19.01.2015 Views

CALOREX DELTA SYSTEMS V4 #EB15E

CALOREX DELTA SYSTEMS V4 #EB15E

CALOREX DELTA SYSTEMS V4 #EB15E

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Delta System<br />

heat recovery, dehumidification and<br />

ventilation system designed for all<br />

indoor pools<br />

R<br />

Specialist designers and manufacturers of pool comfort control systems


Environmental Control<br />

A well designed indoor swimming pool will provide years<br />

of pleasure for its owner. The Delta range of heat recovery<br />

dehumidifiers are specifically designed to economically<br />

provide the environmental comfort and moisture related<br />

structural protection expected of such a pool.<br />

Calorex Delta system des<br />

Why Calorex<br />

Calorex is the Worlds leading<br />

manufacturer of swimming pool heat<br />

pumps and is renowned for its<br />

innovation, range and quality of<br />

product. a proud claim, backed by over<br />

thirty years of design, manufacture and<br />

operational experience with thousands<br />

of units operating in over 60 countries<br />

worldwide.<br />

What does it do<br />

The Delta, connected to a suitably sized<br />

boiler will provide the complete<br />

solution to humidity, water/air<br />

temperature control and fresh air<br />

demands.<br />

Our product is our reputation. And both are the best.


The Delta range is now further enhanced by<br />

introduction of the high capacity Delta 14 &<br />

16. Designed for commercial pools, the Delta<br />

14 and 16 are available with over 40<br />

different airflow and control panel<br />

configurations, allowing them to provide<br />

total flexibility for all shapes and sizes of<br />

plant rooms.<br />

Backward curved fans designed to operate<br />

against high external resistances are fitted<br />

as standard and the unit can be supplied<br />

with BMS for buildings with central control.<br />

gned for all indoor pools<br />

Humidity control<br />

In contrast to most buildings, indoor swimming pools<br />

constantly evaporate large volumes of moisture into the<br />

space around them. Unless this moisture is removed,<br />

humidity will rise creating an uncomfortable environment<br />

and structural/fabric damage. Totally self controlling, the<br />

Delta will remove this moisture and recover energy from it<br />

which is then re-used to assist water and air heating. By<br />

utilising this method, a heat cycle is created and energy<br />

costs are kept to a minimum.<br />

Pool water and air heating<br />

A majority of the heating needs are provided by heat<br />

recovery from the dehumidification process. Heat losses<br />

that cannot be recovered are provided for by inbuilt heat<br />

exchangers which are connected to hot water from a<br />

boiler. All necessary controls to accurately maintain stable<br />

temperatures are fitted as standard within the Delta. This<br />

ensures easy installation with a central user friendly<br />

control panel that will automatically interrelate to pool hall<br />

air, water and humidity needs.<br />

Fresh air/air handling<br />

The Delta range is provided with automatically modulating<br />

fresh/exhaust air. This alleviates potential build up of<br />

airborne chemicals, provides a greater degree of air<br />

temperature control during warm weather and allows a<br />

slight negative pressure to be created within the pool<br />

hall which will prevent migration of pool hall air to<br />

adjacent rooms.<br />

During the cold weather, energy will<br />

be recovered from exhausted air to<br />

reheat the fresh air supply. With<br />

models 4 to 16, this process will<br />

automatically reverse during hot<br />

weather to reject some excess<br />

energy to the exhaust air and<br />

consequently maintain a<br />

comfortable temperature within the<br />

building.<br />

Controls<br />

The Delta is fitted with easy to read<br />

humidistat, and air and water<br />

thermostats, each with LCD<br />

display of set point and<br />

actual measured data. A<br />

simple diagnostic light<br />

system allows the<br />

user to read the<br />

operational mode,<br />

and a 7 day timeclock<br />

controls<br />

Delta operation.<br />

All controls are<br />

located and easily<br />

viewed behind a<br />

hinged protective<br />

screen.


