Views
3 years ago

198934 Roof Stairs INSTALLATION INSTRUCTIONS.pdf - Westeel

198934 Roof Stairs INSTALLATION INSTRUCTIONS.pdf - Westeel

PLANNING THE LOCATION OF

PLANNING THE LOCATION OF LADDER COMPONENTS (cont.) IF PRESENT, INSIDE LADDERS SHOULD BE CENTERED ON THE INSPECTION HATCH CENTER THE SIDEWALL LADDER ON THE ROOF LADDER, OR ROOF STAIRS, AS MUCH AS POSSIBLE. ON STIFFENED BINS, THE POSITION OF THE SIDEWALL LADDER RELATIVE TO THE UPRIGHTS CAN BE IMPORTANT (SEE BELOW). IT MAY BE NECESSARY TO POSITION THE ROOF RELATIVE TO THE UPRIGHTS WHEN INITIALLY ASSEMBLING TO AVOID INTERFERENCE WITH THE UPRIGHT. If there is a ladder/platform combination, it is necessary to position the consecutive sidewall ladder runs on either side of an upright. The proper side wall bolt holes are illustrated below for a ladder positioned to the left of the upright. The mirror image of these holes can be used if the ladder is on the right side of the upright. LADDER ATTACHMENT POINTS UPRIGHT LOCATION Page 12 PLATFORM ATTACHMENT POINTS

Wall Ladder Assembly Considerations – When mated with a roof stairs, the external ladders, cages and eaves rails should be assembled as per the assembly instructions contained with those products. However, there are a few additional requirements as noted below. 1. For 15’ – 54’ Diameter: Bolt on the single ladder extension rung (234098) when assembling the pass through rails to the top ladder section as shown. The same hardware that is supplied with the ladder package is used. For these bin diameters, the cage assembly remains as per the instructions provided in the ladder installation manual. SINGLE LADDER EXTENSION (234098) Figure 1 For 60’ – 108’ Diameter: Bolt on the double rung ladder extension (234103) as illustrated below. This double rung part is an extension of the ladder. The pass through rails (234505), are raised accordingly. For stability both pass through rails must be secured to the bottom lip of the first roof stair (Figure 4). The support arms (234504) must also be used as described below. For these bin diameters the top safety cage section only must be extended. See the illustration for the difference in the top cage section. 54' 60' 108' 60' 108' Figure 2 Page 13

SealForm BROCHURE.pdf - Westeel
Installation Manual - Stair Lifts 101
198945 Curved Stair INSTALLATION INSTRUCTIONS.pdf - Westeel
198939 Roof Handrail INSTALLATION INSTRUCTIONS.pdf - Westeel
198927 SC Ladder INSTALLATION INSTRUCTIONS.pdf - Westeel
198890 Centurion W INSTALLATION INSTRUCTIONS.pdf - Westeel
198799 C-Ring ZGD INSTALLATION INSTRUCTIONS.pdf - Westeel
198925 WC Ladder INSTALLATION INSTRUCTIONS.pdf - Westeel
198823 SC SealForm INSTALLATION INSTRUCTIONS.pdf - Westeel
198826 WC SealForm INSTALLATION INSTRUCTIONS.pdf - Westeel
198900_R5 - Recycoil INSTALLATION INSTRUCTIONS.pdf - Westeel
198920_R3 - Stand-Ladder INSTALLATION ... - Westeel
WIDE CORR GRAIN BINS - Westeel
198935 Ladder Makeup Packages INSTALLATION ... - Westeel
198941 Axial Fan INSTALLATION INSTRUCTIONS.pdf - Westeel
198824 Commercial Hopper INSTALLATION ... - Westeel
Pneg-1114 - Roof Stair Assembly - GRAIN SYSTEMS INC.
CENTURION-W Manual 198890 Insert - Westeel
Fuel Vault Tank Accessory INSTALLATION ... - Westeel
to download Klan Spiral Stair Installation Instructions [758Kb pdf]
BALUSTRADE INSTALLATION GUIDE - LJ Smith | Stair Systems
LIMITED WARRANTY - Westeel
198943 Inline Fan INSTALLATION INSTRUCTIONS.pdf - Westeel
198937 SSK Stiffened INSTALLATION INSTRUCTIONS.pdf - Westeel
SC Full Floor System INSTALLATION INSTRUCTIONS.pdf - Westeel
198942 High Speed Centrifugal Fan INSTALLATION ... - Westeel
Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair - Fitts