10.07.2015 Views

Chainflex cables

Chainflex cables

Chainflex cables

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

asts.Starting at 1 mlength.No minimumorder.No cutting costs.With warranty.Will ship within24 hours.hainflex®...®®gus.eu/...chainflex.<strong>cables</strong>/...7.2010...plastics.for.longer.life...


24 hrs delivery time The goods leave igus ® within 24 hrs. Onrequest we can deliver via express orspecial delivery. Please inform us aboutyour wishes.No minimum orderigus ® has no minimum order. Just orderthe amount you need.From 1 mWith warrantyOrdering timesBecause <strong>Chainflex</strong> ® <strong>cables</strong> are of specialhigh quality only the necessary lengthshould be ordered. We appreciate eachorder from 1 m. Above orders of 1 myou may plan in 0.5 m steps.Beyond the legal warranty we alsovouch for wear and tear. Together withyou, we define your application‘s parameters.With a warranty certificate!From Monday to Friday8:00 am - 8:00 pmSaturday8:00 am - 12:00 pmHotline Phone +49-2203-9649-800Fax +49-2203-9649-222Online shopSee www.igus.eu. There you can findour whole product range. Order aroundthe clock.You have questions?For questions and more information callus or use our online product finders onwww.chainflex.eu


<strong>Chainflex</strong> ® cable's classification according to the criteria requirements, oil-resistance and travel distance.The <strong>Chainflex</strong> ® class is composed of 3 parts:Requirements Travel distance Resistance to oil1 up to 7 1 up to 4 1 up to 4To make the choice easier for you, we have classified all <strong>Chainflex</strong> ® -<strong>cables</strong> after thecriteria "requirements, oil-resistance and travel distance". The higher the number the betterthe cable.Requirements1: Flexible <strong>cables</strong>2: Highly flexible <strong>cables</strong>3: Chain-suitable <strong>cables</strong> without specialstructure (e.g. stranding in layers) forthe use in E-Chains ® .4: Cables with special structure for thepermanent move in E-Chains ® formedium requirements and radii from7,5 x d, speed up to 3 m/s5: Cables for the permanent move inE-Chains ® for high load requirementsand radii from 6,8 x d, speed up to10 m/s6: Cables for the permanent move inE-Chains ® for highest load requirementsand radii from 5 x d, speed upto 10 m/s7: Cables for the permanent move inE-Chains ® for highest load requirementsand smallest radii, indoor andoutdoor, radii from 4 x d, speed up to10 m/s and moreTravel distance1: freely suspended2: freely suspended and gliding up to 50 m3: freely suspended and gliding up to100 m4: freely suspended and gliding up to400 m and moreResistance to oil1: No resistance to oil2: Oil-resistant (following DIN EN60811-2-1, DIN EN 50363-4-1)3: Oil-resistant (following DIN EN60811-2-1, DIN EN 50363-10-2)4: Oil-resistant (following DIN EN 60811-2-1),bio-oil-resistant (following VDMA 24568with Plantocut 8 S-MB tested by DEA)Example: You are looking for a cable which resists highest mechanicalrequirements. Aside it should be oil-resistant following VDMA 24568.The travel distance should be up to 400 m and more for gliding applications.You choose from the classification overview (see left page):Requirements: 7Travel distance: 4Resistance to oil: 4This results in the cable's class – here "Class 7.4.4" that you cantake out of each product's page.In theory the following classes would be possible:lowest "Class 1.1.1", highest "Class 7.4.4"


<strong>Chainflex</strong> ®cableRequirementsTravel distanceResistance to oilCF210.UL 4 1 2CF270.UL.D 4 1 3CF111.D 4 1 4CF130.UL 4 2 1CF140.UL 4 2 1CF170.D 4 1 3CF180 4 1 3CFBUS.PVC 4 1 2CFBUS.PUR 4 1 3CF240 4 2 2CF77.UL.D 5 3 3CF78.UL 5 3 3CF5 5 3 2CF6 5 3 2CF211 5 3 2CF21.UL 5 3 2CF30 5 3 2CF31 5 3 2CFLK 5 1 3CF2 6 3 3CF112 6 3 3CF113/CF113.D 6 3 3CFLG.2H 6 3 3CF27.D 6 3 3CF14.CAT5 6 3 4CFCRANE 6 4 3CF9.UL 6 4 4CF10.UL 6 4 4CF11/CF11.D 6 4 4CF12 6 4 4CF11.LC./LC.D 6 4 4CFBUS 6 4 4CFKOAX 6 4 4CF34.UL.D 6 4 4CF35.UL 6 4 4CF300.UL.D 6 4 4CFPE 6 4 4CF310.UL 6 4 4CFLG.LB 7 3 4CF9 7 4 4CF10 7 4 4CF98 7 4 4CF99 7 4 4CFLG.G 7 4 4CF37.D 7 4 4CF38 7 4 4CF330.D 7 4 4CF340 7 4 4CFFLAT 7 4 4Your way through the <strong>Chainflex</strong> ® catalogue<strong>Chainflex</strong> ® lasts oryour money back!!igus ® tested!16Control Cables 50Data, Bus, Measuringsystem <strong>cables</strong>, Koax <strong>cables</strong>100Fibre optic cable (FOC) 154Servo Cables 166Power <strong>cables</strong>, Pneumatic hose 182Twistable <strong>cables</strong> 216<strong>Chainflex</strong> ® video-/vision-/bus technology232<strong>Chainflex</strong> ®network technology258<strong>Chainflex</strong> ® CF.INIsystems for initiators276<strong>Chainflex</strong> ®ReadyCable ® 291Connectors 404ChainfixStrain Relief Devices437ReadyChains ®Ready-madeEnergy Chain Systems ® 449Designing with igus ®Data and Schedules460


<strong>Chainflex</strong> ®<strong>Chainflex</strong> ®cableJacketShieldtypesMinimum bendingradius, moved[factor x d]Temperature,movedfrom/to [°C]Minimum bendingradius, fixed[factor x d]Temperature,fixedfrom/to [°C]Price indexControl <strong>cables</strong>CF130.UL PVC 7,5-10 -5/ +70 5 -20/ +70CF140.UL PVC ✔ 7,5-15 -5/ +70 5 -20/ +70CF5 PVC 6,8-7,5 -5/ +70 4 -20/ +70CF6 PVC ✔ 6,8-7,5 -5/ +70 4 -20/ +70CF77.UL.D PUR 6,8-7,5 -35/ +80 4 -40/ +80CF78.UL PUR ✔ 6,8-7,5 -35/ +80 4 -40/ +80CF170.D PUR 7,5-10 -35/ +80 5 -40/ +80CF180 PUR ✔ 7,5-15 -35/ +80 5 -40/ +80CF2 PUR ✔ 5 -20/ +80 4 -40/ +80CF9 TPE 5 -35/ +100 3 -40/ +100CF10 TPE ✔ 5 -35/ +100 3 -40/ +100CF9.UL TPE 5 -35/ +100 3 -40/ +100CF10.UL TPE ✔ 5 -35/ +100 3 -40/ +100CF98 TPE 4 -35/ +90 3 -40/ +90CF99 TPE ✔ 4 -35/ +90 3 -40/ +90These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible.Get online and use all the advantages of www.igus.euDownload the eplan-library for any type of <strong>cables</strong>www.igus.eu/eplan-download2


<strong>Chainflex</strong> ®Approvals andstandardsFlame-retardantOil-resistantHalogen-freeUV-resistantTorsion resistantv max.unsupported[m/s]typesv max.gliding[m/s]a max. [m/s 2 ]Number of coresCross sectionØ [mm 2 ]Page50✔ ✔ 3 2 20 2 - 30 0,25 - 6,0 52✔ 3 2 20 3 - 36 0,25 - 2,5 56✔ ✔ ✔ ✔ 10 5 80 2 - 42 0,25 - 2,5 60✔ ✔ ✔ 10 5 80 2 - 36 0,25 - 2,5 64✔ ✔ ✔ ✔ ✔ 10 5 80 2 - 36 0,25 - 4,0 68✔ ✔ ✔ ✔ 10 5 80 3 - 25 0,50 - 4,0 70✔ ✔ ✔ 3 2 20 3 - 30 0,50 - 10,0 72✔ ✔ ✔ 3 2 20 3 - 18 0,50 - 2,5 74✔ ✔ ✔ 10 5 80 3 - 48 0,14 - 1,5 76✔ ✔ ✔ ✔ 10 6 100 2 - 36 0,25 - 35,0 80✔ ✔ ✔ 10 6 100 2 - 25 0,14 - 4,0 84✔ ✔ ✔ ✔ 10 6 100 2 - 36 0,25 - 6,0 88✔ ✔ ✔ 10 6 100 2 - 25 0,25 - 4,0 92✔ ✔ ✔ ✔ 10 6 100 2 - 8 0,14 - 0,5 96✔ ✔ ✔ 10 6 100 2 - 8 0,14 - 0,34 98<strong>Chainflex</strong> ® types mentioned in the catalogue as “resistant to bio oil“ have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.Table of contents according to part number Page 492Table of contents according to industries Page 484Chain – cable – guarantee!Ask for fully harnessed and preassembled Ready-Chains ® – increase your cash-flow and profitimmediately. The igus ® system guarantee also coverscomponents delivered loose.www.readychain.eu3


<strong>Chainflex</strong> ®<strong>Chainflex</strong> ®CableJacketShieldtypesMinimum bendingradius. moved[factor x d]Temperature,movedfrom/to [°C]Minimum bendingradius, fixed[factor x d]Temperature,fixedfrom/to [°C]Price indexData <strong>cables</strong>CF240 PVC ✔ 10-12 -5/ +70 5 -20/ +70CF211 PVC ✔ 10 -5/ +70 5 -20/ +70CF112 PUR ✔ 10 -35/ +80 5 -40/ +80CF113 PUR ✔ 10 -35/ +80 5 -40/ +80CF11 TPE ✔ 10 -35/ +100 5 -40/ +100CF12 TPE ✔ 10 -35/ +100 5 -40/ +100Bus <strong>cables</strong> (with selection chart for <strong>Chainflex</strong> ® bus <strong>cables</strong>)CFBUS.PVC PVC ✔ 12,5 -5/ +70 7,5 -20/ +70CFBUS.PUR PUR ✔ 12,5 -35/ +70 7,5 -40/ +70CF BUS TPE ✔ 10-12,5 -35/ +70 5 -40/ +70CF11.LC TPE ✔ 10 -35/ +70 5 -40/ +70CF11.LC.D TPE ✔ 10 -35/ +70 5 -40/ +70CF14 CAT5 TPE ✔ 12,5 -35/ +70 7,5 -40/ +70Measuring system <strong>cables</strong>CF211 PVC ✔ 10 -5/ +70 5 -20/ +70CF113.D PUR ✔ 10 -20/ +80 5 -40/ +80CF111.D TPE ✔ 12 -35/ +100 6 -40/ +100CF11.D TPE ✔ 10 -35/ +100 5 -40/ +100Koax <strong>cables</strong>CF Koax1 TPE 10 -35/ +100 7,5 -40/ +100Fibre optic cable (FOC)CFLK PUR 12,5 -20/ +70 7,5 -25/ +70CFLG.2H PUR 12,5 -20/ +60 7,5 -25/ +60CFLG.LB TPE 5 -40/ +60 5 -40/ +60CFLG.G TPE 15 -40/ +60 8,5 -40/ +604These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible.


<strong>Chainflex</strong> ®Approvals andstandardsFlame-retardantOil-resistantHalogen-freeUV-resistantTorsion resistantv max.unsupported[m/s]typesv max.gliding[m/s]a max. [m/s 2 ]Number of coresCross sectionØ [mm 2 ]Page100✔ ✔ 3 2 20 3 - 24 0,14 - 0,34 102✔ ✔ 5 3 50 2 - 28 0,25 - 0,5 104✔ ✔ ✔ ✔ 10 5 80 4 - 12 0,25 - 0,5 106✔ ✔ ✔ ✔ 10 5 80 4 - 12 0,25 - 0,5 108✔ ✔ ✔ 10 6 100 4 - 36 0,14 - 2,5 110✔ ✔ ✔ 10 6 100 4 - 28 0,25 - 1,0 112114✔ ✔ ✔ 2 30 2 - 8 0,15 - 0,5 118✔ ✔ ✔ ✔ 2 30 2 - 8 0,15 - 0,5 120✔ ✔ ✔ 10 6 100 2 - 13 0,08 - 1,5 122✔ ✔ ✔ 10 6 100 2 - 9 0,25 - 1,0 126✔ ✔ ✔ 10 6 100 2 - 6 0,25 - 1,5 128✔ ✔ ✔ 10 6 100 4 - 10 0,25 130✔ ✔ 5 3 50 6 - 16 0,14 -1,0 132✔ ✔ ✔ ✔ 5 3 50 4 - 17 0,14 -1,0 136✔ ✔ ✔ 2 30 7 - 16 0,14 - 0,5 142✔ ✔ ✔ 10 6 100 4 - 17 0,14 - 1,0 146✔ ✔ 10 5 100 1 - 5 152154✔ ✔ ✔ 10 5 20 1 980/1000 µm 158✔ ✔ 10 6 20 2 50 + 62,5/125, 200/230 µm 160✔ ✔ 10 6 20 2 50 + 62,5/125 162✔ ✔ ✔ 10 6 20 6 - 12 50 + 62,5/125 µm 164<strong>Chainflex</strong> ® types mentioned in the catalogue as “resistant to bio oil“ have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.5


<strong>Chainflex</strong> ®<strong>Chainflex</strong> ®CableJacketShieldtypesMinimum bendingradius, moved[factor x d]Temperature,movedfrom/to [°C]Minimum bendingradius, fixed[factor x d]Temperature,fixedfrom/to [°C]Price indexServo <strong>cables</strong>CF210.UL PVC ✔ 10 -5/ +70 5 -20/ +70CF21.UL PVC ✔ 7,5 -5/ +70 4 -20/ +70CF270.UL.D PUR ✔ 10 -20/ +80 5 -40/ +80CF27.D PUR ✔ 7,5 -20/ +80 4 -40/ +80Power <strong>cables</strong>CF30 PVC 7,5 -5/ +70 4 -20/ +70CF31 PVC ✔ 7,5 -5/ +70 4 -20/ +70CF34.UL.D TPE 7,5 -35/ +90 4 -40/ +90CF35.UL TPE ✔ 7,5 -35/ +90 4 -40/ +90CF37.D TPE 7,5 -35/ +90 4 -40/ +90CF38 TPE ✔ 7,5 -35/ +90 4 -40/ +90CF300.UL.D TPE 7,5 -35/ +90 4 -40/ +90CFPE TPE 7,5 -35/ +90 4 -40/ +90CF310.UL TPE ✔ 7,5 -35/ +90 4 -40/ +90CF330.D TPE 7,5 -35/ +90 4 -40/ +90CF340 TPE ✔ 7,5 -35/ +90 4 -40/ +90CF FLAT TPE 5 -35/ +90 4 -40/ +90CF BRAID TPE 7,5 -35/ +70 4 -40/ +70CF BRAID.C TPE ✔ 7,5 -35/ +70 4 -40/ +70CF CRANE igupren ✔ 10 -20/ +80 7,5 -30/ +80These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible.<strong>Chainflex</strong> ® types mentioned in the catalogue as “resistant to bio oil“ have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.6


<strong>Chainflex</strong> ®Approvals andstandardsFlame-retardantOil-resistantHalogen-freeUV-resistantTorsion resistantv max.unsupported[m/s]typesv max.gliding[m/s]a max. [m/s 2 ]Number of coresCross sectionØ [mm 2 ]Page166✔ ✔ ✔ 10 50 4 - 8 1,5 - 6 / Pairs 0,75 - 1,5 168✔ ✔ ✔ 10 5 80 6 - 8 0,75 - 35 / Pairs 0,34 - 1,5 170✔ ✔ ✔ ✔ 10 50 4 - 8 1 - 35 / Pairs 0,5 - 1,5 174✔ ✔ ✔ ✔ 10 5 80 4 - 8 0,75 - 50 / Pairs 0,34 - 1,5 178✔ ✔ ✔ ✔ 10 5 80 4 - 5 1,5 - 50 184✔ ✔ ✔ 10 5 80 4 - 5 1,5 - 70 186✔ ✔ ✔ ✔ 10 6 80 3 - 5 1,5 - 50 188✔ ✔ ✔ 10 6 80 3 - 4 0,5 - 50 190✔ ✔ ✔ ✔ 10 6 80 3 - 5 1,5 - 50 192✔ ✔ ✔ 10 6 80 3 - 4 0,5 - 50 194✔ ✔ ✔ ✔ 10 6 100 1 6 - 185 196✔ ✔ ✔ ✔ 10 6 100 1 1,5 - 35 198✔ ✔ ✔ 10 6 100 1 4 - 185 200✔ ✔ ✔ ✔ 10 6 100 1 6 - 185 202✔ ✔ ✔ 10 6 100 1 4 - 185 204✔ ✔ ✔ 10 6 100 1 2,5 - 4 206✔ ✔ ✔ 10 6 80 8 2,5 208✔ ✔ ✔ 10 6 80 8 2,5 208✔ ✔ ✔ 10 6 50 1 25 - 95 210Table of contents according to part number Page 492Table of contents according to industries Page 4841827


<strong>Chainflex</strong> ®<strong>Chainflex</strong> ®CableJacketShieldtypesMinimum bendingradius, moved[factor x d]Temperature,movedfrom/to [°C]Minimum bendingradius, fixed[factor x d]Temperature,fixedfrom/to [°C]Price indexPneumatic hoseCFAIR PU 10 -25/ +80 8 -40/ +85CF Clean AIR PE 10 -25/ +60 8 -30/ +65Twistable <strong>cables</strong>CF ROBOT9 PUR ✔ 10 -25/ +80 4 -40/ +80CF ROBOT8 PUR ✔ 10 -20/ +70 7,5 -25/ +70CF ROBOT4 PUR ✔ 10 -25/ +80 4 -40/ +80CF ROBOT5 TPE 12,5 -20/ +60 7,5 -25/ +60CF ROBOT6 PUR 10 -25/ +80 4 -40/ +80CF ROBOT7 PUR ✔ 10 -25/ +80 4 -40/ +80CF ROBOT TPE ✔ 10 -35/ +100 4 -40/ +100These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible.<strong>Chainflex</strong> ® types mentioned in the catalogue as “resistant to bio oil“ have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.8


<strong>Chainflex</strong> ®Approvals andstandardsFlame-retardantOil-resistantHalogen-freeUV-resistantTorsion resistantv max.unsupported[m/s]typesv max.gliding[m/s]a max. [m/s 2 ]Number of coresCross sectionØ [mm 2 ]Page✔ ✔ 10 6 50 212✔ ✔ 10 6 50 214✔ ✔ ✔ ✔ 10 10 4 - 34 0,25 - 1 220✔ ✔ ✔ ✔ 10 10 2 - 8 0,14 - 0,35 222✔ ✔ ✔ ✔ 10 10 6 - 12 0,14 - 0,5 224✔ ✔ ✔ 10 10 2 50 + 62,5/125 µm 226✔ ✔ ✔ ✔ 10 10 3 10 - 35 228✔ ✔ ✔ ✔ 10 10 3 - 12 0,25 - 4 228✔ ✔ ✔ ✔ 10 10 1 10 - 50 230Table of contents according to part number Page 492Table of contents according to industries Page 4842169


<strong>Chainflex</strong> ® ReadyCable ®Cable type Jacket PageVideo-, vision engineering/bus technology (with camera reference list4page 254) 232FireWire Ready-made cable TPE 234USB Ready-made cable TPE 238GigE Ready-made cable TPE 242LWL Ready-made cable PUR 244LWL Ready-made cable (Robotics) TPE 248Koax Ready-made cable TPE 250Network-/ethernet-/fibre <strong>cables</strong> (FOC)/fieldbus 258CFLG.6G Gradient fibre glass cable, ready-made TPE 260CFLG.12G Gradient fibre glass cable, ready-made TPE 262CAT5 Ethernet cable, ready-made TPE 264CAT5 Ethernet cable, ready-made, L-/T-angle TPE 266CAT6 Ethernet cable, ready-made TPE 268Profibus Field bus cable, ready-made PVC/PUR/TPE 270Initiators CF9 – CF.INI (minimum bending radius 5 x d) 276Direct line/Connecting cable TPE 278Initiators CF10 – CF.INI (minimum bending radius 5 x d) 360° shieldedInitiators CF98 – CF.INI (minimum bending radius 4 x d)Direct line/Connecting cable TPE 284Direct line/Connecting cable TPE 28610


Selection table according to systems(Part No. and sheath materials) Jacket PageCables for Drive Technology 291B&R PVC/PUR/TPE 294Baumüller PVC/PUR/TPE 294Beckhoff PVC/PUR/TPE 296<strong>Chainflex</strong> ® ReadyCable ® 11Berger Lahr PVC/PUR/TPE 296Control Techniques PVC/PUR/TPE 297Danaher Motion PVC/PUR/TPE 298ELAU PVC/PUR/TPE 300Fagor TPE 301Fanuc PUR/TPE 301Heidenhain PUR/TPE 301Lenze PVC/PUR/TPE 302NUM PVC/PUR/TPE 303Rexroth PVC/PUR/TPE 303SEW PVC/PUR/TPE 305Siemens PVC/PUR/TPE 306Stöber PVC/PUR/TPE 307"Baumüller" is a registered trademark of "Baumüller Nürnberg GmbH, Nürnberg" / "Beckhoff" is a registered trademark of "Mr. Hans Beckhoff, Verl" / "BergerLahr" is a registered trademark of "Schneider Electric Motion Deutschland GmbH & Co.KG, Lahr" / "Danaher Motion" is a registered trademark of "DanaherMotion Technology LLC, Delaware" / "ELAU" is a registered trademark of "Elektronik-Automations-AG, Marktheidenfeld" / "Fanuc" is a registered trademarkof "Fanuc Ltd., Tokyo/Yamanashi" / "Heidenhain" is a registered trademark of "Dr. Johannes Heidenhain GmbH, Traunreut" / "Lenze" is a registered trademarkof "Lenze GmbH & Co. KG, Extertal" / "Rexroth" is a registered trademark of "Bosch Rexroth GmbH, Lohr" / "SEW" is a registered trademark of "SEW-EURO-DRIVE GmbH & Co KG, Bruchsal" / "Siemens" is a registered trademark of "Siemens AG, München" / "Stöber" is a registered trademark of "Stöber Antriebs -technik GmbH & Co. KG, Pforzheim"


<strong>Chainflex</strong> ® accessoryPageConnectors 404Test order – test igus ® ! 405SERIE A Signal connector 406SERIE B Power connector 410SERIE B Power connector 412SERIE M17 Signal- and power connector 413SERIE C Power connector 416SERIE D Power connector 418SERIE S Power connector 420Tools, accessories 422SUB-D SUB-D Signal connector 424Glands 428Strain Relief 437Chainfix steel clamps Adjustable with hexagon socket 440Chainfix Clips Snap-on strain relief device 442Chainfix Nugget Strain relief for <strong>cables</strong> 443Strain relief separator Separator with integrated teeth 444Tiewrap plates Bolted or clip-on 445Chainfix-tiewrap plates For C-profile, clip-on 446igus ® blocks Strain relief for hoses 447ReadyChain ® 449igus ® ReadyChain ® Ready-made Energy Chain Systems ® 45012


<strong>Chainflex</strong> ®PageTechnical Data and Schedules/user information/contact 460Designing with igus ®Cables and Hoses – General rules for <strong>cables</strong> and hoses in Energy Chains ® 462Cables and Hoses – Separation in Energy Chains ® 463Cables and Hoses – Further information on the separation of <strong>cables</strong> 464Electrical Round Cables 465Electrical Round Cables – Information on assembly and strain relief of electrical round <strong>cables</strong> 466Pneumatic hoses 467Data and SchedulesDIN 47100 colour code/Copper wire dimensions according to Anglo-American AWG numbers 468Calculation of the copper surcharge 469Load-Carrying Capacity of Cables 469Electrotechnical data 470Chemical resistance 476InformationsThe General Conditions 478User information, Disclaimer, KTG, Product illustrations 478Technical notes 478Approbation and Approvals 479Configure and order <strong>cables</strong> online, igus ® & eplan 480More igus ® products 482igus ® at www.igus.eu 483According to industries 484Table of contents according to part number 492Contact igus ®Fax – Customer-specific <strong>cables</strong> for Energy Chain Systems ® 488Fax – System Planning 489Fax – Harnessing 490Fax – Order 491igus ® worldwide 500Give us your oppinion – Catalogue improvementDefinition of the icons used in the catalogueCover (back)Cover (back)<strong>Chainflex</strong> ® <strong>cables</strong> classificationCover (ahead)13


How to use the catalog:<strong>Chainflex</strong> ® CablesShort descriptionProduct data and briefdescription of the selected<strong>Chainflex</strong> ® cable.Product illustrationDescription of the <strong>Chainflex</strong> ®cable design structure anddetailed product illustration.Technical dataDetailed description of the<strong>Chainflex</strong> ® cable, practicalillustration by means of icons.Including all information, e.g. ontemperature ranges, speeds,tensions, a description of thecable design.Cable categories<strong>Chainflex</strong> ® cable's classificationafter the criteria requirements,oil-resistance and travel distance.Approvals/standards14


Price indexThe price index allowscomparisons with similar<strong>Chainflex</strong> ® <strong>cables</strong> of theigus ® program.Product designationDesignation of the selected<strong>Chainflex</strong> ® cable.Chapter colourEvery cable type has its owncolour allowing faster catalogbrowsing.Application areaDescription of typicalcable applicatons.Delivery programTable with part no., numberof cores and conductornominal cross section,copper index and weight.Cable typeHere: Control cableOrder example andorder information.Strain-relief elementsi = Technical notesExampleQuicklink www.igus.eu/en/CF99Direct link to this product's online catalog:Free CAD-data, pdf files and more.15


Fleece<strong>Chainflex</strong> ® ...The tricks and ingenious features of...Extruded, non-tensionproofcentre elementCores strandedin LayersSingle-wire bundleswith short pitchlengthsPicture 1: Chainsuitable<strong>cables</strong>trandedin layersFrom the customer's point of view, a flexible energy supply system onlyneeds to function properly. However, this demand presupposes the perfectoperation of all components, including the <strong>cables</strong> being used in thissystem. And this is exactly where problems came up in the early 1980s.Due to constantly – and frequently even tremendously – increasing loadsresulting from the application of automation technology, guided <strong>cables</strong>often failed although the energy supply system itself was functioning perfectly.In extreme cases, failures caused by "corkscrews" and core rupturesbrought the entire production process to a standstill and resulted in highcosts.In order to find a solution to this unsatisfactory situation for its customers,igus ® decided to take the initiative. As the first company worldwide, igus ®began to develop complete Energy Chain Systems ® . <strong>Chainflex</strong> ® <strong>cables</strong>and Energy Chains ® are now being offered as a delivery from a singlesource and with a system guarantee depending on the application in eachcase. Based on the increasing know-how gained since 1989 and on thevery sophisticated series of tests that have been conducted since then,design principles were and are still being created that help prevent machinedowntimes in factories throughout the world today.How can "corkscrews" be prevented?Total shield withoptimized braiding angleCenterelement forhigh tensilestresses16Centerelement forhigh tensilestressesHighly abrasionresistant,gussetfilledextrudedjacketGusset-filledextrudedinner jacketPicture 2:Litz wire andcore structuresof a <strong>Chainflex</strong> ® cablePicture 3: igus ®stranding inbundles aroundcenter cordHere, the term "corkscrew" does not refer to a useful instrument for wineconnoisseurs. Instead, it refers to the permanent deformation of guided,moved <strong>cables</strong> caused by excessive stressing – which, in most cases,results in core rupture almost immediately afterwards. How does this happen?How can "corkscrews" be prevented? An important factor here – inaddition to a sensible design of the total Energy Chain System ® – is theconstruction of the guided <strong>cables</strong>. Basically speaking, a clear distinctioncan be made between <strong>cables</strong> stranded in bundles and <strong>cables</strong> strandedin layers (see picture 4).Properties of stranding in layersStranding in layers is significantly easier to produce and is therefore offeredon the market in so-called "chain-suitable" <strong>cables</strong> at low cost. But whatappears to be tempting at first glance can quickly turn into an expensivemistake when a "corkscrew" immobilizes the system being operated withthese <strong>cables</strong>. How do these problems arise? A look at the cable structurecan be quite helpful (see picture 1).In the case of stranding in layers, the cable cores are mostly strandedmore or less firmly and relatively long in several layers around a centerand are then provided with a jacket extruded to the form of a tube. In thecase of shielded <strong>cables</strong>, the cores are wrapped up with fleece or foils.But what, for example, happens to a similarly structured 12-core cableduring normal operation?The bending process compresses, in the movement of the core, the innerradius of the cable and stretches the core in the outer radius. Initially, thisworks quite well because the elasticity of the material is still sufficient.But very soon, material fatigue causes permanent deformations, and then,due to excursion from the specified paths, the cores make their"own compressing and stretching zones": The corkscrew is created, thenfollowed rather quickly by core ruptures most of the time.


lasts or your money back!...the <strong>Chainflex</strong> ® design and why we feel so confident about this designStranding in bundles tried and tested expensivelyand efficiently millions of times since 1989Stranding in bundles eliminates these problems by means of its verysophisticated, multiply stranded internal structure. Here, the litz wires arestranded with a special pitch length first and then the resulting cores arestranded into single core bundles. For large cross sections, this is donearound a strain relief element. The next step is the renewed stranding ofthis core bundle around a tension-proof center – a genuine center cord.(see picture 2)Due to this multiple stranding of the cores, all cores change the inner radiusand the outer radius of the bent cable several times at identical spacingdistances. Pulling and compressing forces balance one another around thehigh-tensile center cord that gives the stranded structure its necessary innerstability. Accordingly, the stranding remains stable even under maximumbending stress (see picture 3).Dictionary of defectsCore ruptureFailure of electric conductivity due to broken copperwires as a result of subjecting the individual cores tomechanical overload/ tensile load under constantbending stress. In most cases, the causes areincorrect litz wires and/or incorrect stranding pitchdirections and lengths.Insulation damageShort circuits due to damage to the insulation abovethe conductor. The cause can be material fatigue underconstant bending stress or material abrasion within thestranded structure. Single-wire breakage of theconductor or the shield braid result in perforation ofthe insulation.CorkscrewWhat are EMC problems and shield wirebreakage?In principle, cable shields must fulfil two tasks:● Protecting the <strong>cables</strong> from external interferences● Shielding any interferences before transmitting them to the outsideBoth tasks are equally important because faulty signals can causeconsiderable consequential damage in the system itself as well as in anyexternal systems. Furthermore, this is an especially problematic point dueto the fact that incorrect shielding usually cannot be detected from outside,and this is something that makes the trouble-shooting procedureextremely difficult. How can these kinds of problems arise in the firstplace?Once again, the answer is to be found in the internal structure of the cableitself: Is the shielding designed for the movements of the cable? Althoughit may be very easy to shield a fixed cable, it is much more difficult toguarantee the permanent shielding of a moving cable.In the case of so-called "chain-suitable" <strong>cables</strong>, for example, the strandingbond of an intermediate layer is wrapped up with foils or fleeces.This stranding bond is supposed to guarantee the separation betweenthe cores and the shield braid. But something that functions quite wellfor the fixed installation of <strong>cables</strong> is often quite insufficient in the case ofmoving <strong>cables</strong>. This has to do with the fact that the foils and fleeces donot create a bond between the stranding, shield and jacket and may fallapart under stress. Consequently, the metallic shield then rubs on theinsulation of the cores – short circuits are then to be expected.An externally detectable screw-like deformation of theentire cable due to broken copper wires as the resultof subjecting the individual cores to mechanicaloverload/ tensile load during the bending process. Inmost cases, the causes are unfavorable superstructureproperties (stranding in layers, missing center, loosejackets extruded to the form of a "tube") and subjectingthe <strong>cables</strong> to high bending stress.Jacket abrasionThe jacket is rubbed off down to the stranding or downto the total shield. In most cases, the causes areincorrect selection of materials and/or unfavorableextrusion processes resulting in detrimental surfaceproperties so that abrasion is an unavoidable effect.Jacket swelling/ jacket breakageJacket becomes soft and deformed or breaks until thestranding/shield can be seen. The cause can be theincorrect selection of materials with respect to the oilsor other chemical substances being used.Shielding losses/ EMC problemsElectromagnetic interferences inside or outside anelectric cable. In most cases, the cause is shield wirebreakage due to mechanical overload with incorrectshield braid angles. Other causes include loose braidsover foils without supporting effects or very open coverings.


<strong>Chainflex</strong> ® ...The tricks and ingenious features of...But the production of the shield itself is very time-consuming andcost-intensive and may have been the reason for the use of open braidshields or even simple wire wrappings. The disadvantages are quiteobvious: Open shields only possess a limited shielding effect in theirmoved state – motion and expansion reduce this effect even further. Thetype of shield is therefore an important point that is not even mentionedin some catalogues.In its up to approx. 70% linearly and approx. 90% optically covered <strong>cables</strong>,igus ® eliminates these weak points by means of an optimized internalstructure. In virtually all shielded <strong>Chainflex</strong> ® <strong>cables</strong>, a gusset-filled extrudedinner jacket over the stranded structure is therefore used. This "secondjacket" fulfils two tasks:● It holds the stranded structure together and guides the individualcores as in a channel.● It serves as a firm, round base for a very tight-fitting shield.Shield wire breakage – and how this can bepreventedAnd even during the production of the shield, there are many things thatcan be done correctly – or incorrectly. Here, an important parameter isthe braiding angle.In the case of "chain-suitable" <strong>cables</strong>, a tensile load of the shield wires inthe outer radius of the cable must usually be taken into account. If anunfavorable braiding angle is to be added, the tensile load increases evenfurther and shield wire breakage is the result. The consequences rangefrom reduced shielding effects right up to short circuits whenever thesharp wire ends penetrate through the fleeces or foils into the cores. Here,a useful tip: If, after the insulation has been stripped off, the shield canbe easily pushed back over the jacket, the shield is then usually unsuitablefor use in moved flexible energy supply systems! This is a problem thatigus ® has now solved with its direct approach:Jacket breakage at (36x0.14 2 )after only 900.000 to-and-frocycles with a bending factorof 7.8 x d● The shield braiding angle determined in long-termtests efficiently neutralizes the tensile forces and istherefore highly suitable for Energy Chains ® .● Due to the stable inner jacket, the shield cannot wanderuncontrolled.● The shield itself has a torsion protection effect on thestranded structure.Jacket abrasion/ jacket breakageWhereas defects in the internal structure are hardly detectable on the outside,jacket problems strike the eye immediately. The jacket is the firstprotection for the complicated internal structure. This is why broken, wornand swollen jackets are a serious quality defect. To prevent this problem,the igus ® customer can select among 7 acket materials to adapt his EnergyChain ® <strong>cables</strong> to suit the conditions of the respective environment.18


lasts or your money back!...the <strong>Chainflex</strong> ® design and why we feel so confident about this designGusset-filled extruded jacketHere, not only the material is an important factor but also the productionprocess. In the case of the so-called "chain-suitable" <strong>cables</strong>,the jackets are usually produced extruded to the form of a tubeand therefore do not provide the stranded structure with the necessarysupport for constant bending processes. The stranded structurecan fall apart.Therefore, igus ® is the first manufacturer of Energy Chain Systems ®to offer the so-called the "gusset-filled extruded" jacket.Here, the jacket material is injected between the core strandingpowdered with talc and ensures that the stranded structure doesnot open up and also makes sure that the cores are guided as ina channel. The special characteristic of this type of production isthat the intermediate spaces, which are created between the coresduring the stranding process, are completely filled with jacket materialby the high extrusion pressure. As a result, the jacket materialcreates a channel-like guide which allows the cores to carry out adefined longitudinal movement. The jacket also provides a supportingfunction for the stranding.The quality bundles of igus ® <strong>Chainflex</strong> ® <strong>cables</strong>● Strain-relieving center● Stranding in bundles● Gusset-filled extruded inner jacket in shielded <strong>cables</strong>● Enclosed shield braid● Optimized shield braiding angle● Gusset-filled extruded jacket7 basic rules for a good cable1. Strain-relieving centerClear space is created in the center of a cable accordingto the number of cores and the cross section of eachcable. This center should be filled, as far as possible, witha genuine center cord (and not, as frequently the case,with fillers or dummy cores consisting of waste materials).These measures will then efficiently protect the strandedstructure situated above and prevent the stranding fromwandering into the middle of the cable.2. Litz wire structureWith respect to the selection of litz wires, the maximumflexibility has proved to be the best solution. Although veryflexible conductors can be made using very thin individualwires, these conductors tend toward extreme formationof kinks. Long-term series of tests provided the result ofa shielded combination of single-wire diameter, pitch lengthand pitch direction as the best bending-resistant solution.3. Core insulationThe insulation materials must be made so that they do notstick to one another within the cable. Furthermore, theinsulation is also required to support the stranded individualwires of the conductor. Accordingly, only the highestquality,high-pressure-extruded PVC or TPE materials thathave proved their tested reliability in millions of core kilometersare then used in Energy Chain ® applications.4. StrandingThe stranded structure must be stranded around a stable,tension-proof center with an optimized short pitch length.However, due to the insulating materials being used, thisstranded structure should still be defined in mobile formwithin the stranding. Starting from a quantity of 12 cores,however, the method of stranding in bundles should beapplied.5. Inner jacketA gusset-filled extruded inner jacket must be used insteadof inexpensive fleeces, fillers or accessory fillers. This measureensures that the stranded structure is efficiently guidedin longitudinal direction. Moreover, the stranded structurecannot fall apart or wander off.6. ShieldingThe total shield should be made tight using an optimizedshield braiding angle over an extruded inner jacket. Looseopen braids or wrapped stranding reduce the EMC protectionconsiderably and can fail very quickly due to shieldwire breakage. A tight total braid shield also has a torsionprotection effect on the stranded structure.7. Outer jacketThe material-optimized outer jacket can fulfil many differentrequirements: From UV-resistant to low-temperature-flexible,and from oil-resistant to cost-optimized. Butthese outer jackets must have one thing in common: Ajacket material must be highly abrasion-resistant but notbe allowed to stick to anything. It must be flexible but alsoprovide a supporting function. In any case, the jacketshould also be extruded under pressure (gusset-filled).19


Sectional views throughDetailed structure of igus ® control, data, servo and motor<strong>Chainflex</strong> ® control cable,unshieldedIndividual bundles with optimized pitchlength and pitch directionCenter element forhigh tensile stressesSingle-wire diameteroptimized for Energy Chains ®Highly abrasion-resistant, gusset-filledextruded jacket<strong>Chainflex</strong> ®control cable, shieldedTotal shield with optimized braidingangle (covering approx. 70% linear,approx. 90% optical)Gusset-filled extruded innerjacket supports strandingCenter element for hightensile stressesTension-proof centerelement in individual bundlesPressure extruded jacket<strong>Chainflex</strong> ® data/sensor cable, shieldedStranded elements with optimizedpitch length and pitch directionGusset-filled extruded inner jacketsupports strandingCenter element for hightensile stressesPair braid shieldTotal shield with optimized braidingangle (covering approx. 70% linear,approx. 90% optical)20Pressure extruded jacket


the igus ® cable types<strong>cables</strong><strong>Chainflex</strong> ® FOCgradient fiber cableSupporting braid made ofglass-yarn-stranded GRP rodsGel-filled fiber sheathFOC fibersHighly abrasion-resistant TPE jacketIntegrated torsion protection<strong>Chainflex</strong> ®servo cable, shieldedTotal shield with optimized braidingangle (covering approx. 70% linear,approx. 90% optical)Optimized single-wire diameterCenter element for hightensile stressesGusset-filled extruded inner jacketStranding with optimizedpitch length and pitch directionPair braid shield overoptimized stranded core pairHighly abrasion-resistantpressure extruded jacket<strong>Chainflex</strong> ®power cable, shieldedTotal shield with optimized braidingangle (covering approx. 70% linear,approx. 90% optical)Gusset-filled extruded inner jacketCenter element for high tensilestressesOptimized single-wire diameterStranding with optimized pitchlength and pitch directionHighly abrasion-resistantpressure extruded jacket 21


<strong>Chainflex</strong> ® are thespecial <strong>cables</strong> for EnergyChain Systems ® –tested, tested, testedand tested.Partial view of igus ® experimental laboratory – testing, testing, testing of <strong>Chainflex</strong> ® <strong>cables</strong>22


Purpose of every <strong>Chainflex</strong> ®cableMore sensitive applications with high clock cycle numbers,velocities and accelerations as well as sophisticated environmentalconditions call for, especially in the field of energymanagement, tried-and-tested systems that are functionallyefficient for a long period of time. EMC safety and the fulfillmentof standards and directives such as UL, CSA, VDE,Interbus and Profibus are a necessary requirement today.After all, your automation system is supposed to functioncorrectly non-stop and worldwide even on a low-cost basis.That’s the igus ® mission.No contradiction:Good <strong>cables</strong>cost less.Quick availability throughout the world is a significant purchasecriterion. Advantages of our <strong>cables</strong>: successful tests,presence in more than 40 countries around the world anddeliverability ex warehouse. This saves time, money, storagecapacity and applies to each one of our 950 cable typeswhich you can order without any minimum quantity purchasesor surcharges. Which further advantages can be includedis something that depends on your specific conditions of use.number of double strokesnumber of double strokesTesting of a <strong>Chainflex</strong> ®CF5: 7 x 1 in "short"and "long" distancesof travel comparedwith other <strong>cables</strong>. CF5with 4,3 x d bendingradius"Short Travel""Long Travel"* Cables OK,test abandoned.Testing of a <strong>Chainflex</strong> ®CF5: 25 x 1 in "short"and "long" distancesof travel comparedwith other <strong>cables</strong>. CF5with 4,3 x d bendingradiusigus ® tested"Short Travel""Long Travel"* Cables OK,test abandoned.As a manufacturer of Energy Chains ® and special EnergyChain ® <strong>cables</strong>, igus ® uses the possibility of testing manydifferent types of chains and <strong>cables</strong> on a practice-orientedbasis. At the company-own technical training center inCologne, numerous series of tests are carried out on aparallel basis under the most difficult conditions. At thepresent time, there are more than 35 test setups withtheir test results being summarized in databases. Thisextensive, current data pool provides precise, reliableinformation on the actual service life and is also the basisof new product developments at the company. The testdata for Energy Chains ® and <strong>cables</strong>, but also for readymadesystems, are, however, described in such detailedform that igus ® confirms a functional guarantee for itsEnergy Chain Systems ® .23


Example 1: tested,tested, tested!Servo cable structureConductorcore insulation sheath made of TPEfleece● ●●●● ●●●●● ●●● ●●●●● ●● ●●● ●●●● ●●●●●●●● ●●●●●●●polyester foilaluminum-coated polyester foil●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●shieldcenterfillerInner jacket made of TPE-Eexternal jacket made of TPE-E24Sample B with fleece and fillerexperimental production4x10+(2x1,0) CThe purpose of the test is to determinethe advantages of the moreexpensive internal jacket in shieldedservo <strong>cables</strong> versus the less expensivefleece taping with fillers.In the case of flexible shielded<strong>cables</strong>, the shield is usually separatedfrom the composite core structure.On the one hand, this is done inorder to achieve a rounder braidform and, on the other hand, thefriction of the core insulation sheathagainst the braided shield structureis prevented due to the separationof the cores and shield. This can beachieved with an internal jacket ora fleece taping which is wrappedaround the composite core structure.The internal jacket is more sophisticatedand is therefore moreexpensive to produce. Following thetwisting process, the composite corestructure must run through theextruder in which the internal jacketis then put on. In contrast to thismethod, the fleece tape can be puton between the twisting point andthe reeling-up device during the twistingprocess and therefore doesnot require an own work operation.Product informationCF27.Dpage 178Sample A with internal jacketigus ® <strong>Chainflex</strong> ®CF27.100.10.02.01.D


Comparison between the igus ®solution with the gusset-filledinternal jacket and the fleece versionwith fillersHere, the servo <strong>cables</strong> are highly flexible motor connection<strong>cables</strong> with a complete copper shield and an integrated,shielded pair of control cores. This cable type was selecteddue to the fact that here the problematic case of an outof-roundbraid form due to the different core cross sectionsis a significant factor and that the various bending behaviorsof the production methods are therefore emphasized.n Sample A: CF27.100.10.02.01.D (igus ® GmbH)(4x10 mm 2 ) + (2x1,0 mm 2 )n Sample B: experimental(4x10 mm 2 ) + (2x1,0 mm 2 )Both <strong>cables</strong> are provided with identical nominal cross sectionsand insulation materials. Cable A is equipped with an internaljacket and cable B with a fleece taping and fillers.The experimental production (sample B) already shows theformation of a corkscrew after 145.000 double strokes. Inthe case of a cable, the so-called corkscrew refers to awave-shaped deformation like the one that can be seenin the following picture on sample B.Whereas, in the case of cable A, the internal jacket fills upthe gussets and a round braid structure is created as aresult, cable B requires fillers in the gussets. Like the core,the fillers also consist of filbrated polyethylene. They areeasy to compress and are therefore hardly capable of takingover any supporting effects. Whereas the internal jacket,which is made of TPE, and the cable A center, whichconsists of cordage, hold the cores in a defined position,the cores of cable B are able to move about uncontrolled.During the bending process, a core has detached itselffrom the composite braid structure and has been shiftedin the inner bending radius with respect to the center andon the outer bending radius with respect to the jacket. Thisresults in corkscrew-type deformations that repeat themselvesperiodically with the pitch length.5.000.0004.000.0003.000.0002.000.0001.000.000750.000500.000250.000100.00050.00005.000.000AssessmentDespite the extremely low bending factor of 4,76,no signs of wear can be detected in sample A(CF27.100.10.02.01.D) even after 5 million double strokes.Sample B, on the other hand, with its fillers and fleecetaping succumbs to a corkscrew formation already after145.000 double strokes. Accordingly, the result thereforejustifies the extra expenditure of the cable with thegusset-filled internal jacket.Number of double strokes145.000Sample BSample ASample A: CF27.100.10.02.01.DSample B: experimental production25


