14.01.2015 Views

PGB42-60C SPECS.pdf - Johnstone Supply

PGB42-60C SPECS.pdf - Johnstone Supply

PGB42-60C SPECS.pdf - Johnstone Supply

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Heating & Air Conditioning<br />

Comfort. Quality. Trust.<br />

DESIGN<br />

®<br />

PGB(42-60)C**E<br />

PACKAGE GAS-ELECTRIC<br />

SPECIFICATION SHEET<br />

Installer: Affix literature adjacent to the unit.<br />

C E RTIFIE D<br />

C E R T I F I E D<br />

Specifications<br />

<strong>PGB42</strong>C1152E PGB48C0902E PGB48C1152E PGB48C1402E PGB<strong>60C</strong>0902E PGB<strong>60C</strong>1152E PGB<strong>60C</strong>1402E<br />

COOLING COOLING CAPACITY,BTUH 40,500 47,000 47,000 47,000 59,000 59,000 59,000<br />

CAPACITY SEER 11.05 11.05 11.05 11.05 11.05 11.05 11.05<br />

HEATING INPUT BTUH US 115,000 92,000 115,000 138,000 92,000 115,000 138,000<br />

HEATING CANADIAN (0-2000 FT) 115,000 92,000 115,000 138,000 92,000 115,000 138,000<br />

CAPACITY 1 CANADIAN (0-4500 FT) 115,000 92,000 115,000 138,000 92,000 115,000 138,000<br />

HEATING OUTPUT BTUH US 92,000 73,600 92,000 110,400 73,600 92,000 110,400<br />

CANADIAN (0-2000 FT) 92,000 73,600 92,000 110,400 73,600 92,000 110,400<br />

CANADIAN (0-4500 FT) 92,000 73,600 92,000 110,400 73,600 92,000 110,400<br />

AFUE - % 80.0 80.0 80.0 80.0 80.0 80.0 80.0<br />

TEMPERATURE RISE - DEG F 45-75 45-75 45-75 45-75 45-75 45-75 45-75<br />

UNIT VOLTAGE (NAMEPLATE) 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1<br />

ELECTRICAL UNIT AMPS (TOTAL) 21.5 23.6 23.6 23.6 31.4 31.4 31.4<br />

SPECIFICATION MIN CIRCUIT AMPACITY 27.7 30.0 30.0 30.0 38.4 38.4 38.4<br />

MAX OVERCURRENT PROTECTION 40 45 45 45 60 60 60<br />

HEATING NUMBER OF BURNERS 5 4 5 6 4 5 6<br />

SECTION ORIFICE SIZE NATURAL 43 43 43 43 43 43 43<br />

ORIFICE SIZE LP 55 55 55 55 55 55 55<br />

COMPRESSOR TYPE SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL<br />

RATED LOAD AMPS 16.5 18.3 18.3 18.3 25 25 25<br />

LOCKED ROTOR AMPS 95 109 109 109 169 169 169<br />

CONDENSER HORSEPOWER 1/3 1/3 1/3 1/3 1/3 1/3 1/3<br />

FAN MOTOR RPM 1100 1100 1100 1100 1100 1100 1100<br />

FULL LOAD AMPS 2.4 2.4 2.4 2.4 2.4 2.4 2.4<br />

LOCKED ROTOR AMPS 5.4 5.4 5.4 5.4 5.4 5.4 5.4<br />

CONDENSER BLADE DIAMETER / NUMBER 22 IN / 4 22 IN / 4 22 IN / 4 22 IN / 4 22 IN / 4 22 IN / 4 22 IN / 4<br />

FAN CFM 3000 3000 3000 3000 3000 3000 3000<br />

CONDENSER FACE AREA - SQ. FT. 12 12 12 12 12 12 12<br />

COIL NUMBER OF ROWS / FINS PER INCH 1 / 20 1 / 20 1 / 20 1 / 20 2 / 20 2 / 20 2 / 20<br />

EVAPORATOR HORSEPOWER - NO. OF SPEEDS 3/4 - 3 3/4 - 3 3/4 - 3 3/4 - 3 3/4 - 3 3/4 - 3 3/4 - 3<br />

BLOWER FULL LOAD AMPS 4.7 4.7 4.7 4.7 4.7 4.7 4.7<br />

MOTOR LOCKED ROTOR AMPS 12.2 12.2 12.2 12.2 12.2 12.2 12.2<br />

MOTOR SPEED TAP - COOLING LOW MED MED MED HIGH HIGH HIGH<br />

RPM / AMPS 840 / 3.0 920 / 3.3 920 / 3.3 920 / 3.3 1070 / 4.4 1070 / 4.4 1070 / 4.4<br />

EVAPORATOR DIAMETER X WIDTH (INCHES) 11 X 10 11 X 10 11 X 10 11 X 10 11 X 10 11 X 10 11 X 10<br />

BLOWER RATED SCFM COOLING 1400 1600 1600 1600 2000 2000 2000<br />

MAX EXTERNAL STATIC PRESS .5"wc .5"wc .5"wc .5"wc .5"wc .5"wc .5"wc<br />

EVAPORATOR FACE AREA - SQ. FT. 5.2 5.2 5.2 5.2 5.2 5.2 5.2<br />

COIL NUMBER OF ROWS / FINS PER INCH 3 / 14 4 / 14 4 / 14 4 / 14 4 / 14 4 / 14 4 / 14<br />

DRAIN SIZE 3/4 IN 3/4 IN 3/4 IN 3/4 IN 3/4 IN 3/4 IN 3/4 IN<br />

GENERAL EXPANSION DEVICE ORIFICE ORIFICE ORIFICE ORIFICE ORIFICE ORIFICE ORIFICE<br />

INFORMATION REFRIGERANT CHARGE R-22 86 OZ 91 OZ 91 OZ 91 OZ 139 OZ 139 OZ 139 OZ<br />

POWER SUPPLY ENTRANCE SIZE 3/4 1-1/4 3/4 1-1/4 3/4 1-1/4 3/4 1-1/4 3/4 1-1/4 3/4 1-1/4 3/4 1-1/4<br />

LOW VOLTAGE ENTRANCE SIZE 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2"<br />

