Chapter 5<br />

Characteristics of Safety Tags, the Safety Task, and Safety Programs<br />

For Cat 1, Cat 2, and SIL 2 safety functions, the Guard I/O safety<br />

modules need specific configurations within the <strong>GuardLogix</strong> project.<br />

In this example, inputs 0, 1, 6, 7, 8, 9, 10, and 11 are part of a CAT 1,<br />

2 or SIL 2 safety function. Inputs 2 and 3, as well as 4 and 5 are part of<br />

a CAT 3, CAT 4, or SIL 3 safety function.<br />

Input Configuration<br />

Field<br />

Type<br />

Discrepancy Time<br />

Point Mode<br />

Test Source<br />

Input Delay Time<br />

Value<br />

Single<br />

N/A<br />

Safety Pulse Test<br />

Set values based on how the field device is physically wired to the<br />

module. To make sure the test source is properly enabled, open and<br />

view settings on the Test Output tab.<br />

User input based on field device characteristics.<br />

IMPORTANT<br />

The onboard pulse test outputs (T0…Tx) are typically used with<br />

field devices that have mechanical contacts. If a safety device<br />

that has electronic outputs is used (feeding safety inputs), they<br />

must have the appropriate safety ratings.<br />

IMPORTANT<br />

If you are using <strong>GuardLogix</strong> Safety Application Instructions, be<br />

sure to configure your safety input modules as single, not<br />

equivalent or <strong>com</strong>plementary. These instructions provide all<br />

dual-channel functionality necessary for PLd (Cat. 3) or<br />

PLe (Cat. 4) safety functions.<br />

Refer to the <strong>GuardLogix</strong> Safety Application Instruction Set<br />

Reference Manual, publication <strong>1756</strong>-RM095.<br />