<strong>CALOREX</strong> <strong>DELTA</strong> SPECIFICATIONS<br />

MODEL 1 2 4 6 8 10 12 14<br />

16<br />

POOL AIR RECIRCULATION FAN<br />

Airflow m 3 /hr<br />

2500<br />

2600<br />

3000<br />

4000<br />

5000<br />

6000<br />

7000<br />

10000<br />

12000<br />

EXHAUST/FRESH AIR FAN<br />

Air flow m 3 /hr (stepped control)<br />

120-1200<br />

130-1300<br />

150-1500<br />

200-2000<br />

250-2500<br />

300-3000<br />

350-3500<br />

670-6700<br />

850-8500<br />

DEHUMIDIFICATION DUTY LITRES/HR @ 28°C/60% RH<br />

Total duty by heat pump & fresh air dilution<br />

9.8<br />

10.9<br />

12.5<br />

16.6<br />

20.8<br />

25<br />

29.2<br />

56.5<br />

62.4<br />

HEAT TO AIR KW<br />

Via heat pump (mode A )<br />

Via heat pump (mode B )<br />

Via LPHW @ 80°C<br />

Max available (Mode B + LPHW)<br />

1.3<br />

3.8<br />

20<br />

23.8<br />

1.5<br />

4.9<br />

22<br />

26.9<br />

1.4<br />

5.1<br />

25<br />

30.1<br />

1.5<br />

6.6<br />

30<br />

36.6<br />

1.6<br />

8<br />

35<br />

43<br />

2<br />

10<br />

38<br />

48<br />

2.5<br />

12.1<br />

42<br />

54.1<br />

6<br />

30<br />

85<br />

115<br />

7<br />

35<br />

90<br />

125<br />

HEAT TO POOL WATER KW<br />

Via heat pump (mode A )<br />

Via heat pump (mode B )<br />

Via LPHW @ 80°C<br />

Max available (Mode A + LPHW)<br />

4<br />

1.7<br />

10<br />

14<br />

5.5<br />

2.2<br />

10<br />

15.5<br />

5.8<br />

2.3<br />

10<br />

15.8<br />

8<br />

3<br />

15<br />

23<br />

10<br />

3.7<br />

15<br />

25<br />

12.5<br />

4.6<br />

30<br />

42.5<br />

15<br />

5.5<br />

30<br />

45<br />

35<br />

12<br />

65<br />

100<br />

43<br />

14<br />

65<br />

108<br />

COOLING DUTY<br />

Total kW<br />

Sensible kW<br />

*Summer fresh air cooling<br />

-3*<br />

-2*<br />

-4*<br />

-2.5*<br />

-4.2<br />

-2.94<br />

-5.5<br />

-3.85<br />

-6.7<br />

-4.7<br />

-8.4<br />

-5.9<br />

-10.1<br />

-7.1<br />

-23<br />

-13<br />

-28<br />

-15<br />

RECOMMENDED BOILER CAPACITY KW<br />

30<br />

32<br />

35<br />

45<br />

50<br />

65<br />

70<br />

150<br />

150<br />

TOTAL POWER CONSUMED (NOMINAL) KWH<br />

3.18<br />

3.84<br />

3.94<br />

5.12<br />

6.25<br />

7.8<br />

9.35<br />

15<br />

18<br />

Mode A = Recovered heat biased to pool water (pool water temperature not satisfied).<br />

Mode B = Recovered heat biased to pool hall air (pool water temperature satisfied).<br />

DIM mm<br />

Models<br />

1&2<br />

4, 6 & 8<br />

10 & 12<br />

14 & 16<br />

For accurate application sizing consult<br />

Calorex Heat Pumps Limited<br />

OPTIONS<br />

Model 1-6 single or three phase<br />

Model 8-16 three phase only<br />

Handed units<br />

Fan orientation<br />

RS485 thermostat compatibility<br />

HEIGHT<br />

WIDTH<br />

DEPTH<br />

WEIGHT kg<br />

1685<br />

1530<br />

654<br />

300/310<br />

1960<br />

1620<br />

704<br />

350/360<br />

/370<br />

1960<br />

1620<br />

854<br />

410/460<br />

2120<br />

2640<br />

1126<br />

954/1020<br />

R<br />

HEAT PUMP ASSOCIATION<br />

<strong>CALOREX</strong> HEAT PUMPS LIMITED<br />

The Causeway, Maldon, Essex, CM9 4XD United Kingdom<br />

Tel No. +44 (0) 1621 856611 Fax No. +44 (0) 1621 850871<br />

e.mail: sales@calorex.com web: www.calorex.com<br />

Delta/V.4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!