SHIPPING WEIGHT LBS. 465 461 467 473 478 484 490<br />

OPERATING WEIGHT LBS. 445 441 447 453 458 464 470<br />

ACCESSORIES PROPANE GAS CONVERSION KIT LPTK09 LPTK09 LPTK09 LPTK09 LPTK09 LPTK09 LPTK09<br />

COMPRESSOR SOUND BLANKET CSB08A CSB08A CSB08A CSB08A CSB09A CSB09A CSB09A<br />

HORIZONTAL DUCT COVER KIT(2 COVERS) CHK002A CHK002A CHK002A N/A 2 CHK002A CHK002A N/A 2<br />

OVER / UNDER DUCT CONVERSION KIT PDTROU4A PDTROU4A PDTROU4A PDTROU4A PDTROU4A PDTROU4A PDTROU4A<br />

1<br />

Units installed in Canada are certified only to 4500 feet.<br />

2<br />

PGB48C140 and PGB<strong>60C</strong>140 are not approved for use<br />

through bottom discharge openings.<br />

Part No. 11131523 Rev. 5<br />

Printed in USA<br />

Goodman Company, L.P.<br />

1810 Wilson Parkway • Fayetteville, Tennessee 37334<br />

www.amana-hac.com<br />

May 2003


CAUTION<br />

The installation must be adjusted to obtain a temperature rise within the range listed on<br />

the unit nameplate.<br />

Clearances<br />

WARNING<br />

To avoid death, personal injury or property damage due to fire, clearances to combustible<br />

surfaces listed as shown must be observed.<br />

Propane Gas Conversion Chart<br />

Model<br />

PGB**C***2E<br />

PGB**C***2E<br />

Gas<br />

Natural<br />

Propane<br />

Natural<br />

Propane<br />

Altitude<br />

(Feet)<br />

0 - 6000<br />

Kit<br />

None<br />

LPTK09<br />

6001 - 11000<br />

HANG07<br />

HALP09<br />

Orifice<br />

#43<br />

#55<br />

#45<br />

#56<br />

Manifold<br />

Pressure<br />

3.5" W.C<br />

10.0" W.C.<br />

3.5" W.C<br />

10.0" W.C.<br />

NOTE: In Canada, gas furnaces are certified to 4,500<br />

feet only.<br />

24" Clearance<br />

(Condenser End)<br />

36"<br />

Maximum<br />

Overhang<br />

48" Minimum<br />

36" Side Overhang<br />

Clearance<br />

for Servicing<br />

Recommended<br />

Vinyl Coated<br />

Canvas<br />

Connections<br />

Insulated<br />

Return<br />

Duct<br />

2-15/16"<br />

47-5/32"<br />

Minimum 9" Clearance<br />

to Combustibles<br />

36" Clearance for<br />

Service Required<br />

0" Minimum<br />

Clearance to<br />

Combustibles<br />

Insulated<br />

<strong>Supply</strong><br />

Duct<br />

NOTES:<br />

1. All units are manufactured for use on 208/230<br />

VAC, 60 Hz, single phase electrical supply.<br />

20-3/8"<br />

4-15/32"<br />

6-5/8"<br />

2-3/8"<br />

Electrical Only<br />

(Bottom Of Unit)<br />

(3/4", 1-1/4" K.O.)<br />

Center of<br />

Gravity<br />

BOTTOM DUCT<br />

OPENING<br />

(SUPPLY)<br />

20-3/16"<br />

Inside<br />

BOTTOM DUCT<br />

OPENING<br />

(RETURN)<br />

10"<br />

Inside<br />

6-15/16"<br />

28-1/8"<br />

42-11/16"<br />

20"<br />

(Inside)<br />

3-1/2"<br />

5-5/16"<br />

25-3/8"<br />

49-3/16"<br />

2. IMPORTANT: While the data is presented as a<br />

guide, it is required to determine the proper size<br />

fuses and wires to electrically connect the unit in<br />

accordance with the National Electrical Code and/<br />

or all existing local codes.<br />

3. Performance figures are based on Department of<br />

Energy information and requirements under continuous<br />

operating conditions. Performance will<br />

vary with weather conditions and use.<br />

Electrical Only<br />

(3/4", 1-1/4" K.O.)<br />

Exhaust<br />

Flue<br />

Electrical Only<br />

(3/4", 1-1/4" K.O.)<br />

36-7/16"<br />

27-35/64"<br />

1-7/8"<br />

SUPPLY<br />

AIR<br />

(Shipped With<br />

Covers In Place)<br />

RETURN<br />

AIR<br />

(Shipped With<br />

Covers In Place)<br />

1-7/16"<br />

18"<br />

Combustion<br />

Air Intake<br />

3/4" Condensate<br />

Drain Connection<br />

Gas<br />

Low<br />

Voltage<br />

1/2"<br />

17-3/32"<br />

27-35/64"<br />

1-1/2"<br />

16" 16"<br />

5-3/8"<br />

43-1/16"<br />

(Inside Rail)<br />

1-11/64"<br />

1-1/8"<br />

Diameter<br />

Hole<br />

1-29/64"<br />

13-29/64"<br />

15-25/32"<br />

4-9/32"<br />

2


WARNING<br />

To prevent death, personal injury or property damage due to electrical shock, disconnect electrical power to this furnace<br />

