<strong>601</strong> Fourth <strong>Avenue</strong> OUTLINE SPECIFICATION<br />

Seattle, Washington<br />

111300 – LOADING DOCK EQUIPMENT<br />

Page 1 of 2<br />

PART 1 - GENERAL<br />

1.1 SECTION REQUIREMENTS<br />

A. Summary:<br />

.1 Dock levelers, dock bumpers, dock door seals, loading lights and associated electrical and<br />

plumbing work.<br />

1.2 SUBMITTALS<br />

A. Product Data and Shop Drawings.<br />

B. Shop Drawings to indicate dimensions of pit and required clearances, details of equipment and<br />

electrical requirements.<br />

1.3 QUALITY ASSURANCE<br />

A. Regulatory Requirements: Comply with applicable requirements of ANSI/ASME MH14.1 for<br />

construction and operation of dock levelers.<br />

1.4 WARRANTY<br />

A. Warranty for Dock Levelers:<br />

.1 Structural Assembly: Ten years.<br />

.2 Hydraulic System: Five years.<br />

PART 2 - PRODUCTS<br />

2.1 MANUFACTURER<br />

A. Use dock equipment manufactured by Kelly Dock Systems or approved alternate.<br />

2.2 EQUIPMENT<br />

A. Dock Levelers (hydraulic): Electric hydraulic type, load capacity 80,000 lbs, 72 x 99 inches length,<br />

automatic 16 inch lip extension.<br />

.1 Provide pit safety strut and electrical outlet for maintenance; toe guards and cross traffic<br />

support for safety.<br />

.2 Self-Forming Pan: Manufacturer's standard prefabricated, self-forming steel form system for<br />

poured-in-place construction of concrete pit.<br />

.3 Night Locks: Manufacturer's standard means to prevent extending lip and lowering ramp<br />

when overhead doors are locked.<br />

.4 Interlock: Leveler will not operate while overhead door is in closed position.<br />

B. Dock Bumpers: Moulded one-piece rubber of uniform size, 4 inches deep x 10 inches wide x 18<br />

inches high.<br />

C. Dock Door Seals:<br />

.1 Seals on three sides with adjustable curtain top curtain, shelter seal of diagonal projection<br />

pads, 12-15 inches wide with 4-6 inches seal beyond dock bumpers, high density<br />

polyurethane foam, continuously bonded to kiln-dried pressurized wood frames and covered<br />

with high-wear waterproof 40 oz. fabric<br />

19 December, 2008 Foster + Partners