LG Manufacturer's Certification Statement
LG Manufacturer's Certification Statement
LG Manufacturer's Certification Statement
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
April 9, 2010<br />
<strong>LG</strong> 2010 Tax Qualified Models<br />
Manufacturer <strong>Certification</strong> <strong>Statement</strong><br />
The American Recovery and Reinvestment Tax Act of 2009<br />
The American Recovery and Reinvestment Act of 2009 signed on February 17, 2009, by<br />
President Obama has made significant changes to homeowner tax credits for qualifying energy<br />
efficient systems placed in service between January 1, 2009 – December 31, 2010.<br />
Homeowners may be able to claim 30% of the installed cost in tax credits up to a maximum of<br />
$1,500 for energy efficient home improvements.<br />
Energy Efficiency Requirements for Tax Rebate:<br />
Product Type - Air Source Heat Pumps (Electric Heat Pumps)<br />
• EER 12.5 or greater<br />
• SEER 15 or greater<br />
• HSPF 8.5 or greater<br />
This certifies that the HVAC system models listed in table 1 are considered Qualified Energy<br />
Property and Qualify for tax benefit for the 2009 and 2010 tax years.<br />
Table 1.<br />
Qualified Single Split Units Eligible for Tax Benefit – 2010 Models<br />
Single Split - Outdoor DFS 1 Single Split - Indoor DFS 1 EER SEER HSPF<br />
Qualified for Tax<br />
Benefit<br />
LAU096HV LAN096HV (Indoor Unit) 12.5 19.0 9.2 Yes<br />
LSU091HSV LSN091HSV (Indoor Unit) 13.0 20.0 11.0 Yes<br />
LSU121HSV LSN121HSV (Indoor Unit) 12.5 20.0 10.0 Yes<br />
LSU161HSV LSN161HSV (Indoor Unit) 12.5 18.4 9.7 Yes<br />
1. DFS = Duct Free Split<br />
2. Models above are single split unit models (One outdoor unit paired with one indoor unit = One single split system)<br />
3. Models with multiple indoor units on one out door unit refer to table 2 below.<br />
1
Table 2.<br />
Qualified Multi Split Units Eligible for Tax Benefit - 2010 DFS Models<br />
DFS 4<br />
Flex Multi Systems 5<br />
(Condensing Unit)<br />
Non-Ducted Evaporator<br />
Combination Only<br />
(Qualified Combination Chart<br />
for Tax Benefit) EER SEER HSPF<br />
Qualified for Tax<br />
Benefit<br />
9+9 12.5 16 8.5 Yes<br />
9+12 12.5 15 8.5 Yes<br />
LMU186HV 12+12 12.5 15 8.5 Yes<br />
9+9+9 12.5 16 10.3 Yes<br />
9+9+12 12.5 16 10.3 Yes<br />
LMU246HV 9+12+12 12.5 16 10.3 Yes<br />
4. DFS = Duct Free Split<br />
5. Flex Multi Systems = One outdoor unit with multiple indoor units<br />
6. Select from indoor unit models for combinations: LMN095HVT, LMN125HVT, LMAN095HVT, LMAN125HVT, LMCN125HV<br />
Examples 9+9 = Connected indoor units include two nominal 9,000 Btu/h units.<br />
9+12 = Connected indoor units include one nominal 9,000 Btu/h unit and one nominal 12,000 Btu/h unit.<br />
Tax credits for home improvement guidelines:<br />
• Must be "placed in service" from January 1, 2009 through December 31, 2010<br />
• Must be for taxpayer's principal residence<br />
• $1,500 is the maximum total amount that can be claimed for all products placed in service in<br />
2009 & 2010 for most home improvements, EXCEPT for geothermal heat pumps, solar water<br />
heaters, solar panels, fuel cells, and windmills which are not subject to this cap, and are in effect<br />
through 2016<br />
• Must have a Manufacturer <strong>Certification</strong> <strong>Statement</strong> to qualify<br />