before servicing or performing maintenance.<br />

CONTROL BOARD<br />

(TERMINAL ORDER REARRANGED)<br />

11<br />

10<br />

C H<br />

O E<br />

N<br />

N O A D N<br />

T F<br />

9 T<br />

2 8 S 3 5<br />

FAN<br />

COM<br />

CAP<br />

HERM<br />

OD<br />

FAN<br />

ACB<br />

R<br />

S<br />

COMP<br />

C<br />

COMB<br />

BLOWER<br />

T1 T2<br />

CC<br />

L1 GND<br />

L2<br />

MODELS<br />

<strong>PGB42</strong>C1152E<br />

PGB48C0902E<br />

PGB48C1152E<br />

PGB48C1402E<br />

PGB<strong>60C</strong>0902E<br />

PGB<strong>60C</strong>1152E<br />

PGB<strong>60C</strong>1402E<br />

2<br />

3<br />

0<br />

2 X<br />

4 F<br />

M<br />

V R<br />

WARNING:DISCONNECT POWER BEFORE SERVICING.<br />

PS<br />

NC<br />

N0<br />

C<br />

L<br />

M<br />

T<br />

M<br />

T<br />

RL<br />

COMBUSTION<br />

BLOWER<br />

(CB)<br />

TRANSFORMER<br />

COM<br />

LINE<br />

208 230<br />

LOAD<br />

IMPORTANT:<br />

PRIMARY ROLLOUT<br />

LIMIT (RL)<br />

AIR PRESSURE<br />

SWITCH (PS)<br />

NC<br />

NO<br />

COM<br />

LIMIT<br />

AIR<br />

CIRCULATION<br />

BLOWER<br />

(ACB)<br />

CAPACITOR<br />

(CAP)<br />

AUX LIMIT<br />

CONTROL<br />

S<br />

R<br />

C<br />

COMPRESSOR<br />

1 WIRING<br />

FIELD CONNECTION<br />

208/230 VAC 1Ø<br />

GND<br />

20261201 REV. 2<br />

YL YELLOW<br />

OR ORANGE<br />

VT VIOLET<br />

GN GREEN<br />

BK BLACK<br />

COM<br />

HERM<br />

FAN<br />

O.D.<br />

FAN<br />

MOTOR<br />

WARNING:DISCONNECT POWER<br />

BEFORE SERVICING.<br />

COLOR CODE<br />

BR BROWN<br />

WH WHITE<br />

BU BLUE<br />

GY GRAY<br />

RD RED<br />

LOW VOLTAGE<br />

LOW VOLTAGE FIELD<br />

HI VOLTAGE<br />

HI VOLTAGE FIELD<br />

T<br />

C<br />

A<br />

P<br />

A<br />

C<br />

2<br />

0<br />

8<br />

C<br />

O<br />

M<br />

CC<br />

208/230 VAC 1Ø<br />

A<br />

U<br />

X<br />

L<br />

C<br />

A<br />

P<br />

FACTORY WIRED MOTOR CONNECTIONS<br />

MOTOR<br />

SPEEDS<br />

3<br />

3<br />

3<br />

3<br />

C<br />

O<br />

M<br />

3<br />

3<br />

3<br />

* HEATING BLOWER SPEED<br />

SPEED<br />

MOTOR TO "HEAT"<br />

MED BU-23<br />

LOW RD-24<br />

MED BU-23<br />

HI BK-26<br />

LOW RD-24<br />

MED BU-23<br />

HI BK-26<br />

208 VOLT INSTALLATION<br />

FOR PROPER OPERATION ON 208 VOLT THE<br />

FOLLOWING CHANGES MUST BE MADE:<br />

MOVE BK17 WIRE FROM TRANSFORMER<br />

230 TERMINAL TO 208 TERMINAL.<br />

RD<br />

(230)<br />

VT<br />

(COM)<br />

** COOLING BLOWER SPEED<br />

SPEED MOTOR TO "COOL"<br />

LOW RD-24<br />

MED BU-23<br />

MED BU-23<br />

MED BU-23<br />

HI BK-26<br />

HI BK-26<br />

HI BK-26<br />

BR-21<br />

VT-14<br />

OR-49<br />

RD-24<br />

BU-23<br />

BK-26<br />

OR-22<br />

1. AMANA SPECIFIED REPLACEMENT PARTS MUST BE<br />

USED WHEN SERVICING<br />

2. IF ANY ORIGINAL WIRE IS REPLACED, 105 °C WIRE MUST<br />

BE USED.USE COPPER CONDUCTORS ONLY.<br />

3. EQUIPPED FOR 230 VOLT OR 208 VOLT.<br />

4. HEAT ON/OFF FAN DELAY FACTORY SETTINGS: 30<br />

SECONDS ON AND 120 SECONDS OFF.<br />

5. UNUSED BLOWER MOTOR LEADS MUST BE PLACED ON<br />

OR-19<br />

7. COOLING /FAN ONLY ON/OFF FAN DELAY SETTING: 7 SECONDS ON<br />

AND 30 SECONDS OFF.<br />

6<br />

5<br />

4<br />

3<br />

2<br />

3<br />

0<br />

L<br />

P<br />

S<br />

DSI<br />

M<br />

C<br />

FS<br />

6<br />

WH<br />

WH<br />

3 2 1<br />

6 5 4<br />

9 8 7<br />

12 11 10<br />

DETAIL 1<br />

GY<br />

25<br />

RD<br />

1<br />

GY-70<br />

YL-11<br />

VT-18<br />

RD<br />

YL<br />

WH<br />

GN<br />

R<br />

Y<br />

W<br />

G<br />

C<br />

RD-29<br />

2<br />

1<br />

DIRECT SPARK<br />

IGNITOR (DSI)<br />

BR BR<br />