Example 2: tested,tested, tested! TechnicalData Properties CAT5Alteration of the electrical transmissionproperties of a CAT5 cablewhen subjected to an application ofstress with the minimum bendingradiusHigh transmission rates of up to 100 Mbit/s place high demandson the cable structure and its materials. The use of the <strong>cables</strong>in Energy Chains ® subjects these materials to additional stressand results in long-lasting alterations of the electrical properties.A CF 14.02.04.02.CAT5 cable was selected as a cable to be inspectedfor high transmission rates. Even when subjected to anapplication of stress with the minimum bending radius, the cablemust also be able to meet the electrical requirements of the IEC61156-6 standard. In the case of the CF14.02.04.02.CAT5 cable,four pairs of cores are stranded with one another, with each corepair possessing a nominal cross section of 0,25 mm 2 . The conductorconsists of bare copper wires and is surrounded by aninsulation sheath consisting of foamed PE.The following items were inspected:n Characteristic wave impedance of single pairsn Single-pair attenuationn Return loss of single pairsn Near-end crosstalk attenuation ofsingle pairs versus one anotherThe test is to be carried out in order to determine whether thelimit values of the IEC standard are complied with by the cableafter being subjected to bending stress.26


00 10 20 30 40 50 60 70 80 90 100MHz-5-10-15-20-25-30-35dB/100 mmax. norm valuenew conditionaccording to 332.269 double strokesaccording to 686.767 double strokesaccording to 1.561.281 double strokesAttenuationThe maximum values of the individual attenuation for each pair ofcores are specified for the corresponding nominal characteristicwave impedance in dB/100m in the DIN IEC 61156-6 standard.Accordingly, the <strong>cables</strong> are subdivided into several categories accordingto the transmission frequency planned to be used. For thecable being inspected, transmission frequencies of up to 100 MHzare planned to be used, which corresponds to the category 5e.Test resultThe attenuation, as a measure of the reduction of the transmittedelectrical energy of a signal on the cable, remains, even after morethan 1,5 million double strokes, below the specified limit value whilebeing subjected to the application of stress of the minimum bendingradius.The characteristic electrical transmission quantities such as characteristicwave impedance, return loss and near-end crosstalk arefulfilled so that, despite applications of high mechanical stress, theelectrical values of the IEC standard are complied with for a cableof the category 5.Product informationCF14 CAT5 page 13027


Example 3: tested,tested, tested! “Millionsof double strokes”in an energy chainProfibus <strong>cables</strong> in permanentlymovingindustrial useFor users, it is hard to get an overview of the cable market.Competition between cable suppliers is intensifying and manufacturersare outshining one another in their promises to“guarantee service life for <strong>cables</strong> used in energy chains”.Catalogues claim ten million - or even as many as 50 million- double strokes when it comes to the service life of <strong>cables</strong>used in applications involving movement.On taking a closer look at figures claimed, one must ask howtesting was done, or how realistic tests carried out actuallywere (for example length of travel, test radii, etc.) in order tobe able to provide such a guarantee.Even information stating that <strong>cables</strong> are tested in accordancewith VDE (Association of German electrical engineers) 0472,Part 603, test method H, is not helpful when it comes to determiningthe service life of a cable in energy chains, since theroller testing stand cannot provide any conclusive results andthere is no VDE test for special <strong>cables</strong> in energy chains.Differences in service lifeAt the beginning of 2002, a test to determine the service lifeof profibus <strong>cables</strong> in a real application was commissioned inigus’ test laboratory. The aim was to examine any differencesin the service life of igus’ CFBUS.001 <strong>Chainflex</strong> ® cableand another market leading profibus cable. The parametersrequired for the test were selected on the basis of data containedin the competitor’s catalogue:Catalogue detailsCross sectionGuaranteed lifetimeBending radiusDiameterCatalogue detailsTest item “A”Twin-coreprofibus cable(2 x AWG24)CMin. 4,0 Mio. Cycles> = 60 mm8,0 mmIssue 2002Test item “B”igus ® <strong>Chainflex</strong> ®CFBUS.001(2 x 0,25 mm 2 )CTo be determined ina test85 mm8,5 mmIssue 2002Test parameters according to catalogue data of the competitionA gliding application was chosen as a suitable test structuresince profibus cable systems are usually used here becauseof their data integrity, particularly over long lengths of traveland long transmission distances.In order to be able to carry out non-destructive testing andhence achieve a large number of bending cycles in a shortperiod of time, a genuine profibus transmission path waserected. In a PC at the fixed end of the test chain there wasa profibus master insert card. A connection to a profibus slavewas located on the moving end. This enabled the transmissionrate to be determined with the help of a diagnosis program.Any data packets which might have been transmittedincorrectly could be indicated. The highest-possible transmissionrate of 12 megabits/s was set.The fundamental test, which commenced at the beginningof 2002 and is still in progress today, showed that only arelatively low number of cycles (420.000) resulted in the totalfailure of test item “A“, which, according to the competitor’scatalogue, should have functioned safely for at least 4.0million cycles. Thus the real lifetime reaches only about 10%of the stated catalogue value.Picture: Sliding application as the basis of the test structureOn the other hand test item “B“, the CFBUS.001, is still undergoingtesting without any faulty data transmissions.So far, it has accomplished more than 14.0 million cycles.28


Structure and materialsThe main reason for the major differences in service life is thediffering structural parameters of test item “A“ and test item“B“ (CFBUS.001), as well as the different materials used forproducing the <strong>cables</strong>. The conductor insulation of the buscomprised of a foam material for all the test items. Theelectrical assets of this material ensured better transmissionproperties were achieved. A disadvantage of this material,however, was its weakness under reverse stresses. Theforces which affect the bus pair should be absorbed by theelement sheathing in order to alleviate the mechanical stressof the conductor insulation.Highly-elastic element sheathingFor this reason, test item “B“ (igus ® ) was provided with amechanically superior, extruded TPE inner, or element, gapfillingsheathing, in order to protect the bus pair against mechanicalinfluences during the bending procedure. The elementsheathing must be highly elastic. A mechanically inferior elementsheathing made of inexpensive filling material only servesto make the bus pair round, just like frequently used fillersor banding. It is not able to protect the buses from thehigh degree of mechanical stress present in the chain.Tensile and compression forces which occur mainly influencethose parts of the cable core in which there is a break inthe element sheathing.Test parametersDistance of travel:Speed, approx.:Acceleration, approx.:Radius, approx.:S = 5,0 mV = 3,5 m/sa = 7,5 m/s 255 mmNumber of double strokesTest item “A”CFBUS.001,Test item “B”which mechanically relieves the bus pair, fixes the cores in adefined position and bends. The extremely short pitch of thecore strands and special cable also ensure that no great tensileor compression force has an effect on a long length of core.UL and CSA approval<strong>Chainflex</strong> ® CFBUS <strong>cables</strong> are now also available for all standardfield bus systems, complete with UL and CSA approvaland DESINA compliance. The highly abrasion-resistant, flameretardantTPE outer jacket is extruded onto the fully braidedshield with an adjusted twisted angle in order to provide thecable with additional stability.The bus elements braided with a particularly short strand pitchare protected by means of a gap-filling, extruded TPE innerjacket. The bus parameters required are fulfilled by means ofa choice of coordinated insulating materials and productionprocedures.As with all <strong>Chainflex</strong> ® <strong>cables</strong>, the new standard field bus <strong>cables</strong>of the CFBUS series are now available ex stock, without anycutting costs or extra charges for small quantities.The sheathing of test item ”B“ (CFBUS.001) is on the onehand characterized by a mechanically superior, gusset-filledTPE element jacket, which mechanically relieves the bus pair,fixes the cores in a defined position and bends. The sheathingof test item ”B“ (CFBUS.001) is on the one hand characterizedby a mechanically superior, gusset-filled TPE element jacket,Product informationCFBUS page 122Position of the brokenelement jacketPosition of the brokencore insulationFig. 3: A mechanically low-quality element jacket can’t protect the bus pair against the high mechanical loads inside the Energy Chain ® .29


Example 4:tested, tested, tested!CF98 with < 4xd!For users of very small energy supply chains with mostlyvery narrow bending radiuses, the question for a suitablecable for very high stroke numbers has come up frequentlyin the past.At bending radiuses of less than 5xd, copper quickly reachesits physical limits, which necessitated the search forsuitable substitute conductor materials or for fundamentallydifferent conductor superstructures.Test set-up:Horizontal, short distance of travelTest parametersDistance of travel:Speed, approx.:Acceleration, approx.:Radius, approx.:S = 0,8 mV = 1,5 m/sa = 0,5 m/s 218 mmMany series of tests with a variety of conductor superstructuresand materials were performed in order to findout how <strong>cables</strong> must be manufactured in order to be ableto endure several millions of bending operations in E-Chains ® , even at bending radiuses of less than 4xd.Bending radius = 4 x dProduct informationCF98 page 9630


Test 1:Inspection of four differentcable designsFour different cable constuctions has been analyzed:Test item A – conductor with special conductor alloyTest item B – conductor same as test item A, but in copperTest item C – conductor in braided structureTest item D – conductor in stranded constructionThis long-term inspection, which was carried out over aperiod of 2 years, provided the following results:Test item ATest item BTest item CTest item DNumber ofdouble strokes47.434.277450.000638.0002.350.000Crosssection7x0,207x0,207x0,257x0,25d [mm]5,85,67,37,3Testradius3,1xd = 183,2xd = 182,5xd = 182,5xd = 18Test 2:Two different cable designs were tested, whereby different corenumbers and cross-sections were selected in comparison withtest 1:Test item A – conductor with special conductor alloyTest item B – conductor in copperIn this case, test item B was manufactured completely identicalto test item A except for the conductor material.The test showed that not a single case of wire breakage couldbe detected for test item A even after 28 million double strokes.Test item B, however, only achieved approx. 1,4 milliondouble strokes before complete destruction of the conductorwas determined. This test also demonstrates that the alloyconcept clearly surpasses the life of the copper conductor bymore than 19 times and achieves these extraordinary resultsin the mechanically critical area of very small cross-sections!Number ofdouble strokesTest item A 28.267.000Test item B 1.450.000Crosssection2x0,142x0,14d [mm]3,92,9Testradius4,6xd = 186,2xd = 18Number of double strokesNumber of double strokesTestradiusTest item A3,1xdTest item B3,2xdTest item C2,5xdTest item D2,5xdTestradiusTest item A4,6xdTest item B6,2xdConductivity of alloysHowever, the outstanding mechanical properties of thisalloy have to do with a reduced conductivity versus copper,which can be compensated by means of slightly increasedcross-sections. This means that the cross-sections mentionedin the catalog meet the electrically defined cross-sectionsdefined using the conductivity value. The conductor diameterof the alloyed conductor increases slightly compared to theconductor diameter of a copper conductor.This compromise results in a 10% greater external diameterfor the CF98 series versus a comparable CF9 type, althoughthe service life differences to be expected betweenthe CF98 versus the CF9 speak for themselves and increaseby a multiple factor in comparison with other so-calledchain-suitable <strong>cables</strong>.As in the case of the CF9 series, further characteristics ofthe <strong>Chainflex</strong> ® CF98 include the highly abrasion-resistant,gusset-filled extruded TPE outer jacket, the oil resistanceand the UV resistance as well as the absence of any PVCand halogen compounds. Especially in areas of applicationthat only possess minimum construction space but alsodemand a large number of strokes, the igus ® cable offersan increased degree of operational safety and efficiency.Areas of application are available in the semiconductor andcomponent parts industry, in the automation sector as wellas in the automotive and bank sector. New possibilities ofapplication can also be found in automatic doors for motorvehicles and trains as well as in automatic food and selfservicemachines and in the packaging industry.31


Example 5: tested!Dispersion and attenuationPlastic fiber-optic <strong>cables</strong> in Energy Chains ®Plastic fiber-optic <strong>cables</strong> have been introduced for datatransmission in industrial applications due to their excellentinterference-proof properties against electro-magnetic fieldsand further advantages such as the possibility of reducingdimensions and weights. The application as flexible linklines particularly in Energy supply chains places highdemands on plastic fiber-optic <strong>cables</strong>.The most important characteristic values of a fiber-opticcable are dispersion and attenuation. Dispersion is the termused to describe the scattering of the travel time of the signalin the fiber-optic cable. In plastic fiber-optic <strong>cables</strong> this isessentially caused by the mode dispersion, which arisesfrom the different travel times of individual light beams.Dispersion determines important transmission propertiessuch as bandwidth, cut-off frequency or maximum bit rate.Significant changes in dispersion could not be ascertainedin any of the investigations carried out.The industrial application of igus <strong>Chainflex</strong> ® -lines with plasticfiber-optic <strong>cables</strong> in supply chains for example is thereforeunproblematic with regard to changes in dispersion.The second important characteristic property, attenuation,determines the maximum possible length of a transmissionpath.The attenuation of a plastic fiber, like that of the glass fiber,is also strongly dependent on the wavelength of the lightused. For this reason all the investigations were carried outwith a wavelength of 666nm.Depending on the output of the transmitter and the sensitivityof the receiver the operator has a certain "attenuationbudget" available for the complete transmission pathincluding all junction and transition regions. This attenuationbudget (typical value approx. 20dB) must not be exceededif a secure transmission of the data is to be guaranteed.For this reason it is of great interest to the user to knowwhether and to what extent increases in attenuation are tobe expected for his particular application so that these canbe taken into account in the compilation of his own attenuationbudget.In addition to continuous bending stress, which is typicalfor operation in an Energy chain, further mechanical stressesthat can occur during installation or operation must be takeninto account. Thus, for example, relatively large tensile forcescan occur when integrating the line into an Energy chain.The fixing of the lines at the ends of the energy chain usingcable clamps leads to permanent transverse loads.The test of the behaviour under transverse load is carriedout following DIN VDE 0472, Part 223. Since the cableclamps only exercise pressure in an area covering a fewcentimetres, increases in attenuation are relatively low.Attenuation under tensile load depends to a great extentof course on the composition of the line. Lines with integratedcopper conductors or strain relief elements do notreveal a noticeable increase in attenuation until very muchgreater tensile forces are applied than is the case with purefiber-optic <strong>cables</strong>.32


Figure 1 represents test results for a <strong>Chainflex</strong> ® -line with 6fiber-optic <strong>cables</strong>. The length of the test sample is 1m andthe maximum tensile load 250 N.Course of the increase in attenuationas a function of the tensile forceFigure 2: Course of the increase in attenuation as a functionof the number of cycles.Increase in attenuation as a functionof the number n of travel movementsA in dBA in dBForce F in NThe tensile forces required to integrate fiber-optic <strong>cables</strong>in Energy Chains ® are usually much lower than 250 N. Theincrease in attenuation was 0,17 dB at maximum tensileforce and disappeared completely after the tensile load wasreleased. Thus no effect on attenuation should be expected.In the case of plastic fiber-optic <strong>cables</strong> that are bent veryoften, as is the case in applications with Energy Chains ® ,then further influencing factors such as material fatigue,dulling of the materials, micro-cracks right through to completefiber fracture must be feared, and their influence onattenuation can only be investigated in extensive practicaltests such as those carried out by igus ® .Number of cycle's n x 100.000The excellent test results, shown in part here, of the <strong>Chainflex</strong> ®-lines must not be taken for granted, as investigations offiber-optic <strong>cables</strong> from other manufacturers showed, someof which even failed with complete breaks in the fibers.The investigations revealed that <strong>Chainflex</strong> ® fiber-optic <strong>cables</strong>are not influenced in their function by mechanical loadssuch as tensile, transverse or bending stresses in EnergyChains ® . Therefore they are perfectly suitable for use in thesometimes rough industrial environments for the interference-prooftransfer of information between drive and controlelements of machines.Bibliography: [1] Plastic fiber-optic <strong>cables</strong> for flexible Energysupply systems: Bernfried Späth, Frank BlaseProduct information FOC page 24433


Example 6: tested!Selection from test resultsSince 1989, we have been working on the development of electrical <strong>cables</strong>.Back then, many of our customers lost their faith in the solutionwith energy supply systems because the <strong>cables</strong> being usedfrequently failed. Core breakage, "corkscrews", jacket wearand breakage of the shields were substantial reasons for thesefailures.Our <strong>Chainflex</strong> ® product range was then created from this situationof emergency. And due to the fact that we knew very little about<strong>cables</strong> at that time, we had only one choice:Testing, testing, testing, testing, testing.Accordingly, we have since been making use of a firm principle:We almost always test our <strong>cables</strong> with a bending radius thatis 30-50% less than the bending radius we mention in our catalog.We guarantee the quality requirement specified for our ownproducts based on the production-process-accompanyingsample tests that are carried out with at least 1 million reversebending processes. During the subsequent inspection of thecable, this cable must be completely intact and, especially,none of the single wires must be broken. Newly developedtypes undergo considerably longer reverse bending processesin Energy Chains ® before a new <strong>Chainflex</strong> ® series is released.Extensive databaseToday, we have recourse to an extensive database with detailedinformation on the service life of our <strong>Chainflex</strong> ® <strong>cables</strong> which makesit possible for us to give you the information you need for yourapplication.34Selection of test results from the igus ® -own technical trainingcenter in Cologne for the year 2000.


Example 7: tested!EMC testsThe "electromagnetic compatibility" of <strong>Chainflex</strong> ® <strong>cables</strong>The subject of "electromagnetic compatibility (EMC)" isbecoming increasingly important. For one thing, this is dueto a increase in the electromagnetic interference fields in thelong-distance range caused in particular by moderntelecommunications and communication technology as wellas in the local range caused by energy technology.On the other hand, the requirements for data transmissionare also increasing. The signals are becoming more susceptibleto interference and the electromagnetic environmentalinfluencing factors more diverse. This can be especiallyproblematic for the coupling between <strong>cables</strong> which, as isfrequently the case in energy-conducting chains, areconducted on a parallel basis over a certain distance. A heavycurrentcable with interference acts as a producer of anelectromagnetic interference field which, in turn, acts uponanother cable, normally a signal cable, and then causes cableconductedinterference there.Already several years ago, we therefore introduced electrical<strong>cables</strong> with fiber-optic <strong>cables</strong> made of glass that are alsocapable of being subjected to the mechanical stress in EnergyChains ® . Even the <strong>Chainflex</strong> ® <strong>cables</strong> with conventional copperconductors were tested with respect to their electromagneticcompatibility in an extensive, application-oriented test program.An asynchronous motor, for example, was therefore connectedvia an unshielded heavy-current cable (<strong>Chainflex</strong> ® CF30)to a frequency converter. This frequency converter with pulsewidth modulation becomes the generator of new spectralshares never existing previously in the primary or secondarynetworks. On a parallel basis with this heavy-current, <strong>Chainflex</strong> ®<strong>cables</strong> were also kept available for digital signal transmissionin Energy Chains ® . Especially good results can be achievedhere by the <strong>Chainflex</strong> ® CF12 cable which was specificallydesigned according to the EMC aspect. This cable possessestwisted-pair cores, the pairs of which are provided with acopper shield, as well as a total shield made of a steel braidin addition. Interference over a broad frequency range cantherefore be effectively prevented as a result.The capacitive as well as the inductive coupling was alsotested. In the case of the selected test conditions, it wasdetermined that, even when the energy <strong>cables</strong> and signalcable touch one another over a longer distance, error-freedata transmission is possible if a shielded <strong>Chainflex</strong> ® cable isused and this shield is grounded on both sides.In addition, tests were carried out in accordance with the existingstandards on electromagnetic compatibility. These standardsprovide a general basis for determining the operating behaviorof electrical devices that are repeatedly exposed to electricalinterference. They were not introduced specifically for <strong>cables</strong>.In particular, tests with the "burst generator" were carried out.Here, fast transient interference signals are generated in pulsegroups that simulate switching processes in particular. Suchprocesses occur, e.g. during the interruption of inductive loadsor during the bouncing of relay contacts. Here, too, the shielded<strong>Chainflex</strong> ® <strong>cables</strong> have proved their reliability.Product information CF12 page 11235


Example 8: tested, tested!Fibre optic <strong>cables</strong> –run 76.000 kmGo 76.000 km or 1,5 times round the worldwith <strong>Chainflex</strong> ® fibre optic <strong>cables</strong>.Users of data transmission systems (bus systems) with highdata rates or long transmission lengths or even heavy EMCloads are relying on fibre optic <strong>cables</strong> more and more often.Many users today, however, are not conscious of the factthat the advantages that apply for fibre optic <strong>cables</strong> in generalare even greater when <strong>Chainflex</strong> ® fibre optic <strong>cables</strong> are usedin E-Chains ® .Data transmission systems on a copper basis usually havetwo basic disadvantages.1. The maximum transmission lengths are greatly restrictedby the transmission systems (between 5 and 50 m cablelength depending on system and transmission frequency).2. The copper-based <strong>cables</strong> used in moving energy suppliesusually show an increase in attenuation values after sometime at high cycle rates, which in turn have a negativeeffect on the maximum ranges.The case is completely different with data transmission orbus system-independent fibre optic <strong>cables</strong> made of glass.As well as being suitable for any transmission/bus system(providing the right converters are used), they have the follo -wing advantageous properties:1. The transmission lengths are not restricted by the datatransmission systems used and are – depending on thetype of fibre optic cable used – several hundred metreslong.2. With <strong>Chainflex</strong> ® fibre optic <strong>cables</strong>, the increases in attenuationeven at very high cycle rates in E-Chains ® are so lowthat the values are almost non-measurable, and most ofthe attenuation is to be found near the plug.The question of how greatly the attenuation behaviour of anigus ® <strong>Chainflex</strong> ® fibre optic cable changes has been examinedusing the following test set-up, which had not been concludedas the catalogue went to press (in 4/08).Product informationCFLG.2H page 158


Test parameters:Test cable: igus ® <strong>Chainflex</strong> ® CFLG.2HG.MF.50/125Number of fibres: 2Type of fibre: Gradient fibre 50/125µmConnector: 2 x ST ConnectorTravel:2 mLength of cable: 3 mEnergy chain: igus ® E-Chain ® series 15.015.100.0Test radius: 11 x dTaking into consideration that ST plugs have a mean insertionattenuation of 0,3 dB and a maximum insertion attenuationof 0,5 dB, the increase in attenuation of approx. 0,1-0,15 dBafter more than 30 million movements in the E-Chain ® is absolutelynegligible.Thus the cable has covered more than 76.000 km during thetest.The lightwave length considered here is 850 nm.Increase in attenuation as a function of the number of individual strokesAttenuation in [dB]Number of individual strokes in [MioH]Maximum permissible attenuation37


Example 9: tested!Fast imagesFast images in industrial applications: USB, FireWireThe rising resolution and sampling rates of modern digitalvisual display systems are also inevitably accompanied by therapid increase in the data quantities to be transmitted.Fast bus systems which find application for similar data quantitiesvailable in the consumer sector were taken from theindustry particularly for this purpose.Here the typical representatives are bus systems such as Fire -Wire (1394a and 1394b), USB (2.0), as well as Gigabit Ethernetor CameraLink.All these bus systems need special <strong>cables</strong>, which are offeredin the consumer sector by numerous manufacturers atknocked-down prices.Many of these frequently preassembled <strong>cables</strong> are developedand manufactured only for static laying or minor mechanicalstressing.Costly production losses would be inescapable, if such <strong>cables</strong>were used in industrial applications with all the known parameterssuch as chemicals, electro-magnetic and mechanicalload, etc.These are not only "genuine" downtimes such as wire breakageor short circuits of the litz wires, but errors can be noticedgradually through alteration of the capacitive features with areduction of the possible transmission rates and increaseddampening.The use of substandard materials and a deficient mechanicalstructure in fiber optic <strong>cables</strong> can lead to murkiness of thefibers and thus also to reduced data rates.A genuine troubleshooting in bus <strong>cables</strong> is possible only withvery expensive equipment and lots of time.Depending on the position of the damage, the errors mayalso occur only sporadically during operation and cannot befound once the facility stops.The good experiences in thousands of applications with classicfield bus systems, e.g. Profibus, Interbus, DeviceNet, etc.,and the desire of many customers for comparable <strong>cables</strong> alsofor the above-mentioned high-speed bus systems led igus ®to develop an own cable series, among others, with the followingcable types:38Product informationpage 232n CFBUS.055 for FireWire 1394an CFBUS.065 and CFBUS.066 USB 2.0n CFLG.2HG.MF. Fiber optic cable series for busindependent,long transmission stretchesThe main focus in the development was on mechanically stablecable designs in order to grant the capacitive, inductive andoptical features over a high number of cycles.In the mechanical structure of the shields as well, a long servicelife was aimed at by material selection and special manufacturingprocesses.


In the industrial environment, it is not only the electrical andmechanical features that play a role, but also the resistanceto a great variety of media such as oils, coolants or the like.The seasoned outer jacket material TPE has already provedits durability in many thousands of applications in other igus ®<strong>cables</strong>.All <strong>cables</strong> are subject to ample tests in the igus ® laboratory;as there is no existing conclusive test procedure, the igus ®engineers chose a very pragmatic method.Stranded strain reliefelementsGel-filled,armoredfiber sheathGusset-filledextrudedPUR jacketCross section "<strong>Chainflex</strong> ® " fiber optic cable from igus ® .Several industrial cameras traversed on a fast linear motor ata speed of 2 m/s, an acceleration of 5 m/s and a travel of600 mm, while the bus <strong>cables</strong> moved continuously in theused E-Chain ® systems.Test rig:10 m CFBUS.055 FireWire (1394a) tested in an E-Chain ® ofthe B10.015.125 series with over 6 million movements witha FireWire 1394a camera.10 m CFBUS.066 (USB 2.0) tested in an E-Chain ® of theB10.015.100 series with over 3,5 million movements with aUSB 2.0 camera.10 m CFLG.2HG.MF.50/125 tested in an E-Chain ® of theB10.015.075 series with over 3 million movements with aFire-Wire 1394b camera with optical output.Despite the long cable lengths, particularly in USB and Fire -Wire, no adverse effects on the picture quality could be determinedeven according to this stroke rate.This non-scientific, but practice-oriented test distinctly provesthe industrial capability of these high-speed bus <strong>cables</strong>.This test is not complete and is continuing.39


Example 10: tested!Light in the coldLight in the cold – igus ® gradient fibre glass cable in the deep freeze testIn the safe transmission of large amounts of data in bussystems at high speeds over long distances, the igus ® gradientfibre glass cable of the type CFLG.G has already becomea standard in numerous applications in cranes.Insensitivity to electro-magnetic load and resistance to hardenvironmental influences enable the application together withenergy supply <strong>cables</strong> in very long travels.What happens in crane facilities in regions with extremely lowtemperatures? Does the maximum possible cable length ofseveral hundred metres reduce through increase in dampeningat low temperatures, or does the cable break in extremeapplications, for example at -40 °C?The sensitive glass fibres are conducted in a gel-filled hollowspace. How does the gel behave in highly dynamic conditionsand what happens in restarts after long downtimes?As no precise statement about this topic could be found inrelevant technical journals, and as little was known particularlyabout the thermal features of the gel, igus ® , as part of itsphilosophy, undertook own tests to determine the reliablespecifications for applications in E-Chain ® systems.For this task, the igus ® test laboratory was equipped with afreezer that can generate constant temperatures of -40 °Cand a test facility was mounted for long travels up to 7 m fora speed of 1,6 m/s and an acceleration up to 6 m/s.The igus ® gradient fibre glass cable CFLG.6G.50/125.TC wastested. The cable was tested with a length of about 15 m asloop in an igus ® E-ChainSystem ® 3500.125.200.0 with a radiusof 200 mm.40


Varied and extreme temperature curves thereby served forthe simulation of environmental influences, particularly whenthe temperature plunged during downtimes from plus degreesto -40 °C in the shortest time and the motion was restartedafterward.Under these application conditions, the dampening of thecable also should not rise above 3 dB at 850 nm wave length.After one million double strokes, which correspond to an operationalperformance of about 7000 kilometres, the maximumdampening is reached and still remains significantly below 3 dB.The measurements highlighted in the diagram reveal thatdistinct variations in temperature combined with the constantmovement in the E-Chain ® have only minor effects on thedampening of the CFLG.6G.TC cable.The noticeable high initial dampening is attributed to the plugsused and also reflects the reality here because, in practice,90 % of the <strong>cables</strong> used in automation are pluggable fibreoptic <strong>cables</strong>.Product informationCFLG.G page 164The test with the igus ® cable makes it quite clear that onlyrealistic and absolutely very expensive tests can fetch clarityabout the service life of <strong>cables</strong>.Dampening of the fibres 1-6 of the CFLG.6G.50/125.T cable in two directionsDampening in [dB] at 850 nmFibre no. 1, direction 1Fibre no. 2, direction 1Fibre no. 3, direction 1Fibre no. 4, direction 1Fibre no. 5, direction 1Fibre no. 6, direction 1Fibre no. 1, direction 2Fibre no. 2, direction 2Fibre no. 3, direction 2Fibre no. 4, direction 2Fibre no. 5, direction 2Fibre no. 6, direction 2Temperature in °C(number of double strokes)after 5 daysat restBEFORErestartafter 5 daysat restAFTERrestart41


Example 11: tested!Completely turned<strong>Chainflex</strong> ® <strong>cables</strong> for E-ChainSystem ® are designed for applicationin linear movements and their efficiency has been proveda million times.But industrial applications and their necessary motion sequencesbecome increasingly complex, so that special <strong>cables</strong> are moreand more required for torsional movements.The service life of the most differing constructions are yet harderto calculate for torsion applications, as no fixed sizes such asradii, travels or the like, are defined.Shielded <strong>cables</strong> however are very difficult in torsion applications.Braided shields are generally braided in the oppositedirection. Whether a cable maintains the torsional demandsis very strongly dependent on the application and type ofinstallation.In torsional movements the shield litz wires are therefore drawnin one winding direction, and the other turned in the otherwinding direction.The woven arrangement and the entailing constriction of eachwinding direction lead to a quick breakage of the shield fromthe resulting expansion of the shield litz wires.Unshielded <strong>cables</strong>, particularly all bundle-stranded <strong>Chainflex</strong> ®types, could be successfully used in many torsion applications.42At igus ® , the emphasis is not only on technology but also onbeautifully designed products. The TRC and TRE series bothreceived the iF-Design-Award.Product informationCF ROBOT page 216


The new igus ® development of a twistable, shielded singlecorecable picks up on this point and ensures, due to its specialdesign and understucture of the shield, that no forces atall or that only the smallest possible forces act on the shieldwire.As the described test clearly shows, massive service life extensioncan, for example, be determined when compared to aCF310.250.01.Test rig:The new cable CF ROBOT was tested at the igus ® laboratoryon a specially developed rig for torsion test.The torsion angle thereby amounts to ±270° for a total cablelength of about 2,5 m (tested in different versions of theTriflex ® R).Fitted for the test were:n 3 CF ROBOT <strong>cables</strong> 037n 3 <strong>cables</strong> of the series CF310.250.01.ULn 3 <strong>cables</strong> of the series CF310.250.01Picture 1: damaged overall shield sample of the braid versionafter 250.000 movements.The detail inspection of the shield braid shows distinct damageon the shield wires.The analyzed samples (Picture 2) of the CF ROBOT (so farsamples were taken after 250.000, 1,5 million and 3 millionmovements). 037 show no damage in the area of the cableor the overall shield even at above 3 million torsional movementsof ± 270°.Picture 2: The CF ROBOT shows absolutely no damage aftermore than 3 million movements.The detailed analyses (Picture 3) of the shield wires, bufferfibres, PTFE film and the cable show no apparent wear outs.The test is carried out further to determine the maximum servicelife of the cable.igus ® test lab: The <strong>cables</strong> were tested in movements of± 270°.The initial test sample of the CF310 with braided shield andthe CFROBOT were taken after 250.000 movements with atorsion angle of ± 270°.The analyses (cable taken apart) were undertaken in threepart areas respectively of the cable length.In the sample illustrated in Picture 1, distinct damage to theoverall shield are noticeable in the upper third of the cabletaken apart.Picture 3: detail pictures of the CFROBOT after more than3.0 million movements of ±270°.43


Example 12: tested,tested, tested!Service life comparisionRegular production inspections increase the operationalreliability of machines. In addition to tests performed inthe igus ® in-house laboratory, where new superstructuralparts, materials, and customer requirements are constantlybeing inspected, igus ® also performs production-accompanyinginspections.Next to batch tests, which immediately reveal any productionrelateddefects and provide the user with maximum reliability,long-term inspections are performed again and again.These long-term inspections, which can take up to four years– and emphasize the effort and expenditure required for suchseries of systematic tests – are necessary if the constantlygrowing market demands are to be met.This also applies to the long-term inspection of the<strong>Chainflex</strong> ® servo cable families CF21.UL and CF27.D. Theseservo <strong>cables</strong>, which are based on a modular system and onlydiffer in their inner and outer jacket materials in terms ofproduction details, were tested for more than 2,5 years at aradius of 100 mm, a travel distance of approx. 8 m, an accelerationof approx. 6 m/s 2 , and a velocity of approx. 3,5 m/s.A core number / cross-section combination which is widelyaccepted in the field of mechanical engineering but also resultsin failures due to the extremely asymmetric setup in the caseof many normal – so-called chain-suitable – cable superstructuralparts was deliberately selected.44


CF21.UL: overall stranding including the outer jacket withoutdamageCF27.D: overall stranding including the outer jacket withoutdamageCF21.40.10.02.01.UL: after more than 10 million bendingmovements, no shield wire breakagesCF27.40.10.02.01.D: after more than 10 million bending movements,no shield wire breakagesThe test items, CF21.40.10.02.01.UL (4x4 mm 2 + 2x1,0 mm 2 ),and CF27.40.10.02.01.D (4x4 mm 2 + 2x1,0 mm 2 ), which wereconstantly monitored electrically during the test phase, weretested in continuous operation in a real chain-equipped system.Result:After more than 10 million individual strokes, the <strong>cables</strong> weredisassembled into their individual parts and inspected. Ascan also be seen in the section photos, it was not possibleto determine any wire breakages on the individual conductorsor any changes on the insulations.Only slight traces of abrasion on the outer jacket – whichcannot result in any limitation of functions – also show thatthe cable has completed a large number of strokes.Summary:The design philosophy, with gusset-filled extruded inner jacketand pressure-extruded outer jacket, clearly shows the longservice life and definite advantages of these <strong>cables</strong> versusthe commonly used <strong>cables</strong> most of which are designed withfillers and tapes.Deliberately non-conforming chain filling in order to simulatea real application.Product informationCF21.UL page 170CF27.D page 17845


Example 13: tested live!Container crane at50 m travel distanceIn the crane engineering industry, energy supply systemsprove their technical and economic strengths more andmore frequently. Flexibility, variability, and space-savinginstallation are only a few of the most important criteria.An important building block of an energy supply systemhas to do with the <strong>cables</strong>. Here, users expect a highdegree of operational reliability.In the <strong>Chainflex</strong> ® laboratory, igus ® <strong>cables</strong> undergo constanttests which can be used to obtain important informationon the service life of a cable and to derive improvementsfor the future structural design of the cable.However, the situation becomes very exciting if you get therare opportunity to remove <strong>cables</strong> from their real, toughapplications and can inspect them.Current inspectionThe <strong>Chainflex</strong> ® cable CF9.60.05 has been used in containercranes for many years; in the case presented here with a totaltravel distance of approx. 47 m. An inspection contract commissionedby the owner-operator was to present a performancebalance sheet after more than 40.000 chain kilometres anddetermine the date from which the next preventive maintenancework for the other equipment should be taken into account.Following the removal of the CF9.60.05, inspections wereperformed with the following objectives:1. outer jacket, abrasion behaviour, other damage;2. overall stranding, insulation behaviour of the individual cores;3. litz wire structural design, number of any possibly individualbroken wires which might be an indication of an earlyfailure of the entire cable.An igus ® energy supply system with a length of approx. 26 m in a stainless steel trough with middle band support.46


The Energy Chain System ® was filled with many different igus ® <strong>Chainflex</strong> ® <strong>cables</strong>, e.g. the CF9.60.05Result regarding 1:No or only barely measurable traces of abrasion could bedetected on the highly abrasion-resistant TPE outer jacket.This means that a failure due to abrasion or jacket breakagedespite extreme environmental factors (temperature differences,UV irradiation, etc.) is not to be expected.Result regarding 2:The overall stranding structure showed – due to the gussetfilledextruded outer jacket – no indications of fatigue and hadnot changed in its pitch length.Due to the large share of talc, no abrasion was determinedbetween the TPE-insulated cores. The high-voltage tests alsodid not show any age-related changes.Result regarding 3:The cable was opened all the way to the copper conductorin the most stressed section of the radius.Here too, after more than 40.000 km, the inspection of theindividual wires also showed no fatigue breakages whichwould indicate an early failure of the cable.To sum up, it can be said that this cable, which was used ina real crane application in the second trolley of an STS crane,is still completely intact even after more than 40.000 km andthat preventive repair work is not required.An igus ® energy supply system with an approx. length of 26 min a stainless steel trough with middle band support.The individual elements of the CF9 from the cable piecedissected for the test setup.Product informationCF9 page 80A close-up of the completely intact copper conductor. Theinspection performed over the entire length shows that theconductor is still completely intact and does have anyindividual wire breakages.47


Example 14: tested!Comparison of sheathingmaterials in different oilsFor years now, specially developed tests tailored to the individualrequirements of igus ® customers have been used toobtain more meaningful results than would be conceivable ifstandard tests were used.The relatively generalised terms such as "oil-resistant" or"coolant-resistant" are little help in making the right selectionin terms of sheathing material to be used for an applicationwith oil, lubricant or coolant influence.Alongside the generally applicable tests according to e.g. DINEN 60811-2-1 and IEC 60811-1-1, "everyday applicationconditions" are simulated as realistically as possible in a testset-up specially matching our customers' requirements.Thus, for example, the test samples are mounted in an energychain that moves into an "oil bath" and then back out of itagain.This way, customers do not only get a statement referring tothe different resistance of the various materials.In contrast to the material ageing otherwise common followingthe above-mentioned standards, an estimation of service lifein the E-Chain ® application is also possible.If the test samples – such as the external <strong>cables</strong> depicted –do not achieve the prescribed test duration, we advise againstuse in the respective application.There is direct and alternating contact between the outersheath and the medium to be tested and the air surroundingthe energy chain or cable – just as in a real application.After a test duration to be freely chosen or defined accordingto igus ® standard, the test samples can be tested in terms ofchanges in material characteristics e.g. by comparing materialstrength, elongation at tear and swelling with the values notedbefore the test started.Cracks in the outer sheathing of materials from competitorscaused by the "use of oil" in E-Chains ® .48


Example 15: tested!Completely twisted,take two.The "torsion-resistant" requirement for <strong>cables</strong> for energy chainsis not new, but is seldom defined exactly. So how is a statementsuch as "This cable is torsion-resistant up to ±180 °!"to be evaluated? This makes it all the more important to beable to deliver comparable and meaningful test results.In order to satisfy this requirement, the "torsion test bench"was developed according to igus ® standard. Here, variouscable types are twisted to a prescribed cable length of1 metre, which also corresponds to the distance between thefixed points.The degree of torsion can be freely chosen, and is definedindividually according to the requirement made on the testspecimen, whereby the test standard is ±180 °.After a prescribed number of double strokes or a negativeelectrical or mechanical test result, the respective testspecimen is dissected, and the type and position of anydamage can be determined exactly.The first <strong>Chainflex</strong> ® CFROBOT types were developed to seriesmaturity on the basis of this igus ® standard test.Product informationCFROBOT page 216The "torsion test bench" especially developed according tothe igus ® standard.49


ontrol <strong>cables</strong>


<strong>Chainflex</strong> ®cableJacketShield<strong>Chainflex</strong> ®Minimum bendingradius, moved[factor x d]Temperaturmovedfrom/to [°C]typesApprovals andstandardsOil-resistantTorsion resistantv max. [m/s]unsupportedv max. [m/s]glidinga max. [m/s 2 ]PageControl <strong>cables</strong>CF130.UL PVC 7,5-10 -5/ +70 ✔ 3 2 20 52CF140.UL PVC ✔ 7,5-15 -5/ +70 3 2 20 56CF5 PVC 6,8-7,5 -5/ +70 ✔ ✔ 10 5 80 60CF6 PVC ✔ 6,8-7,5 -5/ +70 ✔ 10 5 80 64CF77.UL.D PUR 6,8-7,5 -35/ +80 ✔ ✔ 10 5 80 68CF78.UL PUR ✔ 6,8-7,5 -35/ +80 ✔ 10 5 80 70CF170.D PUR 7,5-10 -35/ +80 ✔ 3 2 20 72CF180 PUR ✔ 7,5-15 -35/ +80 ✔ 3 2 20 74CF2 PUR ✔ 5 -20/ +80 ✔ 10 5 80 76CF9 TPE 5 -35/ +100 ✔ ✔ 10 6 100 80CF10 TPE ✔ 5 -35/ +100 ✔ 10 6 100 84CF9.UL TPE 5 -35/ +100 ✔ ✔ 10 6 100 88CF10.UL TPE ✔ 5 -35/ +100 ✔ 10 6 100 92CF98 TPE 4 -35/ +90 ✔ ✔ 10 6 100 96CF99 TPE ✔ 4 -35/ +90 ✔ 10 6 100 9851


CF130.ULPVC7,5-10xdPVC Control cable<strong>Chainflex</strong> ® CF130.UL● for medium load requirements● PVC outer jacket● flame-retardantFine-wire strandedconductorCenter elementfor high tensilestresses[∞C][∞C]RRTemperature range -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2,moved+5 °C to +70 °C for use in Energy Chains ® with > 50.000 cyclesMinimum bending radius 7,5 x d with < 10 m travel, minimum bendingradius 10 x d with ≥ 10 m travelTemperature rangefixed-20 °C to +70 °C, minimum bending radius 5 x dv max.unsupported/gliding 3 m/s, 2 m/sa max. 20 m/s 2Travel distanceTorsionFreely suspended travel distances, but also for glidingapplications up to 50 m, Class 2± 90°, with 1 m cable lengthBraiding in bundlesaround high-tensilecenter cordNominal voltageNumber of cores < 12: 300/500 VNumber of cores < 12 (0,25-0,34): 300/300 VNumber of cores ≥ 12: 300/300 V(following DIN VDE 0245)Testing voltage 2000 V (following DIN VDE 0281-2).Gusset-filledextrudedFlame-retardantSilicon-freeConductorCore insulationAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Fine-wire stranded conductor consisting of bare copperwires (following EN 60228).Mechanically high-quality TPE mixture.Class 4.2.152Image exemplary.Core stranding Number of cores < 12: cores stranded in a layer with shortpitch length.Number of cores ≥ 12: cores combined in bundles and strandedtogether around a centre for high tensile stresses with adapted,short pitch lengths and pitch directions, especially low-torsionstructure.Core identification Cores < 0,5 mm 2 : colour code in accordance with DIN 47100Cores ≥ 0,5 mm 2 : cores black with white numerals, onecore green/yellow.Outer jacketLow-adhesion mixture on the basis of PVC, adapted to suitthe requirements in Energy Chains ® (following DIN VDE 0281Part 5). Colour: Silver gray (similar to RAL 7001)... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.2.1Price indexCF130.ULPVC7,5-10xdUL/CSA Style 10493 and 20200, 300 V, 60 °CCEI Following CEI 20-35CEFollowing 2006/95/ECLead freeFollowing 2002/95/EC (RoHS).Control cableTypical application arean for medium load requirementsn without influence of oiln preferably indoor applicationsn especially for freely suspended travel distances, but also for gliding applications up to 50 mn wood/stone processing, packaging industry, supply system, handling, adjusting equipmentTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ® CF130.UL for woodworking. E-Chain ® : E4/light950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF130(for up to 10 cuts of the same type)53


