Multifamily houses with 15 private apartments, in each<br />

apartment: one <strong>ABB</strong>-<strong>Welcome</strong> audio indoor station with<br />

handset Fig. 18<br />

Calculation of consumption for system controller<br />

Device<br />

Indoor stations<br />

Number Consumer units<br />

Number x<br />

Consumer units<br />

<strong>ABB</strong>-<strong>Welcome</strong> audio indoor station with handset<br />

Audio outdoor station<br />

15 1 15<br />

<strong>ABB</strong>-<strong>Welcome</strong> audio outdoor station, 15gang<br />

System devices<br />

2 11 22<br />

<strong>ABB</strong>-<strong>Welcome</strong> door/light switch actuators 1 2 2<br />

Total number of consumer units<br />

must not exceed 65<br />

39<br />

The consumer units required are covered by the system<br />

controller. The maximum number of devices per internal bus<br />

line is not exceeded. No auxiliary power supply required.<br />

Multifamily houses with 10 private apartments, in each<br />

apartment: one <strong>ABB</strong>-<strong>Welcome</strong> audio indoor station with<br />

display and one <strong>ABB</strong>-<strong>Welcome</strong> audio indoor station with<br />

handset Fig. 19<br />

Calculation of consumption for system controller<br />

Device<br />

Indoor stations<br />

Number Consumer units<br />

Number x<br />

Consumer units<br />

<strong>ABB</strong>-<strong>Welcome</strong> audio indoor station with handset 10 1 10<br />

<strong>ABB</strong>-<strong>Welcome</strong> audio indoor station with display<br />

Audio outdoor station<br />

10 2 20<br />

<strong>ABB</strong>-<strong>Welcome</strong> audio outdoor station, 10gang<br />

Only for two indoor stations per apartment<br />

1 11 11<br />

Number of apartments with two<br />

<strong>ABB</strong>-<strong>Welcome</strong> audio indoor stations<br />

10 1 or 2: 2 20<br />

Total number of consumer units<br />

must not exceed 65<br />

61<br />

The required number of consumer units are covered by the<br />

system controller. The maximum number of devices per<br />

internal bus line is not exceeded. The maximum lenghth is<br />

100 m. No additional auxiliary power supply is necessary.<br />

26 Planning <strong>ABB</strong>-<strong>Welcome</strong> systems | <strong>User</strong> <strong>Manual</strong> <strong>ABB</strong>-<strong>Welcome</strong><br />

"1 or 2": If an <strong>ABB</strong>-<br />

<strong>Welcome</strong> audio indoor<br />

station with display is<br />

installed, please attach 2<br />

consumer units;<br />

otherwise attach only<br />

1 consumer unit.