14.01.2015 Views

Power Connector Systems

Power Connector Systems

Power Connector Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Power</strong> <strong>Connector</strong>s & Interconnection <strong>Systems</strong><br />

ELCON Drawer <strong>Connector</strong> Mounting (Continued)<br />

Strain Relief and Wire Dress<br />

If required, wires can be bundled together and supported<br />

with cable ties. Wires must not be stretched or confined in<br />

any way that would restrict the floating action of the connectors.<br />

Therefore, the wires must remain perpendicular to<br />

the connector and avoid an excessively sharp bend<br />

radius. The minimum recommended distance for the cable<br />

tie, and the minimum bend radius of a wire bundle are<br />

shown in the figure to the right.<br />

PCB Fixed Mounting<br />

When mounting to a PC board, the connector standoffs must be seated on the board. Hold-downs are recommended to<br />

ensure stability during the soldering procedure. PCB mount hole patterns are shown on the customer drawing specific to<br />

your ELCON Drawer connector.<br />

Flush PCB Mount Drawer <strong>Connector</strong>s<br />

.020 [0.51]<br />

Drawer <strong>Connector</strong>s with Cabled AC IN<br />

Cable Mounted Products<br />

PC Board (Ref)<br />

Wire<br />

<strong>Connector</strong><br />

Standoffs<br />

.020 [0.51]<br />

<strong>Connector</strong> Engagement<br />

To ensure proper mating of the connector when the power supply unit is fully engaged into the system, the gap between<br />

the pin and socket (shown as dimension “A” in the sketch below) must be within the limit specified in the customer<br />

drawing for your ELCON Drawer connector. Failure to meet this requirement may compromise contact wipe. Refer to<br />

the customer drawing for details. ELCON Drawer connectors are polarized and will only mate in the correct orientation<br />

(see sketch below).<br />

Rib in Guide<br />

Post Cavity<br />

Notch in<br />

Guide Post<br />

Catalog 1773096 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000<br />

Revised 7-07 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628<br />

specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013<br />

www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-1106-0803 UK: +44 (0) 800-267-666<br />