CF130.ULPVC7,5-10xdPVC Control cable<strong>Chainflex</strong> ® CF130.UL● for medium load requirements● PVC outer jacket● flame-retardantClass 4.2.1Image exemplary.Delivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF130.02.03.UL 3 x 0,25 4,5 8 24CF130.02.04.UL 4 x 0,25 5,5 10 37CF130.02.06.UL 6 x 0,25 6,0 15 47CF130.02.07.UL 7 x 0,25 6,5 18 45CF130.02.12.UL 12 x 0,25 8,5 31 94CF130.02.20.UL 20 x 0,25 10,5 49 143CF130.02.25.UL 25 x 0,25 11,5 63 151CF130.02.30.UL 30 x 0,25 12,5 72 185CF130.03.02.UL 2 x 0,34 4,5 7 33CF130.03.05.UL 5 x 0,34 5,5 17 48CF130.05.02.UL 2 x 0,5 5,5 10 40CF130.05.03.UL 3 G 0,5 6,0 14 55CF130.05.04.UL 4 G 0,5 6,5 19 60CF130.05.05.UL 5 G 0,5 7,0 24 65CF130.05.07.UL 7 G 0,5 8,0 34 100CF130.05.12.UL 12 G 0,5 9,5 55 116CF130.05.18.UL 18 G 0,5 12,0 90 158CF130.05.25.UL 25 G 0,5 13,5 126 222CF130.07.02.UL 2 x 0,75 6,0 15 50CF130.07.03.UL 3 G 0,75 6,5 22 60CF130.07.04.UL 4 G 0,75 7,0 29 80CF130.07.05.UL 5 G 0,75 7,5 36 90CF130.07.07.UL 7 G 0,75 8,5 50 130CF130.07.12.UL 12 G 0,75 10,5 81 149CF130.07.18.UL 18 G 0,75 13,0 121 214CF130.07.25.UL 25 G 0,75 15,5 167 303CF130.10.02.UL 2 x 1,0 6,0 19 50CF130.10.03.UL 3 G 1,0 7,0 29 75CF130.10.04.UL 4 G 1,0 7,5 39 90CF130.10.05.UL 5 G 1,0 8,0 48 110CF130.10.07.UL 7 G 1,0 9,5 68 170CF130.10.12.UL 12 G 1,0 11,5 108 185CF130.10.18.UL 18 G 1,0 14,0 161 263CF130.10.25.UL 25 G 1,0 17,0 224 371Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]NewNewNewNewNewNew54... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.2.1Price indexCF130.ULPVC7,5-10xdDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF130.15.02.UL 2 x 1,5 7,5 29 70CF130.15.03.UL 3 G 1,5 7,0 44 90CF130.15.04.UL 4 G 1,5 8,0 58 120CF130.15.05.UL 5 G 1,5 8,5 72 140CF130.15.07.UL 7 G 1,5 10,5 101 210CF130.15.12.UL 12 G 1,5 13,0 162 263CF130.15.18.UL 18 G 1,5 16,5 242 386CF130.15.25.UL 25 G 1,5 19,5 350 541CF130.25.03.UL 3 G 2,5 8,5 72 116CF130.25.04.UL 4 G 2,5 9,5 96 180CF130.25.07.UL 7 G 2,5 13,0 168 350CF130.25.12.UL 12 G 2,5 16,0 265 406CF130.40.03.UL 3 G 4,0 11,0 115 200CF130.60.04.UL 4 G 6,0 13,5 230 360CF130.60.05.UL 5 G 6,0 15,0 288 418Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Order example: CF130.05.02.UL – in your desired length (0,5 m steps)CF130.UL <strong>Chainflex</strong> ® series .05 Code nominal cross section .02 Number of coresPlease use www.chainflex.eu/en/CF130 for your online order.Control cableTel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF130(for up to 10 cuts of the same type)55


CF140.ULPVC7,5-15xdFine-wire strandedconductorPVC Control cable<strong>Chainflex</strong> ® CF140.UL● for medium load requirements● PVC outer jacket● shielded● flame-retardant[∞C][∞C]RRTemperature range -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2,moved+5 °C to +70 °C for use in Energy Chains ® with > 50.000 cyclesMinimum bending radius 7,5 x d with < 10 m travel, minimum bendingradius 15 x d with ≥ 10 m travelTemperature rangefixed-20 °C to +70 °C, minimum bending radius 7,5 x dv max.unsupported/gliding 3 m/s, 2 m/sa max. 20 m/s 2Braiding in bundlesaround high-tensilecenter cordGusset-filledextrudedTravel distance Freely suspended travel distances, but also for gliding applicationsup to 50 m, Class 2Nominal voltage Number of cores < 12: 300/500 VNumber of cores ≥ 12: 300/300 V(following DIN VDE 0245)Testing voltage 2000 V (following DIN VDE 0281-2).Bending-resistantbraided copper shieldPressure extrudedFlame-retardantSilicon-freeConductorCore insulationAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Fine-wire stranded conductor consisting of bare copperwires (following EN 60228).Mechanically high-quality TPE mixture.Class 4.2.156Image exemplary.Core stranding Number of cores < 12: cores stranded in a layer with shortpitch length.Number of cores ≥ 12: cores combined in bundles and strandedtogether around a centre for high tensile stresses with adapted,short pitch lengths and pitch directions, especially low-torsion structure.Core identification Cores < 0,5 mm 2 : colour code in accordance with DIN 47100Cores ≥ 0,5 mm 2 : cores black with white numerals, onecore green/yellow.Inner jacket PVC mixture adapted to suit the requirements in Energy Chains ® .Overall shieldBending-resistant, tinned braided copper shield.Coverage approx. 55% linear, approx. 80% optical.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.2.1Price indexCF140.ULPVC7,5-15xdOuter jacketLow-adhesion mixture on the basis of PVC, adapted to suit the requirements in EnergyChains ® (following DIN VDE 0281 Part 5).Colour: Silver gray (similar to RAL 7001)UL/CSA Style 10493 and 20200, 300 V, 60 °CCEI Following CEI 20-35Control cableCEFollowing 2006/95/ECLead freeFollowing 2002/95/EC (RoHS)Typical application arean for medium load requirementsn without influence of oiln preferably indoor applicationsn especially for freely suspended travel distances, but also for gliding applications up to 50 mn wood/stone processing, packaging industry, supply system, handling, adjusting equipmentTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF140(for up to 10 cuts of the same type)57


CF140.ULPVC7,5-15xdPVC Control cable<strong>Chainflex</strong> ® CF140.UL● for medium load requirements● PVC outer jacket● shielded● flame-retardantClass 4.2.1Image exemplary.Delivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF140.02.12.UL (12 x 0,25)C 10,0 69 111CF140.03.05.UL (5 x 0,34)C 8,0 42 80CF140.05.03.UL (3 G 0,5)C 8,0 37 87CF140.05.05.UL (5 G 0,5)C 9,0 52 130CF140.05.18.UL (18 G 0,5)C 13,5 130 232CF140.05.36.UL (36 G 0,5)C 20,0 273 493CF140.07.03.UL (3 G 0,75)C 8,5 48 90CF140.07.04.UL (4 G 0,75)C 9,0 57 130CF140.07.05.UL (5 G 0,75)C 9,0 66 150CF140.07.07.UL (7 G 0,75)C 10,5 84 170CF140.07.12.UL (12 G 0,75)C 13,0 130 220CF140.07.18.UL (18 G 0,75)C 15,0 179 289CF140.07.25.UL (25 G 0,75)C 17,5 256 414CF140.10.02.UL (2 x 1,0)C 7,5 33 84CF140.10.03.UL (3 G 1,0)C 8,5 44 130CF140.10.04.UL (4 G 1,0)C 9,5 55 150CF140.10.05.UL (5 G 1,0)C 10,0 77 170CF140.10.07.UL (7 G 1,0)C 11,5 107 200CF140.10.12.UL (12 G 1,0)C 13,5 162 243CF140.10.18.UL (18 G 1,0)C 16,5 227 407CF140.10.25.UL (25 G 1,0)C 18,5 322 481CF140.15.03.UL (3 G 1,5)C 9,5 69 150CF140.15.04.UL (4 G 1,5)C 10,0 89 180CF140.15.05.UL (5 G 1,5)C 11,0 105 220CF140.15.07.UL (7 G 1,5)C 12,5 135 260CF140.15.12.UL (12 G 1,5)C 15,0 215 407CF140.15.18.UL (18 G 1,5)C 18,5 339 467CF140.15.25.UL (25 G 1,5)C 22,0 480 703CF140.25.03.UL (3 G 2,5)C 10,5 98 171CF140.25.04.UL (4 G 2,5)C 12,0 174 250Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]NewNew58... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.2.1Price indexCF140.ULPVC7,5-15xdOrder example: CF140.10.04.UL – in your desired length (0,5 m steps)CF140.UL <strong>Chainflex</strong> ® series .10 Code nominal cross section .04 Number of coresPlease use www.chainflex.eu/en/CF140 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsControl cableTel. +49-2203-96 49-0Fax +49-2203-96 49-222CF140.UL for automatic feeder units. E-Chain ® : Easy Chain ®950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF140(for up to 10 cuts of the same type)59


CF5PVC6,8-7,5xdPVC Control cable<strong>Chainflex</strong> ® CF5● for high load requirements● PVC outer jacket● oil-resistant● flame-retardantNew!600V ULEspecially bendingresistantfine-wirestranded conductorCenter element forhigh tensile stresses[∞C][∞C]RRTemperature range -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2,moved+5 °C to +70 °C for use in Energy Chains ® with > 50.000 cyclesMinimum bending radius 6,8 x d with < 10 m travel, minimum bendingradius 7,5 x d with ≥ 10 m travelTemperature rangefixed-20 °C to +70 °C, minimum bending radius 4 x dv max.unsupported/gliding 10 m/s, 5 m/sa max. 80 m/s 2Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3Torsion± 90°, with 1 m cable lengthUVUV-resistantMediumBraiding in bundlesaround high-tensilecenter cordNominal voltage 300/500 V (following DIN VDE 0245).Testing voltage 2000 V (following DIN VDE 0281-2).Oil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1),Class 2Gusset-filledextruded, oil-proofPVC mixtureClass 5.3.260Image exemplary.Flame-retardantAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).ConductorFine-wire stranded conductor consisting of bare copperwires (following EN 60228).Core insulation Cores < 0,5 mm 2 : Mechanically high-quality PP mixture.Cores ≥ 0,5 mm 2 : Mechanically high-quality PVC mixture(following DIN VDE 0207 Part 4).Core stranding Number of cores < 12: cores stranded in a layer with shortpitch length.Number of cores ≥ 12: cores combined in bundles and strandedtogether around a centre for high tensile stresses with adapted,short pitch lengths and pitch directions, especially low-torsion structure.Core identification Cores < 0,5 mm 2 : colour code in accordance with DIN 47100Cores ≥ 0,5 mm 2 : cores black with white numerals, one... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.2Price indexCF5PVC6,8-7,5xdcore green/yellow.Outer jacketLow-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirementsin Energy Chains ® (following DIN VDE 0282 Part 10).Colour: Moss green (similar to RAL 6005)UL/CSA < 0,5 mm 2 : Style 10492 and 2570, 600 V, 80 °C≥ 0,5 mm 2 : Style 11113 and 2570, 600 V, 80 °CCEI Following CEI 20-35Control cableCEFollowing 2006/95/ECLead freeFollowing 2002/95/EC (RoHS)Clean room According to ISO Class 2, material/cable tested by IPA according to ISO standard 14644-1Typical application arean for high load requirementsn light oil influencen preferably indoor applications, but also outdoor ones at temperatures > 5 °Cn especially for freely suspended and gliding travel distances up to 100 mn storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranesTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF5(for up to 10 cuts of the same type)61


CF5PVC6,8-7,5xdPVC Control cable<strong>Chainflex</strong> ® CF5● for high load requirements● PVC outer jacket● oil-resistant● flame-retardantClass 5.3.2Image exemplary.Delivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF5.02.36 36 x 0,25 15,0 95 275CF5.03.15 15 x 0,34 10,5 52 135CF5.03.18 18 x 0,34 11,5 64 175CF5.03.25 25 x 0,34 13,5 88 235CF5.05.02 2 x 0,5 6,0 10 34CF5.05.03 3 G 0,5 6,0 15 42CF5.05.05 5 G 0,5 7,0 24 72CF5.05.07 7 G 0,5 8,0 34 77CF5.05.12 12 G 0,5 11,0 58 158CF5.05.18 18 G 0,5 12,5 86 230CF5.05.25 25 G 0,5 16,5 121 310CF5.05.30 30 G 0,5 17,5 144 402CF5.07.03 3 G 0,75 6,5 22 63CF5.07.04 4 G 0,75 7,0 29 72CF5.07.05 5 G 0,75 7,5 36 85CF5.07.07 7 G 0,75 9,0 50 108CF5.07.12 12 G 0,75 12,5 86 240CF5.07.18 18 G 0,75 15,0 130 322CF5.07.25 25 G 0,75 17,5 181 432CF5.07.36 36 G 0,75 22,0 259 564CF5.07.42 42 G 0,75 23,5 302 610CF5.10.03 3 G 1,0 6,5 29 62CF5.10.04 4 G 1,0 7,0 39 85CF5.10.05 5 G 1,0 9,0 48 100CF5.10.07 7 G 1,0 9,5 68 145CF5.10.12 12 G 1,0 13,5 116 260CF5.10.18 18 G 1,0 16,5 173 450CF5.10.25 25 G 1,0 19,5 241 590CF5.15.03 3 G 1,5 7,5 44 95CF5.15.04 4 G 1,5 7,5 58 120CF5.15.05 5 G 1,5 8,5 72 170CF5.15.07 7 G 1,5 10,5 101 220CF5.15.12 12 G 1,5 15,0 173 320CF5.15.18 18 G 1,5 19,0 260 550CF5.15.25 25 G 1,5 21,5 361 810CF5.15.36 36 G 1,5 26,0 518 980Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]62... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.2Price indexCF5PVC6,8-7,5xdDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF5.25.04 4 G 2,5 11,5 96 200CF5.25.05 5 G 2,5 12,0 120 250CF5.25.07 7 G 2,5 14,5 168 340CF5.25.12 12 G 2,5 23,5 288 667CF5.25.18 18 G 2,5 27,5 432 970CF5.25.25 25 G 2,5 34,5 600 1366Control cableNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF5.07.03 – in your desired length (0,5 m steps)CF5 <strong>Chainflex</strong> ® series .07 Code nominal cross section .03 Number of coresPlease use www.chainflex.eu/en/CF5 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTel. +49-2203-96 49-0Fax +49-2203-96 49-222CF5/CF6 for shelf control units: long travel in the longitudinal axis. E-Chain ® : Series E4/00 with igus ® guide trough out of steel950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF5(for up to 10 cuts of the same type)63


CF6PVC6,8-7,5xdEspecially bendingresistantfine-wirestranded conductorPVC Control cable<strong>Chainflex</strong> ® CF6● for high load requirements● PVC outer jacket● shielded● oil-resistant● flame-retardantNew!600V ULCenter elementfor high tensilestresses[∞C][∞C]RRTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-5 °C to +70 °C, minimum bending radius 6,8 x d with < 10 mtravel; minimum bending radius 7,5 x d with ≥ 10 m travel-20 °C to +70 °C, minimum bending radius 4 x d10 m/s, 5 m/sBraiding in bundlesaround high-tensilecenter corda max. 80 m/s 2Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3UVUV-resistantMediumNominal voltage 300/500 V (following DIN VDE 0245).Gusset-filledextrudedTesting voltage 2000 V (following DIN VDE 0281-2).Oil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1),Class 2Highly flexiblebraided coppershieldPressureextruded,oil-resistentPVC blendClass 5.3.2Flame-retardantAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).ConductorFine-wire stranded conductor consisting of bare copperwires (following EN 60228).Core insulation Cores < 0,5 mm 2 : Mechanically high-quality PP mixture.Cores ≥ 0,5 mm 2 : Mechanically high-quality PVC mixture(following DIN VDE 0207 Part 4).Core stranding Number of cores < 12: cores stranded in a layer with shortpitch length.Number of cores ≥ 12: cores combined in bundles and strandedtogether around a centre for high tensile stresses with adapted,short pitch lengths and pitch directions, especially low-torsion structure.Core identification Cores < 0,5 mm 2 : colour code in accordance with DIN 47100Cores ≥ 0,5 mm 2 : cores black with white numerals, onecore green/yellow.Inner jacket PVC mixture adapted to suit the requirements in Energy Chains ® .Overall shieldExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.64Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.2Price indexCF6PVC6,8-7,5xdOuter jacketLow-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirementsin Energy Chains ® (following DIN VDE 0282 Part 10).Colour: Moss green (similar to RAL 6005)UL/CSA < 0,5 mm 2 : Style 10492 and 2570, 600 V, 80 °C≥ 0,5 mm 2 : Style 11113 and 2570, 600 V, 80 °CCEI Following CEI 20-35Control cableCEFollowing 2006/95/ECLead freeFollowing 2002/95/EC (RoHS)Clean roomAccording to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPAaccording to standard 14644-1Typical application arean for high load requirementsn light oil influencen preferably indoor applications, but also outdoor ones at temperatures > 5 °Cn especially for freely suspended and gliding travel distances up to 100 mn storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranesTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF6(for up to 10 cuts of the same type)65


CF6PVC6,8-7,5xdPVC Control cable<strong>Chainflex</strong> ® CF6● for high load requirements● PVC outer jacket● shielded● oil-resistant● flame-retardantClass 5.3.2Image exemplary.Delivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]CF6.02.04 (4 x 0,25)C 7,5 31 72CF6.02.24 (3) (24 x 0,25)C 14,0 122 265CF6.03.05 (5 x 0,34)C 8,0 41 106CF6.05.02 (2 x 0,5)C 7,0 31 65CF6.05.05 (5 G 0,5)C 8,5 48 114CF6.05.07 (7 G 0,5)C 10,0 63 142CF6.05.09 (9 G 0,5)C 11,5 77 180CF6.05.12 (12 G 0,5)C 13,0 93 206CF6.05.18 (18 G 0,5)C 15,0 120 276CF6.05.24 (3) (24 G 0,5)C 17,5 190 405CF6.07.03 (3 G 0,75)C 8,0 52 110CF6.07.04 (4 G 0,75)C 8,5 54 120CF6.07.05 (5 G 0,75)C 9,0 73 150CF6.07.07 (7 G 0,75)C 10,5 93 190CF6.07.12 (12 G 0,75)C 14,0 138 264CF6.07.18 (18 G 0,75)C 17,5 204 410CF6.07.24 (3) (24 G 0,75)C 19,5 250 466CF6.10.03 (3 G 1,0)C 8,5 61 103CF6.10.04 (4 G 1,0)C 9,0 75 115CF6.10.05 (5 G 1,0)C 9,5 87 170CF6.10.07 (7 G 1,0)C 12,0 113 217CF6.10.12 (12 G 1,0)C 15,0 171 313CF6.10.18 (18 G 1,0)C 19,0 261 470CF6.10.24 (3) (24 G 1,0)C 21,0 307 588CF6.15.03 (3 G 1,5)C 9,0 81 155CF6.15.04 (4 G 1,5)C 10,0 85 170CF6.15.05 (5 G 1,5)C 10,0 106 190CF6.15.07 (7 G 1,5)C 12,0 153 270CF6.15.12 (12 G 1,5)C 17,0 232 411CF6.15.18 (18 G 1,5)C 21,5 367 637CF6.15.25 (25 G 1,5)C 23,5 492 819CF6.15.36 (36 G 1,5)C 30,0 630 1241CF6.25.04 (4 G 2,5)C 13,0 135 275The <strong>Chainflex</strong> ® types marked with a (3) refer to <strong>cables</strong> that are based on a bundling of 4 cores each. Due to their excellent electrical properties (star-quadwith especially minimum crosstalk), these <strong>cables</strong> can virtually be used in all cases in which otherwise twisted-pair <strong>cables</strong> are required.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core66... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.2Price indexCF6PVC6,8-7,5xdOrder example: CF6.15.12 – in your desired length (0,5 m steps)CF6 <strong>Chainflex</strong> ® series .15 Code nominal cross section .12 Number of coresPlease use www.chainflex.eu/en/CF6 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsControl cableTel. +49-2203-96 49-0Fax +49-2203-96 49-222CF5 and CF6 control cable (green) as well as CF211 measuring system cable (gray) in a screwing station of a motor factory.E-Chain ® : System E4/00 with Chainfix Clip Strain Relief Devices950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF6(for up to 10 cuts of the same type)67


CF77.UL.DPUR6,8-7,5xdPUR Control cable<strong>Chainflex</strong> ® CF77.UL.D● for high load requirements● PUR outer jacket● oil-resistant and coolant-resistant● flame-retardant● notch-resistant● PVC-free/halogen-freeFine-wire strandedconductor[∞C]RTemperature range -35 °C to +80 °C, minimum bending radius 6,8 x d withmoved< 10 m travel distance, minimum bending radius 7,5 x dTemperature rangefixed-40 °C to +80 °C, minimum bending radius 4 x dv max.10 m/s, 5 m/sunsupported/glidinga max. 80 m/s 2Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3Torsion± 90°, with 1 m cable lengthCenter element forhigh tensile stressesUV-resistantMediumNominal voltage Number of cores < 12: 300/500 VNumber of cores < 12 (0,25-0,34): 300/300 VNumber of cores ≥ 12: 300/300 V (following DIN VDE 0245)Testing voltage 2000 V (following DIN VDE 0281-2)Braiding in bundlesaround high-tensilecenter cordGusset-filledextrudedOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3Offshore MUD-resistant following NEK 606Flame-retardantAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992)Halogen-free Following EN 50267-2-1ConductorCore insulationFine-wire stranded conductor consisting of bare copperwires (following EN 60228)Mechanically high-quality TPE mixture.Class 5.3.3Core stranding Number of cores < 12: cores stranded in a layer with short pitch length.Number of cores ≥ 12: cores combined in bundles and strandedtogether around a centre for high tensile stresses with adapted, shortpitch lengths and pitch directions, especially low-torsion structure.Core identification Cores < 0,5 mm 2 : Colour code in accordance with DIN 47100.Cores ≥ 0,5 mm 2 :cores black with white numerals, one core green-yellow.Outer jacketLow-adhesion, highly abrasion-resistant mixture on the basisof PUR, adapted to suit the requirements in Energy Chains ®(following DIN VDE 0282 Part 10). Colour: Window gray (similarto RAL 7040)UL/CSA Style 10493 and 20233, 300 V, 80 °C68Image exemplary.CEI Following CEI 20-35... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.3CEFollowing 2006/95/ECPrice indexCF77.UL.DPUR6,8-7,5xdDESINAAccording to VDW, DESINA standardisationLead freeTypical application arean for high load requirementsn almost unlimited resistance to oilFollowing 2002/95/EC (RoHS)n indoor and outdoor applications with average sun radiationn especially for freely suspended and gliding travel distances up to 100 mn Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sectorControl cableDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF77.UL.02.04.D 4 x 0,25 5,5 10 34CF77.UL.05.04.D 4 G 0,5 6,0 19 48CF77.UL.05.05.D 5 G 0,5 6,5 24 55CF77.UL.05.12.D 12 G 0,5 10,0 57 128CF77.UL.05.18.D 18 G 0,5 12,0 86 188CF77.UL.05.25.D 25 G 0,5 14,0 119 244CF77.UL.05.30.D 30 G 0,5 15,0 143 297CF77.UL.07.03.D 3 G 0,75 6,5 21 52CF77.UL.07.04.D 4 G 0,75 7,0 28 61CF77.UL.07.05.D 5 G 0,75 7,5 35 71CF77.UL.07.07.D 7 G 0,75 8,5 49 100CF77.UL.07.12.D 12 G 0,75 12,0 84 183CF77.UL.07.18.D 18 G 0,75 13,5 126 247CF77.UL.07.20.D 20 G 0,75 14,5 140 277CF77.UL.07.36.D 36 G 0,75 18,5 252 500CF77.UL.10.02.D 2 x 1,0 6,5 20 52CF77.UL.10.03.D 3 G 1,0 6,5 29 61CF77.UL.10.04.D 4 G 1,0 7,0 39 75CF77.UL.10.05.D 5 G 1,0 8,0 49 91CF77.UL.10.07.D 7 G 1,0 9,0 68 112CF77.UL.10.12.D 12 G 1,0 12,5 116 222CF77.UL.10.18.D 18 G 1,0 15,0 174 321CF77.UL.10.25.D 25 G 1,0 17,0 240 406CF77.UL.15.03.D 3 G 1,5 7,5 42 81CF77.UL.15.04.D 4 G 1,5 8,0 55 99CF77.UL.15.05.D 5 G 1,5 8,5 69 117CF77.UL.15.07.D 7 G 1,5 10,5 96 164CF77.UL.15.12.D 12 G 1,5 14,0 165 290CF77.UL.15.18.D 18 G 1,5 17,0 260 397CF77.UL.15.25.D 25 G 1,5 19,5 360 555CF77.UL.25.04.D 4 G 2,5 9,5 91 145CF77.UL.25.05.D 5 G 2,5 10,5 120 179CF77.UL.25.07.D 7 G 2,5 12,5 168 253CF77.UL.40.04.D (1) 4 G 4,0 11,5 154 242(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF77(for up to 10 cuts of the same type)NewTel. +49-2203-96 49-0Fax +49-2203-96 49-22269


CF78.ULPUR6,8-7,5xdFine-wire strandedconductorPUR Control cable<strong>Chainflex</strong> ® CF78.UL● for high load requirements● PUR outer jacket● oil-resistant and coolant-resistant● flame-retardant● notch-resistant● PVC-free/halogen-free[∞C]RTemperature range -35 °C to +80 °C, minimum bending radius 6,8 x d withmoved< 10 m travel distance, minimum bending radius 7,5 x dwith ≥ 10 m travel distanceTemperature rangefixed-40 °C to +80 °C, minimum bending radius 4 x dv max.10 m/s, 5 m/sunsupported/glidinga max. 80 m/s 2Braiding in bundlesaround high-tensilecenter cordGusset-filledextrudedBiegefesterGeflecht-KupferschirmTravel distance Freely suspended and gliding travel distances up to 100 m,Class 3UV-resistantMediumNominal voltage Number of cores < 12: 300/500 VNumber of cores < 12 (0,25-0,34): 300/300 VNumber of cores ≥ 12: 300/300 V (following DIN VDE 0245)Testing voltage 2000 V (following DIN VDE 0281-2).Oil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3Offshore MUD-resistant following NEK 606Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1Mit DruckextrudiertConductorCore insulationFine-wire stranded conductor consisting of bare copperwires (following EN 60228).Mechanically high-quality TPE mixture.Class 5.3.370Image exemplary.Core stranding Number of cores < 12: cores stranded in a layer with short pitch length.Number of cores ≥ 12: cores combined in bundles and strandedtogether around a centre for high tensile stresses with adapted, shortpitch lengths and pitch directions, especially low-torsion structure.Core identification Cores < 0,5 mm 2 : Colour code in accordance with DIN 47100.Cores ≥ 0,5 mm 2 : cores black with white numerals, one coregreen-yellow.Inner jacket PUR mixture adapted to suit the requirements in Energy Chains ® .Overall shieldOuter jacketBending-resistant, tinned braided copper shield.Coverage approx. 55% linear, approx. 80% optical.Low-adhesion, highly abrasion-resistant mixture on the basis ofPUR, adapted to suit the requirements in Energy Chains ® (followingDIN VDE 0282 Part 10). Colour: Window gray (similar to RAL 7040)... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.3UL/CSA Style 10493 and 20233, 300 V, 80 °CPrice indexCF78.ULPUR6,8-7,5xdCEI Following CEI 20-35CELead freeFollowing 2006/95/ECFollowing 2002/95/EC (RoHS)Control cableTypical application arean for high load requirementsn almost unlimited resistance to oiln indoor and outdoor applications with average sun radiationn especially for freely suspended and gliding travel distances up to 100 mn Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sectorDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF78.UL.05.04 (4 G 0,5)C 8,0 32 77CF78.UL.05.05 (5 G 0,5)C 8,5 38 88CF78.UL.05.07 (7 G 0,5)C 9,5 56 117CF78.UL.05.09 (9 G 0,5)C 10,5 68 144CF78.UL.05.12 (12 G 0,5)C 12,5 88 198CF78.UL.05.18 (18 G 0,5)C 14,0 125 268CF78.UL.05.24 (24 G 0,5)C 15,5 160 334CF78.UL.07.03 (3 G 0,75)C 8,0 35 82CF78.UL.07.04 (4 G 0,75)C 8,5 47 94CF78.UL.07.05 (5 G 0,75)C 9,5 57 119CF78.UL.07.07 (1 (7 G 0,75)C 10,5 77 153CF78.UL.07.12 (12 G 0,75)C 13,5 125 252CF78.UL.07.18 (1) (18 G 0,75)C 15,5 175 337CF78.UL.10.03 (3 G 1,0)C 8,5 48 101CF78.UL.10.04 (4 G 1,0)C 9,0 58 116CF78.UL.10.05 (5 G 1,0)C 9,5 71 137CF78.UL.10.07 (7 G 1,0)C 11,0 94 179CF78.UL.10.12 (12 G 1,0)C 14,5 155 299CF78.UL.10.18 (1) (18 G 1,0)C 17,0 220 412CF78.UL.10.25 (25 G 1,0)C 19,5 315 535CF78.UL.15.03 (3 G 1,5)C 9,5 65 126CF78.UL.15.04 (4 G 1,5)C 10,0 80 145CF78.UL.15.05 (5 G 1,5)C 10,5 98 172CF78.UL.15.07 (7 G 1,5)C 12,5 131 225CF78.UL.15.12 (12 G 1,5)C 15,5 215 370CF78.UL.25.04 (4 G 2,5)C 11,5 123 205CF78.UL.25.05 (1) (5 G 2,5)C 12,5 150 245CF78.UL.25.07 (7 G 2,5)C 14,5 207 330CF78.UL.40.04 (1) (4 G 4,0)C 14,0 189 322NewNewTel. +49-2203-96 49-0Fax +49-2203-96 49-222(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF78(for up to 10 cuts of the same type)71


CF170.DPUR7,5-10xdPUR Control cable<strong>Chainflex</strong> ® CF170.D● for medium load requirements● PUR outer jacket● oil-resistant and coolant-resistant● PVC-free/halogen-free● low-temperature-flexibleFine-wire strandedconductorTemperature rangemoved-35 °C to +80 °C, minimum bending radius 7,5 x d with < 10 mtravel distance, minimum bending radius 10 x d with ≥ 10 mtravel distanceCenter elementfor high tensilestresses[∞C]RTemperature rangefixed-40 °C to +80 °C, minimum bending radius 5 x dv max.3 m/s, 2 m/sunsupported/glidinga max. 20 m/s 2Travel distance Freely suspended travel distances, Class 1UV-resistantMediumNominal voltage 300/500 V (following DIN VDE 0245)Testing voltage 2000 V (following DIN VDE 0281-2)Braiding in layers withextremely short pitchOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3.Offshore MUD-resistant following NEK 606Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Gusset-filledextrudedConductorCore insulationFine-wire stranded conductor consisting of bare copperwires (following EN 60228).Mechanically high-quality TPE mixture.Core strandingCores stranded in layers with short pitch length.Core identificationCores black with white numerals, one core green-yellow.Class 4.1.3Outer jacketCEDESINALead freeLow-adhesion mixture on the basis of PUR, adapted to suitthe requirements in Energy Chains ® (following DIN VDE 0282Part 10). Colour: Window gray (similar to RAL 7040)Following 2006/95/ECAccording to VDW, DESINA standardisationFollowing 2002/95/EC (RoHS)72Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.1.3Price indexCF170.DPUR7,5-10xdTypical application arean for medium load requirementsn almost unlimited resistance to oiln indoor and outdoor applications without direct sun radiationn especially for freely suspended travel distances, but also for gliding applications up to 20 mn Machining units/machine tools, low temperature applicationsControl cableDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF170.05.12.D 12 G 0,5 9,0 58 125CF170.05.18.D 18 G 0,5 11,5 86 180CF170.05.30.D 30 G 0,5 14,0 144 280CF170.07.03.D 3 G 0,75 6,5 22 50CF170.07.05.D 5 G 0,75 7,5 36 70CF170.07.07.D 7 G 0,75 8,5 50 100CF170.07.12.D 12 G 0,75 10,0 86 160CF170.07.18.D 18 G 0,75 12,5 130 230CF170.07.20.D 20 G 0,75 13,5 144 288CF170.10.03.D 3 G 1,0 7,0 29 55CF170.10.04.D 4 G 1,0 7,5 37 61CF170.10.05.D 5 G 1,0 8,0 48 85CF170.10.07.D 7 G 1,0 9,5 67 130CF170.10.12.D 12 G 1,0 10,5 118 170CF170.10.18.D 18 G 1,0 13,5 173 290CF170.10.25.D 25 G 1,0 16,0 240 390CF170.15.03.D 3 G 1,5 7,5 43 72CF170.15.04.D 4 G 1,5 8,0 58 90CF170.15.05.D 5 G 1,5 8,5 68 106CF170.15.07.D 7 G 1,5 10,5 101 180CF170.15.12.D 12 G 1,5 13,0 173 270CF170.15.18.D 18 G 1,5 15,0 259 390CF170.15.25.D 25 G 1,5 19,0 360 540CF170.25.04.D 4 G 2,5 10,0 96 150CF170.25.05.D 5 G 2,5 10,5 114 177CF170.25.07.D 7 G 2,5 13,0 168 280CF170.40.04.D 4 G 4,0 12,0 154 220CF170.60.04.D 4 G 6,0 14,0 230 320CF170.100.04.D 4 G 10,0 18,0 384 530Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Order example: CF170.10.05.D – in your desired length (0,5 m steps)CF170.D <strong>Chainflex</strong> ® series .10 Code nominal cross section .05 Number of coresPlease use www.chainflex.eu/en/CF170D for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF170D(for up to 10 cuts of the same type)73


CF180PUR7,5-15xdFine-wire strandedconductorPUR Control cable<strong>Chainflex</strong> ® CF180● for medium load requirements● PUR outer jacket● shielded● oil-resistant and coolant-resistant● PVC-free/halogen-free● low-temperature-flexibleTemperature rangemoved-35 °C to +80 °C, minimum bending radius 7,5 x d with < 10 mtravel distance, minimum bending radius 15 x d with ≥ 10 mtravel distanceCenter element forhigh tensile stresses[∞C]RTemperature rangefixedv max.unsupported/gliding-40 °C to +80 °C, minimum bending radius 5 x d10 m/s, 5 m/sa max. 20 m/s 2Travel distance Freely suspended travel distances, Class 1Braiding in layers withextremely short pitchUV-resistantMediumNominal voltage 300/500 V (following DIN VDE 0245).Gusset-filled extrudedBending-resistantbraided copper shieldTesting voltage 2000 V (following DIN VDE 0281-2).Oil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3.Offshore MUD-resistant following NEK 606Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Pressure extruded,halogen-free PURblendConductorCore insulationFine-wire stranded conductor consisting of bare copperwires (following EN 60228).Mechanically high-quality TPE mixture.Core strandingCores stranded in layers with short pitch length.Core identificationCores black with white numerals, one core green-yellow.Class 4.1.374Abbildung exemplarisch.Inner jacket PUR mixture adapted to suit the requirements in Energy Chains ® .Overall shieldOuter jacketCELead freeBending-resistant, tinned braided copper shield.Coverage approx. 55% linear, approx. 80% optical.Low-adhesion mixture on the basis of PUR, adapted to suitthe requirements in Energy Chains ® (following DIN VDE 0282Part 10). Colour: Window gray (similar to RAL 7040)Following 2006/95/ECFollowing 2002/95/EC (RoHS)... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.1.3Typical application arean for medium load requirementsn almost unlimited resistance to oiln indoor and outdoor applications without direct sun radiationn especially for freely suspended travel distances, but also for gliding applications up to 20 mn Machining units/machine tools, low temperature applicationsPrice indexCF180PUR7,5-15xdControl cableDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF180.05.18 (18 G 0,5)C 11,5 121 200CF180.07.03 (3 G 0,75)C 7,5 40 71CF180.07.05 (5 G 0,75)C 8,5 61 95CF180.07.12 (12 G 0,75)C 11,0 133 186CF180.07.18 (18 G 0,75)C 13,0 176 255CF180.10.05 (5 G 1,0)C 9,5 75 120CF180.10.18 (18 G 1,0)C 14,0 238 317CF180.15.03 (3 G 1,5)C 8,5 67 104CF180.15.04 (4 G 1,5)C 9,5 85 129CF180.15.07 (7 G 1,5)C 11,5 146 202CF180.25.04 (4 G 2,5)C 10,5 130 179CF180.25.05 (5 G 2,5)C 11,5 165 218CF180.25.07 (7 G 2,5)C 13,5 225 295Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF180.07.05 – in your desired length (0,5 m steps)CF180 <strong>Chainflex</strong> ® series .07 Code nominal cross section .05 Number of coresPlease use www.chainflex.eu/en/CF180 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF180(for up to 10 cuts of the same type)75


CF2PUR5 x dExtremely highflexible specialconductorPUR Control cable<strong>Chainflex</strong> ® CF2● for maximum load requirements● PUR outer jacket● shielded● oil-resistant and coolant-resistant● flame-retardant● notch-resistant● hydrolysis-resistant and microbe-resistantCenter element forhigh tensile stresses[∞C][∞C]RRTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-20 °C to +80 °C, minimum bending radius 5 x d-40 °C to +80 °C, minimum bending radius 4 x d10 m/s, 5 m/sa max. 80 m/s 2Braiding in bundlesaround high-tensilecenter cordTravel distance Freely suspended and gliding travel distances up to 100 m,Class 3UVUV-resistantHighGusset-filled,pressure extrudedNominal voltage 300/500 V (following DIN VDE 0245).Testing voltage 2000 V (following DIN VDE 0281-2).Highly flexiblebraided coppershieldOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3Offshore MUD-resistant following NEK 606PressureextrudedPUR blendClass 6.3.376Image exemplary.Flame-retardantAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).ConductorFine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Core insulation Cores < 0,5 mm 2 : Mechanically high-quality PP mixture.Cores ≥ 0,5 mm 2 : Mechanically high-quality PVC mixture(following DIN VDE 0207 Part 4).Core stranding Number of cores < 12: cores stranded in a layer with shortpitch length < 0,5 mm 2 : PP mixtureNumber of cores ≥ 12: cores combined in bundles and strandedtogether around a centre for high tensile stresses withadapted, short pitch lengths and pitch directions, especiallylow-torsion structure.Core identification Cores < 0,5 mm 2 : colour code in accordance with DIN 47100Cores ≥ 0,5 mm 2 : cores black with white numerals, onecore green/yellow.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.3.3Price indexCF2PUR5 x dInner jacket PVC mixture adapted to suit the requirements in Energy Chains ® .Overall shield Extremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Outer jacketLow-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suitthe requirements in Energy Chains ® (following DIN VDE 0282 Part 10).Colour: Anthracite gray (similar to RAL 7016)UL/CSA < 0,5 mm 2 : Style 10493 and 20317, 300 V, 80 °C≥ 0,5 mm 2 : Style 1007 and 20317, 300 V, 80 °CControl cableCEI Following CEI 20-35CEFollowing 2006/95/ECLead freeTypical application arean for maximum load requirementsFollowing 2002/95/EC (RoHS).n almost unlimited resistance to oiln indoor and outdoor applicationsn especially for freely suspended and gliding travel distances up to 100 mn storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes,refrigerating sectorTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF2(for up to 10 cuts of the same type)77


CF2PUR5 x dPUR Control cable<strong>Chainflex</strong> ® CF2● for maximum load requirements● PUR outer jacket● shielded● oil-resistant and coolant-resistant● flame-retardant● notch-resistant● hydrolysis-resistant and microbe-resistantClass 6.3.3Image exemplary.Delivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF2.01.04 (4 x 0,14)C 6,0 17 40CF2.01.08 (8 x 0,14)C 8,0 29 65CF2.01.12 (12 x 0,14)C 9,0 49 101CF2.01.18 (18 x 0,14)C 10,0 53 125CF2.01.24 (3) (24 x 0,14)C 11,5 65 135CF2.01.36 (36 x 0,14)C 14,0 88 200CF2.01.48 (48 x 0,14)C 17,0 135 310CF2.02.04 (4 x 0,25)C 7,0 24 53CF2.02.08 (8 x 0,25)C 8,0 41 83CF2.02.18 (18 x 0,25)C 13,0 96 190CF2.02.24 (3) (24 x 0,25)C 14,0 120 220CF2.02.48 (48 x 0,25)C 20,0 230 450CF2.05.05 (1) (5 G 0,5)C 10,5 64 170CF2.05.07 (1) (7 G 0,5)C 13,0 82 210CF2.05.09 (1) (9 G 0,5)C 15,0 97 260CF2.05.12 (1) (12 G 0,5)C 18,0 145 390CF2.05.18 (1) (18 G 0,5)C 22,0 192 520CF2.05.24 (3) / (1) (24 G 0,5)C 23,0 238 620CF2.07.03 (1) (3 G 0,75)C 10,0 51 140CF2.07.04 (1) (4 G 0,75)C 10,0 57 160CF2.07.07 (1) (7 G 0,75)C 14,0 102 240CF2.07.12 (1) (12 G 0,75)C 19,0 183 440CF2.07.24 (3) / (1) (24 G 0,75)C 25,0 302 720CF2.10.03 (1) (3 G 1,0)C 10,0 63 150CF2.10.05 (1) (5 G 1,0)C 12,0 91 200CF2.10.07 (1) (7 G 1,0)C 14,0 120 260CF2.10.12 (1) (12 G 1,0)C 20,0 213 480CF2.10.24 (1) (24 G 1,0)C 26,0 363 780CF2.15.03 (1) (3 G 1,5)C 11,0 85 190CF2.15.07 (1) (7 G 1,5)C 16,0 163 340CF2.15.12 (1) (12 G 1,5)C 23,0 289 650(1) Delivery time upon inquiryDeliverable alternative: CF10, CF10.UL, CF78.ULThe <strong>Chainflex</strong> ® types marked with a (3) refer to <strong>cables</strong> that are based on a bundling of 4 cores each. Due to their excellent electrical properties (star-quadwith especially minimum crosstalk), these <strong>cables</strong> can virtually be used in all cases in which otherwise twisted-pair <strong>cables</strong> are required.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core78... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.3.3Price indexCF2PUR5 x dOrder example: CF2.02.18 – in your desired length (0,5 m steps)CF2 <strong>Chainflex</strong> ® series .02 Code nominal cross section .18 Number of coresPlease use www.chainflex.eu/en/CF2 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsControl cableTel. +49-2203-96 49-0Fax +49-2203-96 49-222CF2 <strong>cables</strong> are resistant to oil and coolants. E-Chain ® : System E4/00950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF2(for up to 10 cuts of the same type)79


CF9TPE5 x dTPE Control cable<strong>Chainflex</strong> ® CF9● for maximum load requirements● TPE outer jacket● oil-resistant● bio-oil-resistant● PVC-free/halogen-free● low-temperature-flexible● hydrolysis-resistant and microbe-resistantExtremely highflexible specialconductor[∞C][∞C]RRTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +100 °C, minimum bending radius 5 x d-40 °C to +100 °C, minimum bending radius 3 x d10 m/s, 6 m/sCenter element forhigh tensile stressesa max. 100 m/s 2Travel distance Freely suspended and gliding travel distances up to 400 mand more, Class 4Torsion± 90°, with 1 m cable lengthUVUV-resistantHighBraiding in bundlesaround high-tensilecenter cordNominal voltage 300/500 V (following DIN VDE 0245).Testing voltage 2000 V (following DIN VDE 0281-2).Gusset-filledextruded, halogenfreeTPE mixtureOilSilicon-freeOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).HalHalogen-free Following EN 50267-2-1.ConductorFine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Class 7.4.4Core insulationCore strandingMechanically high-quality TPE mixture.Number of cores < 12: cores stranded in a layer with shortpitch length.Number of cores ≥ 12: cores combined in bundles and strandedtogether around a centre for high tensile stresses withadapted, short pitch lengths and pitch directions, especiallylow-torsion structure.80Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.4.4Price indexCF9TPE5 x dCore identification Cores < 0,75 mm 2 : colour code in accordance with DIN 47100Cores ≥ 0,75 mm 2 : cores black with white numerals, one core green/yellow.CF9.02.03.INI: brown, blue, blackCF9.03.04.INI: brown, blue, black, whiteCF9.03.05.INI: brown, blue, black, white, green-yellowCF9.03.16.07.03.INI:(0.75mm 2 ): blue, green-yellow, brown(0.34mm 2 ): violet, red, gray, red-blue, green, gray-pink, white-green,white-yellow, white-gray, black, yellow-brown, brown-green,white, yellow, pink, gray-brownOuter jacketLow-adhesion mixture on the basis of TPE, especially abrasion-resistant and highlyflexible, adapted to suit the requirements in Energy Chains ® .Colour: Steel blue (similar to RAL 5011)Control cableCELead freeFollowing 2006/95/ECFollowing 2002/95/EC (RoHS).Clean room According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1Typical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ® CF9 for outdoor crane systems. E-Chain ® : Series E4/00950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF9(for up to 10 cuts of the same type)81