<strong>CALOREX</strong> <strong>DELTA</strong> SPECIFICATIONS<br />

MODEL 1 2 4 6 8 10 12 14<br />

16<br />

POOL AIR RECIRCULATION FAN<br />

Airflow m 3 /hr<br />

2500<br />

2600<br />

3000<br />

4000<br />

5000<br />

6000<br />

7000<br />

10000<br />

12000<br />

EXHAUST/FRESH AIR FAN<br />

Air flow m 3 /hr (stepped control)<br />

120-1200<br />

130-1300<br />

150-1500<br />

200-2000<br />

250-2500<br />

300-3000<br />

350-3500<br />

670-6700<br />

850-8500<br />

DEHUMIDIFICATION DUTY LITRES/HR @ 28°C/60% RH<br />

Total duty by heat pump & fresh air dilution<br />

9.8<br />

10.9<br />

12.5<br />

16.6<br />

20.8<br />

25<br />

29.2<br />

56.5<br />

62.4<br />

HEAT TO AIR KW<br />

Via heat pump (mode A )<br />

Via heat pump (mode B )<br />

Via LPHW @ 80°C<br />

Max available (Mode B + LPHW)<br />

1.3<br />

3.8<br />

20<br />

23.8<br />

1.5<br />

4.9<br />

22<br />

26.9<br />

1.4<br />

5.1<br />

25<br />

30.1<br />

1.5<br />

6.6<br />

30<br />

36.6<br />

1.6<br />

8<br />

35<br />

43<br />

2<br />

10<br />

38<br />

48<br />

2.5<br />

12.1<br />

42<br />

54.1<br />

6<br />

30<br />

85<br />

115<br />

7<br />

35<br />

90<br />

125<br />

HEAT TO POOL WATER KW<br />

Via heat pump (mode A )<br />

Via heat pump (mode B )<br />

Via LPHW @ 80°C<br />

Max available (Mode A + LPHW)<br />

4<br />

1.7<br />

10<br />

14<br />

5.5<br />

2.2<br />

10<br />

15.5<br />

5.8<br />

2.3<br />

10<br />

15.8<br />

8<br />

3<br />

15<br />

23<br />

10<br />

3.7<br />

15<br />

25<br />

12.5<br />

4.6<br />

30<br />

42.5<br />

15<br />

5.5<br />

30<br />

45<br />

35<br />

12<br />

65<br />

100<br />

43<br />

14<br />

65<br />

108<br />

COOLING DUTY<br />

Total kW<br />

Sensible kW<br />

*Summer fresh air cooling<br />

-3*<br />

-2*<br />

-4*<br />

-2.5*<br />

-4.2<br />

-2.94<br />

-5.5<br />

-3.85<br />

-6.7<br />

-4.7<br />

-8.4<br />

-5.9<br />

-10.1<br />

-7.1<br />

-23<br />

-13<br />

-28<br />

-15<br />

RECOMMENDED BOILER CAPACITY KW<br />

30<br />

32<br />

35<br />

45<br />

50<br />

65<br />

70<br />

150<br />

150<br />

TOTAL POWER CONSUMED (NOMINAL) KWH<br />

3.18<br />

3.84<br />

3.94<br />

5.12<br />

6.25<br />

7.8<br />

9.35<br />

15<br />

18<br />

Mode A = Recovered heat biased to pool water (pool water temperature not satisfied).<br />

Mode B = Recovered heat biased to pool hall air (pool water temperature satisfied).<br />

DIM mm<br />

Models<br />

1&2<br />

4, 6 & 8<br />

10 & 12<br />

14 & 16<br />

For accurate application sizing consult<br />

Calorex Heat Pumps Limited<br />

OPTIONS<br />

Model 1-6 single or three phase<br />

Model 8-16 three phase only<br />

Handed units<br />

Fan orientation<br />

RS485 thermostat compatibility<br />

HEIGHT<br />

WIDTH<br />

DEPTH<br />

WEIGHT kg<br />

1685<br />

1530<br />

654<br />

300/310<br />

1960<br />

1620<br />

704<br />

350/360<br />

/370<br />

1960<br />

1620<br />

854<br />

410/460<br />

2120<br />

2640<br />

1126<br />

954/1020<br />

R<br />

HEAT PUMP ASSOCIATION<br />

<strong>CALOREX</strong> HEAT PUMPS LIMITED<br />

The Causeway, Maldon, Essex, CM9 4XD United Kingdom<br />

Tel No. +44 (0) 1621 856611 Fax No. +44 (0) 1621 850871<br />

e.mail: sales@calorex.com web: www.calorex.com<br />

Delta/V.4