E1IM: DC current monitoring with adjustable thresholds, hysteresis and tripping delay.<br />

E3IM: AC/DC current monitoring with adjustable thresholds, hysteresis and tripping delay.<br />

Functions<br />

Sensing & Monitoring Relays Series ENYA<br />

Temperature monitoring<br />

OVER<br />

Overcurrent monitoring<br />

UNDER<br />

Undercurrent monitoring<br />

WIN<br />

Monitoring the window between Min and Max<br />

OVER+Latch<br />

Overcurrent monitoring with fault latch<br />

UNDER+Latch Undercurrent monitoring with fault latch<br />

WIN+Latch<br />

Monitoring the window between Min and Max with fault latch<br />

E1IU<br />

AC current monitoring with adjustable threshold and fixed hysteresis.<br />

E1IM E1IU Connections<br />

< Temperature monitoring of the motor winding for temperature sensors in accordance with DIN 44081<br />

< Maximum 6 PTC sensors<br />

< Short circuit monitoring of the thermistor line (selectable by means of terminals)<br />

< Optional evaluation of one thermal contact<br />

< Test function with integrated reset key<br />

< Rated isolated voltage on the sensor circuit up to 690V<br />

< 1 CO contact<br />

< Width 35mm<br />

< Installation design<br />

1~<br />

L<br />

N<br />

1~<br />

L<br />

N<br />

types<br />

E3TF01<br />

Li<br />

N<br />

Lk<br />

Li<br />

N<br />

Lk<br />

15<br />

R<br />

16 18<br />

11<br />

R<br />

12 14<br />

L<br />

N<br />

k<br />

I1<br />

15<br />

R<br />

16 18<br />

16 15<br />

A1 A2<br />

I2 I3<br />

25<br />

R<br />

26 28<br />

26 25<br />

18 28<br />

15<br />

16 18<br />

E3IM measuring range 100mA; 1A; 10A<br />

L<br />

N<br />

45mm<br />

k<br />

I1<br />

15<br />

R<br />

16 18<br />

16 15<br />

87mm<br />

A1<br />

I2<br />

25<br />

R<br />

26 28<br />

A2<br />

I3<br />

26 25<br />

18 28<br />

L<br />

N<br />

11<br />

12 14<br />

k<br />

I1<br />

15<br />

R<br />

16 18<br />

16 15<br />

A1 A2<br />

I2 I3<br />

25<br />

R<br />

26 28<br />

26 25<br />

18 28<br />

45mm<br />

87mm<br />

Connections<br />

Width 17,5mm Width 35mm Dimensions<br />

Art.No. (PQ1) 1341600<br />

Art.No. (PQ10) -<br />

EAN13-Code 900866200512<br />

Measured variable<br />

Measured range<br />

Measuring voltage<br />

Controls<br />

Indicators (LEDs)<br />

Functions<br />

Response value<br />

Release value<br />

Short circuit<br />

monitoring<br />

Fault latch<br />

Reset<br />

Supply<br />

Output<br />

Width<br />

Certificates<br />

Mechanical<br />

design<br />

Terminal capacity<br />

Ambient<br />

conditions<br />

Accessories -<br />

PTC (motortemperature)<br />

max. 6 PTC probes<br />

total resistance cold

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!