CF9TPE5 x dTPE Control cable<strong>Chainflex</strong> ® CF9● for maximum load requirements● TPE outer jacket● oil-resistant● bio-oil-resistant● PVC-free/halogen-free● low-temperature-flexible● hydrolysis-resistant and microbe-resistantClass 7.4.482Image exemplary.Delivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF9.03.16.07.03.INI 4 x 4 x 0,34+3 x 0,75 11,0 74 159CF9.02.02 2 x 0,25 4,0 5 18CF9.02.03.INI 3 x 0,25 4,5 8 20CF9.02.06 6 x 0,25 5,5 15 35CF9.02.07 7 x 0,25 6,0 17 42CF9.02.08 8 x 0,25 6,5 20 46CF9.02.12 12 x 0,25 8,0 29 70CF9.02.18 (1) 18 x 0,25 9,5 44 98CF9.03.04.INI 4 x 0,34 5,0 13 31CF9.03.05.INI 5 x 0,34 5,5 17 37CF9.03.06 6 x 0,34 6,0 20 43CF9.03.08 8 x 0,34 6,5 26 55CF9.05.02 2 x 0,5 5,0 10 31CF9.05.03 3 x 0,5 5,5 15 32CF9.05.04 4 x 0,5 5,5 20 36CF9.05.05 5 x 0,5 6,0 24 46CF9.05.07 7 x 0,5 7,0 34 78CF9.05.12 12 x 0,5 9,5 58 105CF9.05.18 18 x 0,5 12,5 86 165CF9.05.25 25 x 0,5 13,5 120 201CF9.05.36 36 x 0,5 17,5 173 368CF9.07.05 5 G 0,75 6,5 36 58CF9.07.07 7 G 0,75 8,0 50 76CF9.07.12 12 G 0,75 11,0 86 142CF9.07.20 20 G 0,75 13,0 144 231CF9.07.25 25 G 0,75 14,5 180 320CF9.10.03 3 G 1,0 6,0 29 49CF9.10.04 4 G 1,0 6,5 38 56CF9.10.05 5 G 1,0 7,0 48 70CF9.10.12 12 G 1,0 11,5 115 181CF9.10.18 18 G 1,0 14,0 173 267CF9.10.25 25 G 1,0 17,0 241 329CF9.15.02 2 x 1,5 6,5 29 54CF9.15.04 4 G 1,5 7,5 58 86CF9.15.05 5 G 1,5 8,0 72 110CF9.15.07 7 G 1,5 9,5 101 140CF9.15.12 12 G 1,5 14,0 173 265(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.4.4Delivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Price indexCopperindex[kg/km]CF9.15.18 18 G 1,5 17,0 260 400CF9.15.25 25 G 1,5 20,0 360 602CF9.15.36 36 G 1,5 23,0 519 840CF9.25.04 4 G 2,5 9,0 96 128CF9.25.05 5 G 2,5 10,0 120 174CF9.25.07 7 G 2,5 12,0 168 301CF9.25.12 12 G 2,5 17,0 288 468CF9.25.16 16 G 2,5 21,0 384 600CF9.25.18 (7) 18 G 2,5 22,5 432 827CF9.25.25 25 G 2,5 24,5 600 990CF9.40.04 4 G 4,0 10,0 154 195CF9.60.04 4 G 6,0 12,5 230 310CF9.60.05 5 G 6,0 14,0 288 400CF9.100.04 (6) 4 G 10,0 15,5 384 515CF9.160.04 (6) 4 G 16,0 20,0 614 780CF9.350.04 (6) 4 G 35,0 26,0 1344 1700(6) Nominal voltage 600/1000 V (7) Nominal voltage 450/750 VNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Order example: CF9.25.04 – in your desired length (0,5 m steps)CF9 <strong>Chainflex</strong> ® series .25 Code nominal cross section .04 Number of coresPlease use www.chainflex.eu/en/CF9 for your online order.CF9TPE5 x dTel. +49-2203-96 49-0Control cableFax +49-2203-96 49-222Delivery time 24h or today** Delivery time means time until shipping of goodsCF9 for maximum load requirements for both indoor and outdoor applications. E-Chain ® : System E4/4950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF9(for up to 10 cuts of the same type)83


CF10TPE5 x dExtremely highflexible specialconductorTPE Control cable<strong>Chainflex</strong> ® CF10● for maximum load requirements● TPE outer jacket● shielded● oil- and bio-oil-resistant● PVC-free/halogen-free● low-temperature-flexible● hydrolysis-resistant and microbe-resistantCenter element forhigh tensile stresses[∞C][∞C]RRTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +100 °C, minimum bending radius 5 x d-40 °C to +100 °C, minimum bending radius 3 x d10 m/s, 5 m/sa max. 100 m/s 2Braiding in bundlesaround high-tensilecenter cordTravel distanceFreely suspended and gliding travel distances up to 400 mand more, Class 4UVUV-resistantHighGusset-filled,pressure extrudedNominal voltage 300/500 V (following DIN VDE 0245).Testing voltage 2000 V (following DIN VDE 0281-2).Highly flexiblebraided coppershieldOilSilicon-freeOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Pressureextruded,halogen-freeTPE blendHalHalogen-free Following EN 50267-2-1.ConductorFine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Core insulationMechanically high-quality TPE mixture.Class 7.4.484Image exemplary.Core stranding Number of cores < 12: cores stranded in a layer with shortpitch length.Number of cores ≥ 12: cores combined in bundles and strandedtogether around a centre for high tensile stresses withadapted, short pitch lengths and pitch directions, especiallylow-torsion structure.Core identification Cores < 0,75 mm 2 : colour code in accordance with DIN 47100Cores ≥ 0,75 mm 2 : cores black with white numerals, onecore green/yellow.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.4.4Price indexCF10TPE5 x dInner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Overall shieldOuter jacketExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highlyflexible, adapted to suit the requirements in Energy Chains ® .Colour: Steel blue (similar to RAL 5011)Control cableCEFollowing 2006/95/ECLead freeFollowing 2002/95/EC (RoHS).Clean roomAccording to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPAaccording to standard 14644-1Typical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF10(for up to 10 cuts of the same type)85


CF10TPE5 x dTPE Control cable<strong>Chainflex</strong> ® CF10● for maximum load requirements● TPE outer jacket● shielded● oil- and bio-oil-resistant● PVC-free/halogen-free● low-temperature-flexible● hydrolysis-resistant and microbe-resistantClass 7.4.4Image exemplary.Delivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF10.01.12 (12 x 0,14)C 7,5 36 80CF10.01.18 (18 x 0,14)C 10,0 67 110CF10.02.04 (4 x 0,25)C 6,5 25 52CF10.02.08 (8 x 0,25)C 7,5 40 75CF10.02.12 (12 x 0,25)C 9,5 64 118CF10.02.24 (24 x 0,25)C 13,0 109 212CF10.03.05.INI (5 x 0,34)C 7,0 32 62CF10.05.04 (4 x 0,5)C 7,0 38 68CF10.05.05 (5 x 0,5)C 7,5 55 91CF10.05.07 (7 x 0,5)C 8,5 54 95CF10.05.12 (12 x 0,5)C 11,5 102 192CF10.05.18 (18 x 0,5)C 13,5 143 270CF10.05.25 (25 x 0,5)C 14,5 167 280CF10.07.04 (4 G 0,75)C 7,5 47 86CF10.07.05 (5 G 0,75)C 7,5 57 95CF10.07.07 (7 G 0,75)C 9,0 85 137CF10.07.12 (12 G 0,75)C 12,5 138 244CF10.07.20 (20 G 0,75)C 15,0 205 346CF10.07.24 (24 G 0,75)C 16,5 239 419CF10.10.02 (2 x 1,0)C 7,0 38 70CF10.10.03 (3 G 1,0)C 7,5 47 84CF10.10.04 (4 G 1,0)C 8,0 59 100CF10.10.05 (5 G 1,0)C 8,5 71 101CF10.10.07 (7 G 1,0)C 10,0 105 166CF10.10.12 (12 G 1,0)C 13,5 169 293CF10.10.18 (18 G 1,0)C 16,5 240 407CF10.10.24 (24 G 1,0)C 18,0 305 506CF10.15.04 (4 G 1,5)C 9,0 96 144CF10.15.05 (5 G 1,5)C 9,5 108 163CF10.15.07 (7 G 1,5)C 11,5 155 225CF10.15.12 (12 G 1,5)C 15,5 235 387CF10.15.18 (18 G 1,5)C 20,0 361 585Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]New86... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.4.4Price indexCF10TPE5 x dDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF10.25.04 (4 G 2,5)C 11,0 126 180CF10.25.07 (7 G 2,5)C 13,5 221 331CF10.25.12 (12 G 2,5)C 19,0 373 624CF10.40.04 (4 G 4,0)C 11,5 200 290CF10.40.05 (5 G 4,0)C 13,5 246 353Control cableNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF10.10.12 – in your desired length (0,5 m steps)CF10 <strong>Chainflex</strong> ® series .10 Code nominal cross section .12 Number of coresPlease use www.chainflex.eu/en/CF10 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTel. +49-2203-96 49-0Fax +49-2203-96 49-222Control cable CF10 in storage and retrieval units for high-bay warehouses. E-Chain ® : System E2 medium950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF10(for up to 10 cuts of the same type)87


CF9.ULTPE5 x dTPE Control cable<strong>Chainflex</strong> ® CF9.UL● for maximum load requirements● TPE outer jacket● oil- and bio-oil-resistant● flame-retardant● PVC-free● low-temperature-flexible● hydrolysis-resistant and microbe-resistantHighly flexiblespecial conductorTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +100 °C, minimum bending radius 5 x d-40 °C to +100 °C, minimum bending radius 3 x d10 m/s, 6 m/sCenter element forhigh tensile stressesa max. 100 m/s 2Travel distanceTorsionFreely suspended and gliding travel distances up to 400 mand more, Class 4± 90°, with 1 m cable lengthBraiding in bundlesaround high-tensilecenter cordUV-resistantHighNominal voltage 300/500 V (following DIN VDE 0245).Testing voltage 2000 V (following DIN VDE 0281-2).Gusset-filledextruded TPEmixtureOilFlame-retardantOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Silicon-freeConductorFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Class 6.4.4Core insulationCore strandingMechanically high-quality TPE mixture.Number of cores < 12: cores stranded in a layer with shortpitch length.Number of cores ≥ 12: cores combined in bundles and strandedtogether around a centre for high tensile stresses withadapted, short pitch lengths and pitch directions, especiallylow-torsion structure.88Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF9.ULTPE5 x dCore identification Cores < 0,75 mm 2 : colour code in accordance with DIN 47100Cores ≥ 0,75 mm 2 : cores black with white numerals, one core green-yellow.CF9.UL.02.03.INI: brown, blue, blackCF9.UL.03.04.INI: brown, blue, black, whiteCF9.UL.03.05.INI: brown, blue, black, white, green-yellowOuter jacketLow-adhesion mixture on the basis of TPE, especially abrasion-resistant and highlyflexible, adapted to suit the requirements in Energy Chains ® .Colour: Steel blue (similar to RAL 5011)Control cableUL/CSA < 0,5 mm 2 : Style 10479 and 21529, 300 V, 90 °C≥ 0,5 mm 2 : Style 10258 and 21530, 600 V, 90 °CCEI Following CEI 20-35CELead freeClean roomTypical application arean for maximum load requirementsFollowing 2006/95/ECFollowing 2002/95/EC (RoHS).According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, testedby IPA according to standard 14644-1n almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF9UL(for up to 10 cuts of the same type)89


CF9.ULClass 6.4.4TPE5 x d90Image exemplary.TPE Control cable<strong>Chainflex</strong> ® CF9.UL● for maximum load requirements● TPE outer jacket● oil- and bio-oil-resistant● flame-retardant● PVC-free● low-temperature-flexible● hydrolysis-resistant and microbe-resistantDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF9.UL.02.02 2 x 0,25 5,0 5 28CF9.UL.02.03.INI 3 x 0,25 5,5 8 32CF9.UL.02.04 4 x 0,25 5,5 10 38CF9.UL.02.06 6 x 0,25 6,0 15 50CF9.UL.02.07 7 x 0,25 6,5 17 57CF9.UL.02.08 8 x 0,25 7,0 20 63CF9.UL.02.12 12 x 0,25 8,5 29 95CF9.UL.03.04.INI 4 x 0,34 6,0 13 43CF9.UL.03.05.INI (1) 5 x 0,34 6,0 16 51CF9.UL.03.06 6 x 0,34 6,5 20 58CF9.UL.03.08 (1) 8 x 0,34 7,5 26 76CF9.UL.05.02 2 x 0,5 6,0 10 44CF9.UL.05.03 (1) 3 x 0,5 6,5 15 52CF9.UL.05.04 4 x 0,5 7,0 20 62CF9.UL.05.05 (1) 5 x 0,5 7,0 24 72CF9.UL.05.07 7 x 0,5 8,5 34 97CF9.UL.05.12 12 x 0,5 11,0 58 196CF9.UL.05.18 18 x 0,5 13,5 87 242CF9.UL.05.25 (1) 25 x 0,5 14,5 120 305CF9.UL.05.36 (1) 36 x 0,5 18,5 173 456CF9.UL.07.05 5 G 0,75 8,0 36 94CF9.UL.07.07 7 G 0,75 9,5 51 128CF9.UL.07.12 12 G 0,75 12,5 87 240CF9.UL.07.20 (1) 20 G 0,75 15,5 144 342CF9.UL.07.25 25 G 0,75 16,5 180 412CF9.UL.10.03 3 G 1,0 7,5 29 78CF9.UL.10.04 4 G 1,0 8,0 39 98CF9.UL.10.05 (1) 5 G 1,0 8,5 48 112CF9.UL.10.12 12 G 1,0 13,5 116 287CF9.UL.10.18 18 G 1,0 16,5 173 394CF9.UL.10.25 25 G 1,0 18,5 240 520CF9.UL.15.04 4 G 1,5 9,0 58 127CF9.UL.15.05 5 G 1,5 9,5 72 152CF9.UL.15.07 7 G 1,5 11,0 101 198CF9.UL.15.12 12 G 1,5 15,5 173 385CF9.UL.15.18 18 G 1,5 19,0 260 535CF9.UL.15.25 25 G 1,5 22,0 360 685(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF9.UL.25.04 4 G 2,5 10,5 96 189CF9.UL.25.05 5 G 2,5 11,0 120 220CF9.UL.25.07 (1) 7 G 2,5 13,5 168 288CF9.UL.25.12 12 G 2,5 19,0 288 613CF9.UL.25.16 (1) 16 G 2,5 21,5 384 805CF9.UL.25.18 18 G 2,5 23,5 432 852CF9.UL.25.25 25 G 2,5 26,5 600 1163CF9.UL.40.04 4 G 4,0 12,0 154 278CF9.UL.60.04 4 G 6,0 13,5 231 382(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreCF9.ULTPE5 x dControl cableOrder example: CF9.UL.02.12 – in your desired length (0,5 m steps)CF9.UL <strong>Chainflex</strong> ® series .02 Code nominal cross section .12 Number of coresPlease use www.chainflex.eu/en/CF9UL for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® <strong>Chainflex</strong> ® <strong>cables</strong> in a rafting channel application.950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF9UL(for up to 10 cuts of the same type)91


CF10.ULTPE5 x dHighly flexiblespecial conductorTPE Control cable<strong>Chainflex</strong> ® CF10.UL● for maximum load requirements● TPE outer jacket● shielded● oil- and bio-oil-resistant● flame-retardant● PVC-free● low-temperature-flexible● hydrolysis-resistant and microbe-resistantCenter element forhigh tensile stressesTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +100 °C, minimum bending radius 5 x d-40 °C to +100 °C, minimum bending radius 3 x d10 m/s, 6 m/sa max. 100 m/s 2Braiding in bundlesaround high-tensilecenter cordTravel distanceFreely suspended and gliding travel distances up to 400 mand more, Class 4UV-resistantHighGusset-filledextrudedNominal voltage 300/500 V (following DIN VDE 0245).Testing voltage 2000 V (following DIN VDE 0281-2).Highly flexiblebraided coppershieldOilOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Pressure extrudedTPE blendFlame-retardantSilicon-freeConductorAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Core insulationMechanically high-quality TPE mixture.Class 6.4.492Image exemplary.Core stranding Number of cores < 12: cores stranded in a layer with shortpitch length.Number of cores ≥ 12: cores combined in bundles and strandedtogether around a centre for high tensile stresses withadapted, short pitch lengths and pitch directions, especiallylow-torsion structure.Core identification Cores < 0,75 mm 2 : colour code in accordance with DIN 47100Cores ≥ 0,75 mm 2 : cores black with white numerals, onecore green-yellow.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF10.ULTPE5 x dInner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Overall shield Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70%linear, approx. 90% optical.Outer jacketLow-adhesion mixture on the basis of TPE, especially abrasion-resistant and highlyflexible, adapted to suit the requirements in Energy Chains ® .Colour: Steel blue (similar to RAL 5011)Control cableUL/CSA < 0,5 mm 2 : Style 10479 and 21529, 300 V, 90 °C≥ 0,5 mm 2 : Style 10258 and 21530, 600 V, 90 °CCEI Following CEI 20-35CEFollowing 2006/95/ECLead freeClean roomTypical application arean for maximum load requirementsFollowing 2002/95/EC (RoHS).According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, testedby IPA according to standard 14644-1n almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF10UL(for up to 10 cuts of the same type)93


CF10.ULTPE5 x dTPE Control cable<strong>Chainflex</strong> ® CF10.UL● for maximum load requirements● TPE outer jacket● shielded● oil- and bio-oil-resistant● flame-retardant● PVC-free● low-temperature-flexible● hydrolysis-resistant and microbe-resistantClass 6.4.4Image exemplary.Delivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF10.UL.02.04 (4 x 0,25)C 7,0 25 71CF10.UL.02.08 (8 x 0,25)C 8,5 37 101CF10.UL.02.12 (12 x 0,25)C 10,0 63 153CF10.UL.02.24 (24 x 0,25)C 13,0 109 242CF10.UL.05.04 (4 x 0,5)C 8,5 37 101CF10.UL.05.05 (1) (5 x 0,5)C 8,5 43 111CF10.UL.05.12 (12 x 0,5)C 13,0 106 258CF10.UL.05.18 (1) (18 x 0,5)C 15,0 146 332CF10.UL.05.25 (25 x 0,5)C 16,0 185 411CF10.UL.07.03 (3 G 0,75)C 8,5 40 104CF10.UL.07.04 (4 G 0,75)C 9,0 49 123CF10.UL.07.05 (5 G 0,75)C 9,5 68 150CF10.UL.07.07 (7 G 0,75)C 11,0 90 194CF10.UL.07.12 (12 G 0,75)C 14,5 143 336CF10.UL.07.20 (1) (20 G 0,75)C 17,0 213 456CF10.UL.07.24 (1) (24 G 0,75)C 19,0 276 578CF10.UL.10.02 (1) (2 x 1,0)C 8,5 38 104CF10.UL.10.03 (1) (3 G 1,0)C 9,0 48 120CF10.UL.10.04 (4 G 1,0)C 9,5 71 155CF10.UL.10.05 (1) (5 G 1,0)C 10,5 83 174CF10.UL.10.07 (1) (7 G 1,0)C 12,0 111 230CF10.UL.10.12 (12 G 1,0)C 14,5 171 370CF10.UL.10.18 (1) (18 G 1,0)C 19,0 274 545CF10.UL.10.24 (1) (24 G 1,0)C 21,5 346 709CF10.UL.15.04 (4 G 1,5)C 10,5 192 94CF10.UL.15.05 (5 G 1,5)C 11,0 215 112CF10.UL.15.07 (7 G 1,5)C 13,0 149 279CF10.UL.15.12 (12 G 1,5)C 17,5 243 508CF10.UL.15.18 (18 G 1,5)C 21,5 375 724CF10.UL.25.04 (4 G 2,5)C 12,0 140 268CF10.UL.25.07 (7 G 2,5)C 15,0 227 404CF10.UL.25.12 (12 G 2,5)C 21,5 404 804CF10.UL.40.04 (4 G 4,0)C 13,5 206 369(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]94... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF10.ULTPE5 x dOrder example: CF10.UL.10.02 – in your desired length (0,5 m steps)CF10.UL <strong>Chainflex</strong> ® series .10 Code nominal cross section .02 Number of coresPlease use www.chainflex.eu/en/CF10UL for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsControl cableBraiding in bundlesTel. +49-2203-96 49-0Fax +49-2203-96 49-222Center element for hightensile stressesGusset-filled extrudedinner jacketTotal shield with optimizedbraiding anglePressure extrudedouter jacketThe special cable structure of <strong>Chainflex</strong> ® CF10.UL guarantees quality – also in the igus ® harnessing.950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF10UL(for up to 10 cuts of the same type)95


CF98TPE4 x dTPE Control cable<strong>Chainflex</strong> ® CF98● for maximum load requirements andespecially small radii up to 4 x d● TPE outer jacket● oil- and bio-oil-resistant● PVC-free/halogen-free● low-temperature-flexible● hydrolysis-resistant and microbe-resistantExtremely highlyflexible special alloy[∞C][∞C]RRTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +90 °C, minimum bending radius 4 x d-40 °C to +90 °C, minimum bending radius 3 x d10 m/s, 6 m/sa max. 100 m/s 2Travel distanceTorsionShort, very fast applications with small radii and tight designspace, Class 4± 90°, with 1 m cable lengthUVUV-resistantHighNominal voltage300/300 VTesting voltage1500 VBraiding in layerswith extremelyshort pitchHalOilOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (followingVDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.Halogen-free Following EN 50267-2-1.Gusset-filledextruded,halogen-freeTPE mixtureSilicon-freeConductorCore insulationCore strandingFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Conductor consisting of a highly flexible special alloy.Mechanically high-quality TPE mixture.Cores stranded in one layer with especially short pitch length.Class 7.4.4Core identification Colour code in accordance with DIN 47100.CF9.02.03.INI: brown, blue, blackCF9.03.04.INI: brown, blue, black, whiteOuter jacketLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® . Colour: Steel blue (similar to RAL 5011)CEFollowing 2006/95/ECLead freeFollowing 2002/95/EC (RoHS).96Image exemplary.Clean roomAccording to ISO Class 1. Outer jacket material complies withCF9.15.07, tested by IPA according to standard 14644-1... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.4.4Price indexCF98TPE4 x dTypical application arean for maximum load requirements at 4 x dn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for short, very fast applications with small radii and tight design spacen automatic insertion machines, automatic doors, clean room, very quick handlingDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF98.01.02 2 x 0,14 4,0 4,0 11CF98.01.03 (1) 3 x 0,14 4,5 6,3 14CF98.01.04 4 x 0,14 5,0 8,5 16CF98.01.07 (1) 7 x 0,14 6,0 14,0 21CF98.01.08 8 x 0,14 6,5 16,0 24CF98.02.03.INI 3 x 0,25 5,0 12,0 25CF98.02.04 4 x 0,25 5,5 16,0 30CF98.02.07 7 x 0,25 6,5 26,0 53CF98.02.08 8 x 0,25 7,0 30,0 60CF98.03.03 (1) 3 x 0,34 5,0 14,4 28CF98.03.04.INI 4 x 0,34 5,5 19,4 35CF98.03.07 7 x 0,34 7,0 32,0 55CF98.03.08 (1) 8 x 0,34 7,5 38,0 63CF98.05.04 4 x 0,5 6,0 31,0 40(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Control cableTel. +49-2203-96 49-0Fax +49-2203-96 49-222Order example: CF98.02.04 – in your desired length (0,5 m steps)CF98 <strong>Chainflex</strong> ® series .02 Code nominal cross section .04 Number of coresPlease use www.chainflex.eu/en/CF98 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTest data Page 32<strong>Chainflex</strong> ® CF98 for maximum load requirements and especially small radii at automatic doors.950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF98(for up to 10 cuts of the same type)97


CF99TPE4 x dExtremely highlyflexible special alloyTPE Control cable<strong>Chainflex</strong> ® CF99● for maximum load requirements andespecially small radii up to 4 x d● TPE outer jacket● shielded● oil- and bio-oil-resistant● PVC-free/halogen-free● low-temperature-flexible[∞C][∞C]RRTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +90 °C, minimum bending radius 4 x d-40 °C to +90 °C, minimum bending radius 3 x d10 m/s, 6 m/sa max. 100 m/s 2Braiding in layerswith extremelyshort pitchUVTravel distanceUV-resistantShort, very fast applications with small radii and tight designspace, Class 4HighNominal voltage300/300 VGusset-filledextrudedExtremely highlyflexible special shieldmade of alloyed wiresHalTesting voltageOil1500 VOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Halogen-free Following EN 50267-2-1.Pressure extruded,halogen-freeTPE blendSilicon-freeConductorCore insulationFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Conductor consisting of a highly flexible special alloy.Mechanically high-quality TPE mixture.Core strandingCores stranded in one layer with especially short pitch length.Core identification Colour code in accordance with DIN 47100.Class 7.4.4Inner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Overall shieldOuter jacketHighly flexible alloyed special shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion mixture on the basis of TPE, especially abrasion-resistantand highly flexible, adapted to suit the requirementsin Energy Chains ® .Colour: Steel blue (similar to RAL 5011)98Image exemplary.CEFollowing 2006/95/EC... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.4.4Price indexCF99TPE4 x dLead freeFollowing 2002/95/EC (RoHS).Clean roomTypical application arean for maximum load requirements at 4 x dAccording to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPAaccording to standard 14644-1n almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for short, very fast applications with small radii and tight design spacen automatic insertion machines, automatic doors, clean room, very quick handlingControl cableDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF99.01.02 (2 x 0,14)C 5,5 13,5 33,0CF99.01.03 (1) (3 x 0,14)C 6,0 16,5 37,0CF99.01.04 (4 x 0,14)C 6,0 21,0 43,0CF99.01.07 (1) (7 x 0,14)C 7,5 31,5 62,0CF99.01.08 (8 x 0,14)C 8,0 36,0 69,0CF99.02.03.INI (1) (3 x 0,25)C 6,5 25,0 48,0CF99.02.04 (4 x 0,25)C 6,5 30,0 56,0CF99.02.07 (7 x 0,25)C 8,0 48,0 85,0CF99.02.08 (1) (8 x 0,25)C 8,5 54,0 93,0CF99.03.03 (1) (3 x 0,34)C 6,5 27,0 51,0CF99.03.04.INI (1) (4 x 0,34)C 7,0 35,0 62,0CF99.03.08 (1) (8 x 0,34)C 9,0 64,0 105,0(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Order example: CF99.01.02 – in your desired length (0,5 m steps)CF99 <strong>Chainflex</strong> ® series .01 Code nominal cross section .02 Number of coresPlease use www.chainflex.eu/en/CF99 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsAutomatisierte Stapelanlage für Phosphorbildschirme: gerader Installationsraum, kleiner Biegeradius, 300.000 Doppelhübe pro Monat.950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF99(for up to 10 cuts of the same type)99


ata <strong>cables</strong>us <strong>cables</strong> Encoder <strong>cables</strong> Koax <strong>cables</strong>


<strong>Chainflex</strong> ®<strong>Chainflex</strong> ®cableJacketShieldMinimum bendingradius, moved[factor x d]Temperaturemovedfrom/to [°C]typesApprovals andstandardsOil-resistantTorsion resistantv max. [m/s]unsupportedv max. [m/s]glidinga max. [m/s 2 ]PageData <strong>cables</strong>CF240 PVC ✔ 10-12 -5/ +70 ✔ 3 2 20 102CF211 PVC ✔ 10 -5/ +70 ✔ 5 3 50 104CF112 PUR ✔ 10 -35/ +80 ✔ 10 5 80 106CF113 PUR ✔ 10 -35/ +80 ✔ 10 5 80 108CF11 TPE ✔ 10 -35/ +100 ✔ 10 6 100 110CF12 TPE ✔ 10 -35/ +100 ✔ 10 6 100 112Bus <strong>cables</strong> (with selection chart for <strong>Chainflex</strong> ® bus <strong>cables</strong>) 116CFBUS.PVC* PVC ✔ 12,5 -5/ +70 ✔ 2 30 118CFBUS.PUR* PUR ✔ 12,5 -35/ +70 ✔ 2 30 120CF BUS* TPE ✔ 10-12,5 -35/ +70 ✔ 10 6 100 122CF11.LC* TPE ✔ 10 -35/ +70 ✔ 10 6 100 126CF11.LC.D* TPE ✔ 10 -35/ +70 ✔ 10 6 100 128CF14 CAT5* TPE ✔ 12,5 -35/ +70 ✔ 10 6 100 130Measuring system <strong>cables</strong>CF211 PVC ✔ 10 -5/ +70 ✔ 5 3 50 132CF113.D PUR ✔ 10 -20/ +80 ✔ 5 3 50 136CF111.D TPE ✔ 12 -35/ +100 ✔ 2 30 142CF11.D TPE ✔ 10 -35/ +100 ✔ 10 6 100 146Koax <strong>cables</strong>CF KOAX1 TPE 10 -35/ +100 ✔ 10 5 100 152* Selection chart for bus <strong>cables</strong>:Field bus page 114High-speed bus page 116101


CF240PVC10-12 x dPVC Data cable<strong>Chainflex</strong> ® CF240● for high load requirements● PVC outer jacket● shielded● oil-resistant● flame-retardantFine-wire specialconductorTemperature range -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2,moved+5 °C to +70 °C for use in Energy Chains ® with > 50.000 cyclesMinimum bending radius 10 x d with < 10 m travel, minimum bendingradius 12 x d with ≥ 10 m travelTemperature rangefixed-20 °C to +70 °C, minimum bending radius 5 x dv max.unsupported/gliding 3 m/s, 2 m/sa max. 20 m/s 2Braiding in layerswith extremelyshort pitchTravel distance Freely suspended and gliding travel distances up to 50 m,Class 2Nominal voltage 300/300 V (following DIN VDE 0245).Testing voltage1500 VOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1),Class 2Flame-retardantAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Highly flexible braidedcopper shieldPressure extrudedSilicon-freeConductorCore insulationCore strandingFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Very finely stranded special cores of particularly high-flexdesign made of bare copper wires.Mechanically high-quality PVC mixture(following DIN VDE 0207 Part 4).The individual cores are stranded in layers with short pitch lengths.Core identification Colour code in accordance with DIN 47100.Intermediate sheathFoil taping over the external layer.Class 4.2.2Overall shieldOuter jacketExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion, oil-resistant mixture on the basis of PVC, adaptedto suit the requirements in Energy Chains ® (following DINVDE 0281 Part 13).Colour: Silver gray (similar to RAL 7001)UL/CSA Style 10467 and 2464, 300 V, 80 °CCEI Following CEI 20-35102Image exemplary.CEFollowing 2006/95/EC... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.2.2Price indexCF240PVC10-12 x dLead freeFollowing 2002/95/EC (RoHS)Clean roomTypical application arean for high load requirementsAccording to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPAaccording to standard 14644-1n light oil influencen preferably indoor applications, but also outdoor ones at temperatures > 5 °Cn especially for freely suspended and gliding travel distances up to 50 mn storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranesData cableDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF240.01.03 (3 x 0,14)C 4,5 16 35CF240.01.04 (4 x 0,14)C 5,0 18 38CF240.01.05 (5 x 0,14)C 5,5 20 42CF240.01.07 (7 x 0,14)C 6,0 25 51CF240.01.14 (14 x 0,14)C 7,0 42 76CF240.01.18 (18 x 0,14)C 8,0 48 90CF240.01.24 (24 x 0,14)C 9,5 60 113CF240.02.03 (3 x 0,25)C 5,5 21 40CF240.02.04 (4 x 0,25)C 5,5 24 48CF240.02.05 (5 x 0,25)C 6,0 27 52CF240.02.07 (7 x 0,25)C 7,0 35 66CF240.02.08 (8 x 0,25)C 7,5 40 74CF240.02.14 (14 x 0,25)C 8,0 57 100CF240.02.18 (18 x 0,25)C 9,0 71 122CF240.02.24 (24 x 0,25)C 11,0 92 174CF240.03.03 (3 x 0,34)C 5,5 24 45CF240.03.04 (4 x 0,34)C 6,0 28 51CF240.03.05 (5 x 0,34)C 6,5 32 58CF240.03.07 (7 x 0,34)C 7,0 43 75CF240.03.10 (10 x 0,34)C 8,5 55 110CF240.03.14 (14 x 0,34)C 8,5 71 116CF240.03.18 (18 x 0,34)C 10,0 87 140CF240.03.24 (24 x 0,34)C 12,0 115 203Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF240.02.03 – in your desired length (0,5 m steps)CF240 <strong>Chainflex</strong> ® series .02 Code nominal cross section .03 Number of coresPlease use www.chainflex.eu/en/CF240 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF240(for up to 10 cuts of the same type)103


CF211PVC10 x dCenter elementfor high tensilestressesFine-wire specialconductorPVC Data cable<strong>Chainflex</strong> ® CF211● for high load requirements● PVC outer jacket● shielded● oil-resistant● flame-retardantTemperature range -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2,moved+5 °C to +70 °C for use in Energy Chains ® with > 50.000 cycles.Minimum bending radius 10 x dTemperature rangefixed-20 °C to +70 °C, minimum bending radius 5 x dv max.unsupported/gliding 5 m/s, 3 m/sa max. 50 m/s 2Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3Nominal voltage 300/300 V (following DIN VDE 0245).2 cores eachstranded withshort pitchHighly flexiblebraided coppershieldTesting voltage1500 VOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1),Class 2Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).ConductorVery finely stranded special cores of particularly high-flexdesign made of bare copper wires.Core insulation Mechanically high-quality PVC mixture(following DIN VDE 0207 Part 4).Core stranding 2 cores each stranded in pairs with short pitch lengths, corepairs also stranded with short pitch lengths.Core identification Colour code in accordance with DIN 47100.Pressure extrudedIntermediate sheathFoil taping over the external layer.Class 5.3.2104Image exemplary.Overall shield Extremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Outer jacketLow-adhesion, oil-resistant mixture on the basis of PVC, adaptedto suit the requirements in Energy Chains ® (following DINVDE 0281 Part 13). Colour: Silver gray (similar to RAL 7001)UL/CSA < 0,5 mm 2 : Style 10467 and 2464, 300 V, 80°C≥ 0,5 mm 2 : Style 1729 and 2464, 300 V, 80 °CCEI Following CEI 20-35CELead freeClean roomFollowing 2006/95/ECFollowing 2002/95/EC (RoHS)According to ISO Class 2. Outer jacket material complies withCF5.10.07, tested by IPA according to standard 14644-1... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.2Price indexCF211PVC10 x dTypical application arean for high load requirementsn light oil influencen preferably indoor applications, but also outdoor ones at temperatures > 5 °Cn especially for freely suspended and gliding travel distances up to 100 mn storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranesData cableDelivery programPart No.Number of cores andconductor nominalExternaldiameterCopperindexWeight[kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF211.02.01.02 (1 x (2 x 0,25))C 5,0 16 35CF211.02.02.02 (2) (2 x (2 x 0,25))C 5,5 28 60CF211.02.03.02 (3 x (2 x 0,25))C 7,0 37 73CF211.02.04.02 (4 x (2 x 0,25))C 8,0 44 85CF211.02.05.02 (5 x (2 x 0,25))C 8,5 51 97CF211.02.06.02 (6 x (2 x 0,25))C 9,5 58 110CF211.02.08.02 (8 x (2 x 0,25))C 11,5 75 160CF211.02.10.02 (10 x (2 x 0,25))C 13,0 93 195CF211.02.14.02 (14 x (2 x 0,25))C 13,5 109 205CF211.03.03.02 (3 x (2 x 0,34))C 8,0 37 79CF211.03.08.02 (8 x (2 x 0,34))C 12,0 98 202CF211.03.10.02 (1) (10 x (2 x 0,34))C 12,0 118 254CF211.05.01.02 (1 x (2 x 0,5))C 5,5 23 50CF211.05.02.02 (2) (2 x (2 x 0,5))C 8,5 44 80CF211.05.03.02 (3 x (2 x 0,5))C 9,0 57 100CF211.05.04.02 (4 x (2 x 0,5))C 9,5 68 120CF211.05.05.02 (5 x (2 x 0,5))C 11,0 80 145CF211.05.06.02 (6 x (2 x 0,5))C 12,5 99 185CF211.05.08.02 (8 x (2 x 0,5))C 14,5 124 230CF211.05.10.02 (10 x (2 x 0,5))C 16,0 175 320CF211.05.14.02 (14 x (2 x 0,5))C 17,0 187 335Tel. +49-2203-96 49-0Fax +49-2203-96 49-222(1) Delivery time upon inquiryThe <strong>Chainflex</strong> ® types marked with (2) are <strong>cables</strong> designed as a star-quad.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF211.02.04.02 – in your desired length (0,5 m steps)CF211 <strong>Chainflex</strong> ® series .02 Code nominal cross section .04 Number of pairs .02 Identification pairsPlease use www.chainflex.eu/en/CF211 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsDelivery program Measuring system cablePage 128, CF211 (PVC)Page 136, CF111.D (TPE)Page 140, CF11.D (TPE)950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF211(for up to 10 cuts of the same type)105


CF112PUR10 x dEspecially bendingresistantfine-wirestranded conductorPUR Data cable<strong>Chainflex</strong> ® CF112● for high load requirements● PUR outer jacket● double-shielded, twisted-pair● oil-resistant and coolant-resistant● notch-resistant● PVC-free/halogen-free● flame-retardant● hydrolysis-resistant and microbe-resistantHighly flexible braidedcopper shieldCenter element forhigh tensile stressesTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +80 °C, minimum bending radius 10 x d-40 °C to +80 °C, minimum bending radius 5 x d10 m/s, 5 m/sa max. 80 m/s 22 cores each strandedwith short pitchTravel distance Freely suspended and gliding travel distances up to 100 m,Class 3Nominal voltage 300/300 V (following DIN VDE 0245).Testing voltage1500 VGusset-filledextrudedHighly flexiblebraided coppershieldPressure extruded,halogen-free PURblendOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3.Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 192).ConductorVery finely stranded special cores of particularly high-flex designmade of bare copper wires.Core insulation Mechanically high-quality TPE mixture.Core stranding 2 cores each stranded in pairs with short pitch lengths, corepairs also stranded with short pitch lengths.Core identification Colour code in accordance with DIN 47100Class 6.3.3106Image exemplary.Element shield Extremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Intermediate jacket PUR mixture adapted to suit the requirements in Energy Chains ® .Overall shieldOuter jacketExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion, highly abrasion-resistant mixture on the basisof PUR, adapted to suit the requirements in Energy Chains ®(following DIN VDE 0282 Part 10).Colour: gray (similar to RAL 7016)... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.3.3Price indexCF112PUR10 x dUL/CSA Style 10493 and 20233, 300 V, 80°CCEI Following CEI 20-35CEFollowing 2006/95/ECLead freeFollowing 2002/95/EC (RoHS).Data cableTypical application arean for high load requirementsn almost unlimited resistance to oiln indoor and outdoor applications with average sun radiationn especially for freely suspended and gliding travel distances up to 100 mn Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling,refrigerating sectorDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]CF112.02.02.02 (2 x (2 x 0,25)C)C 9,5 54 125CF112.02.03.02 (1) (3 x (2 x 0,25)C)C 10,0 68 144CF112.02.04.02 (4 x (2 x 0,25)C)C 11,0 78 159CF112.02.05.02 (1) (5 x (2 x 0,25)C)C 11,5 95 184CF112.02.06.02 (1) (6 x (2 x 0,25)C)C 12,0 107 210CF112.05.02.02 (1) (2 x (2 x 0,5)C)C 11,5 72 168CF112.05.03.02 (1) (3 x (2 x 0,5)C)C 12,0 95 192CF112.05.04.02 (4 x (2 x 0,5)C)C 12,5 113 221CF112.05.05.02 (1) (5 x (2 x 0,5)C)C 13,5 137 263CF112.05.06.02 (6 x (2 x 0,5)C)C 14,5 155 307Tel. +49-2203-96 49-0Fax +49-2203-96 49-222(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF112.02.04.02 – in your desired length (0,5 m steps)CF112 <strong>Chainflex</strong> ® series .02 Code nominal cross section .04 Number of pairs .02 Identification pairsPlease use www.chainflex.eu/en/CF112 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF112(for up to 10 cuts of the same type)107


CF113PUR10 x dEspecially bendingresistantfine-wirestranded conductorPUR Data cable<strong>Chainflex</strong> ® CF113● for high load requirements● PUR outer jacket● twisted-pair● oil-resistant and coolant-resistant● notch-resistant● PVC-free/halogen-free● flame-retardant● hydrolysis-resistant and microbe-resistantCenter element forhigh tensile stresses2 cores each strandedwith short pitchTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +80 °C, minimum bending radius 10 x d-40 °C to +80 °C, minimum bending radius 5 x d10 m/s, 5 m/s⁄a max. 80 m/s 2Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3Nominal voltage 300/300 V (following DIN VDE 0245).Gusset-filled extrudedHighly flexible braidedcopper shieldTesting voltage 1500 V.Oil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3.Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 192).Halogen-free Following EN 50267-2-1.Pressure extruded,halogen-free PURblendConductorCore insulationVery finely stranded special cores of particularly high-flex designmade of bare copper wires.Mechanically high-quality TPE mixture.Core stranding 2 cores each stranded in pairs with short pitch lengths, corepairs also stranded with short pitch lengths.Core identification Colour code in accordance with DIN 47100Class 6.3.3108Image exemplary.Intermediate jacket PUR mixture adapted to suit the requirements in Energy Chains ® .Overall shieldOuter jacketExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion, highly abrasion-resistant mixture on the basisof PUR, adapted to suit the requirements in Energy Chains ®(following DIN VDE 0282 Part 10). Colour: gray (similar to RAL 7016)... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.3.3Price indexCF113PUR10 x dUL/CSA Style 10493 and 20233, 300 V, 80°CCEI Following CEI 20-35CEFollowing 2006/95/ECLead freeFollowing 2002/95/EC (RoHS).Data cableTypical application arean for high load requirementsn almost unlimited resistance to oiln indoor and outdoor applications with average sun radiationn especially for freely suspended and gliding travel distances up to 100 mn Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling,refrigerating sectorDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]CF113.02.02.02 (2) (2 x (2 x 0,25))C 8,0 31 86CF113.02.03.02 (3 x (2 x 0,25))C 8,5 40 96CF113.02.04.02 (4 x (2 x 0,25))C 9,0 45 107CF113.02.05.02 (5 x (2 x 0,25))C 9,5 56 125CF113.02.06.02 (6 x (2 x 0,25))C 10,0 62 137CF113.05.02.02 (2) (2 x (2 x 0,5))C 10,0 50 127CF113.05.03.02 (1) (3 x (2 x 0,5))C 10,5 62 142CF113.05.04.02 (4 x (2 x 0,5))C 11,0 70 162CF113.05.05.02 (1) (5 x (2 x 0,5))C 11,5 84 185CF113.05.06.02 (6 x (2 x 0,5))C 12,5 95 207Tel. +49-2203-96 49-0Fax +49-2203-96 49-222(1) Delivery time upon inquiryThe <strong>Chainflex</strong> ® types marked with (2) are <strong>cables</strong> designed as a star-quad.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF113.02.06.02 – in your desired length (0,5 m steps)CF113 <strong>Chainflex</strong> ® series .02 Code nominal cross section .06 Number of pairs .02 Identification pairsPlease use www.chainflex.eu/en/CF113 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF113(for up to 10 cuts of the same type)109


CF11TPE10 x dEspecially bendingresistantfine-wirestranded conductorTPE Data cable<strong>Chainflex</strong> ® CF11● for maximum load requirements● TPE outer jacket● shielded● oil-resistant● bio-oil-resistant● PVC-free/halogen-free● hydrolysis-resistant and microbe-resistant2 cores eachstranded inespecially shortpitchTemperature rangemoved-35 °C to +100 °C, minimum bending radius 10 x dTemperature rangefixed-40 °C to +100 °C, minimum bending radius 5 x dv max.unsupported/gliding 10 m/s, 6 m/sa max. 100 m/s 2Travel distanceFreely suspended and gliding travel distances up to 400 mand more, Class 4UV-resistantHighNominal voltage 300/300 V (following DIN VDE 0245).Gusset-filledextrudedHighly flexible braidedcopper shieldTesting voltage1500 VOilOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.ConductorFine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Pressureextruded,halogen-freeTPE blendCore insulationMechanically high-quality TPE mixture.Core stranding 2 cores each stranded in pairs with short pitch lengths, corepairs also stranded with short pitch lengths.Core identification Cores < 1.0 mm 2 : colour code in accordance with DIN 47100Cores ≥ 1.0 mm 2 : cores black with white numeralsInner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Class 6.4.4Overall shieldOuter jacketCEExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion mixture on the basis of TPE, especially abrasion-resistantand highly flexible, adapted to suit the requirementsin Energy Chains ® .Colour: Steel blue (similar to RAL 5011)Following 2006/95/EC110Image exemplary.Lead freeFollowing 2002/95/EC (RoHS).... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF11TPE10 x dClean roomAccording to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPAaccording to standard 14644-1Typical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsData cableDelivery programBus cablePart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF11.01.04.02 (4 x (2 x 0,14))C 7,0 28 64CF11.01.18.02 (18 x (2 x 0,14))C 14,0 86 164CF11.02.02.02 (2) (2 x (2 x 0,25))C 6,5 25 52CF11.02.03.02 (3 x (2 x 0,25))C 8,0 34 60CF11.02.04.02 (4 x (2 x 0,25))C 9,0 44 80CF11.02.05.02 (5 x (2 x 0,25))C 9,0 55 100CF11.02.06.02 (6 x (2 x 0,25))C 10,0 66 127CF11.02.09.02 (9 x (2 x 0,25))C 12,5 92 198CF11.02.10.02 (10 x (2 x 0,25))C 13,0 99 200CF11.02.14.02 (14 x (2 x 0,25))C 13,5 120 238CF11.03.08.02 (8 x (2 x 0,34))C 12,5 90 154CF11.05.04.02 (4 x (2 x 0,5))C 10,0 91 108CF11.05.06.02 (6 x (2 x 0,5))C 11,5 95 190CF11.05.08.02 (8 x (2 x 0,5))C 14,0 131 250CF11.07.03.02 (3 x (2 x 0,75))C 11,0 77 131CF11.10.04.02 (4 x (2 x 1,0))C 12,0 121 180CF11.15.06.02 (6 x (2 x 1,5))C 17,0 242 419CF11.25.03.02 (3 x (2 x 2,5))C 16,5 210 410The <strong>Chainflex</strong> ® types marked with (2) are <strong>cables</strong> designed as a star-quad.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Order example: CF11.02.03.02 – in your desired length (0,5 m steps)CF11 <strong>Chainflex</strong> ® series .02 Code nominal cross section .03 Number of pairs .02 Identification pairsPlease use www.chainflex.eu/en/CF111 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsDelivery program Measuring system cablePage 128, CF211 (PVC)Page 136, CF111.D (TPE)Page 140, CF11.D (TPE)950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF11(for up to 10 cuts of the same type)111


