OCTANORM â STRUKTUR<br />

OCTANORM â STRUKTUR<br />

STRUKTUR-Halbachse<br />

STRUKTUR Half Axis<br />

STRUKTUR-Halbachse ¹495 mmª: Durchbiegung bei Kragarm-Bauweise<br />

STRUKTUR half axis ª495 mmª: Sagging of cantilever constructions<br />

Irrtum und technische A È nderungen vorbehalten / Errors and technical modifications reserved<br />

ZulaÈssige Bauweise, ohne Fremdlasten:<br />

Spannwe<strong>it</strong>e max. zwischen den StuÈtzen 4x4m<br />

KragarmlaÈngemax.=1m<br />

Permissible structures, w<strong>it</strong>hout working load:<br />

max. span width between uprights: 4x4m<br />

max. cantilever length: 1 m<br />

*Eigengewicht STRUKTUR - Halbachse<br />

*own weight of STRUKTUR half axis<br />

Durchbiegungswerte in mm Sagging in mm<br />

Baubeispiele Examples of construction<br />

Meûpunkte<br />

Measured pos<strong>it</strong>ions<br />

Grundregeln:<br />

¹Bei STRUKTUR Halbachsensystemª<br />

statische Nutzbarke<strong>it</strong> nur 50%<br />

± Die FeldgroÈûe zwischen den StuÈtzen muû das 1 1/2 fache Gewicht vom<br />

Kragarm haben.<br />

± Nur fuÈr die gezeigten Baubeispiele gilt die vorgeschlagene Verteilung Zugund<br />

Druckverbinder zur Minimierung der Kragarmbiegung. Bei VergroÈûerung<br />

des Zentrumgewichtes muû die Pos<strong>it</strong>ionierung der Zug- und<br />

Druckverbinder nach dem herkoÈmmlichen Verteilerprinzip vorgenommen<br />

werden bzw. nach AbklaÈrung m<strong>it</strong> dem Statiker<br />

Basic rules:<br />

À Á Â Ã<br />

A 10 5 6<br />

B 12 8<br />

C 5<br />

Z 5 5<br />

ªW<strong>it</strong>h STRUKTUR half axisª the<br />

static loading is decreased to 50%<br />

± The area inbetween the uprights must have 1.5 times the weight of the cantilever<br />

area<br />

± The suggested distribution of tension and pressure connectors is only applicable<br />

for the examples described on this page in order to minimize the cantilever<br />

sagging. In case the weight of the central area can be increased, the<br />

pos<strong>it</strong>ioning of tension and pressure connectors should be executed acc. to<br />

the general principle resp. after having consulted a statics engineer.<br />

Druckverbinder unten<br />

Pressure connectors<br />

inferior line<br />

Druckverbinder unten<br />

Pressure connectors<br />

inferior line<br />

Zugverbinder unten<br />

Tension connectors<br />

inferior line<br />

Zugverbinder unten<br />

Tension connectors<br />

inferior line<br />

unten komplett Druckverbinder<br />

whole inferior line<br />

pressure connectors<br />

unten komplett Druckverbinder<br />

whole inferior line<br />

pressure connectors<br />

1 4<br />

1<br />

0,5<br />

Erstellungs-Datum Dezember 1992<br />

Technische Information<br />

Date of issue December 1992 OS-4.0