CAUTION<br />
The installation must be adjusted to obtain a temperature rise within the range listed on<br />
the unit nameplate.<br />
Clearances<br />
WARNING<br />
To avoid death, personal injury or property damage due to fire, clearances to combustible<br />
surfaces listed as shown must be observed.<br />
Propane Gas Conversion Chart<br />
Model<br />
PGB**C***2E<br />
PGB**C***2E<br />
Gas<br />
Natural<br />
Propane<br />
Natural<br />
Propane<br />
Altitude<br />
(Feet)<br />
0 - 6000<br />
Kit<br />
None<br />
LPTK09<br />
6001 - 11000<br />
HANG07<br />
HALP09<br />
Orifice<br />
#43<br />
#55<br />
#45<br />
#56<br />
Manifold<br />
Pressure<br />
3.5" W.C<br />
10.0" W.C.<br />
3.5" W.C<br />
10.0" W.C.<br />
NOTE: In Canada, gas furnaces are certified to 4,500<br />
feet only.<br />
24" Clearance<br />
(Condenser End)<br />
36"<br />
Maximum<br />
Overhang<br />
48" Minimum<br />
36" Side Overhang<br />
Clearance<br />
for Servicing<br />
Recommended<br />
Vinyl Coated<br />
Canvas<br />
Connections<br />
Insulated<br />
Return<br />
Duct<br />
2-15/16"<br />
47-5/32"<br />
Minimum 9" Clearance<br />
to Combustibles<br />
36" Clearance for<br />
Service Required<br />
0" Minimum<br />
Clearance to<br />
Combustibles<br />
Insulated<br />
<strong>Supply</strong><br />
Duct<br />
NOTES:<br />
1. All units are manufactured for use on 208/230<br />
VAC, 60 Hz, single phase electrical supply.<br />
20-3/8"<br />
4-15/32"<br />
6-5/8"<br />
2-3/8"<br />
Electrical Only<br />
(Bottom Of Unit)<br />
(3/4", 1-1/4" K.O.)<br />
Center of<br />
Gravity<br />
BOTTOM DUCT<br />
OPENING<br />
(SUPPLY)<br />
20-3/16"<br />
Inside<br />
BOTTOM DUCT<br />
OPENING<br />
(RETURN)<br />
10"<br />
Inside<br />
6-15/16"<br />
28-1/8"<br />
42-11/16"<br />
20"<br />
(Inside)<br />
3-1/2"<br />
5-5/16"<br />
25-3/8"<br />
49-3/16"<br />
2. IMPORTANT: While the data is presented as a<br />
guide, it is required to determine the proper size<br />
fuses and wires to electrically connect the unit in<br />
accordance with the National Electrical Code and/<br />
or all existing local codes.<br />
3. Performance figures are based on Department of<br />
Energy information and requirements under continuous<br />
operating conditions. Performance will<br />
vary with weather conditions and use.<br />
Electrical Only<br />
(3/4", 1-1/4" K.O.)<br />
Exhaust<br />
Flue<br />
Electrical Only<br />
(3/4", 1-1/4" K.O.)<br />
36-7/16"<br />
27-35/64"<br />
1-7/8"<br />
SUPPLY<br />
AIR<br />
(Shipped With<br />
Covers In Place)<br />
RETURN<br />
AIR<br />
(Shipped With<br />
Covers In Place)<br />
1-7/16"<br />
18"<br />
Combustion<br />
Air Intake<br />
3/4" Condensate<br />
Drain Connection<br />
Gas<br />
Low<br />
Voltage<br />
1/2"<br />
17-3/32"<br />
27-35/64"<br />
1-1/2"<br />
16" 16"<br />
5-3/8"<br />
43-1/16"<br />
(Inside Rail)<br />
1-11/64"<br />
1-1/8"<br />
Diameter<br />
Hole<br />
1-29/64"<br />
13-29/64"<br />
15-25/32"<br />
4-9/32"<br />
2