CF12TPE10 x dEspecially bendingresistantfine-wirestranded conductorPressure extrudetelement jacketHighly flexiblebraided coppershieldTPE Data cable<strong>Chainflex</strong> ® CF12● for maximum load requirements● TPE outer jacket● double-shielded● oil-resistant● bio-oil-resistant● PVC-free/halogen-free● hydrolysis-resistant and microbe-resistantTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +100 °C, minimum bending radius 10 x d-40 °C to +100 °C, minimum bending radius 5 x d10 m/s, 6 m/sCenter element forhigh tensile stresses2 cores eachstranded in especiallyshort pitcha max. 100 m/s 2Travel distance Freely suspended and gliding travel distances up to 400 m,Class 4UV-resistantHighNominal voltage 300/300 V (following DIN VDE 0245).Testing voltage1500 VGusset-filled,pressure extrudedHighly flexiblesteel wire braidOilSilicon-freeOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (followingVDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Pressureextruded,halogen-freeTPE blendConductorCore insulationFine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Mechanically high-quality TPE mixture.Class 6.4.4112Image exemplary.Core stranding 2 cores each stranded in pairs with short pitch lengths, corepairs also stranded with short pitch lengths.Core identification Cores < 0,5 mm 2 : colour code in accordance with DIN47100Cores ≥ 0,5 mm 2 : cores black with white numeralsElement shield Extremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Element jacket TPE mixture adapted to suit the requirements in Energy Chains ®over pair shield.Inner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Overall shieldHighly flexible shield consisting of galvanized steel wire braid.Coverage approx. 70% linear, approx. 90% optical.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF12TPE10 x dOuter jacketCELead freeLow-adhesion mixture on the basis of TPE, especially abrasion-resistant and highlyflexible, adapted to suit the requirements in Energy Chains ® .Colour: Steel blue (similar to RAL 5011)Following 2006/95/ECFollowing 2002/95/EC (RoHS).Data cableClean roomAccording to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPAaccording to standard 14644-1Typical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 mn storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, outdoor cranes, low-temperature applications, for especially high EMC safetyDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]CF12.02.02.02 (2 x (2 x 0,25)C)C 11,0 27 152CF12.02.03.02 (1) (3 x (2 x 0,25)C)C 11,5 40 172CF12.02.04.02 (4 x (2 x 0,25)C)C 11,5 61 179CF12.02.05.02 (5 x (2 x 0,25)C)C 13,0 93 220CF12.05.03.02 (3 x (2 x 0,5)C)C 13,0 66 210CF12.05.04.02 (4 x (2 x 0,5)C)C 14,0 88 255CF12.05.05.02 (5 x (2 x 0,5)C)C 15,5 110 297CF12.05.06.02 (6 x (2 x 0,5)C)C 17,0 132 360CF12.05.08.02 (8 x (2 x 0,5)C)C 20,0 177 477CF12.05.10.02 (10 x (2 x 0,5)C)C 23,0 221 548CF12.05.14.02 (14 x (2 x 0,5)C)C 23,0 309 723CF12.10.06.02 (6 x (2 x 1,0)C)C 20,0 198 542Tel. +49-2203-96 49-0Fax +49-2203-96 49-222(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF12.02.03.02 – in your desired length (0,5 m steps)CF12 <strong>Chainflex</strong> ® series .02 Code nominal cross section .03 Number of pairs .02 Identification pairsPlease use www.chainflex.eu/en/CF12 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTest data Page 37950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF12(for up to 10 cuts of the same type)113


Selection<strong>Chainflex</strong> ®bus cableSelection chart field busfor <strong>Chainflex</strong> ® bus <strong>cables</strong><strong>Chainflex</strong> ® cable Profibus Interbus CAN Bus DeviceNetCF BUSCFBUS.001CFBUS.002CFBUS.003✔✔✔CFBUS.010CFBUS.011✔✔CFBUS.020CFBUS.021CFBUS.022✔✔✔CFBUS.030CFBUS.031✔✔CFBUS.035CF11.LCCF11.02.02.02.PBA.LC✔CF11.05.01.02.LCCF11.05.02.02.LC✔✔CF11.02.03.02.IB-SCF11.02.03.02.10.03.IB-S✔✔CF11.LC.DCF11.02.02.02.LC.DCF11.05.01.02.LC.D✔✔CF11.02.01.02.PBA.LC.DCF11.02.02.07.03.PBA.LC.DCF11.02.02.15.04.PBA.LC.D✔✔✔CF BUS.PVCCFBUS.PVC.001✔CFBUS.PVC.021CFBUS.PVC.022✔✔CF BUS.PURCFBUS.PUR.001✔CFBUS.PUR.021CFBUS.PUR.022✔✔CFROBOTRobot8.001✔Robot8.022✔114Selection chart high-speed bus page 116


Selection<strong>Chainflex</strong> ®bus cableCC-Link Characteristic - Flame- Halogen-free Pagewave impedance [Ω] retardant150 ✔ ✔ ✔ ✔ ✔ ✔ 122Bus cable150 ✔ ✔ ✔ ✔ ✔ ✔ 122150 ✔ ✔ ✔ ✔ ✔ ✔ 122100 ✔ ✔ ✔ ✔ ✔ ✔ 122100 ✔ ✔ ✔ ✔ ✔ ✔ 122120 ✔ ✔ ✔ ✔ ✔ ✔ 122120 ✔ ✔ ✔ ✔ ✔ ✔ 122120 ✔ ✔ ✔ ✔ ✔ ✔ 122120 ✔ ✔ ✔ ✔ ✔ ✔ 122120 ✔ ✔ ✔ ✔ ✔ ✔ 122✔ 110 ✔ ✔ ✔ ✔ ✔ ✔ 122150 ✔ ✔ ✔ 126120 ✔ ✔ ✔ 126Tel. +49-2203-96 49-0Fax +49-2203-96 49-222120 ✔ ✔ ✔ 126100 ✔ ✔ ✔ 126100 ✔ ✔ ✔ 126120 ✔ ✔ ✔ ✔ 128120 ✔ ✔ ✔ ✔ 128150 ✔ ✔ ✔ ✔ 128150 ✔ ✔ ✔ ✔ 128150 ✔ ✔ ✔ ✔ 128150 ✔ ✔ ✔ ✔ ✔ 118120 ✔ ✔ ✔ ✔ ✔ 118120 ✔ ✔ ✔ ✔ ✔ 118150 ✔ ✔ ✔ ✔ ✔ ✔ ✔ 120120 ✔ ✔ ✔ ✔ ✔ ✔ ✔ 120120 ✔ ✔ ✔ ✔ ✔ ✔ ✔ 120150 ✔ ✔ ✔ 222120 ✔ ✔ ✔ 222115


Selection<strong>Chainflex</strong> ®bus cableSelection chart high-speed busfor <strong>Chainflex</strong> ® bus <strong>cables</strong><strong>Chainflex</strong> ® cable Ethernet/ Ethernet/ GigE Profinet FireWireCAT5 CAT6CF BUS.PVCCFBUS.PVC.045 ✔ ✔CF BUS.PURCFBUS.PUR.045 ✔ ✔CF BUSCFBUS.040CFBUS.041CFBUS.042✔✔✔CFBUS.044 ✔ ✔CFBUS.045 ✔ ✔CFBUS.050✔CFBUS.055✔CFBUS.060✔CFBUS.065CFBUS.066CFBUS.070CF14 CAT5CF14.02.02.02.CAT5CF14.02.04.02.CAT5CF14.02.05.02.CAT5✔✔✔CFROBOTRobot8.045 ✔ ✔Selection chart field bus page 114116


Selection<strong>Chainflex</strong> ®bus cableUSB DVI Characteristic - Flame- Halogen-free Pagewave impedance [Ω] retardant100 ✔ ✔ ✔ ✔ ✔ 118Bus cable100 ✔ ✔ ✔ ✔ ✔ ✔ ✔ 120100 ✔ ✔ ✔ ✔ ✔ ✔ 122100 ✔ ✔ ✔ ✔ ✔ ✔ 122100 ✔ ✔ ✔ ✔ ✔ ✔ 122100 ✔ ✔ ✔ ✔ ✔ ✔ 122100 ✔ ✔ ✔ ✔ ✔ ✔ 122100 ✔ ✔ ✔ ✔ ✔ ✔ 122100 ✔ ✔ ✔ ✔ ✔ ✔ 122100 ✔ ✔ ✔ ✔ ✔ ✔ 122✔ 90 ✔ ✔ ✔ ✔ ✔ ✔ 122✔ 90 ✔ ✔ ✔ ✔ ✔ ✔ 122Tel. +49-2203-96 49-0Fax +49-2203-96 49-222✔ 100 ✔ ✔ ✔ ✔ ✔ ✔ 122100 ✔ ✔ ✔ ✔ 130100 ✔ ✔ ✔ ✔ 130100 ✔ ✔ ✔ ✔ 130100 ✔ ✔ ✔ 222117


CFBUS.PVCPVC12,5 x dNew! PVC Bus cable<strong>Chainflex</strong> ® CFBUS.PVC● for medium load requirements● PVC outer jacket● shielded● oil-resistant● flame-retardantEspecially bendingresistantfine-wirestranded conductorCores each stranded inespecially short pitchTemperature range -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2,moved+5 °C to +70 °C for use in Energy Chains ® with > 50.000 cycles.Minimum bending radius 12,5 x dTemperature range -20 °C to +70 °C, minimum bending radius 7,5 x dfixedv max.2 m/sunsupporteda max. 30 m/s 2Travel distance Freely suspended travel distances, Class 1.UV-resistantMediumNominal voltage30 VTesting voltage500 VBending-resistantbraided copper shieldOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1),Class 2Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1Pressure extruded,flame-retard PVCblendSilicon-freeConductorCore insulationFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).According to bus specification.Core strandingAccording to bus specification.Class 4.1.2118Image exemplary.Core identificationOverall shieldOuter jacketAccording to bus specificationSchedule delivery programBending-resistant, tinned braided copper shield.Coverage approx. 55% linear, approx. 80% optical.Low-adhesion, oil-resistant mixture on the basis of PVC, adaptedto suit the requirements in Energy Chains ® (following DINVDE 0281 Part 13). Colour: Red lilac (similar to RAL 4001)UL/CSA Style 1598 and 2571, 30 V, 80 °CCEI Following CEI 20-35... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.1.2Price indexCFBUS.PVCPVC12,5 x dCEFollowing 2006/95/ECLead freeFollowing 2002/95/EC (RoHS)Typical application arean for medium load requirementsn light oil influencen preferably indoor applications, but also outdoor ones at temperatures > 5 °Cn especially for freely suspended travel distancesn Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, handling,indoor cranesBus cableDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter in index [kg/km]cross section [mm 2 ] mm approx. [kg/km]ProfibusCFBUS.PVC.001 (2x0,25)C 8,0 22 71CAN-BusCFBUS.PVC.021 (2x0,5)C 8,5 27 81CFBUS.PVC.022 (2) (2x(2x0,5))C 8,5 38 94Ethernet/CAT5/GigECFBUS.PVC.045 (4x(2x0,15))C 7,0 34 62NewNewNewNewTel. +49-2203-96 49-0Fax +49-2203-96 49-222The <strong>Chainflex</strong> ® types marked with (2) are <strong>cables</strong> designed as a star-quad.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreDelivery program Characteris ticPart No.wave impedancein Ω approx.ProfibusNumber of coresand conductornominal crosssection [mm 2 ]CFBUS.PVC.001 150 (2x0,25)CCAN-BusCFBUS.PVC.021 120 (2x0,5)CCFBUS.PVC.022 120 (2x(2x0,5))CEthernet/CAT5/GigECFBUS.PVC.045 100 (4x(2x0,15))CColour codered, greenwhite, brownwhite, green, brown, yellow (star-quad stranding)white-blue/blue, white-orange/orange, white-green/green,white-brown/brownOrder example: CFBUS.PVC.001 – in your desired length (0,5 m steps)CFBUS.PVC <strong>Chainflex</strong> ® series .001 Code Bus typePlease use www.chainflex.eu/en/CFBUSPVC for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods * Die Lieferzeit bedeutet die Zeit bis zum Versand der Ware950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFBUSPVC(for up to 10 cuts of the same type)119


CFBUS.PURPUR12,5 x dNew! PUR Bus cable<strong>Chainflex</strong> ® CFBUS.PUR● for medium load requirements● PUR outer jacket● shielded● oil-resistant and coolant-resistant● notch-resistant● PVC-free/halogen-free● flame-retardant● hydrolysis-resistant and microbe-resistantEspecially bendingresistantfine-wirestranded conductorCores each stranded inespecially short pitchTemperature rangemoved-35 °C to +70 °C, minimum bending radius 10-12.5 x dTemperature rangefixed-40 °C to +70 °C, minimum bending radius 5 x dv max.2 m/sunsupported/glidinga max. 30 m/s 2Travel distance Freely suspended travel distances, Class 1.UV-resistantMediumNominal voltage30 VTesting voltage500 VBending-resistantbraided copper shieldOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3.Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1Pressure extruded,flame-retard PURblendConductorCore insulationFine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).According to bus specification.Core strandingAccording to bus specification.Class 4.1.3Core identification According to bus specificationSchedule delivery programOverall shield Bending-resistant, tinned braided copper shield.Coverage approx. 55% linear, approx. 80% optical.Outer jacketLow-adhesion, highly abrasion-resistant mixture on the basisof PUR, adapted to suit the requirements in Energy Chains ®(following DIN VDE 0282 Part 10). Colour: Red lilac (similar toRAL 4001)UL/CSA Style 1598 and 20236, 30 V, 80 °C120Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.1.3Price indexCFBUS.PURPUR12,5 x dCEI Following CEI 20-35CEDESINALead freeFollowing 2006/95/ECAccording to VDW, DESINA standardisationFollowing 2002/95/EC (RoHS)Bus cableTypical application arean for medium load requirementsn almost unlimited resistance to oiln indoor and outdoor applications without direct sun radiationn especially for freely suspended travel distancesn Bus connection cable for machining units/machine tools, low-temperature applicationsDelivery programPart No.ProfibusCFBUS.PUR.001 (2x0,25)C 8,0 22 67CAN-BusCFBUS.PUR.021 (2x0,5)C 8,5 27 76CFBUS.PUR.022 (2) (2x(2x0,5))C 8,5 38 89Ethernet/CAT5/GigENumber of cores andconductor nominalcross section [mm 2 ]Externaldiameter inmm approx.Copperindex[kg/km]CFBUS.PUR.045 (4x(2x0,15))C 7,0 34 62The <strong>Chainflex</strong> ® types marked with (2) are <strong>cables</strong> designed as a star-quad.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]NewNewNewNewTel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery program Characteris ticPart No.wave impedancein Ω approx.ProfibusNumber of coresand conductornominal crosssection [mm 2 ]CFBUS.PUR.001 150 (2x0,25)CCAN-BusCFBUS.PUR.021 120 (2x0,5)CCFBUS.PUR.022 120 (2x(2x0,5))CEthernet/CAT5/GigECFBUS.PUR.045 100 (4x(2x0,15))CColour codered, greenwhite, brownwhite, green, brown, yellow (star-quad stranding)white-blue/blue, white-orange/orange, white-green/green,white-brown/brownOrder example: CFBUS.PUR.001 – in your desired length (0,5 m steps)CFBUS.PUR <strong>Chainflex</strong> ® series .001 Code Bus typePlease use www.chainflex.eu/en/CFBUSPUR for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods * Die Lieferzeit bedeutet die Zeit bis zum Versand der Ware950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFBUSPUR(for up to 10 cuts of the same type)121


CFBUSTPE10-12.5 x dTPE Bus cable<strong>Chainflex</strong> ® CFBUS● for maximum load requirements● TPE outer jacket● shielded● oil-resistant● bio-oil-resistant● flame-retardant● hydrolysis-resistant and microbe-resistantEspecially bendingresistantfine-wirestranded conductorTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +70 °C, minimum bending radius 10-12.5 x d-40 °C to +70 °C, minimum bending radius 5 x d10 m/s, 6 m/sa max. 100 m/s 2Cores each stranded inespecially short pitchTravel distance Freely suspended and gliding travel distances up to 400 m,Class 4UV-resistantMediumGusset-filledextrudedNominal voltageTesting voltage30 V500 VHighly flexible braidedcopper shieldOilOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Flame-retardantAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Pressureextruded,flame-retardTPE blendSilicon-freeConductorFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Core insulationAccording to bus specification.Core strandingAccording to bus specification.Class 6.4.4Core identification According to bus specification Schedule delivery programInner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Overall shield Extremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.122Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCFBUSTPE10-12.5 x dOuter jacketLow-adhesion mixture on the basis of TPE, especially abrasion-resistant and highlyflexible, adapted to suit the requirements in Energy Chains ® . Colour: Red lilac (similarto RAL 4001)UL/CSA Style 1589 and 21371, 30 V, 80 °CCEFollowing 2006/95/ECBus cableDESINAAccording to VDW, DESINA standardisationLead freeFollowing 2002/95/EC (RoHS).Clean roomAccording to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested byIPA according to standard 14644-1Typical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications without direct sun radiationn especially for freely suspended and gliding travel distances up to 400 mn bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quickhandling, clean room, semiconductor insertion, indoor cranes, low-temperature applicationsTel. +49-2203-96 49-0Fax +49-2203-96 49-222Test data Page 28FireWire cable for moving energy supplies in digital camera technology.950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFBUS (for up to 10 cuts of the same type)123


CFBUSTPE10-12.5 x dTPE Bus cable<strong>Chainflex</strong> ® CFBUS● for maximum load requirements● TPE outer jacket● shielded● oil-resistant● bio-oil-resistant● flame-retardant● hydrolysis-resistant and microbe-resistantClass 6.4.4Image exemplary.Delivery program Number of cores and External Copper WeightPart No.conductor nominal cross diameter in index [kg/km]section [mm 2 ]mm approx. [kg/km]Profibus (minimum bending radius 10 x d)CFBUS.001 (2x0,25)C 8,5 23 70CFBUS.002 4x1,5+(2x0,25)C 12,5 96 175CFBUS.003 3x0,75+(2x0,25)C 11,0 58 121Interbus (minimum bending radius 10 x d)CFBUS.010 (3x(2x0,25))C 8,5 42 83CFBUS.011 (3x(2x0,25)+3x1,0)C 10,0 74 135CAN-BUS/Fieldbus (minimum bending radius 10 x d)CFBUS.020 (2) (2x(2x0,25))C 6,5 33 66CFBUS.021 (2x0,5)C 8,5 36 77CFBUS.022 (2) (2x(2x0,5))C 8,5 45 83DeviceNet (minimum bending radius 10 x d)CFBUS.030 Drop ((2xAWG24)C+2xAWG22)C 7,5 33 65CFBUS.031 Trunk ((2xAWG18)C+2xAWG15)C 11,5 96 110CC-Link (Biegeradius min. 10 x d)CFBUS.035 (3xAWG20)C 8,5 44 90Ethernet/CAT5/GigE (minimum bending radius 12,5 x d)CFBUS.040 (2) (2x(2x0,25))C 7,0 33 43CFBUS.041 (4x(2x0,25))C 10,0 46 101CFBUS.042 (1) (5x(2x0,25))C 10,5 53 106CFBUS.044 (4x(2x0,15))C 8,0 35 79CFBUS.045 (4x(2x0,15))C 8,0 35 79Ethernet/CAT6 (minimum bending radius 12,5 x d)CFBUS.050 (4x(2x0,14)C)C 10,0 77 131FireWire (minimum bending radius 12,5 x d)CFBUS.055 (2x(2x0,15)C+2x(0,34)C) 7,5 42 81Profinet (minimum bending radius 12,5 x d)CFBUS.060 (4x0,38)C 7,5 37 71USB (minimum bending radius 12,5 x d)CFBUS.065 (2x0,5+1x(2x0,08))C 5,0 26 45CFBUS.066 (2x0,5+1x(2x0,24))C 6,0 32 56DVI (minimum bending radius 12,5 x d)CFBUS.070 (4x(2x0,08+2x0,08+3x0,08))C 9 33 92(1) Delivery time upon inquiryThe <strong>Chainflex</strong> ® types marked with (2) are <strong>cables</strong> designed as a star-quad.Other types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreNew124... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCFBUSTPE10-12.5 x dDelivery programPart No.Characteris - Number of corestic wave and conductorimpedance nominal crossProfibusin Ω approx. section [mm 2 ]CFBUS.001 150 (2x0,25)CCFBUS.002 150 4x1,5+(2x0,25)CCFBUS.003 150 3x0,75+(2x0,25)CInterbusCFBUS.010 100 (3x(2x0,25))CCFBUS.011 100 (3x1,0+3x(2x0,25))CCAN-BUS/FeldbusCFBUS.020 120 (2x(2x0,25))CCFBUS.021 120 (2x0,5)CCFBUS.022 120 (2x(2x0,5))CDeviceNetCFBUS.030 Drop 120 (1x2xAWG24)+(1x2xAWG22)CCFBUS.031 Trunk 120 (1x2xAWG18)+(1x2xAWG15)CCC-LinkCFBUS.035 110 (3xAWG20)CEthernet/CAT5/GigECFBUS.040 100 (2x(2x0,25))CCFBUS.041 100 (4x(2x0,25))CCFBUS.042 100 (5x(2x0,25))CCFBUS.044 100 (4x(2x0,15))CCFBUS.045 100 (4x(2x0,15))CEthernet/CAT6CFBUS.050 100 (4x(2x0,14)C)CFireWireCFBUS.055 100 2x(2x0,15)C+2x(0,34)CProfinetCFBUS.060 100 (4x0,38)CUSBCFBUS.065 90 2x0,52x0,08CFBUS.066 90 2x0,52x0,24DVICFBUS.070 100 (4x(2x0,08+2x0,08+3x0,08))CColour codered, greenblack with white numbersred/greenblack, blue, green-yellowred/greenwhite/brown, green/yellow, gray/pinkred, blue, green-yellowwhite/brown, green/yellow, gray/pinkwhite, green, brown, yellow (star-quad stranding)white, brownwhite, green, brown, yellow (star-quad stranding)white/bluered/blackwhite/bluered/blackwhite, yellow, bluewhite, green, brown, yellow (star-quad stranding)white/brown, green/yellow, gray/pink, blue/redwhite/brown, green/yellow, gray/pink, blue/red, black/violetwhite/brown, green/yellow, gray/pink, blue/redwhite-blue/blue, white-orange/orange, white-green/green,white-brown/brownwhite/blue, white/orange, white/green, white/brownorange/blue, green/redblack, whitewhite, yellow, blu, orange (star-quad stranding)red, blackwhite/greenred, blackwhite/green4x white/yellow with elementjacket in blue, black, white, redwhite/brown, green, yellow, grayBus cableTel. +49-2203-96 49-0Fax +49-2203-96 49-222Technical informationThe USB, FireWire and GigE-<strong>cables</strong> shown on these pages were developed for the ambitious industrialusage in E-Chains ® . High proofness to oil and lubricants is as secured as protection against electromagne -tical interferences. This high mechanical service life was reached with the usage of high quality materialswhich even care for the electrical safeness. In single cases communication errors can occur, if very differenthardware and software is combined. We recommend tests with all components and the <strong>cables</strong> beforestarting serial production, to get the proove for a perfect running system. Of course we support you withthe details of these electrical tests. Just give us a call!950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFBUS (for up to 10 cuts of the same type)125


CF11.LCTPE10 x dEspecially bendingresistantfine-wirestranded conductorTPE Bus cable<strong>Chainflex</strong> ® CF11.LC (low capacitance)● for maximum load requirements● TPE outer jacket● shielded● oil-resistant● bio-oil-resistant● PVC-free/halogen-free● UV-resistant● hydrolysis-resistant and microbe-resistantTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +70 °C, minimum bending radius 10 x d-40 °C to +70 °C, minimum bending radius 5 x d10 m/s, 6 m/sa max. 100 m/s 2Cores eachstranded inespeciallyshort pitchTravel distance Freely suspended and gliding travel distances up to 400 m,Class 4UV-resistantHighGusset-filledextrudedNominal voltageTesting voltage30 V500 VHighly flexiblebraided coppershieldOilSilicon-freeOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Pressureextruded,halogen-freeTPE blendConductorCore insulationFine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).According to bus specification.Core strandingAccording to bus specification.Core identification According to bus specification Schedule delivery programClass 6.4.4Inner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Overall shieldOuter jacketExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® . Colour: Steel blue (similar to RAL 5011)126Image exemplary.CEFollowing 2006/95/EC... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF11.LCTPE10 x dLead freeFollowing 2002/95/EC (RoHS).Clean roomTypical application arean for maximum load requirementsAccording to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPAaccording to standard 14644-1n almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 mn bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quickhandling, clean room, semiconductor insertion, indoor cranes, low-temperature applicationsBus cableDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]Interbuscross section [mm 2 ] approx. [mm] [kg/km]CF11.02.03.02.IB-S (3x(2x0,25))C 8,5 42 83CF11.02.03.02.10.03.IB-S (3x(2x0,25)+3x1,0)C 10,0 74 135CAN-BusCF11.05.01.02.LC (2x0,5)C 8,5 36 77CF11.05.02.02.LC (2) (2x(2x0,5))C 8,5 45 83ProfibusCF11.02.02.02.PBA.LC (2) (2x(2x0,25))C 8,5 33 80Tel. +49-2203-96 49-0Fax +49-2203-96 49-222The <strong>Chainflex</strong> ® types marked with (2) are <strong>cables</strong> designed as a star-quad.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreDelivery program Characteris - Number of coresPart No.tic wave and conductorimpedance nominal crossInterbusapprox. [Ω] section [mm 2 ]CF11.02.03.02.IB-S 100 (3x(2x0,25))CCF11.02.03.02.10.03.IB-S 100 (3x2x0,25+3x1,0)CCAN-BusCF11.05.01.02.LC 120 (2x0,5)CCF11.05.02.02.LC 120 (2x(2x0,5))CProfibusCF11.02.02.02.PBA.LC 150 (2x(2x0,25))CColour codewhite/brown, green/yellow, gray/pinkwhite/brown, green/yellow, gray/pinkred, blue, green-yellowwhite, brownwhite, green, brown, yellow (star-quad stranding)green/red, yellow/brown950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF11LC (for up to 10 cuts of the same type)127


CF11.LC.DTPE10 x dEspecially bendingresistantfine-wirestranded conductorTPE Bus cable<strong>Chainflex</strong> ® CF11.LC.D (low capacitance)● for maximum load requirements● TPE outer jacket● shielded● PVC-free/halogen-free● oil-resistant● bio-oil-resistant● hydrolysis-resistant and microbe-resistantTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +70 °C, minimum bending radius 10 x d-40 °C to +70 °C, minimum bending radius 5 x d10 m/s, 6 m/sa max. 100 m/s 2Cores eachstranded inespeciallyshort pitchTravel distance Freely suspended and gliding travel distances up to 400 m,Class 4UV-resistantMediumGusset-filledextrudedHighly flexiblebraided coppershieldNominal voltageTesting voltageOilSilicon-free30 V500 VOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Pressureextruded,halogen-freeTPE blendConductorCore insulationFine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).According to bus specification.Core strandingAccording to bus specification.Core identification According to bus specification Schedule delivery programClass 6.4.4Inner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Overall shieldOuter jacketCEExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® . Colour: Red lilac (similar to RAL 4001)Following 2006/95/EC128Image exemplary.DESINAAccording to VDW, DESINA standardisation... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF11.LC.DTPE10 x dLead freeFollowing 2002/95/EC (RoHS).Clean roomTypical application arean for maximum load requirementsAccording to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPAaccording to standard 14644-1n almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications without direct sun radiationn especially for freely suspended and gliding travel distances up to 400 mn bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quickhandling, clean room, semiconductor insertion, indoor cranes, low-temperature applicationsBus cableDelivery programPart No.ProfibusCF11.02.01.02.PBA.LC.D (2x0,25)C 8,5 23 70CF11.02.02.07.03.PBA.LC.D 3x0,75+(2x0,25)C 11,0 58 121CF11.02.02.15.04.PBA.LC.D 4x1,5+(2x0,25)C 12,5 96 175Fieldbus (CAN-Bus)Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF11.02.02.02.LC.D (2) (2x(2x0,25))C 6,5 33 66CF11.05.01.02.LC.D (2x0,5)C 8,5 36 77The <strong>Chainflex</strong> ® types marked with (2) are <strong>cables</strong> designed as a star-quad.Other types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery programCharacteris - Number of coresPart No.tic wave and conductorimpedance nominal crossProfibusapprox. [Ω] section [mm 2 ]CF11.02.01.02.PBA.LC.D 150 (2x0,25)CCF11.02.02.07.03.PBA.LC.D 150 3x0,75+(2x0,25)CCF11.02.02.15.04.PBA.LC.D 150 4x1,5+(2x0,25)CFieldbus (CAN-Bus)CF11.02.02.02.LC.D 120 (2x(2x0,25))CCF11.05.01.02.LC.D 120 (2x0,5)CColour codered/greenblack with white numbersred/greenblack, blue, green-yellowred/greenwhite, green, brown, yellow (star-quad stranding)white/brownOrder example: CF11.02.03.02.IB-S – in your desired length (0,5 m steps)CF11.LC <strong>Chainflex</strong> ® series .02 Code nominal cross section .03 Number of pairs.02 Identification pairs .IB-S Special identificationPlease use www.chainflex.eu/en/CF11LCD for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTest data Page 30950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF11LCD (for up to 10 cuts of the same type)129


CF14TPE12,5 x dEspecially bendingresistantfine-wirestranded conductorTPE Bus cable<strong>Chainflex</strong> ® CF14 CAT5● Ethernet special cable for maximum load requirements● TPE outer jacket● oil-resistant● bio-oil-resistant● PVC-free/halogen-free● UV-resistant● hydrolysis-resistant and microbe-resistant2 cores each strandedin especially short pitch,PP special insulationTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +70 °C, minimum bending radius 12,5 x d-40 °C to +70 °C, minimum bending radius 7,5 x d10 m/s, 6 m/sa max. 100 m/s 2Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3UV-resistantMediumGusset-filledextrudedNominal voltageTesting voltage30 V500 VHighly flexible braidedcopper shieldOilSilicon-freeOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Pressureextruded,halogen-freeTPE blendConductorCore insulation19-wire conductor consisting of bare copper wires in especiallybending-resistant braiding quality.Special PP-isolating mixture.Core stranding2 cores each stranded in pairs with short pitch lengths, corepairs also stranded with short pitch lengths.Core identification Colour code in accordance with DIN 47100Class 6.3.4Inner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Overall shieldOuter jacketExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® . Colour: Red lilac (similar to RAL 4001)130Image exemplary.CEFollowing 2006/95/EC... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.3.4Price indexCF14TPE12,5 x dDESINAAccording to VDW, DESINA standardisationLead freeClean roomFollowing 2002/95/EC (RoHS).According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPAaccording to standard 14644-1Bus cableTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications without direct sun radiationn especially for freely suspended and gliding travel distances up to 100 mn ethernet cable for Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling,clean room, semiconductor insertion, indoor cranes, low-temperature applicationsDelivery programPart No.Ethernet CAT5Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF14.02.02.02.CAT5 (2) (2x(2x0,25))C 7,0 33 43CF14.02.04.02.CAT5 (4x(2x0,25))C 10,0 46 101CF14.02.05.02.CAT5 (5x(2x0,25))C 10,5 53 106The <strong>Chainflex</strong> ® types marked with (2) are <strong>cables</strong> designed as a star-quad.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery programCharacteris - Number of coresPart No.tic wave and conductorimpedance nominal crossEthernet CAT5approx. [Ω] section [mm 2 ]CF14.02.02.02.CAT5 100 (2x(2x0,25))CCF14.02.04.02.CAT5 100 (4x(2x0,25))CCF14.02.05.02.CAT5 100 (5x(2x0,25))CColour codewhite, green, brown, yellow (star-quad stranding)white/brown, green/yellow, gray/pink, blue/redwhite/brown, green/yellow, gray/pink, blue/red,black/violetOrder example: CF14.02.02.02.CAT5 – in your desired length (0,5 m steps)CF14 CAT5 <strong>Chainflex</strong> ® series .02 Code nominal cross section .02 Number of pairs.02 Identification pairs .CAT5 CAT5 identificationPlease use www.chainflex.eu/en/CF14 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTest data Page 26More CAT5/CAT6 <strong>cables</strong> Page 122, CFBUS950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF14(for up to 10 cuts of the same type)131


CF211PVC10 x dCenter elementfor high tensilestressesPVC Measuring system cable<strong>Chainflex</strong> ® CF211● for high load requirements● PVC outer jacket● shielded● oil-resistant● flame-retardantFine-wire specialconductorTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-5 °C to +70 °C, minimum bending radius 10 x d-20 °C to +70 °C, minimum bending radius 5 x d5 m/s, 3 m/sa max. 50 m/s 2Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3Cores each strandedwith short pitchNominal voltageTesting voltage30 V500 VOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1),Class 2Flame-retardantAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Highly flexiblebraided coppershieldSilicon-freeConductorFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Very finely stranded special cores of particularly high-flexdesign made of bare copper wires.Pressure extrudedCore insulationCore strandingMechanically high-quality PP mixture.According to measuring system specification.Core identificationElement shieldAccording to measuring system specificationSchedule delivery programExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Intermediate sheathFoil taping over the external layer.Class 5.3.2132Image exemplary.Element jacket TPE mixture adapted to suit the requirements in Energy Chains ®over pair shield.Overall shield Extremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Outer jacketLow-adhesion, oil-resistant mixture on the basis of PVC,adapted to suit the requirements in Energy Chains ®(following DIN VDE 0282 Part 10).Colour: Silver gray (similar to RAL 7001)... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.2Price indexCF211PVC10 x dUL/CSA Style 1589 and 2502, 30 V, 80 °CCEI Following CEI 20-35CEFollowing 2006/95/ECLead freeFollowing 2002/95/EC (RoHS)Clean roomAccording to ISO Class 2. Outer jacket material complies with CF5.10.07, tested byIPA according to standard 14644-1Measuring system cableTypical application arean for high load requirementsn light oil influencen preferably indoor applications, but also outdoor ones at temperatures > 5 °Cn especially for freely suspended and gliding travel distances up to 100 mn storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranesTel. +49-2203-96 49-0Fax +49-2203-96 49-222Three Energy Chain Systems ® in several axes fitted with specially <strong>cables</strong> from igus ® . E-Chain ® : System E4/00 and System E4/0950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF211M (for up to 10 cuts of the same type)133


CF211PVC10 x dPVC Measuring system cable<strong>Chainflex</strong> ® CF211● for high load requirements● PVC outer jacket● shielded● oil-resistant● flame-retardantDelivery program*Part No.CF211.001Number of cores and External Copper Weightconductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km](3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0 61 100CF211.002 (3x(2x0,14)C+2x(0,5)C)C 9,0 63 110CF211.006(3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 9,5 72 120CF211.009 (4x(2x0,25)+2x0,5)C 9,0 51 111CF211.010 (4x(2x0,25)+2x1,0)C 9,5 74 141CF211.011 (4x(2x0,34)+4x0,5)C 9,0 75 135CF211.014 (4x(2x0,25)C+1x2x0,5)C 13,0 84 211CF211.016 (3x(2x0,25)C)C 11,0 85 170CF211.017(4x(2x0,14)+4x1,0+(4x0,14)C)C 9,0 85 124CF211.018 (2x(2x0,25)+2x0,5)C 7,0 41 62CF211.019(3x0,25+3x(2x0,25)C+2x1,0)C 9,0 82 115CF211.027 (5x(2x0,14)+2x0,5)C 9,0 45 102Other types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreImage exemplary.Order example: CF211.001 – in your desired length (0,5 m steps)CF211 <strong>Chainflex</strong> ® series .001 Code Measuring systemPlease use www.chainflex.eu/en/CF211M for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsClass 5.3.2134... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.2Price indexCF211PVC10 x dDeliveryprogramPart No.Number of cores andconductor nominal crosssection [mm 2 ]Core group Colour codeCF211.001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 3x(2x0,14)C4x0,142x0,5yellow/green, black/brown, red/orangegray, blue, white-yellow, white-blackbrown-red, brown-blueCF211.002(3x(2x0,14)C+2x(0,5)C)C 3x(2x0,14)C2x(0,5)Cgreen/yellow, black/brown, red/orangeblack, redCF211.006 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 3x(2x0,14)C4x0,144x0,232x0,5green/yellow, black/brown, red/orangegray, blue, white-yellow, white-blackbrown-yellow, brown-gray, green-black, green-redbrown-red, brown-blueCF211.009(4x(2x0,25)+2x0,5)C 4x(2x0,25)2x0,5brown/green, blue/violet, gray/pink, red/blackwhite, brownCF211.010(4x(2x0,25)+2x1,0)C 4x(2x0,25)2x1,0brown/green, blue/violet, gray/pink, red/blackwhite, brownCF211.011(4x(2x0,34)+4x0,5)C 4x(2x0,34)4x0,5black/brown, red/orange, yellow/green, blue/violetblue-white, black-white, red-white, yellow-whiteCF211.014(4x(2x0,25)C+1x2x0,5)C 4x(2x0,25)C2x0,5white/brown, green/yellow, gray/pink, blue/redblack (numeral printing 1-2)CF211.016(3x(2x0,25)C)C 3x(2x0,25)C white/brown, green/yellow, gray/pinkCF211.017 (4x(2x0,14)+4x1,0+(4x0,14)C)C (4x0,14)C4x(2x0,14)4x1,0blue-black, red-black, yellow-black, green-blackred/black, green/brown, yellow/violet, pink/graywhite-green, brown-green, blue, whiteCF211.018(2x(2x0,25)+2x0,5)C 2x(2x0,25)2x0,5red/black, gray/pinkwhite, brownCF211.019 (3x0,25+3x(2x0,25)C+2x1,0)C 3x(2x0,25)C(3x0,25)(2x1,0)brown/green, pink/gray, red/blackblue, yellow, violetwhite, brownCF211.027(5x(2x0,14)+2x0,5)C 5x(2x0,14)(2x0,5)green/brown, gray/yellow, white/violet, black/red, blue/pinkwhite-green, white-redMeasuring system cableTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF211M (for up to 10 cuts of the same type)135


CF113.DPUR10 x dEspecially bendingresistantfine-wirestranded conductorPUR Measuring system cable<strong>Chainflex</strong> ® CF113.D● for maximum load requirements● PUR outer jacket● shielded● oil-resistant and coolant-resistant● notch-resistant● flame-retardant● hydrolysis-resistant and microbe-resistant● PVC-free/halogen-freeHighly flexible braidedcopper shieldCenter element for hightensile stressesTemperature rangemovedTemperature rangefixedv max.unsupported/gleitend-20 °C to +80 °C, minimum bending radius 10 x d-40 °C to +80 °C, minimum bending radius 5 x d5 m/s, 3 m/sa max. 50 m/s 2Cores each stranded inespecially short pitchTravel distance Freely suspended and gliding travel distances up to 100 m,Class 3UV-resistantMediumGusset-filled extrudedNominal voltage30 VTesting voltage500 VHighly flexible braidedcopper shieldOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3Offshore MUD-resistant following NEK 606Pressure extrudedPUR blendFlame-retardantHalogen-free Following EN 50267-2-1According to IEC 60332-1-2, CEI 20-34, FT1, VW-1Silicon-freeConductorFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Class 6.3.3136Image exemplary.Core insulationCore strandingCore identificationElement shieldMechanically high-quality PP mixture.According to measuring system specificationAccording to measuring system specificationSchedule Delivery ProgramExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.3.3Price indexCF113.DPUR10 x dInner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Overall shield Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70%linear, approx. 90% optical.Outer jacketLow-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suitthe requirements in Energy Chains ® (following DIN VDE 0282 Part 10).Colour: Yellow green (similar to RAL 6018)UL/CSA Style 1589 and 20236, 30 V, 80 °CMeasuring system cableCEI Following CEI 20-35CEFollowing 2006/95/ECDESINALead freeClean roomTypical application arean for maximum load requirementsAccording to VDW, DESINA standardisationFollowing 2002/95/EC (RoHS)According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D,tested by IPA according to standard 14644-1n almost unlimited resistance to oiln indoor and outdoor applications without direct sun radiationn especially for freely suspended and gliding travel distances up to 100 mn Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, indoor cranes, low-temperature applicationsTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF113D(for up to 10 cuts of the same type)137


CF113.DPUR10 x dPUR Measuring system cable<strong>Chainflex</strong> ® CF113.D● for maximum load requirements● PUR outer jacket● shielded● oil-resistant and coolant-resistant● notch-resistant● flame-retardant● hydrolysis-resistant and microbe-resistant● PVC-free/halogen-freeImage exemplary.Delivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF113.001.D(3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5 72 172CF113.002.D (3x(2x0,14)C+2x(0,5)C)C 10,5 74 185CF113.003.D (1) (3x(2x0,14)+2x1,0)C 8,5 55 124CF113.004.D(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 11,5 82 195CF113.005.D (4x(2x0,14)+4x0,5)C 9,5 61 144CF113.006.D(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 11,0 84 197CF113.007.D (2x2x0,34)C 6,0 29 64CF113.008.D (1) (3x(2x0,25))C 8,0 33 81CF113.009.D (4x(2x0,25)+2x0,5)C 9,5 60 137CF113.010.D (1) (4x(2x0,25)+2x1,0)C 9,5 72 159CF113.011.D (1) (4x(2x0,34)+4x0,5)C 10,5 87 199CF113.012.D (1)(3x(2x0,14)C+(3x0,14)C+6x0,14+2x0,5)C 11,5 90 220CF113.013.D (1) (3x(2x0,14)C+2x0,5)C 9,5 63 153CF113.014.D (1) (4x(2x0,25)C+2x0,5)C 11,5 86 210CF113.015.D (4x(2x0,14)+4x0,5)C 9,5 61 140CF113.016.D (1) (3x(2x0,25)C)C 9,5 59 141CF113.017.D (1) / (4)(4x(2x0,14)+(4x0,14)C+4x1,0)C 11,5 105 241CF113.018.D (1) / (4) (2x(2x0,25)+2x0,5)C 9,0 38 114CF113.019.D (1) / (4)(3x(2x0,25)C+(3x0,25)+2x1,0)C 11,5 96 225CF113.021.D (1) (3x(2x0,5+2x0,25)+(4x0,25))C 11,0 92 210NewNewClass 6.3.3(1) Delivery time upon inquiry(4) manufactured without inner jacketNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreMore types Page 140138... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.3.3Delivery programNumber of cores and conductorPart No. nominal cross section [mm 2]Price indexCore group Colour codeCF113.001.D (3x(2x0,14)C+(4x0,14)+(2x0,5))C 3x(2x0,14)C(4x0,14)(2x0,5)yellow/green, black/brown, red/orangegray, blue, white-yellow, white-blackbrown-red, brown-blueCF113.002.D(3x(2x0,14)C+2x(0,5)C)C 3x(2x0,14)C2x(0,5)Cgreen/yellow, black/brown, red/orangeblack, redCF113.003.D(3x(2x0,14)+2x1,0)C 3x(2x0,14)2x1,0white/brown, green/yellow, gray/pinkblue, redCF113.004.D (2x(2x2x0,14)+ (4x0,14)C+4x0,5)C 2x(2x2x0,14) brown/green, violet/yellow, gray/pink, red/black(4x0,14)C4x0,5yellow-black, red-black, green-black, blue-blackbrown-green, white-green, blue, whiteCF113.005.D(4x(2x0,14)+4x0,5)C 4x(2x0,14)4x0,5white/brown, green/yellow, gray/pink, blue/redblack, violet, gray-pink, red-blueCF113.006.D (3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 3x(2x0,14)C(4x0,14)(4x0,23)(2x0,5)green/yellow, brown/black, red/orangeblue, gray, white-black, white-yellowbrown-yellow, brown-gray, green-black, green-redbrown-red, brown-blueCF113.007.D (2x2x0,34) 4x0,34 white, green, brown, yellow (star-quad stranding)CF113.008.D(3x(2x0,25))C 3x(2x0,25) white/brown, green/yellow, gray/pinkCF113.009.D(4x(2x0,25)+2x0,5)C 4x(2x0,25)2x0,5brown/green, blue/violet, gray/pink, red/blackwhite, brownCF113.010.D(4x(2x0,25)+2x1,0)C 4x(2x0,25)2x1,0brown/green, blue/violet, gray/pink, red/blackwhite, brownCF113.011.D(4x(2x0,34)+4x0,5)C 4x(2x0,34)4x0,5black/brown, red/orange, yellow/green, blue/violetblue-white, black-white, red-white, yellow-whiteCF113.012.D (3x(2x0,14)C+(3x0,14)C+6x0,14+2x0,5)C 3x(2x0,14)C(3x0,14)C6x0,142x0,5green/yellow, white/gray, blue/redred, green, brownblue, gray, gray, yellow, pink, violetbrown-red, brown-blueCF113.013.D(3x(2x0,14)C+2x0,5)C 3x(2x0,14)C2x0,5white/brown, green/yellow, gray/pinkred, blueCF113.014.D(4x(2x0,25)C+2x0,5)C 4x(2x0,25)C2x0,5white/brown, green/yellow, gray/pink, blue/redblack (numeral printing 1-2)CF113.015.D(4x(2x0,14)+4x0,5)C 4x(2x0,14)4x0,5brown/green, violet/yellow, gray/pink, red/blackblue, white, brown-green, white-greenCF113.016.D(3x(2x0,25)C)C 3x(2x0,25)C white/brown, green/yellow, gray/pinkCF113.017.D (4x(2x0,14)+(4x0,14)C+4x1,0)C 4x(2x0,14)(4x0,14)C4x1,0red/black, green/brown, yellow/violet, pink/grayblue-black, red-black, yellow-black, green-blackwhite-green, brown-green, blue, whiteCF113.018.D(2x(2x0,25)+2x0,5)C 2x(2x0,25)2x0,5red/black, gray/pinkwhite, brownCF113.019.D (3x(2x0,25)C+(3x0,25)+2x1,0)C 3x(2x0,25)C(3x0,25)2x1,0brown/green, gray/pink, red/blackblue, yellow, violetwhite, brownCF113.021.D (3x(2x0,5+2x0,25)+(4x0,25))C 3x(2x0,25)3x(2x0,5)(4x0,25)white/yellow, white/gray, black/orangeblack (numeral printing 1-6)white, gray, brown, blackCF113.DPUR10 x dTel. +49-2203-96 49-0Measuring system cableFax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF113D(for up to 10 cuts of the same type)139


