ECO - How it works<br />

In most residential as well as in commercial buildings, the operation of some devices might be disabeled a few minutes without<br />

inconvenience of comfort and functionality. Eco takes advantage of this by disconnecting „loads“ such as heating of rooms or hot water<br />

provision for short periodes. As soon as the consumer system being monitored is again drawing less power, users that had previously been<br />

disconnected are progressively reconnected and can continue operating.<br />

The overall result is a significantly more consistent power uptake by the entire monitored consuming system – the plant’s power<br />

requirement is reduced.<br />

Functions<br />

Sequence processor Series STEP-T8<br />

State machine<br />

< Sequence processor with 4x20 programm steps<br />

< Function of control inputs programmable<br />

< 7 operation modes<br />

< Remanent latch function (selectable)<br />

< 8 NO contact<br />

< 1 CO contact<br />

< Width 157,5mm<br />

< Installation design<br />

Control inputs Connections Connections<br />

Power pulse of<br />

an energy meter<br />

Synchronisation impulse<br />

Tariff change-over<br />

Synchronisation<br />

of the real time clock<br />

Disconnection<br />

all load<br />

24V direct current supply<br />

Ground<br />

RS485 interface (A=RS485+)<br />

RS485 interface (B=RS485-)<br />

RS485 interface (A=RS485+)<br />

RS485 interface (B=RS485-)<br />

Type STEP-T8 110VAC STEP-T8 230VAC<br />

28 29 30 31 32 33 34 35 36 37<br />

PWR SYNC TAR CLK MOFF<br />

49 50 51 52 53 54<br />

A B A B<br />

24V<br />

GND<br />

Art.No. (PQ1) 454002 454001<br />

Art.No. (PQ10) - -<br />

EAN13-Code 900866200365 900866200364<br />

Controls 4 button programming 4 button programming<br />

Outputs<br />

Connections<br />

Indicators (LEDs) Display • 8 LEDs for output status • AL/SYNC • Power Display • 8 LEDs for output status • AL/SYNC • Power<br />

Regelausgänge<br />

Sammelstörmeldung<br />

Functions<br />

Sequence processor with 4x20 programm steps<br />

7 operation modes selectable:<br />

MODE 0 (standard - factory default) • MODE 1 (power failure detection)<br />

• MODE 2 (start requirement) • MODE 3 (power failure detection and<br />

start requirement) • MODE 4 (standard with extended Stop-function) •<br />

MODE 5 (power failure detection with extended Stop-function) • MODE<br />

6 (start requirement with extended Stop-function) • MODE 7 (power<br />

failure detection and start requirement with extended Stop-function)<br />

Sequence processor with 4x20 programm steps<br />

7 operation modes selectable:<br />

MODE 0 (standard - factory default) • MODE 1 (power failure detection)<br />

• MODE 2 (start requirement) • MODE 3 (power failure detection and<br />

start requirement) • MODE 4 (standard with extended Stop-function) •<br />

MODE 5 (power failure detection with extended Stop-function) • MODE<br />

6 (start requirement with extended Stop-function) • MODE 7 (power<br />

failure detection and start requirement with extended Stop-function)<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

F<br />

8 9 10 11 12 13 14 15 16 17 18 19<br />

20<br />

time ranges<br />

0,1s to 59min 59,9sec (100ms resolution)<br />

1s to 99h 95min 59sec (1s resolution)<br />

0,1s to 59min 59,9sec (100ms resolution)<br />

1s to 99h 95min 59sec (1s resolution)<br />

factory default<br />

control input setting<br />

Control input I1: RESET<br />

Connected: galvanic separated; terminals 28-29<br />

Typ: S0 (DIN 43864); 15mA DC / 24V DC<br />

Control input I2: TRIGGER<br />

Connected: galvanic separated; terminals 30-31<br />

Typ: S0 (DIN 43864); 15mA DC / 24V DC<br />

Control input I3: STOP<br />

Connected: galvanic separated; terminals 32-33<br />

Typ: S0 (DIN 43864); 15mA DC / 24V DC<br />

Control input I1: RESET<br />

Connected: galvanic separated; terminals 28-29<br />

Typ: S0 (DIN 43864); 15mA DC / 24V DC<br />

Control input I2: TRIGGER<br />

Connected: galvanic separated; terminals 30-31<br />

Typ: S0 (DIN 43864); 15mA DC / 24V DC<br />

Control input I3: STOP<br />

Connected: galvanic separated; terminals 32-33<br />

Typ: S0 (DIN 43864); 15mA DC / 24V DC<br />

selectable Input functions RESTART / STEP BACK • MANUAL • PROGRAMME CHANCE RESTART / STEP BACK • MANUAL • PROGRAMME CHANCE<br />

Width 157,5mm<br />

Dimensions<br />

Supply<br />

110VAC<br />

terminals A1-A2<br />

230VAC<br />

terminals A1-A2<br />

Output<br />

8 potential free NO contact 230V AC, 3A<br />

1 potential free NC contact 230V AC, 3A<br />

8 potential free NO contact 230V AC, 3A<br />

1 potential free NC contact 230V AC, 3A<br />

Width 157,5mm 157,5mm<br />

Certificates CE CE<br />

Mechanical<br />

design<br />

Self-extinguishing plastic housing, IP rating IP40 • Mounted on DIN-Rail TS 35 in accordance with EN 60715 • Mounting position: any • Shockproof<br />

terminal connection according to VBG 4, IP rating IP20 • Tightening torque max. 1Nm<br />

Terminal capacity<br />

1 x 0,5 to 2,5mm² with/without multicore cable end • 2 x 0,5 to 1,5mm² with/without multicore cable end<br />

Ambient<br />

conditions<br />

Ambient temperature: 0 to 50°C (in accordance with IEC 60068-1) • Storage temperature: -25 to +70°C • Transport temperature: -25 to +70°C •<br />

relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) • Pollution degree: 2, if built in 3 (in accordance with IEC 60664-1)<br />