11.01.2015 Views

GRF300-12 - Teledyne Relays

GRF300-12 - Teledyne Relays

GRF300-12 - Teledyne Relays

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Series <strong>GRF300</strong>/GRF303<br />

DPDT Non-Latching Electromechanical Relay<br />

Signal Integrity up to 18Gbps<br />

SERIES <strong>GRF300</strong>/GRF303<br />

GENERAL ELECTRICAL SPECIFICATIONS (@25°C)<br />

Contact Arrangement<br />

Rated Duty<br />

Contact Resistance<br />

Contact Load Rating<br />

Contact Life Ratings<br />

Coil Operating Power<br />

Operate Time<br />

Release Time<br />

Intercontact Capacitance<br />

Insulation Resistance<br />

Dielectric Strength<br />

Negative Coil Transient (Vdc)<br />

Diode P.I.V. (Vdc)<br />

2 Form C (DPDT)<br />

Continuous<br />

0.15 Ω max.<br />

Resistive: 1Amp/28Vdc<br />

Low level: 10 to 50 μA @ 10 to 50 mV<br />

10,000,000 cycles (typical) at low level<br />

<strong>GRF300</strong>-5: 500 mW @ nominal coil<br />

GRF303-5: 250 mW @ nominal coil<br />

<strong>GRF300</strong>: 4.0 mS max.<br />

GRF303: 6.0 mS max.<br />

<strong>GRF300</strong>: 3.0 mS max.<br />

GRF303: 3.0 mS max.<br />

0.4 pf typical<br />

1,000 MΩ min. between mutually isolated terminals<br />

350 Vrms (60 Hz) @ atmospheric pressure<br />

<strong>GRF300</strong>D/GRF303D,<br />

<strong>GRF300</strong>DD/GRF303DD<br />

<strong>GRF300</strong>D/GRF303D,<br />

<strong>GRF300</strong>DD/GRF303DD<br />

DETAILED ELECTRICAL SPECIFICATIONS (@25°C)<br />

BASE PART NUMBERS (<strong>GRF300</strong>, <strong>GRF300</strong>D,<br />

<strong>GRF300</strong>DD)<br />

<strong>GRF300</strong>-<strong>12</strong>: 370 mW @ nominal coil<br />

GRF303-<strong>12</strong>: 169 mW @ nominal coil<br />

<strong>GRF300</strong>D, <strong>GRF300</strong>DD: 4.0 mS max.<br />

GRF303D, GRF303DD: 7.5 mS max.<br />

<strong>GRF300</strong>-5<br />

<strong>GRF300</strong>D-5<br />

<strong>GRF300</strong>DD-5<br />

1.0 max<br />

100 min.<br />

<strong>GRF300</strong>-<strong>12</strong><br />

<strong>GRF300</strong>D-<strong>12</strong><br />

<strong>GRF300</strong>DD-<strong>12</strong><br />

Coil Voltage, Nominal (Vdc) 5.0 <strong>12</strong>.0<br />

<strong>GRF300</strong>, <strong>GRF300</strong>D 50 390<br />

Coil Resistance (Ohms<br />

±20%)<br />

<strong>GRF300</strong>DD (General<br />

39 390<br />

Note II)<br />

Coil Current (mAdc@ 25 Min. 93.2 25.6<br />

°C)(RF300DD Series) Max. <strong>12</strong>8.2 32.8<br />

Pick-up Voltage (Vdc<br />

max.)<br />

<strong>GRF300</strong>, <strong>GRF300</strong>D, 3.6 9.0<br />

<strong>GRF300</strong>DD 3.9 10.0<br />

BASE PART NUMBERS (RF303, RF303D,<br />

RF303DD)<br />

GRF303-5<br />

GRF303D-5<br />

GRF303DD-5<br />

GRF303-<strong>12</strong><br />

GRF303D-<strong>12</strong><br />

GRF303DD-<strong>12</strong><br />

Coil Voltage, Nominal (Vdc) 5.0 <strong>12</strong>.0<br />

GRF303, GRF303D 100 850<br />

Coil Resistance (Ohms<br />

±20%)<br />

GRF303DD (General<br />

64 850<br />

Note II)<br />

Coil Current (mAdc@ 25 Min. 56.8 11.7<br />

°C)(RF303DD Series) Max. 78.1 15.0<br />

Pick-up Voltage (Vdc<br />

max.)<br />

GRF303, GRF303D, 3.6 9.0<br />

GRF303DD 3.7 11.0<br />

© 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com <strong>GRF300</strong>/GRF303 Page 5<br />

<strong>GRF300</strong>GRF303\082013\Q3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!