VT-34<br />

GY-25<br />

VT<br />

37<br />

RD<br />

13<br />

L2 L1 GND<br />

L1<br />

YL-12<br />

VT<br />

16<br />

BR<br />

11<br />

L2 T2<br />

T1<br />

BK<br />

27<br />

RD<br />

10<br />

VT<br />

20<br />

O<br />

R<br />

RD<br />

15<br />

VT<br />

16<br />

L<br />

1<br />

7<br />

1<br />

2<br />

3<br />

L<br />

1<br />

1<br />

2<br />

1<br />

L<br />

I<br />

6<br />

1<br />

I<br />

I<br />

I<br />

I<br />

4<br />

I<br />

090<br />

120<br />

150<br />

G<br />

C<br />

N<br />

L2 L2 L2 L2<br />

BK<br />

17<br />

COOL HEAT UNUSED L1 L1 D1<br />

VT-47<br />

FS<br />

T1<br />

OR<br />

GY-25<br />

READ BEFORE OPERATING OR SERVICING THIS<br />

UNIT WARNING: DISCONNECT POWER BEFORE<br />

SERVICING.<br />

GAS VALVE<br />

(GV)<br />

8. DIAGNOSTIC LIGHT: STEADY ON= STANDBY MODE;<br />

STEADY OFF= INTERNAL FAULT OR NO POWER; 1<br />

FLASH= LOCKOUT; 2 FLASHES= PS STUCK OPEN;<br />

3 FLASHES= PS STUCK CLOSED; 4 FLASHES=<br />

OPEN HIGH LIMIT SWITCH, AUX LIMIT SWITCH,<br />

OR OPEN ROLL OUT; 5 FLASHES= FLAME<br />

DETECTED WITH GAS VALVE CLOSED; 6<br />

FLASHES= COMPRESSOR DELAYED ON SHORT<br />

CYCLE TIMER;7 FLASHES = LOW FLAME SENSE<br />

CURRENT; 8 FLASHES = 5 LIMIT TRIPS WITHIN A<br />

SINGLE CALL FOR HEAT.<br />

9. COMPRESSOR SHORT CYCLE DELAY: 3 MIN.<br />

STARTUP DELAY AFTER POWER LOSS.<br />

DETAIL 1<br />

ADJUSTABLE FAN SETTING<br />

(FACTORY SETTING AS SHOWN)<br />

YL/BK<br />

LOW PRESSURE<br />

SWITCH<br />

4<br />

M<br />

C<br />

P<br />

1<br />

2<br />

3<br />

Y<br />

W<br />

R<br />

THERMOSTAT<br />

GV<br />

BU-36<br />

THERMOSTAT<br />

UNUSED MOTOR TERMINALS OF CONTROL OR TAPED.<br />

6. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE<br />

SAME DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS.<br />

FLAME<br />

SENSOR<br />

3


Dry Coil Data (Horizontal)<br />

<strong>PGB42</strong>C1152E<br />

UNIT<br />

LOW<br />

MEDIUM<br />

HIGH<br />

STATIC CFM WATTS RISE CFM WATTS RISE CFM WATTS RISE<br />

0.2 1450 695 59 1755 825 49 2350 1125 NR<br />

0.3 1430 680 60 1715 800 50 2260 1085 NR<br />

0.4 1405 665 61 1675 775 51 2175 1045 NR<br />

0.5 1385 650 62 1620 745 53 2085 1005 NR<br />

0.6 1360 625 63 1560 715 55 1990 965 NR<br />

0.7 1315 610 65 1515 680 56 1910 930 45<br />

0.8 1265 590 67 1430 645 60 1805 885 47<br />

PGB48C0902E/PGB<strong>60C</strong>0902E<br />

UNIT<br />

STATIC CFM<br />

LOW<br />

WATTS RISE CFM<br />

MEDIUM<br />

WATTS RISE CFM<br />

HIGH<br />

WATTS RISE<br />

0.2 1440 680 47 1725 800 NR 2270 1085 NR<br />

0.3 1420 665 48 1685 775 NR 2185 1045 NR<br />

0.4 1400 650 49 1630 745 NR 2095 1005 NR<br />

0.5 1370 625 50 1570 715 NR 2000 970 NR<br />

0.6 1325 610 51 1525 680 45 1920 930 NR<br />

0.7 1275 590 53 1440 645 47 1815 885 NR<br />

0.8 1225 555 56 1350 610 51 1705 840 NR<br />

PGB48C1152E/PGB<strong>60C</strong>1152E<br />

UNIT<br />

LOW MEDIUM HIGH<br />

STATIC CFM WATTS RISE CFM WATTS RISE CFM WATTS RISE<br />

0.2 1435 680 59 1720 800 50 2265 1085 NR<br />

0.3 1415 665 60 1680 775 51 2180 1045 NR<br />

0.4 1395 650 61 1625 745 52 2090 1005 NR<br />

0.5 1365 625 62 1565 715 54 1995 970 NR<br />

0.6 1320 610 65 1520 680 56 1915 930 45<br />

0.7 1270 590 67 1435 645 59 1810 885 47<br />

0.8 1220 555 70 1345 610 63 1700 840 50<br />

PGB48C1402E/PGB<strong>60C</strong>1402E<br />

UNIT<br />

LOW MEDIUM HIGH<br />

STATIC CFM WATTS RISE CFM WATTS RISE CFM WATTS RISE<br />

0.2 1430 680 72 1715 800 60 2260 1085 45<br />

0.3 1405 665 73 1675 775 61 2175 1045 47<br />

0.4 1385 650 74 1620 745 63 2085 1005 49<br />

0.5 1360 625 75 1560 715 66 1990 965 51<br />

0.6 1315 610 NR 1515 680 68 1910 930 54<br />