• For record keeping, save your receipts and this Manufacturer <strong>Certification</strong> <strong>Statement</strong><br />
• Improvements made in 2009 will be claimed on your 2009 taxes (filed by April 15, 2010) — use<br />
IRS Tax Form 5695 (2009 version) — it will be available late 2009 or early 2010. Note: Some<br />
homeowner income guidelines may apply. Please consult your tax advisor for eligibility<br />
requirements.<br />
2
Equipment Classification<br />
CEE Tier 2<br />
<strong>Certification</strong> <strong>Statement</strong><br />
"Under penalties of perjury, I declare that I have examined this certification, and to the best of<br />
my knowledge and belief, the facts presented in support of this certification are true, correct,<br />
and complete.”<br />
Steve Schmitt<br />
Director<br />
Commercial Air Conditioning<br />
<strong>LG</strong> Electronics U.S.A., Inc.<br />
3
1/3<br />
Job Name :<br />
Purchaser :<br />
Engineer :<br />
Submitted To :<br />
Submitted By :<br />
Unit Designation : Schedule No.:<br />
Submittal Data :<br />
System Model #<br />
LS181HSV<br />
Location :<br />
P.O. No. :<br />
Architect :<br />
Date :<br />
For : □ Reference □ Approval □ Construction<br />
Model No.:<br />
Air Conditioner<br />
Single Zone Mini Split<br />
LSN181HSV<br />
Indoor Model #<br />
Outdoor Model #<br />
LSN181HSV<br />
LSU181HSV<br />
8 1/4<br />
Performance<br />
Capacity (Cooling)<br />
(Heating)<br />
SEER<br />
Air Circulation (CFM H/M/L)<br />
Fan Speeds<br />
Dehumidification (pts/hr)<br />
Indoor dB(A)<br />
Outdoor dB(A)<br />
18,000<br />
20,600<br />
17.8<br />
600/510/420<br />
6/Auto/Chaos<br />
5.5<br />
45/40/34<br />
52<br />
40 3/5<br />
12 4/5<br />
9 21/25<br />
Electrical :<br />
Rated Voltage Outdoor<br />
Rated Voltage Indoor<br />
Rated Amps (230/208V)<br />
Minimum Circuit Ampacity<br />
Maximum Overcurrent Protection<br />
230/280 , 60, 1<br />
230/280 , 60, 1<br />
10.5/11.0<br />
17<br />
25<br />
18 1/9 22 1/8<br />
Dimensions :<br />
Indoor Dimension (WxHxD, inches)<br />
Indoor Weight (lbs)<br />
Outdoor Dimension (WxHxD, inches)<br />
Outdoor Weight (lbs)<br />
Refrigerant Piping :<br />
Liquid Side (inches, O.D)<br />
Suction Side (inches, O.D)<br />
Additional Refrigerant (oz./ft.)<br />
Maximum Pipe Length (ft)<br />
Maximum Elevation (ft)<br />
Operating Range :<br />
Cooling Operating Range (℉, standard)<br />
Heating Operating Range (℉)<br />
40 3/5 x12 4/5 x9 21/25<br />
37.5<br />
34 3/10 x31 1/2 x12 3/5<br />
132.3<br />
3/8”<br />
5/8”<br />
0.38<br />
98’<br />
49’<br />
64-86<br />
60-86<br />
Standard Features :<br />
• Five Year Compressor Warranty<br />
• Three Year Functional Parts Warranty<br />
• Inverter (Variable Speed Compressor)<br />
• Plasma Air Purifying System<br />
• Chaos Swing Air Circulation<br />
•Jet Cool TM<br />
• Auto Restart<br />
• Gold Fin TM Anti-Corrosion<br />
• Built-in Low Ambient Standard down to 14℉ at cooling mode<br />
31 1/2<br />
LSU181HSV<br />
2 2/9 2<br />
4 1/7 8 1/7<br />
34 3/10<br />
21 1/2 6 2/7<br />
11 6/7<br />
13 2/5<br />
14 1/6<br />
2<br />
12 3/5<br />
Note :<br />
1<br />
3<br />
8 1/8<br />
<strong>LG</strong> Electronics Inc. HVAC Division<br />
1000 Sylvan Avenue, Englewood Cliffs, NJ 07632 / www.lgusa.com www.lghvac.com<br />
C <strong>LG</strong> Electronics USA 2010<br />
Specifications and information in this submittal data are subject to change without notice.