Refrigerant Piping<br />

Refrigerant Pipe Lengths and Height<br />

The length and height of the refrigeration pipe must be within the following values.<br />

Minimum Pipe Length<br />

HWS-802H-E : 5 m<br />

HWS-1102H-E : 3 m<br />

HWS-1402H-E : 3 m<br />

Maximum Pipe Length and Height<br />

H: Max. ±30 m (above or below)<br />

L: Max. 30 m<br />

Quick Reference Guide - Page 7<br />

Note<br />

The maximum pipe length cannot be increased using additional<br />

refrigerant.<br />

Refrigeration and Water Cycle Diagrams<br />

Hydro Unit<br />

Expansion vessel<br />

Air vent valve<br />

Pressure<br />

relief<br />

valve<br />

Pressure<br />

Gauge<br />

THO<br />

Sensor<br />

Thermal<br />

Protector<br />

Refrigerant pipe<br />

at gas side<br />

(Outer ø15.88)<br />

Hi_P_Switch<br />

TWO<br />

Sensor<br />

Pump<br />

Water Out<br />

(1 1/4")<br />

Refrigerant pipe<br />

at liquid side<br />

(Outer ø9.52)<br />

P_Sensor<br />

TC<br />

Sensor<br />

Backup heater<br />

Flow_Switch<br />

TWI<br />

Sensor<br />

Water IN<br />

(1 1/4")<br />

Water Heat exchanger