0.7 1265 590 NR 1430 645 72 1805 885 57<br />

0.8 1210 555 NR 1340 610 NR 1695 840 60<br />

NR Not Recommended<br />

CAUTION<br />

The installation must be adjusted to obtain<br />

a temperature rise within the range<br />

listed on the unit nameplate.<br />

4


Dry Coil Data (Downshot)<br />

<strong>PGB42</strong>C1152E<br />

UNIT<br />

LOW<br />

MEDIUM<br />

HIGH<br />

STATIC CFM WATTS RISE CFM WATTS RISE CFM WATTS RISE<br />

0.2 1320 625 65 1540 700 55 1780 895 48<br />

0.3 1290 610 66 1480 675 58 1740 870 49<br />

0.4 1270 600 67 1410 645 60 1645 845 52<br />

0.5 1245 570 68 1340 630 64 1585 835 54<br />

0.6 1190 550 72 1295 600 66 1520 800 56<br />

0.7 1135 540 75 1245 580 68 1435 775 59<br />

0.8 1075 520 NR 1190 565 72 1390 765 61<br />

PGB48C0902E<br />

UNIT<br />

STATIC CFM<br />

LOW<br />

WATTS RISE CFM<br />

MEDIUM<br />

WATTS RISE CFM<br />

HIGH<br />

WATTS RISE<br />

0.2 1300 610 52 1490 665 46 1750 870 NR<br />

0.3 1280 600 53 1420 645 48 1655 845 NR<br />

0.4 1255 570 54 1350 630 51 1595 835 NR<br />

0.5 1200 550 57 1300 600 52 1530 800 45<br />

0.6 1145 540 60 1250 580 55 1445 775 47<br />

0.7 1085 520 63 1200 565 57 1400 765 49<br />

0.8 1025 505 67 1145 540 60 1330 735 51<br />

PGB48C1152E<br />

UNIT<br />

LOW<br />

MEDIUM<br />

HIGH<br />

STATIC CFM WATTS RISE CFM WATTS RISE CFM WATTS RISE<br />

0.2 1295 610 66 1485 665 57 1745 870 49<br />

0.3 1275 600 67 1415 645 60 1650 845 52<br />

0.4 1250 570 68 1345 630 63 1590 835 54<br />

0.5 1195 550 71 1295 600 66 1525 800 56<br />

0.6 1140 540 75 1245 580 68 1440 775 59<br />

0.7 1080 520 NR 1195 565 71 1395 765 61<br />

0.8 1020 505 NR 1140 540 75 1325 735 64<br />

NR Not Recommended<br />

PGB48C1402E and PGB<strong>60C</strong>****E are NOT approved for use through the bottom<br />

discharge openings.<br />

CAUTION<br />

The installation must be adjusted to obtain<br />

a temperature rise within the range<br />

listed on the unit nameplate.<br />

5


Typical Cooling Performance Data<br />

CAUTION<br />

The installation must be adjusted to obtain a temperature rise within the range listed on the<br />

unit nameplate.<br />

<strong>PGB42</strong>C1152E<br />

Outdoor Ambient Temperature (°F)<br />

65 75 85 95 105 115<br />

Entering Indoor Wet Bulb Temperature (°F)<br />

IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71<br />

∆T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 15 12 - 17 14 11 -<br />

1500 AMPS 17.9 18.1 18.5 - 18.7 19.0 19.3 - 19.7 20.0 20.4 - 20.5 20.8 21.3 - 21.4 21.7 22.2 - 22.2 22.5 23.1 -<br />

HI PR 167 179 189 - 187 201 212 - 213 229 242 - 242 261 275 - 272 293 310 - 301 324 342 -<br />

LO PR 65 69 76 - 69 73 80 - 72 76 83 - 75 80 87 - 79 84 92 - 82 87 95 -<br />

∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -<br />

70 1400 AMPS 17.8 18.1 18.4 - 18.7 18.9 19.3 - 19.6 19.9 20.3 - 20.5 20.8 21.2 - 21.3 21.7 22.1 - 22.1 22.5 23.0 -<br />

HI PR 166 179 189 - 186 201 212 - 212 228 241 - 241 260 274 - 272 292 309 - 300 323 341 -<br />

LO PR 65 69 76 - 69 73 80 - 71 76 83 - 75 80 87 - 79 84 91 - 81 87 95 -<br />

∆T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 12 - 18 15 12 -<br />

1300 AMPS 17.7 17.9 18.3 - 18.5 18.8 19.1 - 19.4 19.7 20.1 - 20.3 20.6 21.0 - 21.1 21.4 21.9 - 21.9 22.3 22.8 -<br />

HI PR 163 176 186 - 183 197 208 - 208 224 237 - 237 255 270 - 267 287 303 - 295 318 335 -<br />

LO PR 64 68 74 - 68 72 79 - 70 75 82 - 74 79 86 - 77 82 90 - 80 85 93 -<br />

∆T 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10<br />

1500 AMPS 18.0 18.2 18.6 19.0 18.8 19.1 19.5 19.9 19.8 20.1 20.5 21.0 20.6 21.0 21.4 21.9 21.5 21.8 22.3 22.9 22.3 22.7 23.2 23.8<br />

