26.01.2015 Views

Belt Conveyor Pull Rope Switch PAS

Belt Conveyor Pull Rope Switch PAS

Belt Conveyor Pull Rope Switch PAS

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Belt</strong> conveyor pull rope switch<br />

pas<br />

leaflet no. Kiepe 511


Application<br />

Kiepe <strong>Pull</strong> <strong>Rope</strong> <strong>Switch</strong>es, type <strong>PAS</strong> are used in conveyor systems<br />

and processing machines. The conveyor or machine can be shut<br />

down from all hazard points with one single <strong>PAS</strong> switch.<br />

The maximum length of the rope is 30 m (see attached diagram).<br />

Kiepe <strong>Pull</strong> <strong>Rope</strong> <strong>Switch</strong>es and accessories meet the requirements<br />

of safety authorities with respect to personnel safety and<br />

equipment (BGI 710).<br />

Operation<br />

Kiepe pull rope switches type <strong>PAS</strong> are actuated by pulling the rope<br />

or if the rope is broken or in slack condition. Both NC contacts are<br />

hence opened and the switch is mechanically latched.<br />

Reset Button button<br />

The reset button indicates the actual switch status<br />

(ON/1 or OFF/0).<br />

The conveyor can only be restarted if the mechanical latch has<br />

been released by means of the reset button.<br />

Technical Data<br />

In compliance with the following standards<br />

and regulations<br />

EN 60947-5-1, EN ISO 13850<br />

VDE 0110 – degree of pollution: 2 (interior), 4 (exterior), BGI 710<br />

Suitable for Controls and equipment according to EN 60204<br />

Enclosure<br />

PBT<br />

Finish Enclosure: yellow (RAL 1004), reset button: blue (RAL 5010)<br />

Mounting<br />

4 holes for screws M6<br />

Permissible ambient temperature (VDE 0660) – 25 °C ^T amb<br />

^+ 70 °C<br />

<strong>Switch</strong>ing system<br />

1 changeover contact, 2 N.C.-contacts, all switching elements<br />

positive making and selfcleaning<br />

Rated insulation voltage U i<br />

250 V<br />

Conventional thermal current I th<br />

6 A<br />

Breaking capacity<br />

AC-15: AC 230 V / 1.5 A, DC-13: DC 60 V / 0.5 A, DC-13: DC 24 V / 2.0 A<br />

IP protection class IP 65/ IP 67 according to EN 60529<br />

Mounting position<br />

Any<br />

Cable entry Tapped hole for 3x M20 x 1.5<br />

1 x cable gland M20 x 1.5; sealing area n 6 - 12 mm<br />

2 x plug M20 x 1.5<br />

Connections max. 2.5 mm 2<br />

Actuating force approx. 190 N (pretensioning force approx. 110 N)<br />

Weight<br />

approx. 400 g<br />

Ordering code 91.057560.001


Contact Arrangements<br />

Connection diagram<br />

Terminals<br />

1<br />

.<br />

5<br />

Installation<br />

For assembling the <strong>PAS</strong> switch on the conveyor structure please refer to the following sketch.<br />

Swing hook<br />

Tension spring<br />

<strong>Rope</strong> loop<br />

Eyebolts<br />

Distance: max. 2.5mm<br />

<strong>Pull</strong> wire<br />

Length max. 30m<br />

Reset button<br />

max.<br />

122 mm<br />

<strong>Rope</strong> clamp<br />

<strong>Rope</strong> clamp Turnbuckle<br />

To adjust the correct tension of the rope a spacer is placed<br />

between enclosure and bellow.<br />

The pull rope is correctly adjusted if the spacer can easily<br />

be removed without any varying of the distance „x“.<br />

length of the <strong>Rope</strong><br />

The max. length of the rope depending on the ambient temperature is shown in the following diagram<br />

80<br />

70<br />

Maximum Ambient Temperature<br />

60<br />

50<br />

°C]<br />

[in<br />

Ambient Temperature<br />

40<br />

30<br />

20<br />

10<br />

0<br />

-10<br />

Ambient Temperature for Mounting (;15 °C )<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30<br />

-20<br />

-30<br />

Minimum Ambient Temperature<br />

Wire Length for a <strong>Pull</strong> Wire with a Diameter of 3 mm [in m]<br />

Wire length for a pull wire with a diameter of 3 mm [in m]


Dimensions<br />

101 ±0.2<br />

195.8 Hub = ±8mm<br />

101 ±0.2<br />

195.8 Hub = ±8mm<br />

Ø 6.6<br />

Ø 6.6<br />

48 ± 0.2 48 ± 0.2<br />

77.5<br />

77.5<br />

65<br />

65<br />

Subject to change without notice.<br />

Vossloh Kiepe GmbH<br />

D-40599 Düsseldorf (Germany) · Kiepe-Platz 1<br />

Phone +49 (0) 211 74 97-0 · Fax +49 (0) 211 74 97-420<br />

info@kiepe-elektrik.com · www.kiepe-elektrik.com<br />

511/2–02/09