CF113.DPUR10 x dPUR Measuring system cable<strong>Chainflex</strong> ® CF113.D● for maximum load requirements● PUR outer jacket● shielded● oil-resistant and coolant-resistant● notch-resistant● flame-retardant● hydrolysis-resistant and microbe-resistant● PVC-free/halogen-freeDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF113.022.D (1) (5x0,5+(2x0,25))C 8,5 50 121CF113.025.D (1) (3x(2x0,14)C+(2x0,5)C)C 11,0 73 180CF113.027.D (1) (5x(2x0,14)+2x0,5)C 9,0 52 121CF113.028.D (2x(2x0,15)+(2x0,38))C 7,5 47 72CF113.032.D (1) 3x(2x0,14)C+(3x0,14)C 8,0 61 148CF113.033.D (1) 4x(2x0,14)C+2x(1,0)C 10,0 97 237CF113.034.D (1)3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C 11,5 105 199NeuNeuNeu(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreClass 6.3.3Image exemplary.140... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.3.3Delivery programPart No.Price indexNumber of cores and conductor Core group Colour codenominal cross section [mm 2 ]CF113.022.D (5x0,5+(2x0,25))C 5x0,5(2x0,25)blue, green, yellow, gray, pinkwhite, brownCF113.025.D(3x(2x0,14)C+(2x0,5)C)C 3x(2x0,14)(2x0,5)Cgreen/yellow, blue/red, gray/pinkwhite, brownCF113.027.D(5x(2x0,14)+2x0,5)C 5x(2x0,14)2x0,5green/brown, gray/yellow, white/violet, black/red, blue/pinkwhite-green, white-redCF113.028.D(2x(2x0,15)+(2x0,38))C 2x(2x0,15)(2x0,38)green/yellow, pink/bluered, blackCF113.032.D3x(2x0,14)C+(3x0,14)C 3x(2x0,14)C(3x0,14)Cyellow/black, red/black, green/blackblack, gray, pinkCF113.033.D4x(2x0,14)C+2x(1,0)C 4x(2x0,14)C2x(1,0)Cyellow/black, red/black, green/black, blue/blackwhite, brownCF113.034.D 3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C 3x(2x0,14)C(4x0,14)C2x(2x0,5)Cgreen/black, violet/black, blue/blackyellow, red-black, yellow-black, redblack/brown, black/whiteCF113.DPUR10 x dTel. +49-2203-96 49-0Measuring system cableFax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF113D(for up to 10 cuts of the same type)141


CF111.DTPE12 x dCenter elementfor high tensilestressesTPE Measuring system cable<strong>Chainflex</strong> ® CF111.D● for medium load requirements● TPE outer jacket● shielded● oil-resistant● bio-oil-resistant● flame-retardant● hydrolysis-resistant and microbe-resistantFine-wire specialconductorTemperature rangemovedTemperature rangefixedv max.unsupported-35 °C to +100 °C, minimum bending radius 12 x d-40 °C to +100 °C, minimum bending radius 6 x d2 m/sCores each strandedwith short pitcha max. 30 m/s 2Travel distance Freely suspended travel distances, Class 1UV-resistantMediumNominal voltage30 VTesting voltage500 VBending-resistantbraided copper shieldOilOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Flame-retardantAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Pressureextruded,flame-retardTPE blendSilicon-freeConductorCore insulationFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Very finely stranded special cores of particularly high-flexdesign made of bare copper wires.Mechanically high-quality PP mixture.Core strandingAccording to measuring system specification.Class 4.1.4142Image exemplary.Core identificationElement shieldIntermediate sheathOverall shieldOuter jacketAccording to measuring system specificationSchedule delivery programBending-resistant, tinned braided copper shield.Coverage approx. 55% linear, approx. 80% optical.Foil taping over the external layer.Bending-resistant, tinned braided copper shield.Coverage approx. 55% linear, approx. 80% optical.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® . Colour: Yellow green (similar to RAL 6018)... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.1.4Price indexCF111.DTPE12 x dUL/CSA Style 1589 and 21371, 30 V, 80 °CCEI Following CEI 20-35CEFollowing 2006/95/ECDESINAAccording to VDW, DESINA standardisationLead freeFollowing 2002/95/EC (RoHS).Measuring system cableClean roomAccording to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, testedby IPA according to standard 14644-1Typical application arean for medium load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications without direct sun radiationn especially for freely suspended travel distancesn machining units/machine tools, low temperature applicationsTel. +49-2203-96 49-0Fax +49-2203-96 49-222The ReadyChain ® systems from igus ® are completely pre-assembled with <strong>Chainflex</strong> ® <strong>cables</strong>, hoses, screw attachments, metal parts etc.950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF111D (for up to 10 cuts of the same type)143


CF111.DTPE12 x dTPE Measuring system cable<strong>Chainflex</strong> ® CF111.D● for high load requirements● TPE outer jacket● shielded● oil-resistant● bio-oil-resistant● flame-retardant● hydrolysis-resistant and microbe-resistantDelivery programPart No.CF111.001.DCF111.004.DNumber of cores and External Copper Weightconductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km](3x(2x0,14)C+(4x0,14)+(2x0,5))C 8,5 56 87(4x(2x0,14)+(4x0,14)C+4x0,5)C 10,5 72 113CF111.006.D(3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 10,0 69 112CF111.011.D (4x(2x0,34)+4x0,5)C 9,5 69 106CF111.015.D (4x(2x0,14)+4x0,5)C 8,0 49 76CF111.021.D (6x0,5+5x2x0,25)C 10,0 79 125CF111.022.D (5x0,5+1x2x0,25)C 8,0 49 78CF111.027.D (1) (5x(2x0,14)+2x0,5)C 9,0 54 109CF111.035.D (4x(2x0,25)C+2x(2x0,5))C 12,5 118 202(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF111.021.D – in your desired length (0,5 m steps)CF111.D <strong>Chainflex</strong> ® series .001 Code Measuring systemPlease use www.chainflex.eu/en/CF111D for your online order.Image exemplary.Delivery time 24h or today** Delivery time means time until shipping of goodsClass 4.1.4144... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.1.4Price indexCF111.DTPE12 x dPart No. Number of cores and conductor Core group Colour codenominal cross section [mm 2 ]CF111.001.D (3x(2x0,14)C+(4x0,14)+(2x0,5))C 3x(2x0,14)C yellow/green, black/brown, red/orange4x0,142x0,5gray, blue, white-yellow, white-blackbrown-red, brown-blueCF111.004.D (4x(2x0,14)+(4x0,14)C+4x0,5)C 4x(2x0,14)(4x0,14)C4x0,5brown/green, violet/yellow, gray/pink, red/blackyellow-black, red-black, green-black, blue-blackbrown-green, white-green, blue, whiteCF111.006.D (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 3x(2x0,14)C green/yellow, black/brown, red/orange4x0,144x0,232x0,5gray, blue, white-yellow, white-blackbrown-yellow, brown-gray, green-black, green-redbrown-red, brown-blueCF111.011.D(4x(2x0,34)+4x0,5)C 4x(2x0,34)4x0,5black/brown, red/orange, yellow/green, blue/violetblue-white, black-white, red-white, yellow-whiteCF111.015.D(4x(2x0,14)+4x0,5)C 4x(2x0,14)4x0,5brown/green, violet/yellow, gray/pink, red/blackblue, white, brown-green, white-greenCF111.021.D(6x0,5+5x2x0,25)C (3x0,5)(3x0,5)(5x2x0,25)black (numeral printing 1-3)red (numeral printing 1-3)yellow/white, gray/white, black/orange, white/brown, black/grayCF111.022.D(5x0,5+1x2x0,25)C (5x0,5)(2x0,25)blue, green, yellow, gray, pinkwhite, brownCF111.027.D(5x(2x0,14)+ 5x(2x0,14)2x0,5)C (2x0,5)green/brown, gray/yellow, white/violet, black/red, blue/pinkwhite-green, white-redCF111.035.D(4x(2x0,25)C+ 4x(2x0,25)C white/brown, green/yellow, gray/pink, blue/red2x(2x0,5))C 2x(2x0,5) black (numeral printing 1-4)Measuring system cableTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF111D (for up to 10 cuts of the same type)145


CF11.DTPE10 x dEspecially bendingresistantfine-wirestranded conductorTPE Measuring system cable<strong>Chainflex</strong> ® CF11.D● for maximum load requirements● TPE outer jacket● shielded● twisted-pair● oil- and bio-oil-resistant● PVC-free/halogen-free● hydrolysis-resistant and microbe-resistantExtrem Highly flexiblebraided copper shieldTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +100 °C, minimum bending radius 10 x d-40 °C to +100 °C, minimum bending radius 5 x d10 m/s, 6 m/sCenter elementfor high tensilestressesa max. 100 m/s 2Travel distance Freely suspended and gliding travel distances up to 400 m,Class 4Cores each stranded inespecially short pitchUV-resistantNominal voltageMedium30 VGusset-filledextrudedHighly flexible braidedcopper shieldTesting voltageOilSilicon-free500 VOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Pressureextruded,halogen-freeTPE blendConductorCore insulationFine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Mechanically high-quality PP mixture.Core strandingAccording to measuring system specification.Class 6.4.4146Image exemplary.Core identificationElement shieldAccording to measuring system specificationSchedule delivery programExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Inner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Overall shieldOuter jacketExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® . Colour: Yellow green (similar to RAL 6018)... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF11.DTPE10 x dCEDESINALead freeClean roomFollowing 2006/95/ECAccording to VDW, DESINA standardisationFollowing 2002/95/EC (RoHS).According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, testedby IPA according to standard 14644-1Measuring system cableTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications without direct sun radiationn especially for freely suspended and gliding travel distances up to 400 mn storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, outdoor cranes, low-temperature applicationsTel. +49-2203-96 49-0Fax +49-2203-96 49-222Pre-assembled igus ® energy supply systems for machine tool manufacture. E-Chain ® : System E4/4950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF11D(for up to 10 cuts of the same type)147


CF11.DTPE10 x dTPE Measuring system cable<strong>Chainflex</strong> ® CF11.D● for maximum load requirements● TPE outer jacket● shielded● twisted-pair● oil- and bio-oil-resistant● PVC-free/halogen-free● hydrolysis-resistant and microbe-resistantImage exemplary.Delivery program*Part No.CF11.001.DNumber of cores and External Copper Weightconductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km](3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5 72 168CF11.002.D (3x(2x0,14)C+2x(0,5)C)C 10,5 74 180CF11.003.D (3x(2x0,14)+2x1,0)C 8,5 55 118CF11.004.D(2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 11,5 81 188CF11.005.D (4x(2x0,14)+4x0,5)C 9,5 61 137CF11.006.D (4)(3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 11,0 84 193CF11.007.D (2x2x0,34)C 6,0 29 62CF11.008.D (3x(2x0,25))C 7,5 33 77CF11.009.D (4x(2x0,25)+2x0,5)C 9,5 60 131CF11.010.D (4x(2x0,25)+2x1,0)C 9,5 72 153CF11.011.D (4x(2x0,34)+4x0,5)C 10,5 87 192CF11.012.D(3x(2x0,14)C+(3x0,14)C+6x0,14+2x0,5)C 11,5 90 213CF11.013.D (3x(2x0,14)C+2x0,5)C 9,5 63 145CF11.014.D (1) (4x(2x0,25)C+2x0,5)C 11,5 86 203CF11.015.D (4x(2x0,14)+4x0,5)C 9,5 61 133CF11.016.D (1) (3x(2x0,25)C)C 9,5 59 138CF11.017.D (4)(4x(2x0,14)+(4x0,14)C+4x1,0)C 11,5 105 234CF11.018.D (4) (2x(2x0,25)+2x0,5)C 7,0 36 72CF11.019.D (4)(3x(2x0,25)C+(3x0,25)+2x1,0)C 11,5 96 218(1) Delivery time upon inquiry(4) manufactured without inner jacketNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreNewNewClass 6.4.4More types Page 150148... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF11.DTPE10 x dPart No. Number of cores and conductornominal cross section [mm 2 ]Core group Colour codeCF11.001.D (3x(2x0,14)C+(4x0,14)+(2x0,5))C 3x(2x0,14)C(4x0,14)(2x0,5)yellow/green, black/brown, red/orangegray, blue, white-yellow, white-blackbrown-red, brown-blueCF11.002.D(3x(2x0,14)C+2x(0,5)C)C 3x(2x0,14)C2x(0,5)Cgreen/yellow, black/brown, red/orangeblack, redCF11.003.D(3x(2x0,14)+2x1,0)C 3x(2x0,14)2x1,0white/brown, green/yellow, gray/pinkblue, redCF11.004.D (2x(2x2x0,14)+ (4x0,14)C+4x0,5)C 2x(2x2x0,14)(4x0,14)C4x0,5brown/green, violet/yellow, gray/pink, red/blackyellow-black, red-black, green-black, blue-blackbrown-green, white-green, blue, whiteCF11.005.D(4x(2x0,14)+4x0,5)C 4x(2x0,14)4x0,5white/brown, green/yellow, gray/pink, blue/redblack, violet, gray-pink, red-blueCF11.006.D (3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 3x(2x0,14)C(4x0,14)(4x0,23)(2x0,5)green/yellow, brown/black, red/orangeblue, gray, white-black, white-yellowbrown-yellow, brown-gray, green-black, green-redbrown-red, brown-blueCF11.007.D (2x(2x0,34)C 4x0,34 white, green, brown, yellow (star-quad stranding)CF11.008.D(3x(2x0,25))C 3x(2x0,25) white/brown, green/yellow, gray/pinkCF11.009.D(4x(2x0,25)+2x0,5)C 4x(2x0,25)2x0,5brown/green, blue/violet, gray/pink, red/blackwhite, brownCF11.010.D(4x(2x0,25)+2x1,0)C 4x(2x0,25)2x1,0brown/green, blue/violet, gray/pink, red/blackwhite, brownCF11.011.D(4x(2x0,34)+4x0,5)C 4x(2x0,34)4x0,5black/brown, red/orange, yellow/green, blue/violetblue-white, black-white, red-white, yellow-whiteCF11.012.D (3x(2x0,14)C+(3x0,14)C+6x0,14+2x0,5)C 3x(2x0,14)C(3x0,14)C6x0,142x0,5green/yellow, white/gray, blue/redred, green, brownblue, gray, gray, yellow, pink, violetbrown-red, brown-blueCF11.013.D(3x(2x0,14)C+2x0,5)C 3x(2x0,14)C2x0,5white/brown, green/yellow, gray/pinkred, blueCF11.014.D(4x(2x0,25)C+2x0,5)C 4x(2x0,25)C2x0,5white/brown, green/yellow, gray/pink, blue/redblack (numeral printing 1-2)CF11.015.D(4x(2x0,14)+4x0,5)C 4x(2x0,14)4x0,5brown/green, violet/yellow, gray/pink, red/blackblue, white, brown-green, white-greenCF11.016.D(3x(2x0,25)C)C 3x(2x0,25)C white/brown, green/yellow, gray/pinkCF11.017.D (4x(2x0,14)+(4x0,14)C+4x1,0)C 4x(2x0,14)(4x0,14)C4x1,0red/black, green/brown, yellow/violet, pink/grayblue-black, red-black, yellow-black, green-blackwhite-green, brown-green, blue, whiteCF11.018.D(2x(2x0,25)+2x0,5)C 2x(2x0,25)2x0,5red/black, gray/pinkwhite, brownCF11.019.D (3x(2x0,25)C+(3x0,25)+2x1,0)C 3x(2x0,25)C(3x0,25)2x1,0brown/green, gray/pink, red/blackblue, yellow, violetwhite, brownMeasuring system cableTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF11D(for up to 10 cuts of the same type)149


CF11.DTPE10 x dTPE Measuring system cable<strong>Chainflex</strong> ® CF11.D● for maximum load requirements● TPE outer jacket● shielded● twisted-pair● oil- and bio-oil-resistant● PVC-free/halogen-free● hydrolysis-resistant and microbe-resistantDelivery program*Number of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF11.021.D (3x(2x0,5+2x0,25)+(4x0,25))C 11,0 92 203CF11.022.D (5x0,5+(2x0,25))C 8,5 50 115CF11.025.D (3x(2x0,14)C+(2x0,5)C)C 10,5 73 174CF11.027.D (5x(2x0,14)+2x0,5)C 9,0 52 115CF11.032.D (1) 3x(2x0,14)C+(3x0,14)C 8,0 61 144CF11.033.D (1) 4x(2x0,14)C+2x(1,0)C 10,0 97 230CF11.034.D (1)3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C 11,5 105 177NewNewNew(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreClass 6.4.4Image exemplary.150... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF11.DTPE10 x dPart No. Number of cores and conduc-Core grouptor nominal cross section [mm 2 ]CF11.021.D (3x(2x0,5+2x0,25)+(4x0,25))C 3x(2x0,25)3x(2x0,5)(4x0,25)CF11.022.D (5x0,5+(2x0,25))C 5x0,5(2x0,25)CF11.025.D(3x(2x0,14)C+(2x0,5)C)C 3x(2x0,14)(2x0,5)CF11.027.D(5x(2x0,14)+2x0,5)C 5x(2x0,14)2x0,5CF11.032.D3x(2x0,14)C+(3x0,14)C 3x(2x0,14)C(3x0,14)CCF11.033.D4x(2x0,14)C+2x(1,0)C 4x(2x0,14)C2x(1,0)CCF11.034.D 3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C 3x(2x0,14)C(4x0,14)C2x(2x0,5)CColour codewhite/yellow, white/gray, black/orangeblack (numeral printing 1-6)white, gray, brown, blackblue, green, yellow, gray, pinkwhite, browngreen/yellow, blue/red, gray/pinkwhite, browngreen/brown, gray/yellow, white/violet, black/red, blue/pinkwhite-green, white-redyellow/black, red/black, green/blackblack, gray, pinkyellow/black, red/black, green/black, blue/blackwhite, browngreen/black, violet/black, blue/blackyellow, red-black, yellow-black, redblack/brown, black/whiteMeasuring system cableTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF11D(for up to 10 cuts of the same type)151


CF Koax 1TPE10 x dEspecially bendingresistantspecialconductorHighly flexible braidedcopper shieldTPE Koax cable<strong>Chainflex</strong> ® CF Koax 1● 75 Ω koax cable for maximum load requirements● TPE outer jacket● oil-resistant● bio-oil-resistant● UV-resistant● hydrolysis-resistant and microbe-resistantTemperature rangemoved-35 °C to +100 °C, minimum bending radius 10 x dTemperature rangefixed-40 °C to +100 °C, minimum bending radius 7,5 x dv max.unsupported/gliding 10 m/s, 5 m/sa max. 100 m/s 2Travel distance Freely suspended and gliding travel distances up to 400 m,Class 4UV-resistantHighNominal voltage 300/300 V (following DIN VDE 0245).Testing voltage1500 VElements strandedwith short pitch,FEP special insulationOilSilicon-freeConductorOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Multi-wire; adapted in single-wire diameter and pitch length tosuit the requirements in Energy Chains ® .Core insulationSpecial FEP-isolating mixture.Gusset-filledextruded,halogen-freeTPE mixtureCore strandingCore identificationElement shieldCores stranded in one layer with especially short pitch length.Schedule delivery programExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Element jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Class 6.4.4Outer jacketCELead freeLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® .Colour: Steel blue (similar to RAL 5011)Following 2006/95/ECFollowing 2002/95/EC (RoHS).152Image exemplary.Clean roomAccording to ISO Class 1. Outer jacket material complies withCF9.15.07, tested by IPA according to standard 14644-1... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF Koax 1TPE10 x dInfoThe coax elements used in <strong>cables</strong> of the CF Koax1 series are comparable with aHF75-0.3/1.6 according to MIL-C-17/94-RG179 and thus fit in an RG179 plug!Typical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 mn storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, outdoor cranes, low-temperature applicationsKoax cableDelivery programPart No.Number of cores ExternaldiameterCopperindexWeight[kg/km]approx. [mm] [kg/km]CFKoax 1.01 1 coaxial element 4,5 9 25CFKoax 1.05 5 coaxial elements 10,0 47 135Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.Delivery programPart No.Characteris tic waveimpedance approx. [Ω]Number of cores Colour codeCF Koax 1.01 751 coaxial element blackCF Koax 1.05 755 coaxial elements red, green, blue, white, blackTel. +49-2203-96 49-0Fax +49-2203-96 49-222Order example: CFKoax1.01 – in your desired length (0,5 m steps)CF Koax1 <strong>Chainflex</strong> ® series .01 Number of coaxial elementsPlease use www.chainflex.eu/en/CFKOAX1 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsKoax <strong>cables</strong> and other <strong>Chainflex</strong> ® <strong>cables</strong> in platform technology. E-Chain ® : System E4/4950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFKOAX1 (for up to 10 cuts of the same type)153


ibre optic <strong>cables</strong>


<strong>Chainflex</strong> ®cableJacketShield<strong>Chainflex</strong> ®Minimum bendingradius, moved[factor x d]Temperaturemovedfrom/to [°C]typesApprovals andstandardsOil-resistantTorsion resistantv max. [m/s]unsupportedv max. [m/s]glidinga max. [m/s 2 ]PageFibre optic <strong>cables</strong> (FOC)*CFLK*** PUR 12,5 -20/ +70 ✔ 10 5 20 158CFLG.2H** PUR 12,5 -20/ +60 ✔ 10 6 20 160CFLG.LB** TPE 5 -40/ +60 ✔ 10 6 20 162CFLG. G** TPE 15 -40/ +60 ✔ 10 6 20 164* CFROBOT5, torsionable fibre optic <strong>cables</strong> Page 220** Multimode/gradient fibres*** POF-Fiber/plastic FOC155


InfoThe safest and often cheapest way to transfer data to machinesand plant.Fault-free communication between all systems in machinesand plant that is becoming more and more complex allthe time should be a matter of course these days.However, many plant manufacturers or operators havemajor EMC problems that occur sporadically or even onlyyears later.These problems are often based on conventional bus<strong>cables</strong> that either have insufficient or unreliable shielding.Alongside igus ® <strong>Chainflex</strong> ® bus <strong>cables</strong> that already preventthese problems to a large extent, <strong>Chainflex</strong> ® glassfibre optic <strong>cables</strong> provide further advantages for evengreater data safety.Fibre optic <strong>cables</strong> (FOC) do not require a braided shieldingthat is susceptible to mechanical damage as EMCprotection, and are insensitive to EMC on account of theirvery nature, since industrial conventional interference fieldsdo not have any effect on light signals.In addition, fibre optic <strong>cables</strong> can be used independentlyof the system, since a special bus cable is not requiredfor every bus system, rather one FOC type can usually beused to operate any bus system providing the bus systemmanufacturer provides respective FOC converters.Important fibre types:n Multi-mode fibres50/125 µm62,5/125 µmThe ideal fibre for large data volumes and longer transmissionlengths in the field of automation. On accountof the very low output attenuation (0.8-3 db/km perfibre and light wave length) of these fibre types, transmissionlengths of several hundred metres can be realisedquite easily.n POF (Plastic fibres)980/1000 µmThe ideal and low-cost fibre for short transmissionpaths. On account of the high output attenuation ofthe fibre type of 160-230 dB/km, lengths over 15 mmmust be avoided in permanent-motion energy chains ® .n PCF (Polymer Cladded Fibre)200/230 µmThe ideal compromise for POF fibre. This plastic-coatedquartz glass fibre is a viable alternative for many terminaldevices that have been designed for POF.This means greater transmission lengths (100 m andmore) are possible without the original POF terminaldevices having to be replaced.The large number of fibre optic <strong>cables</strong> in industrial datatransmission is also much more manageable than thelarge number of different field or high-speed buses whichrequire a separate cable for each bus.Thus the following fibre types can be used for industrialdata communication, completely independently of thetype of field bus used. The fibre type and number dependsonly on which converters are used and which fibre typethe respective manufacturer prescribes. The fibres aredefined on the basis of diameter and result in a clear andlimited choice.156... no minimum order quantity


Info<strong>Chainflex</strong> ® FOC offer the operator the following advantages:1. Greater data security thanks ton FOC-typical better transmission characteristicsn Greater possible transmission lengths of several 100 mn Greater possible data volumes thanks to lower attenuationvaluesn Maximum EMC protection for the data transmittedn Future-proof installation (no cable replacement withnew bus systems)2. Greater mechanical protection throughn The FOC designed for permanent mechanical movementn The igus ® -typical highly abrasion-proof and chemicalresistant sheathing materialsn The special <strong>Chainflex</strong> ® design concept (tested at 30 millioncycles without a significant increase in attenuation)3. Future-oriented cost reduction throughn Bus-independent bus cable wiringn Longer service life in E-Chains ®n Extendable without transmission limits<strong>Chainflex</strong> ®Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Test data Page 36950 types from stock no cutting costs ...(for up to 10 cuts of the same type)157


CFLKPUR12,5 x dPUR Fibre optic cable (FOC)<strong>Chainflex</strong> ® CFLK● POF fibres for high load requirementsand interference-free transmission● PUR outer jacket● oil-resistant and coolant-resistantPolymer fibres(POF)Temperature rangemoved-20 °C to +70 °C, minimum bending radius 12,5 x dTemperature rangefixed-25 °C to +70 °C, minimum bending radius 7,5 x dv max.unsupported/gliding 10 m/s, 5 m/sa max. 20 m/s 2Travel distance Freely suspended and gliding travel distances up to 15 m,Class 1UV-resistantMediumExtruded inner jacketOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Glass-fibre yarn wrapFibre optic cableCore stranding980/1000 µm fibre with PE isolation.POF fibre with stranded high-tensile plastic reinforcement.Core identificationBlack core.Highly abrasionresistantPURjacket blendOuter jacketCELow-adhesion mixture on the basis of PUR, adapted to suitthe requirements in Energy Chains ® (following DIN VDE 0282Part 10). Colour: Red lilac (similar to RAL 4001)Following 2006/95/ECLead freeFollowing 2002/95/EC (RoHS).Class 5.1.3158Image exemplary.Typical application arean for high load requirementsn maximum EMC protectionn almost unlimited resistance to oiln preferably indoor applicationsn especially for freely suspended and gliding travel distances up to 15 mn wood/stone processing, packaging industry, supply system, handling, adjusting equipment... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.1.3Price indexCFLKPUR12,5 x dDelivery programPart No.Number of fibres FibrediameterExternaldiameterWeight[kg/km]approx. [µm] approx. [mm]CFLK.L1.01 1 980/1000 6,0 25Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.Delivery programPart No.Bandwidthwith 650 nm[MHz x km]Attenuationwith 650 nm[dB/km]ColourcodeCFLK.L1.01 40 200 blackFibre optic cableOrder example: CFLK.L1.01 – in your desired length (0,5 m steps)CFLK <strong>Chainflex</strong> ® series .L1 Type of fibres .01 Number of coresPlease use www.chainflex.eu/en/CFLK for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTel. +49-2203-96 49-0Fax +49-2203-96 49-222Woodworkingmachines with E-Chains ® and <strong>Chainflex</strong> ® <strong>cables</strong>950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFLK(for up to 10 cuts of the same type)159


CFLG.2HPUR12,5 x dFOC-fibresPUR Fibre optic cable (FOC)<strong>Chainflex</strong> ® CFLG.2H● for high load requirements● PUR outer jacket● metal-free● oil-resistant and coolant-resistant● UV-resistantPlastic coveredspecial fibreTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-20 °C to +60 °C, minimum bending radius 12,5 x d-25 °C to +60 °C, minimum bending radius 7,5 x d10 m/s, 6 m/sa max. 20 m/s 2Gel-filled, armoredhollow coreTravel distance Freely suspended and gliding travel distances up to 100 m,Class 3UV-resistantHighOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3Offshore MUD-resistant following NEK 606Armored hollow coreswith optimized pitchlength stranded arounda strain relief elementSilicon-freeFibre optic cableCore strandingCore identificationFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).50/125 µm, 62,5/125 µm, 200/230 µm fibres in gel-filledhollow cores.Hollow cores with integrated FOC-fibres stranded with twostrain relief elements.Cores black with white numerals.Gusset-filledextrudedPUR mixtureOuter jacketCELead freeLow-adhesion mixture on the basis of PUR, adapted to suitthe requirements in Energy Chains ® (following DIN VDE 0282Part 10). Colour: Jet black (similar to RAL 9005)Following 2006/95/ECFollowing 2002/95/EC (RoHS).Class 6.3.3Typical application arean for high load requirementsn maximum EMC protection, with high transmission qualities in terms of glass-specific requirementsn almost unlimited resistance to oiln indoor and outdoor applicationsn only for freely suspended and gliding travel distances up to 100 mn Storage and retrieval units for high-bay warehouses, machining units/packaging machines,quick handling, cranes, refrigerating sector160Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.3.3Price indexCFLG.2HPUR12,5 x dDelivery programPart No.Number of fibres Fibrediameterapprox. [µm]Externaldiameterapprox. [mm]Weight[kg/km]CFLG.2HG.MF.62,5/125 2 62,5/125 9,0 85CFLG.2HG.MF.50/125 2 50/125 9,0 85CFLG.2HS.MF.200/230 2 200/230 9,0 85Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.Fibre optic cableDelivery programBandwidth Attenuation Bandwidth AttenuationPart No.with 850 nm with 850 nm with 1300 nm with 1300 nm[MHz x km] [dB/km] [MHz x km] [dB/km]CFLG.2HG.MF.62,5/125 160 - 200 3,2 200 - 500 0,9CFLG.2HG.MF.50/125 200 - 600 2,5 - 3,5 600 - 1200 0,7 - 1,5CFLG.2HS.MF.200/230 20 6,0 – –Colour codeblack with white numbersblack with white numbersblack with white numbersOrder example: CFLG.2HG.MF.62,5/125 – in your desired length (0,5 m steps)CFLG.2H <strong>Chainflex</strong> ® series .MF Metal-free .62,5/125 Type of fibresPlease use www.chainflex.eu/en/CFLG2HG for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTest data Page 36Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Metal-free fibre optic <strong>cables</strong> for fast handling applications. E-Chain ® : System E2/000950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFLG2HG (for up to 10 cuts of the same type)161


CFLG.LBTPE5 x dFOC cores with hightensilearamide fibresReinforced opticalfibres twisted withan optimized pitchTPE Fibre optic cable (FOC)<strong>Chainflex</strong> ® CFLG.LB● Gradient glass-fiber cable for maximum load requirements● TPE outer jacket● metal-free● oil-resistant● low-temperature-flexible up to -40 °C● UV-resistantTemperature range -40 °C to +60 °C, minimum bending radius 5 x dmovedTemperature range -40 °C to +60 °C, minimum bending radius 5 x dfixedv max.10 m/s, 6 m/sunsupported/glidinga max. 20 m/s 2Travel distanceUV-resistantFreely suspended and gliding travel distances up to 100 mand more, Class 3HighAramid braid fortorsion protectionOilSilicon-freeFibre optic cableCore strandingCore identificationOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 192).50/125 µm, 62.5/125 µm special fixed wire elements witharamide strain relief.FOC cores stranded with high-tensile aramide dampers withespecially short pitch length.Cores blue with white numerals.Overall shieldExtremely bending-resistant aramid braid for torsion protection.Pressure extruded,halogen-freeTPE blendOuter jacketCELow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® . Colour: Jet black (similar to RAL 9005)Following 2006/95/ECLead freeFollowing 2002/95/EC (RoHS).Class 7.3.4162Image exemplary.Typical application arean for maximum load requirements at 5 x dn Maximum EMC protection, with high transmission qualities in terms of glass-specific requirementsn almost unlimited resistance to oil, also with bio-oilsn Indoor and outdoor applicationsn especially for freely suspended and gliding travel distances up to 100 m and moren Storage and retrieval units for high-bay warehouses, machining units/packaging machines,quick handling, semiconductor insertion, refrigerating sector... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.3.4Price indexCFLG.LBTPE5 x dDelivery programPart No.Number of fibres Fibrediameterapprox. [µm]Externaldiameterapprox. [mm]Weight[kg/km]CFLG.2LB.62,5/125 2 62,5/125 8,5 47CFLG.2LB.50/125 2 50/125 8,5 47Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.Fibre optic cableDelivery programPart No.Bandwidthwith 850 nm[MHz x km]Attenuationwith 850 nm[dB/km]Bandwidthwith 1300 nm[MHz x km]Attenuationwith 1300 nm[dB/km]Colour codeCFLG.2LB.62,5/125 160 - 200 3,2 200 - 500 0,9 blue with white numbersCFLG.2LB.50/125 200 - 600 2,5 - 3,5 600 - 1200 0,7 - 1,5 blue with white numbersOrder example: CFLG.2LB.50/125 – in your desired length (0,5 m steps)CFLG.2LB <strong>Chainflex</strong> ® series .50/125 Type of fibresPlease use www.chainflex.eu/en/CFLG2LB for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFLGLB(for up to 10 cuts of the same type)163


CFLG. GTPE15 x dTPE Fibre optic cable (FOC)<strong>Chainflex</strong> ® CFLG.G● Gradient glass-fiber cable for maximum load requirements● TPE outer jacket● halogen-free● low-temperature-flexible up to -40 °C● hydrolysis-resistant and microbe-resistantGradient fibresTemperature rangemoved-40 °C to +60 °C, minimum bending radius 15 x dTemperature rangefixed-40 °C to +60 °C, minimum bending radius 8.5 x dv max.unsupported/gliding 10 m/s, 6 m/sa max. 20 m/s 2Gel-filledfibre sheathTravel distanceUV-resistantFreely suspended and gliding travel distances up to 500 mand more, Class 4HighStrandedGRP rodsOilSilicon-freeOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Fibre optic cable50/125 µm, 62.5/125 µm fibres in gel-filled hollow cores.Highly abrasionresistantPUR blendwith integrated torsionprotection braidCore strandingCore identificationOuter jacketStranded GRP rods with integrated torsion protection braid inthe outer jacket over gel-filled fiber sheath..Schedule delivery programLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® . Colour: Jet black (similar to RAL 9005)CEFollowing 2006/95/ECClass 7.4.4164Image exemplary.Lead freeTypical application arean for maximum load requirementsFollowing 2002/95/EC (RoHS).n maximum EMC protection, with high transmission qualities in terms of glass-specific requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applicationsn only for freely suspended and gliding travel distances up to 500 m and moren outdoor ship to shore, crane applications, conveyer technology... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.4.4Price indexCFLG. GTPE15 x dDelivery programPart No.Number of fibresFibrediameterapprox. [µm]Externaldiameterapprox. [mm]CFLG.6G.62,5/125.TC 6 62,5/125 11,5 110CFLG.12G.62,5/125.TC 12 62,5/125 11,5 110CFLG.6G.50/125.TC 6 50/125 11,5 110CFLG.12G.50/125.TC 12 50/125 11,5 110Other number of fibers upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.Weight[kg/km]Fibre optic cableDelivery programBandwidth Attenuation Bandwidth AttenuationPart No.with 850 nm with 850 nm with 1300 nm with 1300 nm[MHz x km] [dB/km] [MHz x km] [dB/km]CFLG.6G.62,5/125.TC 160 - 200 3,2 200 - 500 0,9CFLG.12G.62,5/125.TC 160 - 200 3,2 200 - 500 0,9CFLG.6G.50/125.TC 200 - 600 2,5 - 3,5 600 - 1200 0,7 - 1,5CFLG.12G.50/125.TC 200 - 600 2,5 - 3,5 600 - 1200 0,7 - 1,5Colour codeecru, yellow, green, red, violet,blueecru, yellow, green, red, violet,blue, lightblue, gray, brown, black,orange, pinkecru, yellow, green, red, violet,blueecru, yellow, green, red, violet,blue, lightblue, gray, brown, black,orange, pinkTel. +49-2203-96 49-0Fax +49-2203-96 49-222Order example: CFLG.6G.62,5/125.TC – in your desired length (0,5 m steps)CFLG.G <strong>Chainflex</strong> ® series .6G Number of cores .62,5/125 Type of fibres .TC Special identificationPlease use www.chainflex.eu/en/CFLGGT for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTest data Page 40igus ® fibre optic <strong>cables</strong> with 441 m travel. E-Chain ® : System E4/4950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFLGGT (for up to 10 cuts of the same type)165


166ervo <strong>cables</strong>


<strong>Chainflex</strong> ®cableJacketShield<strong>Chainflex</strong> ®Minimum bendingradius, moved[factor x d]Temperaturemovedfrom/to [°C]typesApprovals andstandardsOil-resistantTorsion resistantv max. [m/s]unsupportedv max. [m/s]glidinga max. [m/s 2 ]PageServo <strong>cables</strong>CF210.UL PVC ✔ 10 -5/ +70 ✔ 10 50 168CF21.UL PVC ✔ 7,5 -5/ +70 ✔ 10 5 80 170CF270.UL.D PUR ✔ 10 -20/ +80 ✔ 10 50 174CF27.D PUR ✔ 7,5 -20/ +80 ✔ 10 5 80 178167


CF210.ULPVC10 x dBending-resistantconductorExtremely highlyflexible braided-paircopper shieldPVC Servo cable<strong>Chainflex</strong> ® CF210.UL● for medium load requirements● PVC outer jacket● shielded● oil-resistant● flame-retardantTemperature range -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2,moved+5 °C to +70 °C for use in Energy Chains ® with > 50.000 cycles.Minimum bending radius 10 x dTemperature range -20 °C to +70 °C, minimum bending radius 5 x dfixedv max.10 m/sunsupporteda max. 50 m/s 2Travel distance Freely suspended travel distances, Class 1UV-resistantMediumEnergy conductorwith signal pairelements strandedtogether withelements for hightensile stressesNominal voltage 600/1000 V (following DIN VDE 0250).Testing voltage 4000 V (following DIN VDE 0281-2).Oil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1),Class 2.Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Bending-resistantbraided copper shieldPressure extruded,oil-resistentPVC blendClass 4.1.2168Image exemplary.Silicon-freeConductorCore insulationCore strandingCore identificationElement shieldIntermediate jacketFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 192).Fine-wire stranded conductor in bending-resistant versionconsisting of bare copper wires (following EN 60228).Mechanically high-quality, especially low-capacitancePE mixture.Energy conductor with signal pair elements stranded togetherwith elements for high tensile stresses.Energy conductor: cores black with white numerals, onecore green-yellow.1. core: U / L1 / C / L+2. core: V / L23. core: W / L3 / D / L-1 signal pair: cores black with white numerals.1. control core: 4 2. control core: 52 signal pairs: cores black with white numerals.1. control core: 5 2. control core: 63. control core: 7 4. control core: 8Star-quad: yellow, black, red, whiteBending-resistant, tinned braided copper shield.Coverage approx. 55% linear, approx. 80% optical.Foil taping over the external layer.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.1.2Price indexOverall shield Bending-resistant, tinned braided copper shield.Coverage approx. 55% linear, approx. 80% optical.Outer jacketLow-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirementsin Energy Chains ® (following DIN VDE 0281 Part 13).Colour: Pastel orange (similar to RAL 2003)UL Style 10989 and 2570, 1000 V, 80 °CCEI Following CEI 20-35CF210.ULPVC10 x dServo cableCEFollowing 2006/95/ECLead freeFollowing 2002/95/EC (RoHS)Clean roomAccording to ISO Class 2. Outer jacket material complies with CF5.10.07, tested byIPA according to standard 14644-1Typical application arean for medium load requirementsn light oil influencen preferably indoor applications, but also outdoor ones at temperatures > 5 °Cn especially for freely suspended travel distancesn Wood/stone processing, packaging industry, supply system, handling, adjusting equipmentDelivery programPart No.1 control pair shieldedCF210.UL.15.15.02.01 (4 G 1,5+(2x1,5)C)C 12,0 149 250CF210.UL.25.15.02.01 (4 G 2,5+(2x1,5)C)C 13,5 203 320CF210.UL.40.15.02.01 (4 G 4,0+(2x1,5)C)C 15,0 272 412CF210.UL.60.15.02.01 (1) (4 G 6,0+(2x1,5)C)C 16,5 364 5212 control pairs shieldedNumber of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]CF210.UL.15.07.02.02 (4 G 1,5+2x(2x0,75)C)C 13,5 169 290CF210.UL.25.15.02.02 (4 G 2,5+2x(2x1,5)C)C 15,5 260 408CF210.UL.40.15.02.02 (4 G 4,0+2x(2x1,5)C)C 17,0 330 506CF210.UL.60.15.02.02 (1) (4 G 6,0+2x(2x1,5)C)C 18,5 425 633Tel. +49-2203-96 49-0Fax +49-2203-96 49-222(1) Delivery time upon inquiry.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF210.25.15.02.01.UL – in your desired length (0,5 m steps)CF210.UL <strong>Chainflex</strong> ® series .25 Code nominal cross section .15 Code nominal cross section signal pairs.02 Identification pairs .01 Number of pairsPlease use www.chainflex.eu/en/210.UL for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF210UL(for up to 10 cuts of the same type)169


CF21.ULPVC7,5 x dHighly flexiblespecial conductorPVC Servo cable<strong>Chainflex</strong> ® CF21.UL● for high load requirements● PVC outer jacket● shielded● oil-resistant● flame-retardantEnergy conductorwith signal pairelements strandedaround high-tensilecenter cordTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-5 °C to +70 °C, minimum bending radius 7,5 x d-20 °C to +70 °C, minimum bending radius 4 x d10 m/s, 5 m/sa max. 80 m/s 2Extremely highlyflexible braided-paircopper shieldTravel distance Freely suspended and gliding travel distances up to 100 m,Class 3UV-resistantMediumNominal voltage 600/1000 V (following DIN VDE 0250).Gusset-filled,pressure extrudedTesting voltage 4000 V (following DIN VDE 0281-2).Highly flexiblebraided coppershieldOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1),Class 2Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Pressureextruded,oil-proof PVCsheath blendClass 5.3.2Silicon-freeConductorCore insulationCore strandingCore identificationFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Mechanically high-quality, especially low-capacitance TPEmixture.Energy conductor with signal pair elements stranded aroundhigh-tensile center cord.Energy conductor: cores black with white numerals, onecore green/yellow.1. core: U / L1 / C / L+2. core: V / L23. core: W / L3 / D / L-1 control pair: cores black with white numerals.1. control pair: 4 2. control pair: 52 control pairs: cores black with white numerals.1. control pair: 5 2. control pair: 63. control pair: 7 4. control pair: 8170Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.2Price indexCF21.ULPVC7,5 x dElement shieldExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Inner jacket PVC mixture adapted to suit the requirements in Energy Chains ® .Overall shield Extremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Outer jacketLow-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirementsin Energy Chains ® (following DIN VDE 0281 Part 13).Colour: Moss green (similar to RAL 6005)Servo cableUL/CSA Style 10492 and 2570, 1000 V, 80 °CCEI Following CEI 20-35CELead freeClean roomTypical application arean for high load requirementsFollowing 2006/95/ECFollowing 2002/95/EC (RoHS)According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested byIPA according to standard 14644-1n light oil influencen preferably indoor applications, but also outdoor ones at temperatures > 5 °Cn especially for freely suspended and gliding travel distances up to 100 mn storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranesTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF21UL (for up to 10 cuts of the same type)171