HI PR 168 181 191 200 189 203 215 224 215 231 244 255 245 263 278 290 275 296 313 326 304 327 346 360<br />

LO PR 66 70 77 82 70 74 81 86 72 77 84 90 76 81 88 94 80 85 93 99 82 88 96 102<br />

∆T 21 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10<br />

75 1400 AMPS 17.9 18.2 18.5 18.9 18.8 19.0 19.4 19.9 19.8 20.1 20.5 21.0 20.6 20.9 21.4 21.9 21.4 21.8 22.3 22.8 22.3 22.6 23.2 23.8<br />

HI PR 168 181 191 199 188 203 214 223 214 230 243 254 244 263 277 289 274 295 312 325 303 326 345 359<br />

LO PR 66 70 76 81 69 74 81 86 72 77 84 89 76 81 88 94 80 85 92 98 82 87 96 102<br />

∆T 22 20 16 11 22 20 17 11 22 20 17 11 22 20 17 12 22 20 17 11 20 19 15 11<br />

1300 AMPS 17.8 18.0 18.4 18.8 18.6 18.9 19.2 19.7 19.6 19.9 20.3 20.7 20.4 20.7 21.2 21.7 21.2 21.6 22.0 22.6 22.0 22.4 22.9 23.5<br />

HI PR 165 178 187 196 185 199 210 219 211 227 239 250 240 258 272 284 270 290 307 320 298 321 339 353<br />

LO PR 65 69 75 80 68 73 79 84 71 76 82 88 75 79 87 92 78 83 91 97 81 86 94 100<br />

∆T 23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 16 22 22 19 15 20 21 18 14<br />

1500 AMPS 18.0 18.3 18.7 19.1 18.9 19.2 19.6 20.0 19.9 20.2 20.6 21.1 20.8 21.1 21.5 22.1 21.6 22.0 22.5 23.0 22.5 22.8 23.4 24.0<br />

HI PR 170 183 193 202 191 205 217 226 217 234 247 257 247 266 281 293 278 299 316 330 307 331 349 364<br />

LO PR 67 71 77 82 70 75 82 87 73 78 85 91 77 82 89 95 81 86 94 100 83 89 97 103<br />

∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 23 23 20 16 21 21 19 15<br />

80 1400 AMPS 18.0 18.3 18.6 19.0 18.9 19.2 19.5 20.0 19.9 20.2 20.6 21.1 20.7 21.0 21.5 22.0 21.6 21.9 22.4 23.0 22.4 22.8 23.3 23.9<br />

HI PR 170 182 193 201 190 205 216 225 216 233 246 256 246 265 280 292 277 298 315 329 306 330 348 363<br />

LO PR 66 71 77 82 70 75 82 87 73 78 85 90 77 82 89 95 80 85 93 99 83 88 96 103<br />

∆T 24 23 20 16 25 24 21 16 25 24 21 16 25 24 21 17 24 23 20 16 23 22 19 15<br />

1300 AMPS 17.9 18.1 18.5 18.9 18.7 19.0 19.3 19.8 19.7 20.0 20.4 20.9 20.5 20.8 21.3 21.8 21.4 21.7 22.2 22.7 22.2 22.5 23.1 23.7<br />

HI PR 167 179 189 198 187 201 212 222 213 229 242 252 242 261 275 287 272 293 310 323 301 324 342 357<br />

LO PR 65 69 76 81 69 73 80 85 72 76 83 89 75 80 87 93 79 84 92 98 82 87 95 101<br />

*Entering Dry Bulb Temperature.<br />

NOTE: Darker shaded area with white lettering is ARI rating conditions, (95° ambient, 80° IDB + 67° IWB).<br />

Lighter shaded area with black lettering is ACCA rating conditions, (95° ambient, 75° IDB + 63° IWB).<br />

All Pressures are PSIG. All temperatures are in °F.<br />

Low and high pressure are measured at gauge port.<br />

Amps are total unit amps at a rated voltage of 230 VAC.<br />

6


Typical Cooling Performance Data<br />

CAUTION<br />

The installation must be adjusted to obtain a temperature rise within the range listed on the<br />

unit nameplate.<br />

PGB48C***2E<br />

Outdoor Ambient Temperature (°F)<br />

65 75 85 95 105 115<br />

Entering Indoor Wet Bulb Temperature (°F)<br />

IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71<br />

∆T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -<br />

1750 AMPS 19.1 19.4 19.9 - 20.2 20.5 21.0 - 21.3 21.7 22.2 - 22.4 22.8 23.3 - 23.4 23.8 24.4 - 24.4 24.9 25.5 -<br />

HI PR 174 188 198 - 196 211 222 - 223 239 253 - 253 273 288 - 285 307 324 - 315 339 358 -<br />

LO PR 65 69 76 - 69 73 80 - 72 76 83 - 75 80 87 - 79 84 92 - 82 87 95 -<br />

∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -<br />

70 1650 AMPS 19.1 19.4 19.8 - 20.1 20.4 20.9 - 21.3 21.7 22.2 - 22.3 22.7 23.3 - 23.4 23.8 24.4 - 24.4 24.8 25.5 -<br />

HI PR 174 187 198 - 195 210 222 - 222 239 252 - 253 272 287 - 284 306 323 - 314 338 357 -<br />

LO PR 65 69 76 - 69 73 80 - 71 76 83 - 75 80 87 - 79 84 91 - 81 87 95 -<br />

∆T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -<br />

1550 AMPS 18.9 19.2 19.6 - 19.9 20.2 20.7 - 21.1 21.4 21.9 - 22.1 22.5 23.0 - 23.1 23.5 24.1 - 24.1 24.5 25.2 -<br />

HI PR 171 184 194 - 192 206 218 - 218 235 248 - 248 267 282 - 279 301 318 - 309 332 351 -<br />

