Setting the address of the indoor station<br />

At the indoor stations the apartment is assigned via the setting<br />

of the address. Up to 99 apartments can be addressed within<br />

an <strong>ABB</strong>-<strong>Welcome</strong> system. Up to four indoor stations with equal<br />

rights can be located in each with the same address. The four<br />

indoor stations are called when the assigned doorbell pushbutton<br />

is pressed.<br />

The address of an indoor station (e.g. "15") is set with the<br />

aid of the rotary knobs "X10" and "X1" at the indoor stations,<br />

where "X10" specifies the tens digit (here "1") and "X1" the<br />

single digit (here "5"). The rotary knobs are located at the rear<br />

or outside of the indoor stations.<br />

Fig. 27<br />

Several outdoor stations with identical<br />

assignment<br />

STATION X10 X1<br />

2 0 2<br />

Apartment 02<br />

STATION X10 X1<br />

2 0 1<br />

Apartment 01<br />

40 Commissioning | <strong>User</strong> <strong>Manual</strong> <strong>ABB</strong>-<strong>Welcome</strong><br />

K10 K1<br />

2 0 1<br />

Outdoor station<br />

Left building<br />

Setting of the "standard outdoor station"<br />

For several outdoor stations in an <strong>ABB</strong>-<strong>Welcome</strong> system the<br />

"standard outdoor station" must be set on the indoor stations.<br />

Here the rotary knob STATION is set on the address of the<br />

standard outdoor station – between 1 and 4. The rotary knob<br />

is located at the rear or outside of the indoor stations.<br />

Setting of the main indoor station<br />

In each apartment the switch "M/S" must be activated on<br />

one indoor station. This means "M=ON". For additional<br />

indoor stations in the apartment the switch here must be on<br />

"M=OFF". The switch is located on the back or outside of the<br />

indoor stations.<br />

K10 K1<br />

1 0 1<br />

Apartment 01 A Apartment 01 A<br />

Apartment 02 B<br />

Apartment 02 B<br />

Outdoor station<br />

Gateway entrance<br />

K10 K1<br />

3 0 3<br />

Apartment 03 C Apartment 03 A<br />

Apartment 04 D<br />

Apartment 04 B<br />

Outdoor station<br />

Right building<br />

STATION X10 X1<br />

STATION X10 X1<br />

3 0 3<br />

Apartment 03<br />

3 0 4<br />

Apartment 04