CF21.ULPVC7,5 x dPVC Servo cable<strong>Chainflex</strong> ® CF21.UL● for high load requirements● PVC outer jacket● shielded● oil-resistant● flame-retardantImage exemplary.Delivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]1 control pair shieldedCF21.07.05.02.01.UL (4 G 0,75+(2x0,5)C)C 11,0 95 172 7,27CF21.15.10.02.01.UL (11) (4 G 1,5+(2x1,0)C)C 12,5 125 250 8,42CF21.15.15.02.01.UL (4 G 1,5+(2x1,5)C)C 13,0 140 280 8,42CF21.25.10.02.01.UL (11) (4 G 2,5+(2x1,0)C)C 13,5 177 300 9,29CF21.25.15.02.01.UL (4 G 2,5+(2x1,5)C)C 14,0 182 312 9,29CF21.40.10.02.01.UL (11) (4 G 4,0+(2x1,0)C)C 15,5 232 372 11,22CF21.40.15.02.01.UL (4 G 4,0+(2x1,5)C)C 16,0 241 390 11,22CF21.60.10.02.01.UL (11) (4 G 6,0+(2x1,0)C)C 18,0 327 495 13,54CF21.60.15.02.01.UL (4 G 6,0+(2x1,5)C)C 18,5 357 605 13,54CF21.100.10.02.01.UL (1) / (11) (4 G 10+(2x1,0)C)C 22,0 530 786 21,44CF21.100.15.02.01.UL (4 G 10+(2x1,5)C)C 22,5 540 925 21,44CF21.160.15.02.01.UL (1) (4 G 16+(2x1,5)C)C 24,5 716 1165 25,66CF21.250.15.02.01.UL (1) (4 G 25+(2x1,5)C)C 29,5 1056 1466 36,46CF21.350.15.02.01.UL (1) (4 G 35+(2x1,5)C)C 33,0 1557 2090 45,982 control pairs shieldedCF21.07.03.02.02.UL (4 G 0,75+2x(2x0,34)C)C 12,5 113 210 7,93CF21.10.07.02.02.UL (4 G 1,0+2x(2x0,75)C)C 13,5 146 266 9,34CF21.15.07.02.02.UL (4 G 1,5+2x(2x0,75)C)C 14,5 175 310 9,56CF21.25.15.02.02.UL (4 G 2,5+2x(2x1,5)C)C 17,0 265 370 11,27CF21.40.15.02.02.UL (4 G 4,0+2x(2x1,5)C)C 18,5 304 435 13,87CF21.60.15.02.02.UL (4 G 6,0+2x(2x1,5)C)C 20,5 397 697 16,28CF21.100.15.02.02.UL (4 G 10+2x(2x1,5)C)C 24,0 560 1025 22,72CF21.160.15.02.02.UL (4 G 16+2x(2x1,5)C)C 27,0 790 1270 29,52CF21.250.15.02.02.UL (4 G 25+2x(2x1,5)C)C 31,0 1140 1910 39,84CF21.350.15.02.02.UL (4 G 35+2x(2x1,5)C)C 34,0 1597 2175 48,83(1) Delivery time upon inquiry(11) Phase-out modelNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreClass 5.3.2Order example: CF21.15.10.02.01.UL – in your desired length (0,5 m steps)CF21.UL <strong>Chainflex</strong> ® series .15 Code nominal cross section .10 Code nominal cross section signalpairs.02 Identification pairs .01 Number of pairsPlease use www.chainflex.eu/en/CF21UL for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods172... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.2Price indexCF21.ULPVC7,5 x dTel. +49-2203-96 49-0Fax +49-2203-96 49-222Servo cable<strong>Chainflex</strong> ® CF21.UL: <strong>cables</strong> for energy supply systems in spinneret production. E-Chain ® : Series E2/000950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF21UL (for up to 10 cuts of the same type)173


CF270.UL.DPUR10 x dBending-resistantconductorPUR Servo cable<strong>Chainflex</strong> ® CF270.UL.D● for medium load requirements● PUR outer jacket● shielded● oil-resistant and coolant-resistant● notch-resistant● flame-retardant● hydrolysis-resistant and microbe-resistant● PVC-free/halogen-freeExtremely highlyflexible braided-paircopper shieldTemperature range -20 °C to +80 °C, minimum bending radius 10 x dmovedTemperature range -40 °C to +80 °C, minimum bending radius 5 x dfixedv max.10 m/sunsupporteda max. 50 m/s 2Travel distance Freely suspended travel distances, Class 1UV-resistantMediumEnergy conductor withsignal pair elementsstranded togetherwith elements for hightensile stressesNominal voltage 600/1000 V (following DIN VDE 0250).Testing voltage 4000 V (following DIN VDE 0281-2).Bending-resistantbraided copper shieldOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3.Offshore MUD-resistant following NEK 606.Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Pressure extrudedPUR blendSilicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 192).Halogen-free Following EN 50267-2-1.Class 4.1.3ConductorCore insulationCore strandingFine-wire stranded conductor in bending-resistant versionconsisting of bare copper wires (following EN 60228)Mechanically high-quality, especially low-capacitancePE mixture.Energy conductor with signal pair elements stranded togetherwith elements for high tensile stresses.174Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.1.3Price indexCF270.UL.DPUR10 x dCore identification Energy conductor: cores black with white numerals, one core green-yellow.1. core: U / L1 / C / L+2. core: V / L23. core: W / L3 / D / L-1 signal pair: cores black with white numerals.1. control core: 4 2. control core: 52 signal pairs: cores black with white numerals.1. control core: 5 2. control core: 63. control core: 7 4. control core: 83 control pairs shielded: cores black with white numerals.1. control core: 1 2. control core: 23. control core: 3Star-quad: yellow, black, red, whiteElement shield Bending-resistant, tinned braided copper shield.Coverage approx. 55% linear, approx. 80% optical.Intermediate jacket Foil taping over the external layer.Overall shield Bending-resistant, tinned braided copper shield.Coverage approx. 55% linear, approx. 80% optical.Outer jacketLow-adhesion mixture on the basis of PUR, adapted to suit the requirements in EnergyChains ® (following DIN VDE 0282 Part 10).Colour: Pastel orange (similar to RAL 2003)UL/CSA Style 10989 and 21223, 1000 V, 80 °CServo cableTel. 0 22 03-96 49-0Fax 0 22 03-96 49-222CEI Following CEI 20-35CEFollowing 2006/95/ECDESINAAccording to VDW, DESINA standardisationLead freeFollowing 2002/95/EC (RoHS).Clean roomAccording to ISO Class 1, material/cable tested by IPA according to ISO standard14644-1Typical application arean for medium load requirementsn almost unlimited resistance to oiln indoor and outdoor applications without direct sun radiationn especially for freely suspended travel distancesn Machining units/machine tools, low temperature applications950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF270ULD(for up to 10 cuts of the same type)175


CF270.UL.DPUR10 x dPUR Servo cable<strong>Chainflex</strong> ® CF270.UL.D● for medium load requirements● PUR outer jacket● shielded● oil-resistant and coolant-resistant● notch-resistant● flame-retardant● hydrolysis-resistant and microbe-resistant● PVC-free/halogen-freeClass 4.1.3Image exemplary.Delivery programPart No.1 control pair shieldedCF270.UL.15.15.02.01.D (4 G 1,5+(2x1,5)C)C 12,0 149 246CF270.UL.25.15.02.01.D (4 G 2,5+(2x1,5)C)C 13,5 203 317CF270.UL.40.15.02.01.D (4 G 4,0+(2x1,5)C)C 15,0 272 408CF270.UL.60.15.02.01.D (4 G 6,0+(2x1,5)C)C 16,5 364 521CF270.UL.100.15.02.01.D (1) (4 G 10,0+(2x1,5)C)C 20,5 582 841CF270.UL.160.15.02.01.D (4 G 16,0+(2x1,5)C)C 24,0 855 12252 control pairs shieldedCF270.UL.10.07.02.02.D (4 G 1,0+2x(2x0,75)C)C 13,0 143 251CF270.UL.15.07.02.02.D (4 G 1,5+2x(2x0,75)C)C 13,5 169 290CF270.UL.25.15.02.02.D (4 G 2,5+2x(2x1,5)C)C 15,5 260 408CF270.UL.40.15.02.02.D (4 G 4,0+2x(2x1,5)C)C 17,0 330 506CF270.UL.60.15.02.02.D (1) (4 G 6,0+2x(2x1,5)C)C 18,5 425 633CF270.UL.100.15.02.02.D (4 G 10,0+2x(2x1,5)C)C 22,0 632 940CF270.UL.160.15.02.02.D (1) (4 G 16,0+2x(2x1,5)C)C 26,0 901 1315CF270.UL.250.15.02.02.D (4 G 25,0+2x(2x1,5)C)C 28,0 1365 1847CF270.UL.350.15.02.02.D (1) (4 G 35,0+2x(2x1,5)C)C 35,0 1804 25163 control pairs shieldedCF270.UL.15.10.03.01.D (9) (4 G 1,5+(3x1,0)C)C 14,0 160 288CF270.UL.25.10.03.01.D (10) (4 G 2,5+(3x1,0)C)C 14,0 203 3271 Star-quad shieldedCF270.UL.60.05.04.D (4 G 6,0+(4x0,5)C)C 16,5 350 512Without signal pairCF270.UL.15.04.D (4 G 1,5)C 9,0 82 147CF270.UL.25.04.D (4 G 2,5)C 11,0 141 224CF270.UL.40.04.D (4 G 4,0)C 12,5 211 309CF270.UL.60.04.D (4 G 6,0)C 14,5 306 434CF270.UL.100.04.D (4 G 10,0)C 18,0 496 698CF270.UL.160.04.D (4 G 16,0)C 21,5 782 1052CF270.UL.250.04.D (1) (4 G 25,0)C 25,5 1197 1572CF270.UL.350.04.D (1) (4 G 35,0)C 33,0 1695 2312(1) Delivery time upon inquiry9) Core/core: 50 pF/m, core/shield: 95 pF/m10) Core/core: 70 pF/m, core/shield: 115 pF/mNumber of cores andconductor nominalcross section [mm 2 ]Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreExternaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]NewNew176... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 4.1.3Price indexCF270.UL.DPUR10 x dOrder example: CF270.UL.25.15.02.01.D – in your desired length (0,5 m steps)CF270.UL.D <strong>Chainflex</strong> ® series .25 Code nominal cross section .15 Code nominal cross section signal pairs.02 Identification pairs .01 Number of pairsPlease use www.chainflex.eu/en/CF270ULD for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsServo cableTel. 0 22 03-96 49-0Fax 0 22 03-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF270ULD(for up to 10 cuts of the same type)177


CF27.DPUR7,5 x dHighly flexiblespecial conductorPUR Servo cable<strong>Chainflex</strong> ® CF27.D● for maximum load requirements● PUR outer jacket● shielded● oil-resistant and coolant-resistant● notch-resistant● flame-retardant● hydrolysis-resistant and microbe-resistant● PVC-free/halogen-freeEnergy conductorwith signal pairelements strandedaround high-tensilecenter cordTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-20 °C to +80 °C, minimum bending radius 7,5 x d-40 °C to +80 °C, minimum bending radius 4 x d10 m/s, 5 m/sExtremely highlyflexible braided-paircopper shielda max. 80 m/s 2Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3UV-resistantMediumGusset-filledextrudedNominal voltage 600/1000 V (following DIN VDE 0250).Testing voltage 4000 V (following DIN VDE 0281-2).Highly flexiblebraided coppershieldOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3Offshore MUD-resistant following NEK 606Pressure extruded,halogen-free PURblendFlame-retardantSilicon-freeAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Class 6.3.3ConductorCore insulationCore strandingFine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Mechanically high-quality, especially low-capacitance TPEmixture.Energy conductor with signal pair elements stranded aroundhigh-tensile center cord.178Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.3.3Price indexCF27.DPUR7,5 x dCore identificationEnergy conductor: cores black with white numerals, one core green/yellow.1. core: U / L1 / C / L+ 2. core: V / L23. core: W / L3 / D / L-1 control pair: cores black with white numerals.1. control pair: 4 2. control pair: 52 control pairs: cores black with white numerals.1. control pair: 5 2. control pair: 63. control pair: 7 4. control pair: 8Star-quad: yellow, black, red, whiteServo cableElement shieldExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Inner jacket PUR mixture adapted to suit the requirements in Energy Chains ® .Overall shield Extremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Outer jacketLow-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suitthe requirements in Energy Chains ® (following DIN VDE 0282 Part 10).Colour: Pastel orange (similar to RAL 2003)UL/CSA Style 10492 and 20234, 1000 V, 80 °CCEI Following CEI 20-35Tel. +49-2203-96 49-0Fax +49-2203-96 49-222CEFollowing 2006/95/ECDESINAAccording to VDW, DESINA standardisationLead freeFollowing 2002/95/EC (RoHS).Clean roomAccording to ISO Class 1, material/cable tested by IPA according to ISO standard14644-1Typical application arean for maximum load requirementsn almost unlimited resistance to oiln indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 100 mn storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, outdoor cranes, low-temperature applications950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF27D(for up to 10 cuts of the same type)179


CF27.DPUR7,5 x dPUR Servo cable<strong>Chainflex</strong> ® CF27.D● for maximum load requirements● PUR outer jacket● shielded● oil-resistant and coolant-resistant● notch-resistant● flame-retardant● hydrolysis-resistant and microbe-resistant● PVC-free/halogen-freeClass 6.3.3Image exemplary.Delivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]1 control pair shieldedCF27.07.05.02.01.D (4 G 0,75+(2x0,5)C)C 11,5 95 171CF27.15.10.02.01.D (11) (4 G 1,5+(2x1,0)C)C 12,5 125 220CF27.15.15.02.01.D (4 G 1,5+(2x1,5)C)C 13,0 140 260CF27.25.10.02.01.D (11) (4 G 2,5+(2x1,0)C)C 13,5 177 286CF27.25.15.02.01.D (4 G 2,5+(2x1,5)C)C 14,0 182 300CF27.40.10.02.01.D (11) (4 G 4,0+(2x1,0)C)C 16,0 232 356CF27.40.15.02.01.D (4 G 4,0+(2x1,5)C)C 16,0 256 400CF27.60.10.02.01.D (11) (4 G 6,0+(2x1,0)C)C 17,5 327 481CF27.60.15.02.01.D (4 G 6,0+(2x1,5)C)C 17,5 357 580CF27.100.10.02.01.D (11) (4 G 10,0+(2x1,0)C)C 20,5 530 740CF27.100.15.02.01.D (4 G 10,0+(2x1,5)C)C 21,5 540 900CF27.160.10.02.01.D (11) (4 G 16,0+(2x1,0)C)C 23,0 700 1023CF27.160.15.02.01.D (4 G 16,0+(2x1,5)C)C 24,5 716 1150CF27.250.15.02.01.D (4 G 25,0+(2x1,5)C)C 28,5 1056 1435CF27.350.15.02.01.D (4 G 35,0+(2x1,5)C)C 32,5 1553 20792 control pairs shieldedCF27.07.03.02.02.D (4 G 0,75+2x(2x0,34)C)C 12,5 102 195CF27.10.07.02.02.D (4 G 1,0+2x(2x0,75)C)C 13,5 143 251CF27.15.07.02.02.D (4 G 1,5+2x(2x0,75)C)C 14,5 175 295CF27.25.15.02.02.D (4 G 2,5+2x(2x1,5)C)C 16,5 265 349CF27.40.15.02.02.D (4 G 4,0+2x(2x1,5)C)C 18,0 303 405CF27.60.15.02.02.D (4 G 6,0+2x(2x1,5)C)C 19,5 397 643CF27.100.15.02.02.D (4 G 10,0+2x(2x1,5)C)C 23,5 560 1000CF27.160.15.02.02.D (4 G 16,0+2x(2x1,5)C)C 26,0 790 1250CF27.250.15.02.02.D (4 G 25,0+2x(2x1,5)C)C 31,0 1140 1890CF27.350.15.02.02.D (1) (4 G 35,0+2x(2x1,5)C)C 33,5 1597 21501 star quad shieldedCF27.15.05.04.D (4 G 1,5+(4x0,5)C)C 14,5 142 310CF27.25.05.04.D (4 G 2,5+(4x0,5)C)C 15,0 199 325CF27.40.05.04.D (4 G 4,0+(4x0,5)C)C 17,0 256 480CF27.60.05.04.D (4 G 6,0+(4x0,5)C)C 18,0 371 550(1) Delivery time upon inquiry(11) Phase-out modelNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core180... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.3.3Delivery programNumber of cores andPart No.conductor nominalcross section [mm 2 ]Price indexExternal Copper Weightdiameter index [kg/km]approx. [mm] [kg/km]Without control pairCF27.07.04.D (1) (4 G 0,75)C 9,5 52 113CF27.10.04.D (1) (4 G 1,0)C 10,0 62 126CF27.15.04.D (4 G 1,5)C 10,5 86 160CF27.25.04.D (4 G 2,5)C 12,0 140 260CF27,500.04.D (4 G 50,0)C 37,5 2230 3200CF27.DPUR7,5 x dServo cable(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF27.15.10.02.01.D – in your desired length (0,5 m steps)CF27 <strong>Chainflex</strong> ® series .15 Code nominal cross section .10 Code nominal cross section signalpairs.02 Identification pairs .01 Number of pairsPlease use www.chainflex.eu/en/CF27D for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTel. +49-2203-96 49-0Fax +49-2203-96 49-222Modular design, easy to retrofit: igus ® E4 energy supply system and <strong>Chainflex</strong> ® <strong>cables</strong>.950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF27D(for up to 10 cuts of the same type)181


182ower cable


<strong>Chainflex</strong> ®cableJacketShield<strong>Chainflex</strong> ®Minimum bendingradius, moved[factor x d]Temperaturemovedfrom/to [°C]typesApprovals andstandardsOil-resistantTorsion resistantv max. [m/s]unsupportedv max. [m/s]glidinga max. [m/s 2 ]PagePower <strong>cables</strong>CF30 PVC 7,5 -5/ +70 ✔ ✔ 10 5 80 184CF31 PVC ✔ 7,5 -5/ +70 ✔ 10 5 80 186CF34.UL.D TPE 7,5 -35/ +90 ✔ ✔ 10 6 80 188CF35.UL TPE ✔ 7,5 -35/ +90 ✔ 10 6 80 190CF37.D TPE 7,5 -35/ +90 ✔ ✔ 10 6 80 192CF38 TPE ✔ 7,5 -35/ +90 ✔ 10 6 80 194CF300.UL.D TPE 7,5 -35/ +90 ✔ ✔ 10 6 100 196CFPE TPE 7,5 -35/ +90 ✔ ✔ 10 6 100 198CF310.UL TPE ✔ 7,5 -35/ +90 ✔ 10 6 100 200CF330.D TPE 7,5 -35/ +90 ✔ ✔ 10 6 100 202CF340 TPE ✔ 7,5 -35/ +90 ✔ 10 6 100 204CF FLAT TPE 5 -35/ +90 ✔ 10 6 100 206CF BRAID TPE 7,5 -35/ +70 ✔ 10 6 80 208CF BRAID.C TPE ✔ 7,5 -35/ +70 ✔ 10 6 80 208CF CRANE igupren ✔ 10 -20/ +80 ✔ 10 6 50 210Pneumatic hosesCFAIR PU 10 -25/ +80 ✔ 10 6 50 212CF Clean AIR PE 10 -25/ +60 ✔ 10 6 50 214183


CF30PVC7,5 x dPVC Power cable<strong>Chainflex</strong> ® CF30● for high load requirements● PVC outer jacket● oil-resistant● flame-retardantHighly flexiblespecial conductorTemperature range -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2,moved+5 °C to +70 °C for use in Energy Chains ® with > 50.000 cycles.Minimum bending radius 7,5 x d.Temperature rangefixed-20 °C to +70 °C, minimum bending radius 4 x dv max.unsupported/gliding 10 m/s, 5 m/sa max. 80 m/s 2Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3Torsion± 90 °, with 1 m cable lengthUV-resistantMediumNominal voltage 600/1000 V (following DIN VDE 0250).Energy conductorstranded aroundhigh-tensilecenter cordTesting voltage 4000 V (following DIN VDE 0281-2).Oil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1),Class 2Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Gusset-filledextruded,oil-resistantPVC mixtureClass 5.3.2184Image exemplary.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Conductor< 10 mm 2 : Fine-wire stranded conductor in especiallybending-resistant version consisting of bare copper wires(following EN 60228).≥ 10 mm 2 : conductor cable consisting of pre-leads(following EN 60228).Core insulation Mechanically high-quality, especially low-capacitance TPEmixture.Core stranding Cores stranded in short pitch lengths over a centre for hightensile stresses.Core identification Energy conductor: cores black with white numerals, onecore green/yellow.1. core: U / L1 / C / L+ 2. core: V / L23. core: W / L3 / D / L- 4. core: 4 / NOuter jacketLow-adhesion, oil-resistant mixture on the basis of PVC, adaptedto suit the requirements in Energy Chains ® (following DINVDE 0281 Part 13).Colour: Jet black (similar to RAL 9005)UL/CSA Style 10492 and 2570, 1000 V, 80 °C... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.2Price indexCF30PVC7,5 x dCEI Following CEI 20-35CELead freeClean roomFollowing 2006/95/ECFollowing 2002/95/EC (RoHS)According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested byIPA according to standard 14644-1Power cableTypical application arean for high load requirementsn light oil influencen preferably indoor applications, but also outdoor ones at temperatures > 5 °Cn especially for freely suspended and gliding travel distances up to 100 mn storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranesDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF30.15.04 4 G 1,5 8,5 58 105CF30.25.04 4 G 2,5 10,5 96 165CF30.25.05 5 G 2,5 11,5 125 199CF30.40.04 4 G 4,0 12,0 158 242CF30.40.05 5 G 4,0 13,0 198 295CF30.60.04 4 G 6,0 14,0 239 351CF30.60.05 5 G 6,0 15,0 290 417CF30.100.04 4 G 10,0 18,0 411 581CF30.100.05 5 G 10,0 20,0 517 731CF30.160.04 4 G 16,0 21,0 639 904CF30.160.05 5 G 16,0 24,0 800 1132CF30.250.04 4 G 25,0 26,0 1020 1425CF30.350.04 4 G 35,0 29,0 1420 1810CF30.500.04 4 G 50,0 35,0 1990 2675Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Order example: CF30.15.04 – in your desired length (0,5 m steps)CF30 <strong>Chainflex</strong> ® series .15 Code nominal cross section .04 Number of coresPlease use www.chainflex.eu/en/CF30 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF30(for up to 10 cuts of the same type)185


CF31PVC7,5 x dHighly flexiblespecial conductorPVC Power cable<strong>Chainflex</strong> ® CF31● for high load requirements● PVC outer jacket● shielded● oil-resistant● flame-retardantEnergy conductorstranded aroundhigh-tensilecenter cordTemperature range -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2,moved+5 °C to +70 °C for use in Energy Chains ® with > 50.000 cycles.Minimum bending radius 7,5 x d.Temperature rangefixed-20 °C to +70 °C, minimum bending radius 4 x dv max.unsupported/gliding 10 m/s, 5 m/sa max. 80 m/s 2Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3UV-resistantMediumNominal voltage 600/1000 V (following DIN VDE 0250).Testing voltage 4000 V (following DIN VDE 0281-2).Gusset-filledextrudedHighly flexiblebraided coppershieldPressureextruded,oil-proof PVCsheath blendClass 5.3.2186Image exemplary.Oil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1),Class 2Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Conductor< 10 mm 2 : Fine-wire stranded conductor in especiallybending-resistant version consisting of bare copper wires(following EN 60228).≥ 10 mm 2 : conductor cable consisting of pre-leads(following EN 60228).Core insulation Mechanically high-quality, especially low-capacitance TPEmixture.Core stranding Cores stranded in short pitch lengths over a centre for hightensile stresses.Core identification Energy conductor: cores black with white numerals, onecore green/yellow.1. core: U / L1 / C / L+ 2. core: V / L23. core: W / L3 / D / L- 4. core: 4 / NInner jacket PVC mixture adapted to suit the requirements in Energy Chains ® .Overall shield Extremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Outer jacketLow-adhesion, oil-resistant mixture on the basis of PVC, adaptedto suit the requirements in Energy Chains ® (following DIN VDE0281 Part 13). Colour: Jet black (similar to RAL 9005)UL/CSA Style 10492 and 2570, 1000 V, 80 °C... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 5.3.2Price indexCF31PVC7,5 x dCEI Following CEI 20-35CELead freeClean roomFollowing 2006/95/ECFollowing 2002/95/EC (RoHS)According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested byIPA according to standard 14644-1Power cableTypical application arean for high load requirementsn light oil influencen preferably indoor applications, but also outdoor ones at temperatures > 5 °Cn especially for freely suspended and gliding travel distances up to 100 mn storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranesDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]CF31.15.04 (4 G 1,5)C 10,5 85 171CF31.25.04 (4 G 2,5)C 12,0 129 237CF31.25.05 (5 G 2,5)C 13,0 158 280CF31.40.04 (4 G 4,0)C 13,5 197 326CF31.40.05 (5 G 4,0)C 15,0 253 397CF31.60.04 (4 G 6,0)C 16,0 299 475CF31.60.05 (5 G 6,0)C 18,0 362 577CF31.100.04 (4 G 10,0)C 21,0 501 772CF31.100.05 (5 G 10,0)C 23,0 624 934CF31.160.04 (4 G 16,0)C 24,0 748 1090CF31.250.04 (4 G 25,0)C 28,5 1160 1643CF31.350.04 (4 G 35,0)C 32,5 1570 2155CF31.500.04 (4 G 50,0)C 38,5 2180 3125CF31.700.04 (5) (4 G 70,0)C 46,5 2965 4367Tel. +49-2203-96 49-0Fax +49-2203-96 49-222(5) Cable with PVC core insulation, UL-Style 10579 and 2570 , 600 V, 80 °CNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF31.25.04 – in your desired length (0,5 m steps)CF31 <strong>Chainflex</strong> ® series .25 Code nominal cross section .04 Number of coresPlease use www.chainflex.eu/en/CF31 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF31(for up to 10 cuts of the same type)187


CF34.UL.DTPE7,5 x dTPE Power cable<strong>Chainflex</strong> ® CF34.UL.D● for maximum load requirements● TPE outer jacket● oil- and bio-oil-resistant● flame-retardant● UV-resistant● hydrolysis-resistant and microbe-resistantHighly flexiblespecial conductorTemperature rangemoved-35 °C to +90 °C, minimum bending radius 7,5 x dTemperature rangefixed-40 °C to +90 °C, minimum bending radius 4 x dv max.unsupported/gliding 10 m/s, 6 m/sa max. 80 m/s 2Travel distanceTorsionUV-resistantFreely suspended and gliding travel distances up to 400 mand more, Class 4± 90 °, with 1 m cable lengthHighNominal voltage 600/1000 V (following DIN VDE 0250).Testing voltage 4000 V (following DIN VDE 0281-2).Energy conductorstranded aroundhigh-tensilecenter cordOilFlame-retardantOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Gusset-filledextrudedTPE mixtureClass 6.4.4188Image exemplary.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Conductor< 10 mm 2 : Fine-wire stranded conductor in especiallybending-resistant version consisting of bare copper wires(following EN 60228).≥ 10 mm 2 : conductor cable consisting of pre-leads(following EN 60228).Core insulation Mechanically high-quality, especially low-capacitance TPEmixture.Core stranding Cores stranded in short pitch lengths over a centre for hightensile stresses.Core identification Energy conductor: cores black with white numerals, onecore green/yellow.1. core: U / L1 / C / L+ 2. core: V / L23. core: W / L3 / D / L- 4. core: 4 / NOuter jacketLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® . Colour: Jet black (similar to RAL 9005)UL/CSA Style 10492 and 21184, 1000 V, 80 °CCEI Following CEI 20-35... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF34.UL.DTPE7,5 x dCEFollowing 2006/95/ECDESINALead freeClean roomAccording to VDW, DESINA standardisationFollowing 2002/95/EC (RoHS).According to ISO Class 1, material/cable tested by IPA according to ISO standard14644-1Power cableTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]CF34.UL.15.04.D 4 G 1,5 8,5 58 109CF34.UL.25.04.D 4 G 2,5 10,5 96 162CF34.UL.40.04.D 4 G 4,0 12,0 158 239CF34.UL.60.04.D 4 G 6,0 14,0 239 351CF34.UL.60.05.D 5 G 6,0 15,5 285 420CF34.UL.100.04.D 4 G 10,0 17,0 411 549CF34.UL.100.05.D 5 G 10,0 19,5 517 687CF34.UL.160.04.D 4 G 16,0 20,5 633 817CF34.UL.160.05.D 5 G 16,0 23,0 800 1072CF34.UL.250.04.D 4 G 25,0 25,0 994 1266Tel. +49-2203-96 49-0Fax +49-2203-96 49-222CF34.UL.60.04.O.PE.D 4 x 6,0 14,0 239 351CF34.UL.100.04.O.PE.D 4 x 10,0 17,0 411 549CF34.UL.160.04.O.PE.D 4 x 16,0 20,5 633 817CF34.UL.500.03.O.PE.D 3 x 50,0 31,0 1490 2028Other types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF34.UL.160.04.D – in your desired length (0,5 m steps)CF34.UL <strong>Chainflex</strong> ® series .160 Code nominal cross section .04 Number of coresPlease use www.chainflex.eu/en/CF34 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF34(for up to 10 cuts of the same type)189


CF35.ULTPE7,5 x dHighly flexiblespecial conductorEnergy conductorstranded aroundhigh-tensilecenter cordTPE Power cable<strong>Chainflex</strong> ® CF35.UL● for maximum load requirements● TPE outer jacket● shielded● oil- and bio-oil-resistant● flame-retardant● UV-resistant● hydrolysis-resistant and microbe-resistantTemperature rangemoved-35 °C to +90 °C, minimum bending radius 7,5 x dTemperature rangefixed-40 °C to +90 °C, minimum bending radius 4 x dv max.unsupported/gliding 10 m/s, 6 m/sa max. 80 m/s 2Travel distanceUV-resistantFreely suspended and gliding travel distances up to 400 mand more, Class 4HighNominal voltage 600/1000 V (following DIN VDE 0250).Testing voltage 4000 V (following DIN VDE 0281-2).Gusset-filled,pressure extrudedTPE inner jacketOilFlame-retardantOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Highly flexiblebraided coppershieldPressure extrudedTPE blendClass 6.4.4190Image exemplary.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Conductor< 10 mm 2 : Fine-wire stranded conductor in especiallybending-resistant version consisting of bare copper wires(following EN 60228).≥ 10 mm 2 : conductor cable consisting of pre-leads(following EN 60228).Core insulation Mechanically high-quality, especially low-capacitance TPEmixture.Core stranding Cores stranded in short pitch lengths over a centre for hightensile stresses.Core identification Energy conductor: cores black with white numerals,one core green/yellow.1. core: U / L1 / C / L+ 2. core: V / L23. core: W / L3 / D / L- 4. core: 4 / NInner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Overall shieldOuter jacketExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® . Colour: Jet black (similar to RAL 9005)UL/CSA Style 10492 and 21184, 1000 V, 80 °C... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF35.ULTPE7,5 x dCEI Following CEI 20-35CELead freeClean roomFollowing 2006/95/ECFollowing 2002/95/EC (RoHS).According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, testedby IPA according to standard 14644-1Power cableTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]CF35.UL.05.04 (4 G 0,5)C 8,0 39 81CF35.UL.07.04 (4 G 0,75)C 8,5 52 104CF35.UL.15.04 (4 G 1,5)C 9,5 85 149CF35.UL.25.04 (4 G 2,5)C 11,5 128 207CF35.UL.40.04 (4 G 4,0)C 13,5 201 326CF35.UL.60.04 (4 G 6,0)C 16,0 298 450CF35.UL.100.04 (4 G 10,0)C 19,5 454 682CF35.UL.160.04 (4 G 16,0)C 23,0 723 1003CF35.UL.250.04 (4 G 25,0)C 27,5 1160 1524Tel. +49-2203-96 49-0Fax +49-2203-96 49-222CF35.UL.60.03.O.PE (1) (3 x 6,0)C 14,5 231 367CF35.UL.100.03.O.PE (1) (3 x 10,0)C 17,5 356 568CF35.UL.160.03.O.PE (3 x 16,0)C 21,0 553 789CF35.UL.250.03.O.PE (1) (3 x 25,0)C 24,5 884 1208CF35.UL.350.03.O.PE (3 x 35,0)C 28,5 1200 1675CF35.UL.500.03.O.PE (3 x 50,0)C 33,5 1660 2283(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF35.UL.15.04 – in your desired length (0,5 m steps)CF35.UL <strong>Chainflex</strong> ® series .15 Code nominal cross section .04 Number of coresPlease use www.chainflex.eu/en/CF35 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF35(for up to 10 cuts of the same type)191


CF37.DTPE7,5 x dTPE power cable<strong>Chainflex</strong> ® CF37.D● for maximum load requirements● TPE outer jacket● oil- and bio-oil-resistant● PVC-free/halogen-free● UV-resistant● hydrolysis-resistant and microbe-resistantHighly flexiblespecial conductorTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +90 °C, minimum bending radius 7,5 x d-40 °C to +90 °C, minimum bending radius 4 x d10 m/s, 6 m/sa max. 80 m/s 2Travel distanceTorsionFreely suspended and gliding travel distances up to 400 mand more, Class 4± 90 °, with 1 m cable lengthUV-resistantHighNominal voltage 600/1000 V (following DIN VDE 0250).Energy conductorstranded aroundhigh-tensile centercordTesting voltage 4000 V (following DIN VDE 0281-2).OilOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (followingVDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Gusset-filledextruded TPEmixtureClass 7.4.4192Image exemplary.Halogen-free Following EN 50267-2-1.ConductorCore insulationCore strandingCore identificationOuter jacket< 10 mm 2 : stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).≥ 10 mm 2 : conductor cable consisting of pre-leads (followingEN 60228).Mechanically high-quality, especially low-capacitance TPEmixture.Cores stranded in short pitch lengths over a centre for hightensile stresses.Energy conductor: cores black with white numerals, onecore green-yellow.1. core: U / L1 / C / L+ 2. core: V / L23. core: W / L3 / D / L- 4. core: 4 / NLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® . Colour: Jet black (similar to RAL 9005)... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.4.4Price indexCF37.DTPE7,5 x dCEFollowing 2006/95/ECDESINAAccording to VDW, DESINA standardisationLead freeFollowing 2002/95/EC (RoHS)Clean room According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1Power cableTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]CF37.15.04.D 4 G 1,5 8,5 58 109CF37.25.04.D 4 G 2,5 10,5 96 162CF37.40.04.D (1) 4 G 4,0 12,0 158 239CF37.60.04.D 4 G 6,0 14,0 239 351CF37.60.05.D (1) 5 G 6,0 15,5 285 420CF37.100.04.D 4 G 10,0 17,0 411 549CF37.100.05.D (1) 5 G 10,0 19,5 517 687CF37.160.04.D 4 G 16,0 20,5 633 817CF37.160.05.D (1) 5 G 16,0 23,0 800 1072CF37.250.04.D 4 G 25,0 25,0 994 1266Tel. +49-2203-96 49-0Fax +49-2203-96 49-222CF37.60.04.O.PE.D (1) 4 x 6 14,0 239 351CF37.100.04.O.PE.D (1) 4 x 10 17,0 411 549CF37.160.04.O.PE.D (1) 4 x 16 20,5 633 817CF37,500.03.O.PE.D 3 x 50 31,0 1490 2028(1) Delivery time upon inquiryOther types available on request.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF37.250.04.D – in your desired length (0,5 m steps)CF37.D <strong>Chainflex</strong> ® series .250 Code nominal cross section .04 Number of coresPlease use www.chainflex.eu/en/CF37 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF37(for up to 10 cuts of the same type)193


CF38TPE7,5 x dTPE power cable<strong>Chainflex</strong> ® CF38● for maximum load requirements● TPE outer jacket● shielded● oil- and bio-oil-resistant● PVC-free/halogen-free● UV-resistant● hydrolysis-resistant and microbe-resistantHighly flexiblespecial conductorTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +90 °C, minimum bending radius 7,5 x d-40 °C to +90 °C, minimum bending radius 4 x d10 m/s, 6 m/sa max. 80 m/s 2Energy conductorstranded aroundhigh-tensile centercordTravel distanceUV-resistantFreely suspended and gliding travel distances up to 400 mand more, Class 4HighNominal voltage 600/1000 V (following DIN VDE 0250).Gusset-filled pressureextruded TPE innerjacketHighly flexiblebraided coppershieldTesting voltage 4000 V (following DIN VDE 0281-2).OilSilicon-freeOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (followingVDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Pressure extrudedTPE blendClass 7.4.4194Image exemplary.ConductorCore insulationCore strandingCore identification< 10 mm 2 : stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).≥ 10 mm 2 : conductor cable consisting of pre-leads (followingEN 60228).Mechanically high-quality, especially low-capacitance TPEmixture.Cores stranded in short pitch lengths over a centre for hightensile stresses.Energy conductor: cores black with white numerals, onecore green-yellow.1. core: U / L1 / C / L+ 2. core: V / L23. core: W / L3 / D / L- 4. core: 4 / NInner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .Overall shieldOuter jacketExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® . Colour: Jet black (similar to RAL 9005)... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.4.4Price indexCF38TPE7,5 x dCEFollowing 2006/95/ECLead freeClean roomFollowing 2002/95/EC (RoHS)According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, testedby IPA according to standard 14644-1Power cableTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]CF38.05.04 (1) (4 G 0,5)C 8,0 39 81CF38.07.04 (1) (4 G 0,75)C 8,5 52 104CF38.15.04 (4 G 1,5)C 9,5 85 149CF38.25.04 (1) (4 G 2,5)C 11,5 128 207CF38.40.04 (4 G 4,0)C 13,5 201 326CF38.60.04 (1) (4 G 6,0)C 16,0 298 450CF38.100.04 (4 G 10,0)C 19,5 454 682CF38.160.04 (4 G 16,0)C 23,0 723 1003CF38.250.04 (4 G 25,0)C 27,5 1160 1524Tel. +49-2203-96 49-0Fax +49-2203-96 49-222CF38.60.03.O.PE (1) (3 x 6,0)C 14,5 231 367CF38.100.03.O.PE (1) (3 x 10,0)C 17,5 356 568CF38.160.03.O.PE (1) (3 x 16,0)C 21,0 553 789CF38.250.03.O.PE (1) (3 x 25,0)C 24,5 884 1208CF38.350.03.O.PE (1) (3 x 35,0)C 28,5 1200 1675CF38.500.03.O.PE (1) (3 x 50,0)C 33,5 1660 2283(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF38.25.04 – in your desired length (0,5 m steps)CF38 <strong>Chainflex</strong> ® series .25 Code nominal cross section .04 Number of coresPlease use www.chainflex.eu/en/CF38 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF38(for up to 10 cuts of the same type)195


CF300.UL.DTPE7,5 x dHighly flexiblespecial conductorTPE Power cable<strong>Chainflex</strong> ® CF300.UL.D● for maximum load requirements● TPE outer jacket● oil- and bio-oil-resistant● flame-retardant● UV-resistant● hydrolysis-resistant and microbe-resistantTemperature rangemoved-35 °C to +90 °C, minimum bending radius 7,5 x dTemperature rangefixed-40 °C to +90 °C, minimum bending radius 4 x dv max.unsupported/gliding 10 m/s, 6 m/sa max. 100 m/s 2Travel distanceTorsionFreely suspended and gliding travel distances up to 400 mand more, Class 4± 90 °, with 1 m cable lengthUV-resistantHighNominal voltage 600/1000 V (following DIN VDE 0250).Testing voltage 4000 V (following DIN VDE 0281-2).Pressure extrudedTPE blendOilOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Flame-retardantAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.PressureextrudedTPE blendSilicon-freeConductorCore insulationFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Conductor cable consisting of pre-leads (following EN60228).Mechanically high-quality TPE mixture.Outer jacketLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® . Colour: Jet black (similar to RAL 9005)Class 6.4.4196Image exemplary.CEFollowing 2006/95/ECUL/CSA Style 10492 and 21184, 1000 V, 80 °CCEI Following CEI 20-35Lead freeClean roomFollowing 2002/95/EC (RoHS).According to ISO Class 1. Outer jacket material complies withCF34.UL.25.04.D, tested by IPA according to standard 14644-1... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF300.UL.DTPE7,5 x dTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsPower cableDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CF300.UL.60.01.D 1x6,0 7,0 56 77CF300.UL.100.01.D 1x10,0 8,0 96 119CF300.UL.160.01.D 1x16,0 9,5 151 183CF300.UL.250.01.D 1x25,0 11,5 239 281CF300.UL.350.01.D 1x35,0 12,5 333 377CF300.UL.500.01.D 1x50,0 14,5 479 525CF300.UL.700.01.D 1x70,0 16,0 623 676CF300.UL.950.01.D 1x95,0 19,0 848 927CF300.UL.1200.01.D 1x120,0 21,5 1059 1145CF300.UL.1500.01.D 1x150,0 23,0 1318 1411CF300.UL.1850.01.D 1x185,0 27,0 1890 2014Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Order example: CF300.UL.950.01.D – in your desired length (0,5 m steps)CF300.UL.D <strong>Chainflex</strong> ® series .950 Code nominal cross section .01 Number of coresPlease use www.chainflex.eu/en/CF300 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsSTS cranes in Antwerp with igus ® Energy Chain Systems ® for energy and data supplies to centenary and main trolley.950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF300(for up to 10 cuts of the same type)197


CFPETPE7,5 x dHighly flexiblespecial conductorTPE Power cable<strong>Chainflex</strong> ® CFPE● for maximum load requirements● TPE outer jacket● oil- and bio-oil-resistant● flame-retardant● UV-resistant● hydrolysis-resistant and microbe-resistantTemperature rangemoved-35 °C to +90 °C, minimum bending radius 7,5 x dTemperature rangefixed-40 °C to +90 °C, minimum bending radius 4 x dv max.unsupported/gliding 10 m/s, 6 m/sa max. 100 m/s 2Travel distanceTorsionUV-resistantFreely suspended and gliding travel distances up to 400 mand more, Class 4± 90 °, with 1 m cable lengthHighNominal voltage 600/1000 V (following DIN VDE 0250).Testing voltage 4000 V (following DIN VDE 0281-2).Pressure extrudedTPE blendOilFlame-retardantOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Conductor Conductor cable consisting of pre-leads (following EN 60228).Pressureextruded,flame-retardTPE blendCore insulationCore identificationMechanically high-quality TPE mixture.green-yellowOuter jacketLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® . Colour: Jet black (similar to RAL 9005)Class 6.4.4198Image exemplary.UL/CSA Style 10492 and 21184, 1000 V, 80 °CCEI Following CEI 20-35CELead freeClean roomFollowing 2006/95/ECFollowing 2002/95/EC (RoHS).According to ISO Class 1. Outer jacket material complies withCF34.UL.25.04.D, tested by IPA according to standard 14644-1... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCFPETPE7,5 x dTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsPower cableDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CFPE.15.01 1 G 1,5 5,0 15 35CFPE.25.01 1 G 2,5 6,0 25 46CFPE.40.01 1 G 4,0 6,5 38 61CFPE.60.01 1 G 6,0 7,0 56 81CFPE.100.01 1 G 10,0 8,0 96 123CFPE.160.01 1 G 16,0 9,5 151 191CFPE.250.01 1 G 25,0 11,5 239 291CFPE.350.01 1 G 35,0 13,0 333 387Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Order example: CFPE.15.01 – in your desired length (0,5 m steps)CFPE <strong>Chainflex</strong> ® series .15 Code nominal cross section .01 Number of coresPlease use www.chainflex.eu/en/CFPE for your online order.Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery time 24h or today** Delivery time means time until shipping of goods<strong>Chainflex</strong> ® CFPE for machining units. E-Chain ® : Series E2 medium950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFPE(for up to 10 cuts of the same type)199