LO PR 64 68 74 - 68 72 79 - 70 75 82 - 74 79 86 - 77 82 90 - 80 85 93 -<br />

∆T 20 19 15 10 20 19 15 11 20 19 15 11 21 19 16 11 20 19 15 11 19 17 14 10<br />

1750 AMPS 19.2 19.5 20.0 20.5 20.3 20.6 21.1 21.6 21.5 21.9 22.4 23.0 22.5 22.9 23.5 24.1 23.6 24.0 24.6 25.3 24.6 25.1 25.7 26.4<br />

HI PR 176 190 200 209 198 213 225 234 225 242 255 266 256 276 291 303 288 310 327 341 318 342 362 377<br />

LO PR 66 70 77 82 70 74 81 86 72 77 84 90 76 81 88 94 80 85 93 99 82 88 96 102<br />

∆T 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10<br />

75 1650 AMPS 19.2 19.5 19.9 20.4 20.2 20.6 21.0 21.6 21.4 21.8 22.3 22.9 22.5 22.9 23.4 24.1 23.5 24.0 24.5 25.2 24.6 25.0 25.6 26.4<br />

HI PR 176 189 200 208 197 212 224 234 224 241 255 266 255 275 290 303 287 309 326 340 317 341 361 376<br />

LO PR 66 70 76 81 69 74 81 86 72 77 84 89 76 81 88 94 80 85 92 98 82 87 96 102<br />

∆T 21 19 16 11 21 20 16 11 21 20 16 11 21 20 16 11 21 19 16 11 20 18 15 10<br />

1550 AMPS 19.0 19.3 19.7 20.2 20.0 20.4 20.8 21.4 21.2 21.6 22.1 22.7 22.2 22.6 23.2 23.8 23.3 23.7 24.3 24.9 24.3 24.7 25.3 26.1<br />

HI PR 173 186 196 205 194 208 220 230 220 237 250 261 251 270 285 297 282 304 321 335 312 336 354 370<br />

LO PR 65 69 75 80 68 73 79 84 71 76 82 88 75 79 87 92 78 83 91 97 81 86 94 100<br />

∆T 22 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 21 22 19 15 20 20 18 14<br />

1750 AMPS 19.4 19.7 20.1 20.6 20.4 20.7 21.2 21.8 21.6 22.0 22.5 23.1 22.7 23.1 23.6 24.3 23.7 24.2 24.8 25.5 24.8 25.2 25.9 26.6<br />

HI PR 178 191 202 211 200 215 227 237 227 244 258 269 259 278 294 307 291 313 331 345 321 346 365 381<br />

LO PR 67 71 77 82 70 75 82 87 73 78 85 91 77 82 89 95 81 86 94 100 83 89 97 103<br />

∆T 23 22 19 15 23 22 20 16 23 22 20 16 24 23 20 16 23 22 19 16 21 21 18 14<br />

80 1650 AMPS 19.3 19.6 20.1 20.6 20.4 20.7 21.2 21.7 21.6 22.0 22.5 23.1 22.6 23.0 23.6 24.3 23.7 24.1 24.7 25.4 24.7 25.2 25.8 26.6<br />

HI PR 177 191 202 210 199 214 226 236 226 244 257 268 258 277 293 306 290 312 330 344 320 345 364 380<br />

LO PR 66 71 77 82 70 75 82 87 73 78 85 90 77 82 89 95 80 85 93 99 83 88 96 103<br />

∆T 23 22 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 18 15<br />

1550 AMPS 19.1 19.4 19.9 20.4 20.2 20.5 21.0 21.5 21.3 21.7 22.2 22.8 22.4 22.8 23.3 24.0 23.4 23.8 24.4 25.1 24.4 24.9 25.5 26.2<br />

HI PR 174 188 198 207 196 211 222 232 223 239 253 264 253 273 288 300 285 307 324 338 315 339 358 373<br />

LO PR 65 69 76 81 69 73 80 85 72 76 83 89 75 80 87 93 79 84 92 98 82 87 95 101<br />

*Entering Dry Bulb Temperature.<br />

NOTE: Darker shaded area with white lettering is ARI rating conditions, (95° ambient, 80° IDB + 67° IWB).<br />

Lighter shaded area with black lettering is ACCA rating conditions, (95° ambient, 75° IDB + 63° IWB).<br />

All Pressures are PSIG. All temperatures are in °F.<br />

Low and high pressure are measured at gauge port.<br />

Amps are total unit amps at a rated voltage of 230 VAC.<br />

7


Typical Cooling Performance Data<br />

CAUTION<br />

The installation must be adjusted to obtain a temperature rise within the range listed on the<br />

unit nameplate.<br />

PGB<strong>60C</strong>***2E<br />

Outdoor Ambient Temperature (°F)<br />

65 75 85 95 105 115<br />

Entering Indoor Wet Bulb Temperature (°F)<br />

IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71<br />

∆T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 13 - 19 16 12 - 18 15 12 -<br />

2100 AMPS 25.7 26.1 26.6 - 27.0 27.4 28.0 - 28.5 29.0 29.6 - 29.8 30.4 31.1 - 31.2 31.7 32.5 - 32.5 33.0 33.8 -<br />

HI PR 173 186 196 - 194 208 220 - 220 237 250 - 251 270 285 - 282 304 321 - 312 336 354 -<br />

LO PR 63 67 73 - 67 71 77 - 69 74 80 - 73 77 85 - 76 81 89 - 79 84 92 -<br />

∆T 19 16 13 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 15 12 -<br />

70 2000 AMPS 25.6 26.0 26.6 - 27.0 27.4 28.0 - 28.5 28.9 29.6 - 29.8 30.3 31.0 - 31.1 31.6 32.4 - 32.4 33.0 33.8 -<br />

