field suspended inbetween<br />

DFS 2510<br />

DFS 2510/80 altern.)<br />

untergestellte StuÈtze<br />

supporting upright<br />

Auskragender HaupttraÈger DFT 250<br />

Cantilever main supporting beam DFT 250<br />

DFT 1000<br />

ZwischentraÈger DFT 250<br />

Intermediate supporting beam<br />

Wichtig!<br />

Kragarmdurchbiegung zulaÈssiger Wert ¬ 1/200 L KR<br />

L KR =LaÈnge Kragarm<br />

Important:<br />

Perm<strong>it</strong>ted sagging of the cantilever ¬ 1/200 L KR<br />

L KR = Length of the cantilever<br />

Hinweis:<br />

Kragarme fuÈr groÈûere Nutzlasten als 350 kg/m 2 nicht geeignet, da die Durchbiegungen zu groû werden<br />

und keine ausreichenden Gegengewichte aus Eigengewicht aufzubringen sind!<br />

FuÈr 350 kg/m 2 einse<strong>it</strong>iger Kragarm verlangt min. Eigen-Gegengewicht von FeldgroÈûe 4x4 m.<br />

Zweise<strong>it</strong>ige Kragarme: noch groÈûere Durchbiegung!<br />

Information:<br />

The cantilevers are not f<strong>it</strong> for live loads higher than 350 kg/m 2 as the sagging would be too large and the<br />

dead weight is not sufficient to provide the necessary counterweight.<br />

For 350 kg/m 2 the cantilever on one side requires a dead weight corresponding to an area of 4 x 4 m.<br />

Cantilevers on both sides: even larger sagging!<br />

Erstellungs-Datum November 1987<br />

Technische Information<br />

Date of issue November 1987 DF-11.2