Non-isolated Trigger Schematic<br />
USERS TRIGGER CIRCUIT<br />
CABLE SIDE<br />
POWER GROUND<br />
12V_POWER<br />
SYNC INPUT 2 (3.3V DRIVER)<br />
POWER GROUND<br />
12V POWER<br />
SYNC INPUT 2<br />
SYNC OUTPUT 2<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
9 1<br />
8 10<br />
7<br />
6<br />
12 11<br />
5<br />
4<br />
2<br />
3<br />
SYNC OUTPUT 2 (3.3V RECEIVER)<br />
HIROSE HR10A-10P-12S<br />
The non-isolated trigger circuit is connected to a Texas Instruments SN74LVC2G241 buffer/driver inside the camera. The required sync input<br />
current is less than 10uA and the maximum sync output current is 24mA. See the Texas Instruments SN74LVC2G241 for more detailed<br />
information.<br />