HI PR 172 185 196 - 193 208 219 - 220 236 250 - 250 269 284 - 281 303 320 - 311 335 353 -<br />

LO PR 63 67 73 - 66 71 77 - 69 73 80 - 73 77 84 - 76 81 88 - 79 84 91 -<br />

∆T 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 18 16 12 -<br />

1900 AMPS 25.4 25.8 26.4 - 26.7 27.2 27.8 - 28.2 28.7 29.4 - 29.5 30.0 30.7 - 30.8 31.4 32.1 - 32.1 32.7 33.5 -<br />

HI PR 170 183 193 - 191 205 217 - 217 233 246 - 247 266 281 - 278 299 316 - 307 330 349 -<br />

LO PR 62 66 72 - 66 70 76 - 68 73 79 - 72 76 83 - 75 80 87 - 78 83 90 -<br />

∆T 22 20 16 11 22 20 16 11 22 20 16 11 22 20 17 11 22 20 16 11 20 19 15 11<br />

2100 AMPS 25.8 26.2 26.8 27.4 27.2 27.6 28.2 28.9 28.7 29.2 29.8 30.6 30.0 30.5 31.3 32.1 31.4 31.9 32.7 33.6 32.7 33.3 34.1 35.0<br />

HI PR 174 188 198 207 196 211 222 232 222 239 253 264 253 273 288 300 285 307 324 338 315 339 358 373<br />

LO PR 64 68 74 79 67 72 78 83 70 74 81 87 74 78 85 91 77 82 89 95 80 85 93 99<br />

∆T 22 20 17 11 22 21 17 12 22 21 17 12 22 21 17 12 22 20 17 12 21 19 16 11<br />

75 2000 AMPS 25.8 26.2 26.7 27.4 27.1 27.5 28.1 28.8 28.7 29.1 29.8 30.6 30.0 30.5 31.2 32.0 31.3 31.9 32.6 33.5 32.6 33.2 34.0 34.9<br />

HI PR 174 187 198 206 195 210 222 231 222 239 252 263 253 272 287 299 284 306 323 337 314 338 357 372<br />

LO PR 64 68 74 79 67 71 78 83 70 74 81 86 73 78 85 91 77 82 89 95 79 85 92 98<br />

∆T 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 20 16 11<br />

1900 AMPS 25.6 26.0 26.5 27.2 26.9 27.3 27.9 28.6 28.4 28.9 29.5 30.3 29.7 30.2 30.9 31.8 31.0 31.6 32.3 33.2 32.3 32.9 33.7 34.6<br />

HI PR 172 185 195 203 193 207 219 228 219 236 249 259 249 268 283 296 281 302 319 332 310 334 352 367<br />

LO PR 63 67 73 78 66 71 77 82 69 73 80 85 72 77 84 89 76 81 88 94 78 83 91 97<br />

∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 24 20 16 23 23 20 16 21 21 19 15<br />

2100 AMPS 26.0 26.4 26.9 27.6 27.3 27.8 28.4 29.1 28.9 29.4 30.0 30.8 30.2 30.7 31.5 32.3 31.6 32.1 32.9 33.8 32.9 33.5 34.3 35.3<br />

HI PR 176 190 200 209 198 213 225 234 225 242 255 266 256 275 291 303 288 310 327 341 318 342 362 377<br />

LO PR 64 69 75 80 68 72 79 84 71 75 82 87 74 79 86 92 78 83 90 96 81 86 94 100<br />

∆T 25 24 20 16 25 24 21 17 25 24 21 17 25 24 21 17 24 24 21 16 22 22 19 15<br />

80 2000 AMPS 25.9 26.3 26.9 27.5 27.3 27.7 28.3 29.0 28.8 29.3 30.0 30.7 30.2 30.7 31.4 32.2 31.5 32.1 32.8 33.7 32.8 33.4 34.2 35.2<br />

HI PR 176 189 200 208 197 212 224 234 224 241 255 266 255 275 290 302 287 309 326 340 317 341 360 376<br />

LO PR 64 68 75 79 68 72 79 84 70 75 82 87 74 79 86 92 78 83 90 96 80 85 93 99<br />

∆T 25 24 21 17 26 25 21 17 26 25 21 17 26 25 22 17 25 24 21 17 23 23 20 16<br />

1900 AMPS 25.7 26.1 26.7 27.3 27.1 27.5 28.1 28.8 28.6 29.1 29.7 30.5 29.9 30.4 31.1 32.0 31.3 31.8 32.5 33.4 32.6 33.1 33.9 34.9<br />

HI PR 173 186 197 205 194 209 221 230 221 238 251 262 252 271 286 299 283 305 322 336 313 337 356 371<br />

LO PR 63 67 74 78 67 71 78 83 70 74 81 86 73 78 85 90 77 81 89 95 79 84 92 98<br />

*Entering Dry Bulb Temperature.<br />

NOTE: Darker shaded area with white lettering is ARI rating conditions, (95° ambient, 80° IDB + 67° IWB).<br />

Lighter shaded area with black lettering is ACCA rating conditions, (95° ambient, 75° IDB + 63° IWB).<br />

All Pressures are PSIG. All temperatures are in °F.<br />

Low and high pressure are measured at gauge port.<br />

Amps are total unit amps at a rated voltage of 230 VAC.<br />

is a trademark of Maytag Worldwide<br />

N.V. and is used under license to Goodman<br />

Company, L.P. All rights reserved.<br />

®<br />

8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!