Environmental Control<br />
A well designed indoor swimming pool will provide years<br />
of pleasure for its owner. The Delta range of heat recovery<br />
dehumidifiers are specifically designed to economically<br />
provide the environmental comfort and moisture related<br />
structural protection expected of such a pool.<br />
Calorex Delta system des<br />
Why Calorex<br />
Calorex is the Worlds leading<br />
manufacturer of swimming pool heat<br />
pumps and is renowned for its<br />
innovation, range and quality of<br />
product. a proud claim, backed by over<br />
thirty years of design, manufacture and<br />
operational experience with thousands<br />
of units operating in over 60 countries<br />
worldwide.<br />
What does it do<br />
The Delta, connected to a suitably sized<br />
boiler will provide the complete<br />
solution to humidity, water/air<br />
temperature control and fresh air<br />
demands.<br />
Our product is our reputation. And both are the best.
The Delta range is now further enhanced by<br />
introduction of the high capacity Delta 14 &<br />
16. Designed for commercial pools, the Delta<br />
14 and 16 are available with over 40<br />
different airflow and control panel<br />
configurations, allowing them to provide<br />
total flexibility for all shapes and sizes of<br />
plant rooms.<br />
Backward curved fans designed to operate<br />
against high external resistances are fitted<br />
as standard and the unit can be supplied<br />
with BMS for buildings with central control.<br />
gned for all indoor pools<br />
Humidity control<br />
In contrast to most buildings, indoor swimming pools<br />
constantly evaporate large volumes of moisture into the<br />
space around them. Unless this moisture is removed,<br />
humidity will rise creating an uncomfortable environment<br />
and structural/fabric damage. Totally self controlling, the<br />
Delta will remove this moisture and recover energy from it<br />
which is then re-used to assist water and air heating. By<br />
utilising this method, a heat cycle is created and energy<br />
costs are kept to a minimum.<br />
Pool water and air heating<br />
A majority of the heating needs are provided by heat<br />
recovery from the dehumidification process. Heat losses<br />
that cannot be recovered are provided for by inbuilt heat<br />
exchangers which are connected to hot water from a<br />
boiler. All necessary controls to accurately maintain stable<br />
temperatures are fitted as standard within the Delta. This<br />
ensures easy installation with a central user friendly<br />
control panel that will automatically interrelate to pool hall<br />
air, water and humidity needs.<br />
Fresh air/air handling<br />
The Delta range is provided with automatically modulating<br />
fresh/exhaust air. This alleviates potential build up of<br />
airborne chemicals, provides a greater degree of air<br />
temperature control during warm weather and allows a<br />
slight negative pressure to be created within the pool<br />
hall which will prevent migration of pool hall air to<br />
adjacent rooms.<br />
During the cold weather, energy will<br />
be recovered from exhausted air to<br />
reheat the fresh air supply. With<br />
models 4 to 16, this process will<br />
automatically reverse during hot<br />
weather to reject some excess<br />
energy to the exhaust air and<br />
consequently maintain a<br />
comfortable temperature within the<br />
building.<br />
Controls<br />
The Delta is fitted with easy to read<br />
humidistat, and air and water<br />
thermostats, each with LCD<br />
display of set point and<br />
actual measured data. A<br />
simple diagnostic light<br />
system allows the<br />
user to read the<br />
operational mode,<br />
and a 7 day timeclock<br />
controls<br />
Delta operation.<br />
All controls are<br />
located and easily<br />
viewed behind a<br />
hinged protective<br />
screen.
