Elec<strong>tr</strong>ic Drives<br />

and Con<strong>tr</strong>ols<br />

<s<strong>tr</strong>ong>Hydraulics</s<strong>tr</strong>ong><br />

Linear Motion and<br />

Assembly Technologies Pneumatics Service<br />

Ex<strong>tr</strong>acted from RE 29151/07.05<br />

Page 2 of 2<br />

See Section 16 for applicable<br />

Issue: 06.06<br />

Preferred/Spotlight part numbers<br />

and unit price.<br />

Technical data<br />

General<br />

Cons<strong>tr</strong>uction<br />

Poppet valve<br />

Actuation<br />

Proportional solenoid with position con<strong>tr</strong>ol and OBE<br />

Connection type Subplate, mounting hole confi guration NG6 (ISO 4401-03-02-0-94)<br />

Mounting position<br />

Optional<br />

Ambient temperature range °C (°F) –20 to +50 (–4 to +122)<br />

Weight kg (lbs.) 2.7 (6.0)<br />

Vibration resistance, test condition Max. 25 g, shaken in 3 dimensions (24 h)<br />

Hydraulic – measured with HLP 46, oil = 40 °C ±5 °C (104 °F ±41 °F)<br />

Pressure fl uid<br />

Hydraulic oil to DIN 51524...535, other fl uids after prior consultation<br />

Viscosity range re<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mended mm 2 /s (SUS) 20 to 100 (90 to 460)<br />

max. permitted mm 2 /s (SUS) 10 to 800 (45 to 3700)<br />

Pressure fl uid temperature range °C (°F) –20 to +70 (–4 to +158)<br />

Maximum permitted degree of contamination of<br />

pressure fl uid Purity class to ISO 4406 (c)<br />

Class 18/16/13 1)<br />

Direction of fl ow<br />

See symbol<br />

Max. set pressure (at Q = 1 l/min [0.26 GPM]) bar (PSI) 80 (1160) 180 (2600) 250 (3600) 315 (4500)<br />

Minimum pressure (at Q = 1 l/min [0.26 GPM]) bar (PSI) 3 (43) 4 (58) 5 (72) 8 (116)<br />

Note: At Q max = 1.5 l/min [0.40 GPM] the pressure levels stated<br />

here increase<br />

Max. mechanical pressure limitation level,<br />

bar (PSI) < 85 (1200) < 186 (2700) < 258 (3700) < 325 (4700)<br />

e.g. when solenoid current I I max<br />

Max. working pressure<br />

bar (PSI) Port P: 315 (4500)<br />

(at Q = 1 l/min [0.26 GPM])<br />

Max. pressure bar (PSI) Port T: 250 (2900)<br />

Static/Dynamic<br />

Hysteresis % 0.2<br />

Range of inversion % 0.1<br />

Manufacturing tolerance % ±5<br />

Response time 100 % signal change ms 30<br />

10 % signal change ms 10<br />

Thermal drift<br />

< 1 % at ΔT = 40 °C (104 °F)<br />

Conformity EN 61000-6-2: 2002-08<br />

EN 61000-6-3: 2002-08<br />

1)<br />

The purity classes stated for the <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponents must be <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>plied with in hydraulic systems.<br />

Effective fi l<strong>tr</strong>ation prevents problems and also extends the service life of <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponents.<br />

For a selection of fi lters, see catalog sheets RE 50070, RE 50076 and RE 50081.<br />