Hazardous Location GSX/GSM Class I Division 2<br />

Terminal Box Wiring Diagram<br />

Brake +<br />

Brake -<br />

+<br />

24 vdc ~ 1 amp<br />

Power Supply<br />

for brake<br />

-<br />

15<br />

14<br />

13<br />

12<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

T<br />

S<br />

R<br />

Therm<br />

Therm<br />

Shield<br />

Ref<br />

Ref GND<br />

Sin<br />

Sin GND<br />

Cos<br />

Cos GND<br />

Resolver<br />

Therm<br />

Sw.<br />

PE<br />

Actuator<br />

Note 1<br />

+<br />

24 vdc ~ 1 amp<br />

Power Supply<br />

for logic<br />

-<br />

Brake Coil<br />

Note 1: Thermal switch normally closed;<br />

opens when stator temp exceeds 130 deg. C.<br />

Ordering Information<br />

Please use the ordering guide from the GSX (page 134) and<br />

GSM (page 137) sections with two callout selections as<br />

described below. The required connections selection is “T”<br />

and the required options selection is “NI”<br />

GSXAA - BBCC - D E F - GGG - HHH - II - (XX...XX)<br />

Connections<br />

T = Terminal box with NPT ports<br />

Options<br />

NI = Non-Incendive<br />

T<br />

NI<br />

Terminal Box Dimensions<br />

1.10<br />

27.9<br />

2.20<br />

55.9<br />

1.250<br />

31.8<br />

Power and I/O<br />

2X<br />

1/2 NPT<br />

CID2, GSX &<br />

GSM Series<br />

9.52.500.6200 | www.exlar.com 129