<strong>CALOREX</strong> <strong>DELTA</strong> SPECIFICATIONS<br />
MODEL 1 2 4 6 8 10 12 14<br />
16<br />
POOL AIR RECIRCULATION FAN<br />
Airflow m 3 /hr<br />
2500<br />
2600<br />
3000<br />
4000<br />
5000<br />
6000<br />
7000<br />
10000<br />
12000<br />
EXHAUST/FRESH AIR FAN<br />
Air flow m 3 /hr (stepped control)<br />
120-1200<br />
130-1300<br />
150-1500<br />
200-2000<br />
250-2500<br />
300-3000<br />
350-3500<br />
670-6700<br />
850-8500<br />
DEHUMIDIFICATION DUTY LITRES/HR @ 28°C/60% RH<br />
Total duty by heat pump & fresh air dilution<br />
9.8<br />
10.9<br />
12.5<br />
16.6<br />
20.8<br />
25<br />
29.2<br />
56.5<br />
62.4<br />
HEAT TO AIR KW<br />
Via heat pump (mode A )<br />
Via heat pump (mode B )<br />
Via LPHW @ 80°C<br />
Max available (Mode B + LPHW)<br />
1.3<br />
3.8<br />
20<br />
23.8<br />
1.5<br />
4.9<br />
22<br />
26.9<br />
1.4<br />
5.1<br />
25<br />
30.1<br />
1.5<br />
6.6<br />
30<br />
36.6<br />
1.6<br />
8<br />
35<br />
43<br />
2<br />
10<br />
38<br />
48<br />
2.5<br />
12.1<br />
42<br />
54.1<br />
6<br />
30<br />
85<br />
115<br />
7<br />
35<br />
90<br />
125<br />
HEAT TO POOL WATER KW<br />
Via heat pump (mode A )<br />
Via heat pump (mode B )<br />
Via LPHW @ 80°C<br />
Max available (Mode A + LPHW)<br />
4<br />
1.7<br />
10<br />
14<br />
5.5<br />
2.2<br />
10<br />
15.5<br />
5.8<br />
2.3<br />
10<br />
15.8<br />
8<br />
3<br />
15<br />
23<br />
10<br />
3.7<br />
15<br />
25<br />
12.5<br />
4.6<br />
30<br />
42.5<br />
15<br />
5.5<br />
30<br />
45<br />
35<br />
12<br />
65<br />
100<br />
43<br />
14<br />
65<br />
108<br />
COOLING DUTY<br />
Total kW<br />
Sensible kW<br />
*Summer fresh air cooling<br />
-3*<br />
-2*<br />
-4*<br />
-2.5*<br />
-4.2<br />
-2.94<br />
-5.5<br />
-3.85<br />
-6.7<br />
-4.7<br />
-8.4<br />
-5.9<br />
-10.1<br />
-7.1<br />
-23<br />
-13<br />
-28<br />
-15<br />
RECOMMENDED BOILER CAPACITY KW<br />
30<br />
32<br />
35<br />
45<br />
50<br />
65<br />
70<br />
150<br />
150<br />
TOTAL POWER CONSUMED (NOMINAL) KWH<br />
3.18<br />
3.84<br />
3.94<br />
5.12<br />
6.25<br />
7.8<br />
9.35<br />
15<br />
18<br />
Mode A = Recovered heat biased to pool water (pool water temperature not satisfied).<br />
Mode B = Recovered heat biased to pool hall air (pool water temperature satisfied).<br />
DIM mm<br />
Models<br />
1&2<br />
4, 6 & 8<br />
10 & 12<br />
14 & 16<br />
For accurate application sizing consult<br />
Calorex Heat Pumps Limited<br />
OPTIONS<br />
Model 1-6 single or three phase<br />
Model 8-16 three phase only<br />
Handed units<br />
Fan orientation<br />
RS485 thermostat compatibility<br />
HEIGHT<br />
WIDTH<br />
DEPTH<br />
WEIGHT kg<br />
1685<br />
1530<br />
654<br />
300/310<br />
1960<br />
1620<br />
704<br />
350/360<br />
/370<br />
1960<br />
1620<br />
854<br />
410/460<br />
2120<br />
2640<br />
1126<br />
954/1020<br />
R<br />
HEAT PUMP ASSOCIATION<br />
<strong>CALOREX</strong> HEAT PUMPS LIMITED<br />
The Causeway, Maldon, Essex, CM9 4XD United Kingdom<br />
Tel No. +44 (0) 1621 856611 Fax No. +44 (0) 1621 850871<br />
e.mail: sales@calorex.com web: www.calorex.com<br />
Delta/V.4