11.01.2015 Views

GRF300-12 - Teledyne Relays

GRF300-12 - Teledyne Relays

GRF300-12 - Teledyne Relays

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Series <strong>GRF300</strong>/GRF303<br />

DPDT Non-Latching Electromechanical Relay<br />

Signal Integrity up to 18Gbps<br />

SERIES <strong>GRF300</strong>/GRF303<br />

TYPICAL RF CHARACTERISTICS (See RF Notes)<br />

Isolation Across Contacts (RF Note 4)<br />

Isolation Pole to Pole (RF Note 5)<br />

0<br />

0<br />

-10<br />

-10<br />

Isolation (dB)<br />

-20<br />

-30<br />

-40<br />

Isolation (dB)<br />

-20<br />

-30<br />

-40<br />

-50<br />

-50<br />

-60<br />

-60<br />

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000<br />

Frequency (MHz)<br />

-70<br />

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000<br />

Frequency (MHz)<br />

0<br />

Insertion Loss (RF Note 6)<br />

2.0<br />

VSWR (RF Note 6)<br />

Insertion Loss (dB)<br />

-0.2<br />

-0.4<br />

-0.6<br />

VSWR<br />

1.8<br />

1.6<br />

1.4<br />

-0.8<br />

1.2<br />

-1<br />

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000<br />

Frequency (MHz)<br />

1.0<br />

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000<br />

Frequency (MHz)<br />

1.1<br />

<strong>GRF300</strong> Time Response (RF Note 6)<br />

0.9<br />

0.7<br />

90%<br />

37ps reference<br />

Volt<br />

0.5<br />

62.3ps propagation delay time<br />

0.3<br />

0.1<br />

51.3ps pulse rise time<br />

10%<br />

-0.1<br />

-100 0 100 200 300 400 500 600 700 800 900<br />

Time (ps)<br />

RF NOTES<br />

1. Test conditions: a. Fixture: .031” copper clad, reinforced PTFE, RT/duroid ® 6002 with SMA connectors.<br />

(RT/duroid ® is a registered trademark of Rogers Corporation.)<br />

b. RF ground shield is soldered to PCB RF ground plane.<br />

c. Room ambient temperature.<br />

d. Terminals not tested were terminated with 50-ohm load.<br />

e. Contact signal level: –10 dBm.<br />

f. No. of test samples: 2.<br />

2. Data presented herein represents typical characteristics and is not intended for use as specification limits.<br />

3. Data is per pole, except for pole-to-pole data.<br />

4. Data is the average from readings taken on all open contacts.<br />

5. Data is the average from readings taken on poles with coil energized and de-energized.<br />

6. Data is the average from readings taken on all closed contacts.<br />

7. Test fixture effect de-embedded from frequency and time response data.<br />

<strong>GRF300</strong>/GRF303 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE RELAYS<br />

<strong>GRF300</strong>GRF303\082013\Q3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!