System Configurator <strong>and</strong> Order Information Guide<br />

<strong>Tower</strong> <strong>and</strong> <strong>Rack</strong> <strong>UPSs</strong> <strong>from</strong> <strong>Masterguard</strong> Date of issue 28.04.2008<br />

E<br />

PDU1<br />

For better serviceability PDU 1 <strong>and</strong> PDU2 offers a Bypass switch to disconnect UPS<br />

<strong>from</strong> mains <strong>and</strong> all load will be connected to mains directly. This allows to run load<br />

while UPS is maintained.<br />

D:UPS-PDU1<br />

UPS PDU1 3xC32A-2xC16A-2xIEC16A<br />

to extend the sockets of a 6kVA or 10kVA rack UPS<br />

Is connected to the 1-phase permanent connection<br />

of the UPS by an electrician.<br />

Output side, 1-phase<br />

3x IEC309 CEE blue (32A)<br />

2x IEC309 CEE blue (16A)<br />

3x IEC320 C19 (16A)<br />

Occupies 4U in the rack<br />

Max. 1x per 6 kVA rack UPS (D:UPS-R6-PV1)<br />

Max. 1x per 10 kVA rack UPS (D:UPS-R10-PV1)<br />

PDU2<br />

D:UPS-PDU2<br />

UPS PDU1 3xC32A-2xC16A-2xIEC16A<br />

to extend the sockets of a 6kVA or 10kVA rack UPS<br />

<strong>and</strong> parallel connection of two 6kVA or 10kVA rack <strong>UPSs</strong><br />

Is connected to the 1-phase permanent connection<br />

of both <strong>UPSs</strong> by an electrician.<br />

Output side, 1-phase<br />

3x IEC309 CEE blue (32A)<br />

2x IEC309 CEE blue (16A)<br />

3x IEC320 C19 (16A)<br />

Occupies 4U in the rack<br />

Max. 1x per 6 kVA rack UPS (D:UPS-R6-PV1)<br />

Max. 1x per two 10 kVA rack <strong>UPSs</strong> (D:UPS-R10-PV1)<br />

Operation only permitted with two connected <strong>UPSs</strong><br />

PDU 1 <strong>and</strong> 2 front view<br />

PDU 1 is mounted directly above the UPS in a <strong>Rack</strong><br />

Preassembled, 3-wire cable for permanent connection of<br />

PDU 1 <strong>and</strong> 2 is already conneccted at the PDU side.<br />

2 cables for PDU 1 <strong>and</strong> 4 for PDU2<br />

Extension of the UPS power to 12kVA / 20kVA by<br />

parallel connection of two 6kVA or 10kVA <strong>UPSs</strong><br />

LAN adapter always required for each UPS<br />

License cluster software (D:UPSSW-HA-CLUSTER)<br />

License enterprise software (D:UPSSW-HA-ENTERPR)<br />

is also required<br />

PDU 2 is mounted always between both <strong>UPSs</strong> in a <strong>Rack</strong><br />

whereas at the second arangement the Battery Pack<br />

is mounted above the UPS in a <strong>Rack</strong>. Refer to the drawings<br />

Additionally without service bypass<br />

a 50 A PDU is also available.<br />

Note: cannot be ordered together with<br />

a PRIMEPOWER PRIMECENTER <strong>Rack</strong><br />

Can be used only for:<br />

6kVA <strong>Rack</strong> D:UPS-R6-PV1<br />

10kVA <strong>Rack</strong> D:UPS-R10-PV1<br />

10kVA <strong>Tower</strong> D:UPS31-T10-PV1<br />

S26361-F2262-E500<br />

UPS PDU 50A 2U,6x16A+4x10A IEC320<br />

Power distribution unit for UPS hard wire output<br />

For APC Online UPS <strong>and</strong> Runtime expansion modules<br />

occupies 2U in racks<br />

S26361-F2262-L500<br />

UPS PDU 50A 2U,6x16A+4x10A IEC320<br />

Loose delivery<br />

Conection at customer side has to<br />

be done by an electrician.<br />

D:GPRAC-ZB31<br />

Dummy Panel for 19inch rack, 2U<br />

D:GPRAC-ZB5212<br />

Bracket up to 100 kg<br />

F<br />

Fujitsu Siemens Computers Enterprise Products - PRIMEPOWER / PRIMERGY Servers 7 of 12