Safety Integrity Level (SIL) Concept Chapter 1<br />
Components Suitable for Use With <strong>1756</strong> <strong>GuardLogix</strong> <strong>Controller</strong> Safety <strong>Systems</strong><br />
Device Type Cat. No. Description<br />
Chassis<br />
Power supply<br />
Communication<br />
modules<br />
Programming<br />
software<br />
CompactFlash<br />
Cards<br />
<strong>1756</strong>-A4, A7, A10,<br />
A13, A17<br />
Series (2) Version (2) Instructions<br />
Installation<br />
Chassis B N/A <strong>1756</strong>-IN080<br />
<strong>1756</strong>-PA72 Power supply, ac C N/A<br />
<strong>1756</strong>-PB72 Power supply, dc C N/A<br />
<strong>1756</strong>-PA75 Power supply, ac B N/A<br />
<strong>1756</strong>-IN596<br />
<strong>1756</strong>-PB75 Power supply, dc B N/A<br />
<strong>1756</strong>-PA75R (1) Redundant power supply, ac A N/A <strong>1756</strong>-IN573<br />
<strong>1756</strong>-PB75R Redundant power supply, dc A N/A<br />
<strong>1756</strong>-<strong>EN</strong>BT<br />
<strong>1756</strong>-<strong>EN</strong>2T<br />
<strong>1756</strong>-<strong>EN</strong>2F<br />
EtherNet/IP bridge module<br />
A<br />
A<br />
A<br />
3.6<br />
2.005<br />
2.005<br />
Related Documentation (4)<br />
<strong>1756</strong>-IN019<br />
<strong>1756</strong>-IN603<br />
<strong>1756</strong>-IN606<br />
User Manual<br />
None available.<br />
<strong>EN</strong>ET-UM001<br />
1734-A<strong>EN</strong>T POINT I/O Ethernet Adapter A 3.001 1734-IN590 1734-UM011<br />
<strong>1756</strong>-DNB DeviceNet bridge module A 6.2 <strong>1756</strong>-IN566 DNET-UM004<br />
<strong>1756</strong>-CN2 ControlNet bridge module A 12.1 <strong>1756</strong>-IN602 CNET-UM001<br />
<strong>1756</strong>-CN2R<br />
ControlNet bridge module,<br />
redundant media<br />
A 12.1 <strong>1756</strong>-IN602 CNET-UM001<br />
9324-xxxx RSLogix 5000 software N/A 14 (3) NA Consult online help.<br />
1784-CF64 64MB CompactFlash Card N/A N/A N/A N/A<br />
1784-CF128 128MB CompactFlash Card N/A N/A N/A N/A<br />
(1) A <strong>1756</strong>-PSCA or <strong>1756</strong>-PSCAR redundant power supply chassis adapter is required for use with redundant power supplies.<br />
(2) This version or later.<br />
(3) RSLogix 5000 software, version 15, does not support <strong>GuardLogix</strong> safety controllers.<br />
(4) These publications are available from Rockwell Automation by visiting http://literature.rockwellautomation.<strong>com</strong>.<br />
Slots of a SIL 3 system chassis not used by the <strong>1756</strong> SIL 3 system may<br />
be populated with other ControlLogix (<strong>1756</strong>) modules that are<br />
certified to the Low Voltage and EMC Directives.<br />
Expansion slots of a SIL 3 system bus that are not used by the 1768<br />
SIL 3 system may be populated with other CompactLogix (1768)<br />
modules that are certified to the Low Voltage and EMC Directives.<br />
To find the certificates for the ’Programmable Control – ControlLogix<br />
Product Family’ and ’Programmable Control – CompactLogix Product<br />
Family’, refer to<br />
http://www.rockwellautomation.<strong>com</strong>/products/certification/ce/ .<br />
Publication <strong>1756</strong>-<strong>RM093F</strong>-<strong>EN</strong>-P - January 2010 17