Safety Instructions<br />
Appendix A<br />
Metal Form Safety<br />
Application Instructions<br />
These instructions are available in RSLogix 5000 software, version 17<br />
and later.<br />
Mnemonic Name Purpose Certification<br />
CBCM Clutch Brake Continuous<br />
Mode<br />
Used for press applications where continuous operation is desired.<br />
• BG<br />
• TÜV<br />
CBIM Clutch Brake Inch Mode Used for press applications where minor slide adjustments are required, such<br />
as press setup.<br />
• BG<br />
• TÜV<br />
CBSSM Clutch Brake Single<br />
Stoke Mode<br />
Used in single-cycle press applications.<br />
• BG<br />
• TÜV<br />
CPM Crankshaft Position<br />
Monitor<br />
Used to determine the slide position of the press.<br />
• BG<br />
• TÜV<br />
CSM Camshaft Monitor Monitors motion for the starting, stopping, and running operations of a<br />
camshaft.<br />
• BG<br />
• TÜV<br />
EPMS Eight-position Mode Monitors eight safety inputs to control one of the eight outputs corresponding • BG<br />
Selector<br />
to the active input.<br />
• TÜV<br />
AVC Auxiliary Valve Control Controls an auxiliary valve that is used in conjunction with a main valve. • TÜV<br />
MVC Main Valve Control Controls and monitors a main valve. • BG<br />
• TÜV<br />
MMVC Maintenance Manual<br />
Valve Control<br />
Used to manually drive a valve during maintenance operations.<br />
• BG<br />
• TÜV<br />