Series <strong>GRF300</strong>/GRF303<br />
DPDT Non-Latching Electromechanical Relay<br />
Signal Integrity up to 18Gbps<br />
SERIES <strong>GRF300</strong>/GRF303<br />
TYPICAL RF CHARACTERISTICS (See RF Notes)<br />
Isolation Across Contacts (RF Note 4)<br />
Isolation Pole to Pole (RF Note 5)<br />
0<br />
0<br />
-10<br />
-10<br />
Isolation (dB)<br />
-20<br />
-30<br />
-40<br />
Isolation (dB)<br />
-20<br />
-30<br />
-40<br />
-50<br />
-50<br />
-60<br />
-60<br />
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000<br />
Frequency (MHz)<br />
-70<br />
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000<br />
Frequency (MHz)<br />
0<br />
Insertion Loss (RF Note 6)<br />
2.0<br />
VSWR (RF Note 6)<br />
Insertion Loss (dB)<br />
-0.2<br />
-0.4<br />
-0.6<br />
VSWR<br />
1.8<br />
1.6<br />
1.4<br />
-0.8<br />
1.2<br />
-1<br />
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000<br />
Frequency (MHz)<br />
1.0<br />
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000<br />
Frequency (MHz)<br />
1.1<br />
<strong>GRF300</strong> Time Response (RF Note 6)<br />
0.9<br />
0.7<br />
90%<br />
37ps reference<br />
Volt<br />
0.5<br />
62.3ps propagation delay time<br />
0.3<br />
0.1<br />
51.3ps pulse rise time<br />
10%<br />
-0.1<br />
-100 0 100 200 300 400 500 600 700 800 900<br />
Time (ps)<br />
RF NOTES<br />
1. Test conditions: a. Fixture: .031” copper clad, reinforced PTFE, RT/duroid ® 6002 with SMA connectors.<br />
(RT/duroid ® is a registered trademark of Rogers Corporation.)<br />
b. RF ground shield is soldered to PCB RF ground plane.<br />
c. Room ambient temperature.<br />
d. Terminals not tested were terminated with 50-ohm load.<br />
e. Contact signal level: –10 dBm.<br />
f. No. of test samples: 2.<br />
2. Data presented herein represents typical characteristics and is not intended for use as specification limits.<br />
3. Data is per pole, except for pole-to-pole data.<br />
4. Data is the average from readings taken on all open contacts.<br />
5. Data is the average from readings taken on poles with coil energized and de-energized.<br />
6. Data is the average from readings taken on all closed contacts.<br />
7. Test fixture effect de-embedded from frequency and time response data.<br />
<strong>GRF300</strong>/GRF303 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE RELAYS<br />
<strong>GRF300</strong>GRF303\082013\Q3