CF310.ULTPE7,5 x dHighly flexiblespecial conductorTPE Power cable<strong>Chainflex</strong> ® CF310.UL● for maximum load requirements● TPE outer jacket● shielded● oil- and bio-oil-resistant● flame-retardant● UV-resistant● hydrolysis-resistant and microbe-resistantTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +90 °C, minimum bending radius 7,5 x d-40 °C to +90 °C, minimum bending radius 4 x d10 m/s, 6 m/sa max. 100 m/s 2Travel distanceUV-resistantFreely suspended and gliding travel distances up to 400 mand more, Class 4HighNominal voltage 600/1000 V (following DIN VDE 0250).Pressure extrudedTPE blendTesting voltage 4000 V (following DIN VDE 0281-2).Highly flexiblebraided coppershieldOilFlame-retardantOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.PressureextrudedTPE blendSilicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Conductor Conductor cable consisting of pre-leads (following EN 60228).Core insulationMechanically high-quality TPE mixture.Class 6.4.4Overall shieldOuter jacketExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® .Colour: Jet black (similar to RAL 9005)UL/CSA Style 10492 and 21184, 1000 V, 80 °CCEI Following CEI 20-35CEFollowing 2006/95/EC200Image exemplary.Lead freeFollowing 2002/95/EC (RoHS).... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCF310.ULTPE7,5 x dClean roomAccording to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, testedby IPA according to standard 14644-1Typical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsPower cableDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF310.UL.40.01 (1x4,0)C 6,5 55 74CF310.UL.60.01 (1x6,0)C 7,5 75 97CF310.UL.100.01 (1x10,0)C 8,5 120 144CF310.UL.160.01 (1x16,0)C 10,0 178 210CF310.UL.250.01 (1x25,0)C 11,5 272 314CF310.UL.350.01 (1x35,0)C 13,5 380 423CF310.UL.500.01 (1x50,0)C 15,0 524 568CF310.UL.700.01 (1x70,0)C 17,5 689 748CF310.UL.950.01 (1x95,0)C 20,5 920 997CF310.UL.1200.01 (1x120,0)C 22,0 1140 1233CF310.UL.1500.01 (1x150,0)C 24,0 1436 1549CF310.UL.1850.01 (1x185,0)C 28,0 2020 2147Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF310.UL.40.01 – in your desired length (0,5 m steps)CF310.UL <strong>Chainflex</strong> ® series .40 Code nominal cross section .01 Number of coresPlease use www.chainflex.eu/en/CF310 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods<strong>Chainflex</strong> ® CF310.UL for outdoor crane systems. E-Chain ® : Series E4/00950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF310(for up to 10 cuts of the same type)201


CF330.DTPE7,5 x dHighly flexiblespecial conductorTPE power cable<strong>Chainflex</strong> ® CF330.D● for maximum load requirements● TPE outer jacket● oil- and bio-oil-resistant● PVC-free/halogen-free● UV-resistant● hydrolysis-resistant and microbe-resistantTemperature rangemoved-35 °C to +90 °C, minimum bending radius 7,5 x dTemperature rangefixed-40 °C to +90 °C, minimum bending radius 4 x dv max.unsupported/gliding 10 m/s, 6 m/sa max. 100 m/s 2Travel distanceTorsionFreely suspended and gliding travel distances up to 400 mand more, Class 4± 90 °, with 1 m cable lengthUV-resistantHighNominal voltage 600/1000 V (following DIN VDE 0250).Testing voltage 4000 V (following DIN VDE 0281-2).Pressure extrudedTPE blendOilSilicon-freeOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Pressure extrudedTPE blendConductor Conductor cable consisting of pre-leads (following EN 60228).Core insulationMechanically high-quality TPE mixture.Outer jacketLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® . Colour: Jet black (similar to RAL 9005)Class 7.4.4202Image exemplary.CEDESINALead freeClean roomFollowing 2006/95/ECAccording to VDW, DESINA standardisationFollowing 2002/95/EC (RoHS).According to ISO Class 1. Outer jacket material complies withCF34.UL.25.04.D, tested by IPA according to standard 14644-1... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.4.4Price indexCF330.DTPE7,5 x dTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsPower cableDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF330.60.01.D 1x6,0 7,0 56 77CF330.100.01.D 1x10,0 8,0 96 119CF330.160.01.D 1x16,0 9,5 151 183CF330.250.01.D 1x25,0 11,5 239 281CF330.350.01.D 1x35,0 12,5 333 377CF330.500.01.D 1x50,0 14,5 479 525CF330.700.01.D 1x70,0 16,0 623 676CF330.950.01.D 1x95,0 19,0 848 927CF330.1200.01.D 1x120,0 21,5 1059 1145CF330.1500.01.D 1x150,0 23,0 1318 1411CF330.1850.01.D 1x185,0 27,0 1890 2014Tel. +49-2203-96 49-0Fax +49-2203-96 49-222(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF330.160.01.D – in your desired length (0,5 m steps)CF330.D <strong>Chainflex</strong> ® series .160 Code nominal cross section .01 Number of coresPlease use www.chainflex.eu/en/CF330 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF330(for up to 10 cuts of the same type)203


CF340TPE7,5 x dHighly flexiblespecial conductorTPE power cable<strong>Chainflex</strong> ® CF340● for maximum load requirements● TPE outer jacket● shielded● oil- and bio-oil-resistant● PVC-free/halogen-free● UV-resistant● hydrolysis-resistant and microbe-resistantTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +90 °C, minimum bending radius 7,5 x d-40 °C to +90 °C, minimum bending radius 4 x d10 m/s, 6 m/sa max. 100 m/s 2Travel distanceUV-resistantFreely suspended and gliding travel distances up to 400 mand more, Class 4HighNominal voltage 600/1000 V (following DIN VDE 0250).Pressure extrudedTPE blendTesting voltage 4000 V (following DIN VDE 0281-2).Highly flexiblebraided coppershieldOilSilicon-freeOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Pressure extrudedTPE blendConductor Conductor cable consisting of pre-leads (following EN 60228).Core insulationMechanically high-quality TPE mixture.Class 7.4.4Overall shieldOuter jacketCELead freeClean roomExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® .Colour: Jet black (similar to RAL 9005)Following 2006/95/ECFollowing 2002/95/EC (RoHS).According to ISO Class 1. Outer jacket material complies withCF34.UL.25.04.D, tested by IPA according to standard 14644-1204Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.4.4Price indexCF340TPE7,5 x dTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, ship to shore, outdoor cranes, low-temperature applicationsPower cableDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CF340.40.01 (1x4,0)C 6,5 55 74CF340.60.01 (1) (1x6,0)C 7,5 75 97CF340.100.01 (1) (1x10,0)C 8,5 120 144CF340.160.01 (1x16,0)C 10,0 178 210CF340.250.01 (1) (1x25,0)C 11,5 272 314CF340.350.01 (1) (1x35,0)C 13,5 380 423CF340.500.01 (1x50,0)C 15,0 524 568CF340.700.01 (1x70,0)C 17,5 689 748CF340.950.01 (1) (1x95,0)C 20,5 920 1072CF340.1200.01 (1x120,0)C 22,0 1140 1233CF340.1500.01 (1x150,0)C 24,0 1436 1549CF340.1850.01 (1x185,0)C 28,0 2020 2147Tel. +49-2203-96 49-0Fax +49-2203-96 49-222(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreOrder example: CF340.100.01 – in your desired length (0,5 m steps)CF340 <strong>Chainflex</strong> ® series .100 Code nominal cross section .01 Number of coresPlease use www.chainflex.eu/en/CF340 for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CF340(for up to 10 cuts of the same type)205


CF FLATTPE5 x dHighly flexible braidedspecial conductorNew! TPE Power cable<strong>Chainflex</strong> ® CF FLAT● for maximum load requirements● TPE outer jacket● oil-resistant● bio-oil-resistant● PVC-free/halogen-free● UV-resistant● hydrolysis-resistant and microbe-resistantTemperature rangemoved-35 °C to +100 °C, minimum bending radius 5 x dTemperature rangefixed-40 °C to +100 °C, minimum bending radius 4 x dv max.unsupported/gliding 10 m/s, 6 m/sa max. 100 m/s 2Travel distanceUV-resistantFreely suspended and gliding travel distances up to 400 mand more, Class 4.HighNominal voltage 600/1000 V (following DIN VDE 0250)Testing voltage 4000 V (following DIN VDE 0281-2)Pressure extrudedTPE blendOilOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1Pressure extrudedTPE blendConductorCore insulationHighly flexible braided special conductorMechanically high-quality TPE mixture.Outer jacketCELow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® . Colour: Steel blue (similar to RAL 5011)Following 2006/95/ECClass 7.4.4Lead freeClean roomFollowing 2002/95/EC (RoHS)According to ISO Class 1. Outer jacket material complies withCF34.UL.25.04.D, tested by IPA according to standard 14644-1206Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.4.4Price indexCF FLATTPE5 x dTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren Storage and retrieval units for high-bay warehouses, tight design space, small radii, machining units/machine tools,quick handling, clean room, semiconductor insertion, low-temperature applicationsPower cableDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CFFLAT.25.01 1x2,5 13,5 x 5,0 30 71CFFLAT.40.01 1x4,0 14,0 x 5,0 46 109Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Order example: CFFLAT.25.01 – in your desired length (0,5 m steps)CFFLAT <strong>Chainflex</strong> ® series .25 Code nominal cross section .01 Number of coresPlease use www.chainflex.eu/en/CFFLAT for your online order.NewNewTel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFFLAT(for up to 10 cuts of the same type)207


CFBRAIDTPE7,5 x dHighly flexiblespecial conductorTPE Power cable<strong>Chainflex</strong> ® CF BRAID● for maximum load requirements● TPE outer jacket● unshielded/shielded● oil- and bio-oil-resistant● flame-retardant● UV-resistant● hydrolysis-resistant and microbe-resistantTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +70 °C, minimum bending radius 7,5 x d-40 °C to +70 °C, minimum bending radius 4 x d10 m/s, 6 m/sa max. 80 m/s 2Cores braidedtogether usinga special techniqueTravel distanceUV-resistantFreely suspended and gliding travel distances up to 400 mand more, Class 4HighNominal voltage 600/1000 V (following DIN VDE 0250).Testing voltage 4000 V (following DIN VDE 0281-2).TPE Inner jacketOilOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Highly flexiblebraided coppershieldPressure extrudedTPE blendFlame-retardantAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).ConductorFine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Core insulation Mechanically high-quality TPE mixture (following DIN VDE 0207Part 4).Core strandingCore identificationCores braided together using a special technique.Cores black with white numerals, one core green-yellow.Class 6.4.4208Image exemplary.Inner jacket TPE mixture adapted to suit the requirements in Energy Chains ®(for shielded types).Overall shield Extremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical (for shieldedtypes).Outer jacketLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® .Colour: Jet black (similar to RAL 9005)... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.4Price indexCFBRAIDTPE7,5 x dCEFollowing 2006/95/ECCEI Following CEI 20-35Lead freeFollowing 2002/95/EC (RoHS).Clean roomAccording to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, testedby IPA according to standard 14644-1Power cableTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 m and moren Storage and retrieval units for high-bay warehouses, quick handling, in- and outdoor cranes, low-temperature applicationsWhat is special about CF BRAID?Due to their unique type of design and especially in the case of cross-sections ≥ 0,5 mm 2 and long distances of travelwith large numbers of cycles, <strong>cables</strong> with 7 cores have an increased tendency toward the formation of corkscrews. Dueto the special design of the CF BRAID with 8 braided cores, corkscrews can be completely ruled out.Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CFBRAID.25.08 8 G 2,5 20,0 192 398CFBRAID.25.08.C (8) (8 G 2,5)C 23,5 320 625(8) without DesinaNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Order example: CFBRAID.25.08 – in your desired length (0,5 m steps)CFBRAID <strong>Chainflex</strong> ® series .25 Code nominal cross section .08 Number of coresPlease use www.chainflex.eu/en/CFBRAID for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFBRAID (for up to 10 cuts of the same type)209


CF CRANEiguprene10 x digupren Power cable<strong>Chainflex</strong> ® CF CRANE● for maximum voltages and outputs● iguprene outer jacket● oil-resistant● flame-retardantHighly flexiblespecial conductorTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-20 °C to +80 °C, minimum bending radius 10 x d-30 °C to +80 °C, minimum bending radius 7,5 x d10 m/s, 6 m/sa max. 50 m/s 2Travel distanceFreely suspended and gliding travel distances up to 500 mand more, Class 4UV-resistantHighExtruded EPRinsulation overconductive rubberNominal voltage 6/10 kV (following DIN VDE 0250),other voltages upon inquiry.Testing voltage 17 kV (following DIN VDE 0250, part 813).Oil Oil-resistant (following EN 60811-2-1), Class 3Highly flexibleoverall coppershieldExtruded, highlyabrasionresistantiguprenejacket blendClass 6.4.3Flame-retardantSilicon-freeConductorCore insulationOverall shieldOuter jacketCELead freeAccording to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Highly flexible cable consisting of tinned copper wires(following VDE 0295).Inner and outer semiconducting layer made of conductiverubber. Insulating sheath made of high-quality, heat-resistantand ozone-proof ethylene propylene rubber (EPR).Extremely bending-resistant, tinned copper shield.Coverage approx. 80% optical.Low-adhesion mixture on the basis of iguprene, especiallyabrasion-resistant and highly flexible, adapted to suit the require -ments in Energy Chains ® (following DIN VDE 0207 Part 21).Colour: redFollowing 2006/95/ECFollowing 2002/95/EC (RoHS).210Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.4.3Price indexCF CRANEiguprene10 x dTypical application arean for maximum load requirementsn almost unlimited resistance to oiln indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 500 m and moren outdoor ship to shore, crane applications, conveyer technologyPower cableDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CFCRANE1x25/16-6/10kV (1) (1 x 25/16)C 27,0 468 940CFCRANE1x35/16-6/10kV (1) (1 x 35/16)C 29,0 576 1110CFCRANE1x50/16-6/10kV (1) (1 x 50/16)C 30,0 712 1350CFCRANE1x70/16-6/10kV (1) (1 x 70/16)C 32,0 912 1550CFCRANE1x95/16-6/10kV (1) (1 x 95/16)C 34,0 1145 1820(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Order example: CFCRANE1x25/16-6/10kV – in your desired length (0,5 m steps)CFCRANE <strong>Chainflex</strong> ® series .1 x 25/16 Code nominal cross section -6/10 Nominal voltagePlease use www.chainflex.eu/en/CFCRANE for your online order.Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery time 24h or today** Delivery time means time until shipping of goods<strong>Chainflex</strong> ® CFCRANE for 500 m and more of travel. E-Chain ® : igus ® Rol E-Chain ®950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFCRANE (for up to 10 cuts of the same type)211


CFAIRPU10 x dPneumatic hose<strong>Chainflex</strong> ® CFAIR● for maximum load requirements● PU hose● oil-resistant and coolant-resistant● abrasion-resistant● outside-toleranced● halogen-freeTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-20 °C to +80 °C, minimum bending radius 10 x d-40 °C to +85 °C, minimum bending radius 8 x d10 m/s, 6 m/sa max. 50 m/s 2DimensionsOutside-tolerancedOperating pressure 12 bar at 20 °CVacuum -1 bar at 20 °COilOil-resistant.Halogen-free Following EN 50267-2-1.MaterialAbrasion-resistant on the basis of Polyurethan adapted to suit therequirements in Energy Chains ® .Colour: blueLead freeFollowing 2002/95/EC (RoHS).212Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Price indexCFAIRPU10 x dDelivery programPart No.Max. packagelength[km]Internaldiameterapprox. [mm]Wallthicknessapprox. [mm]Externaldiameterapprox. [mm]Weight[g/m]CA PU.A.04.0 2,0 2,7 0,65 4 8CA PU.A.06.0 1,5 4,0 1,00 6 19CA PU.A.08.0 1,0 5,7 1,15 8 30CA PU.A.10.0 1,0 7,0 1,50 10 48CA PU.A.12.0 0,5 8,0 2,00 12 76CA PU.A.16.0 0,1 11,0 2,50 16 127Pneumatic hoseOrder example: CA PU.A.04.0 – in your desired length (0,5 m steps)CA PU <strong>Chainflex</strong> ® series .A Code material .04 Code Ø .0 Special identificationPlease use www.chainflex.eu/en/CAPU for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® <strong>Chainflex</strong> ® CFAIR pneumatic hoses were tested over several million bending cycles in E-Chains ® . Their outstanding features includeflexibility, high abrasion resistance and very good resistance to oil and coolants.950 types from stock no cutting costs ...... and order online www.igus.eu/en/CAPU(for up to 10 cuts of the same type)213


CF Clean AIRPE10 x dPneumatic hose<strong>Chainflex</strong> ® CF Clean AIR● for maximum load requirements● PE hose● oil-resistant and coolant-resistant● highly abrasion-resistant● outside-toleranced● halogen-freeTemperature rangemoved-25 °C to +60 °C, minimum bending radius 10 x dTemperature rangefixed-30 °C to +65 °C, minimum bending radius 8 x dv max.unsupported/gliding 10 m/s, 6 m/sa max. 50 m/s 2DimensionsOutside-tolerancedOperating pressure 10 bar at 20 °CVacuum -0.95 bar at 20 °COilOil-resistant.Halogen-free Following EN 50267-2-1.MaterialLead freeHighly abrasion-resistant on the basis of Polyethylen adaptedto suit the requirements in Energy Chains ® . Colour: whiteFollowing 2002/95/EC (RoHS).Clean roomAccording to ISO Class 1, material/cable tested by IPA accordingto ISO standard 14644-1Typical application arean for especially high abrasion resistancen clean room, semi-conductor industry, handling214Image exemplary.igus ® material abrasion test... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Price indexCF Clean AIRPE10 x dDelivery programPart No.Max. packagelength[km]Internaldiameterapprox. [mm]Wallthicknessapprox. [mm]Externaldiameterapprox. [mm]Weight[g/m]CA PE.A.04.0 2,0 2,7 0,65 4 6CA PE.A.06.0 1,5 4,0 1,00 6 15CA PE.A.08.0 1,0 5,7 1,15 8 21CA PE.A.10.0 1,0 7,0 1,50 10 38CA PE.A.12.0 0,5 8,0 2,00 12 54CA PE.A.16.0 0,1 11,0 2,50 16 90Pneumatic hoseOrder example: CA PE.A.04.0 – in your desired length (0,5 m steps)CA PE <strong>Chainflex</strong> ® series .A Code material .04 Code Ø .0 Special identificationPlease use www.chainflex.eu/en/CAPE for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTel. +49-2203-96 49-0Fax +49-2203-96 49-222Comparison: abrasion of pneumatic hoses PUR, PE and PA in combination with igus ® E-Chains ® *Abrasion in mmPUR hosePE hose 10x 1,5PA hoseDouble strokes* igus ® E-Chain ® with opening link 450.30950 types from stock no cutting costs ...... and order online www.igus.eu/en/CAPE(for up to 10 cuts of the same type)215


obotwistable <strong>cables</strong>


<strong>Chainflex</strong> ®cableJacketShield<strong>Chainflex</strong> ®Minimum bendingradius, moved[factor x d]Temperaturemovedfrom/to [°C]TypenApprovals andstandardsOil-resistantTorsion resistantv max. [m/s]unsupportedv max. [m/s]glidinga max. [m/s 2 ]PageTwistable <strong>cables</strong>Hybrid cable/Control cableCFROBOT9 PUR ✔ 10,0 -25/ +80 ✔ ✔ 10 10 220Bus cableCFROBOT8 PUR ✔ 10,0 -20/ +70 ✔ ✔ 10 10 222Measuring system cableCFROBOT4 PUR ✔ 10,0 -25/ +80 ✔ ✔ 10 10 224Fibre optic cableCFROBOT5 TPE 12,5 -20/ +60 ✔ ✔ 10 10 226Power cable/Servo cableCFROBOT6 PUR 10,0 -25/ +80 ✔ ✔ 10 10 228CFROBOT7 PUR ✔ 10,0 -25/ +80 ✔ ✔ 10 10 228CFROBOT TPE ✔ 10,0 -35/ +100 ✔ ✔ 10 10 230217


Info<strong>Chainflex</strong> ® <strong>cables</strong> for robotsEver more complex sequences of movements in indus trialapplications demand twistable and/or three-dimensionalflexible <strong>cables</strong> with a long service life similar to the classic<strong>Chainflex</strong> ® <strong>cables</strong> for use in linear E-ChainSystems ® .Wires, stranded, shields and sheathing materials mustcompensate both major changes in bending load andchanges in diameter due to torsional movements.For this purpose, different "soft" structural elements e.g.rayon fibres, PTFE elements or filling elements that absorbtorsion forces are used in <strong>Chainflex</strong> ® ROBOT <strong>cables</strong>.Special demands are made on the braided shielding intorsion <strong>cables</strong>. Torsion-optimised shield structures arechosen that can carry out the necessary compensatorymovements thanks to special PTFE gliding films.With twistable bus <strong>cables</strong> in particular, the transmissioncharacteristics such as attenuation, cable capacity andsignal quality must remain within very tight tolerance rangesover the whole service life.This is achieved through the use of particularly torsionoptimisedinsulating materials and mechanical attenuationelements with matching capacity values.The highly abrasion-resistant, halogen-free and flameresistantPUR sheathing mixture in motor, hybrid/control<strong>cables</strong> and bus <strong>cables</strong> protects the torsion-optimisedstranded elements from possible damage.The highly abrasion-resistant, halogen-free TPE-sheathmixture matches the special requirements of the twistableFOC and individual wires, and also protects the strandedelements.Unlike <strong>cables</strong> for linear E-ChainSystems ® , the "mechanicalstress" for these <strong>cables</strong> is in the combination of bending,torsion and centrifugal forces that cannot usually be determinedby design in advance or during use by means ofmeasurement.For this reason, and unlike the situation with linear E-Chain ® applications, a clear "yes/no" statement cannotbe made about the possibility of using a certain cable intorsion applications.To enable evaluation to take place nevertheless, based onsensible and comparable test results, the igus ® "torsiontest standard" was developed.According to this standard, all <strong>Chainflex</strong> ® ROBOT <strong>cables</strong>of a Triflex ® R Energy Chain ® are twisted with a fixed-pointdistance of one metre and a torsion of +/- 180° at least3 million times. In addition, a test is carried out on a testbench with a chain length of approx. 2500 mm with 270°torsion with an extreme load through centrifugal forcesand heavy blows such as those that can occur with anindustrial robot.All the non-shielded, gusset-filled extruded standard<strong>Chainflex</strong> ® control <strong>cables</strong> of the series CF5, CF77.UL.D andCF 9 correspond to the above-mentioned igus ® standardand have been approved for use in torsion applications.The following twistable CF ROBOT cable types are currentlyavailable:n Hybrid/control <strong>cables</strong>n Motor/servo <strong>cables</strong>n Bus/data <strong>cables</strong>n FOC <strong>cables</strong>We can also offer you <strong>Chainflex</strong> ® ROBOT <strong>cables</strong> pre-fittedwith the plug-in connectors of your choice as ReadyCable ® ,or as a ready-to-install ReadyChain ® cable assembly.218... no minimum order quantity


InfoTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®950 types from stock no cutting costs ...(for up to 10 cuts of the same type)219


CFROBOT9PUR± 180°Highly flexiblespecial conductorConductor twisted withdampening elementsExtremely torsionresistant coppershieldPUR Hybrid cable, twistable<strong>Chainflex</strong> ® CF ROBOT9● for twistable loads● PUR outer jacket● unshielded/shielded● oil-resistant and coolant-resistant● notch-resistant● flame-retardant● hydrolysis-resistant and microbe-resistantTemperature range -25 °C to +80 °C, minimum bending radius twisted 10 x dmovedTemperature range -40 °C to +80 °C, minimum bending radius 4 x dfixedv max.10 m/stwisteda max. 10 m/s 2Travel distance Robots and movements in the 3D range, Class 1Torsion± 180 °, with 1 m cable lengthUV-resistantHighNominal voltage 300/500 V (following DIN VDE 0245).Testing voltage 2000 V (following DIN VDE 0281-2).PTFE gliding foilOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363 -10-2), Class 3.Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Pressure extrudedPUR blendSilicon-freeConductorCore insulationFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 192).Extremely bend-resistant cableMechanically high-quality TPE mixture.Class 6.1.3220Image exemplary.Element shield Extremely torsion resistant, tinned braided copper shield.Coverage approx. 85% optical.Outer jacketLow-adhesion, halogen-free, highly abrasion-resistant mixture onthe basis of PUR, adapted to suit the requirements in EnergyChains ® (following DIN VDE 0282 Part 10).Colour: Steel blue (similar to RAL 5011)CEI Following CEI 20-35CELead freeFollowing 2006/95/ECFollowing 2002/95/EC (RoHS).... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.1.3Price indexCFROBOT9PUR± 180°Clean roomAccording to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D,tested by IPA according to standard 14644-1Typical application arean for maximum load requirements with torsion movementsn almost unlimited resistance to oiln indoor and outdoor applications, UV-resistantn especially for robots and movements in the 3D rangen Robots, handling, spindle drivesRobot cableDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CFROBOT9.001 5 G 1,0 + (2x1,0)C 9,5 75 129CFROBOT9.002 2x3x0,75 + (3x0,75)C 12,0 76 143CFROBOT9.003 2x0,5 + (2x0,5)C 10,0 27 75CFROBOT9.004 16 G 1,0 + (2x1,0)C 18,5 177 326CFROBOT9.005 (1) 23 G 1,0 + (2x1,0)C 19,5 241 478CFROBOT9.006 24 G 1,0 + (2x1,0)C 20,0 251 484CFROBOT9.007 (15x(2x0,25)C + (4x0,25)C)C 18,0 217 330(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreNewTel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery program Number of cores and Core groupPart No.conductor nominalcross section [mm 2 ]CFROBOT9.001 5 G 1,0 + (2x1,0)C 5G1,0(2x1,0)CCFROBOT9.002 6 G 0,75 + (3x0,75)C 6G0,75(3x0,75)CCFROBOT9.003 2 G 0,5 + (2 x 0,5)C 2x0,5(2x0,5)CCFROBOT9.004 16 G 1,0 + (2x1,0)C 16G1,0(2x1,0)CCFROBOT9.005 23 G 1,0 + (2x1,0)C 23G1,0(2x1,0)CCFROBOT9.006 24 G 1,0 + (2x1,0)C 24G1,0(2x1,0)CCFROBOT9.007 (15x(2x0,25)C + (4x0,25)C)C 15x(2x0,25)C(4x0,25)CColour codeCores black with white numerals 1-4, one core green-yellowCores black with white numerals 5-6Cores black with white numerals 1-5, one core green-yellowCores black with white numerals 6-8Cores black with white numerals 1-2Cores black with white numerals 3-4Cores black with white numerals 1-4, 7-17, one core green-yellowCores black with white numerals 5-6Cores black with white numerals 1-4, 7-24, one core green-yellowCores black with white numerals 5-6Cores black with white numerals 1-4, 7-25, one core green-yellowCores black with white numerals 5-6Colour code in accordance with DIN 47100white, green, brown, yellow (CAN-Bus)Order example: CFROBOT9.001 – in your desired length (0,5 m steps)CFROBOT9 <strong>Chainflex</strong> ® series .001 Code nominal cross sectionPlease use www.chainflex.eu/en/CFROBOT for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFROBOT(for up to 10 cuts of the same type)221


CFROBOT8PUR± 180°Especially bendingresistant fine-wirestranded conductorCores each strandedin especially shortoptimized pitchGRP core elementGusset-filled extrudeddampening elementsPUR Bus cable, twistable<strong>Chainflex</strong> ® CF ROBOT8● for twistable loads● PUR outer jacket● shielded● oil-resistant● notch-resistant● flame-retardant● hydrolysis-resistant and microbe-resistantTemperature range -20 °C to +70 °C, minimum bending radius twisted 10 x dmovedTemperature range -25 °C to +70 °C, minimum bending radius 7,5 x dfixedv max.10 m/stwisteda max. 10 m/s 2Travel distance Robots and movements in the 3D range, Class 1PTFE gliding foilTorsionUV-resistant± 180 °, with 1 m cable lengthHighNominal voltage30 VTesting voltage500 VTorsion resistantcopper shieldOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363 -10-2),Class 3.Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Highly abrasionresistantPURjacket blendSilicon-freeConductorCore insulationFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 192).Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).According to bus specificationCore strandingAccording to bus specificationClass 6.1.3Core identification According to bus specificationDelivery programIntermediate jacket Foil taping over the external layer.Overall shield Torsion resistant tinned braided copper shield.Coverage approx. 80% optical.Outer jacketLow-adhesion, highly abrasion-resistant mixture on the basisof PUR, adapted to suit the requirements in Energy Chains ® .Colour: Steel blue (similar to RAL 5011)CEI Following CEI 20-35222Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.1.3Price indexCFROBOT8PUR± 180°CEFollowing 2006/95/ECLead freeFollowing 2002/95/EC (RoHS).Typical application arean for maximum load requirements with torsion movementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for robots and movements in the 3D rangen Robots, handling, spindle drivesRobot cableDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]CFROBOT8.001 (Profibus) (2x0,35)C 8,0 22 57CFROBOT8.022 (Can-Bus) (4x0,5)C 7,0 39 65CFROBOT8.045 (GigE) (4x(2x0,14)C) 8,5 35 65Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreTel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery program Characteristic Number of cores andPart No.wave impedanceconductor nominalapprox. [Ω] cross section [mm 2 ]CFROBOT8.001 150 (2x0,35)CCFROBOT8.022 120 (4x0,5)CCFROBOT8.045 100 (4x(2x0,14)C)Colour codered, greenwhite, green, brown, yellow (star-quad stranding)white-blue/blue, white-orange/orange, white-green/green,white-brown/brownOrder example: CFROBOT8.001 – in your desired length (0,5 m steps)CFROBOT8 <strong>Chainflex</strong> ® series .001 Code nominal cross sectionPlease use www.chainflex.eu/en/CFROBOT for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFROBOT(for up to 10 cuts of the same type)223


CFROBOT4PUR± 180°Highly flexible specialconductorConductor twisted withdampening elementsExtremely torsionresistant coppershieldNEW! PUR Measuring system cable, twistable<strong>Chainflex</strong> ® CF ROBOT4● for twistable loads● PUR outer jacket● shielded● oil-resistant and coolant-resistant● notch-resistant● flame-retardant● hydrolysis-resistant and microbe-resistantTemperature range -25 °C to +80 °C, minimum bending radius twisted 10 x dmovedTemperature range -40 °C to +80 °C, minimum bending radius 4 x dfixedv max.10 m/stordierta max. 10 m/s 2Travel distance Robots and movements in the 3D range, Class 1.Torsion± 180°, with 1 m cable lengthUV-resistantHighNominal voltage30 VTesting voltage500 VExtremely torsionresistant coppershieldOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2),Class 3.Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1Pressure extrudedPUR blendSilicon-freeConductorCore insulationFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Extremely bend-resistant cableMechanically high-quality TPE mixture.Class 6.1.3224Abbildung exemplarisch.Element shield Extremely torsion resistant tinned braided copper shield.Coverage approx. 85% optical.Outer jacketLow-adhesion, halogen-free, highly abrasion-resistant mixtureon the basis of PUR, adapted to suit the requirements inEnergy Chains ® (following DIN VDE 0282 Part 10).Colour: Steel blue (similar to RAL 5011)CEI Following CEI 20-35CELead freeFollowing 2006/95/ECFollowing 2002/95/EC (RoHS)... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.1.3Price indexCFROBOT4PUR± 180°Clean roomAccording to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D,tested by IPA according to standard 14644-1Typical application arean for maximum load requirements with torsion movementsn almost unlimited resistance to oiln indoor and outdoor applications, UV-resistantn especially for robots and movements in the 3D rangen Robots, handling, spindle drivesRobot cableDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]Weight[kg/km]CFROBOT4.001(3x(2x0,14)C+(4x0,14) + (2x0,5))C 11,0 65 166CFROBOT4.002 (1) (3x(2x0,14)C + 2x(0,5)C)C 10,5 67 128CFROBOT4.009 (4x(2x0,25) + (2x0,5))C 9,0 53 102CFROBOT4.015 (1) (4x(2x0,14) + 4x0,5)C 9,0 54 106CFROBOT4.028 (1) (2x(2x0,15) + (2x0,38))C 7,5 42 72(1) Delivery time upon inquiryNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreNewNewNewNewNewTel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery program Number of cores and Core groupPart No.conductor nominalcross section [mm 2 ]CFROBOT4.001 (3x(2x0,14)C + (4x0,14) + (2x0,5))C 3x(2x0,14)C4x0,142x0,5CFROBOT4.002 (3x(2x0,14)C + 2x(0,5)C)C 3x(2x0,14)C2x(0,5)CCFROBOT4.009 (4x(2x0,25) + (2x0,5))C 4x(2x0,25)2x0,5CFROBOT4.015 (4x(2x0,14) + 4x0,5)C 4x(2x0,14)4x0,5CFROBOT4.028 (2x(2x0,15) + (2x0,38))C 2x(2x0,15)(2x0,38)Colour codeyellow/green, black/brown, red/orangegray, blue, white-yellow, white-blackbrown-red, brown-bluegreen/yellow, black/brown, red/orangeblack, redbrown/green, blue/violet, gray/pink, red/blackwhite, brownbrown/green, violet/yellow, gray/pink, red/blackblue, white, brown-green, white-greengreen/yellow, pink/bluered, blackOrder example: CFROBOT4.009 – in your desired length (0,5 m steps)CFROBOT4 <strong>Chainflex</strong> ® series .009 Code nominal cross sectionPlease use www.chainflex.eu/en/CFROBOT for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFROBOT(for up to 10 cuts of the same type)225


CFROBOT5TPE± 180°FOC cores with hightensilearamide fibresTPE-Fibre optic cable, twistable<strong>Chainflex</strong> ® CF ROBOT5● for twistable loads● TPE outer jacket● oil-resistant● bio-oil-resistant● UV-resistant● low-temperature-flexible● hydrolysis-resistant and microbe-resistantGRP core elementTemperature range -20 °C to +60 °C, minimum bending radius twisted 12,5 x dmovedTemperature range -25 °C to +60 °C, minimum bending radius 7,5 x dfixedv max.10 m/stwisteda max. 10 m/s 2Travel distance Robots and movements in the 3D range, Class 1FOC wires strandedwith dampers aroundthe GRP coreTorsionUV-resistant± 180 °, with 1 m cable lengthHighPressure extruded,halogen-free TPE blendOilSilicon-freeFibre optic cableCore strandingOuter jacketCEOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 192).50/125 µm, 62.5/125 µm special fixed wire elements witharamide strain relief.FOC wires stranded with high-tensile aramide dampersaround the GRP central element.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® .Following 2006/95/ECLead freeFollowing 2002/95/EC (RoHS).Clean roomAccording to ISO Class 1. Outer jacket material complies withCF9.15.07, tested by IPA according to standard 14644-1Class 7.1.4226Image exemplary.Typical application arean for maximum load requirements with torsion movementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for robots and movements in the 3D rangen Robots, handling... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 7.1.4Price indexCFROBOT5TPE± 180°Delivery programPart No.Number of fibres Fibrediameterapprox. [µm]Externaldiameterapprox. [mm]Weight[kg/km]CFROBOT5.500 2 62,5/125 8,5 87CFROBOT5.501 2 50/125 8,5 87Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.Robot cableDelivery programPart No.Bandwidthwith 850 nm[MHz x km]Attenuationwith 850 nm[dB/km]Bandwidthwith 1300 nm[MHz x km]Attenuationwith 1300 nm[dB/km]Colour codeCFROBOT5.500 160 - 200 3,2 200 - 500 0,9 blue with white numbersCFROBOT5.501 200 - 600 2,5 - 3,5 600 - 1200 0,7 - 1,5 blue with white numbersOrder example: CFROBOT5.501 – in your desired length (0,5 m steps)CFROBOT5 <strong>Chainflex</strong> ® series .501 Code type of fibresPlease use www.chainflex.eu/en/CFROBOT for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFROBOT(for up to 10 cuts of the same type)227


CFROBOT6/7PUR± 180°Highly flexiblespecialconductorPUR Motor cable, twistable<strong>Chainflex</strong> ® CF ROBOT6/7● for twistable loads● PUR outer jacket● unshielded/shielded● oil-resistant and coolant-resistant● notch-resistant● flame-retardant● hydrolysis-resistant and microbe-resistantConductortwisted withdampeningelementsTemperature range -25 °C to +80 °C, minimum bending radius twisted 10 x dmovedTemperature range -40 °C to +80 °C, minimum bending radius 4 x dfixedv max.10 m/stwisteda max. 10 m/s 2Travel distance Robots and movements in the 3D range, Class 1Torsion± 180 °, with 1 m cable lengthUV-resistantHighNominal voltage 600/1000 V (following DIN VDE 0250).Testing voltage 4000 V (following DIN VDE 0281-2).Extremely torsionresistant coppershieldOil Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363 -10-2),Class 3.Flame-retardant According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.PTFE gliding foilPressureextrudedPUR blendSilicon-freeConductorCore insulationFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 192).Extremely bend-resistant cableMechanically high-quality TPE mixture.Class 6.1.3Core identificationOverall shieldOuter jacketEnergy conductor: cores black with white numerals, onecore green/yellow Schedule delivery program2 control pairs: cores black with white numerals.1. control core: 5 2. control core: 63. control core: 7 4. control core: 84 control pairs: colour code in accordance with DIN 47100Extremely torsion resistant, tinned braided copper shield.Coverage approx. 85% optical.Low-adhesion, halogen-free, highly abrasion-resistant mixture onthe basis of PUR, adapted to suit the requirements in EnergyChains ® (following DIN VDE 0282 Part 10).Colour: Steel blue (similar to RAL 5011)228Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.1.3Price indexCFROBOT6/7PUR± 180°CEI Following CEI 20-35CELead freeClean roomFollowing 2006/95/ECFollowing 2002/95/EC (RoHS).According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D,tested by IPA according to standard 14644-1Robot cableTypical application arean for maximum load requirements with torsion movementsn almost unlimited resistance to oiln indoor and outdoor applications, UV-resistantn especially for robots and movements in the 3D rangen Robots, handling, spindle drivesDelivery programNumber of cores and External Copper WeightPart No.conductor nominal diameter index [kg/km]cross section [mm 2 ] approx. [mm] [kg/km]CFROBOT6.100.03 (12) 3 G 10 16,5 287 404CFROBOT6.160.03 (12) 3 G 16 19,0 459 601CFROBOT6.250.03 (12) 3 G 25 23,5 722 926CFROBOT6.350.03 (12) 3 G 35 26,0 1020 1233Without control pairCFROBOT7.15.03.C (12) (3 G 1,5)/C 8,0 58 95CFROBOT7.25.03.C (12) (3 G 2,5)/C 9,5 89 137CFROBOT7.15.04.C (13) (4 G 1,5)/C 8,5 74 121CFROBOT7.25.04.C (13) (4 G 2,5)/C 10,5 115 1712 control pairsCFROBOT7.15.15.02.02.C (14) (4 G 1,5 + 2x(2x1,5)C)C 16,5 190 380CFROBOT7.25.15.02.02.C (1/14) (4 G 2,5 + 2x(2x1,5)C)C 18,5 230 4504 control pairsCFROBOT7.40.02.02.04.C (14) (4 G 4 + 4x(2x0,25)C)C 16,5 240 340(1) Delivery time upon inquiry(12) Core identification energy conductor: 1. Core: 1 2. Core: 2(13) Core identification energy conductor: 1. Core: 1 2. Core: 2 3. Core: 3(14) Core identification energy conductor: 1. Core: U / L1 / C / L+ 2. Core: V / L2 3. Core: W / L3 / D / L-Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreNewNewNewTel. +49-2203-96 49-0Fax +49-2203-96 49-222Order example: CFROBOT6.100.03 – in your desired length (0,5 m steps)CFROBOT6 <strong>Chainflex</strong> ® series .100 Code nominal cross section .03 Number of coresPlease use www.chainflex.eu/en/CFROBOT for your online order.Delivery time 24h or today** Delivery time means time until shipping of goods950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFROBOT(for up to 10 cuts of the same type)229


CF ROBOTTPE± 90°Extremely bendresistantcablePressure extrudedTPE blendTPE-Robot cable<strong>Chainflex</strong> ® CF ROBOT● for twistable loads● TPE outer jacket, shielded● oil-resistant● bio-oil-resistant● PVC-free● UV-resistant● flame-retardant● hydrolysis-resistant and microbe-resistantExtremely strongrayon threadTemperature range -35 °C to +100 °C, minimum bending radius twisted 10 x dmovedTemperature range -40 °C to +100 °C, minimum bending radius 4 x dfixedv max.10 m/stwisteda max. 10 m/s 2PTFE gliding foilTravel distance Robots and movements in the 3D range, Class 1Torsion± 90 °, with 1 m cable lengthUV-resistantHighExtremely torsionresistant coppershieldNominal voltage 600/1000 V (following DIN VDE 0250).Testing voltage 4000 V (following DIN VDE 0281-2).Extremely strongrayon threadOilFlame-retardantOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Pressure extrudedTPE blendSilicon-freeConductorFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 192).Extremely bend-resistant cableCore insulationMechanically high-quality TPE mixture.Class 6.1.4Overall shield Extremely torsion resistant tinned braided copper shield.Coverage approx. 90% optical.Outer jacketLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® .Colour: Jet black (similar to RAL 9005)UL/CSA Style 10258 and 21387, 1000 V, 90 °CCEI Following CEI 20-35230Image exemplary.CEFollowing 2006/95/EC... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Class 6.1.4Price indexCF ROBOTTPE± 90°Lead freeFollowing 2002/95/EC (RoHS).Clean roomTypical application arean for maximum load requirements with torsion movementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for robots and movements in the 3D rangen Robots, handling, spindle drivesAccording to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, testedby IPA according to standard 14644-1Robot cableDelivery programPart No.Number of cores andconductor nominalcross section [mm 2 ]Externaldiameterapprox. [mm]Copperindex[kg/km]CFROBOT.035 (1x10,0)C 10,5 121 197CFROBOT.036 (1x16,0)C 12,0 183 274CFROBOT.037 (1x25,0)C 14,5 289 425CFROBOT.038 (1x35,0)C 15,5 391 534CFROBOT.039 (1x50,0)C 18,0 546 726Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreWeight[kg/km]Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Order example: CFROBOT.035 – in your desired length (0,5 m steps)CFROBOT <strong>Chainflex</strong> ® series .035 Code nominal cross sectionPlease use www.chainflex.eu/en/CFROBOT for your online order.Delivery time 24h or today** Delivery time means time until shipping of goodsigus ® <strong>Chainflex</strong> ® <strong>cables</strong> in application of a multi-dimensional moving energy chain Triflex ® R for production robots.950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFROBOT(for up to 10 cuts of the same type)231


ameraideo-, vision engineering/bus technology


<strong>Chainflex</strong> ® ReadyCable ®Cable type Jacket PageVideo-, vision engineering/bus technology (with camera reference list page 224)FireWire Ready-made cable TPE 234USB Ready-made cable TPE 238GigE Ready-made cable TPE 242FOC Ready-made cable PUR 244FOC Ready-made cable (Robotics) TPE 248Koax Ready-made cable TPE 250233


FireWireTPE12,5 x dTPE Bus cable<strong>Chainflex</strong> ® FireWire● FireWire cable (IEEE 1394a)● for maximum load requirements● TPE outer jacket● oil-resistant● flame-retardantTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +70 °C, minimum bending radius 12,5 x d-40 °C to +70 °C, minimum bending radius 5 x d10 m/s, 6 m/sa max. 100 m/s 2Especially bendingresistantfine-wirestranded conductorUV-resistantNominal voltageMedium30 VExtremely bendingresistant,tinnedcopper shieldTesting voltageOilFlame-retardant500 VOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA).According to IEC 60332-1-2, CEI 20-34, FT1, VW-1Cores and pairesstranded with anespecially shortpitch lengthSilicon-freeConductorCore insulationFree from silicon which can affect paint adhesion (followingPV 3.10.7 – status 1992).Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Mechanically high-quality PE mixture.Gusset-filled extruded,flame-retardant TPEmixtureCore strandingCore identificationElement shieldOuter jacketCores and paires stranded with an especially short pitch length.Core 0,15 mm 2 : orange/blue, green/red.Core 0,34 mm 2 : black, white.Extremely flexible, tinned copper shield over foil taping. Coverageapprox. 70% linear, approx. 90% optical.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® . Colour: Red lilac (similar to RAL 4001)FireWire234Image exemplary.... no minimum order quantity


FireWireTPE12,5 x dUL/CSA Style 1589 and 21371, 30 V, 80 °CDESINAAccording to VDW, DESINA standardisationCELead freeFollowing 2006/95/ECFollowing 2002/95/EC (RoHS).<strong>Chainflex</strong> ®FireWireClean room According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1Typical application area● FireWire cable for use in E-Chains ® in industrial environments (Technical note page 478)● Transmission lengths of up to 10 mTest data page 38Camera reference list page 254Tel. +49-2203-96 49-0Fax +49-2203-96 49-222More than 6.0 million movements have been successfully tested with the CFBUS.055 in E-Chains ® with 10 m cable length.950 types from stock no cutting costs ...(for up to 10 cuts of the same type)235


FireWireTPE12,5 x dTPE Bus cable<strong>Chainflex</strong> ® FireWire● FireWire cable (IEEE 1394a)● for maximum load requirements● TPE outer jacket● oil-resistant● flame-retardantAs well available on the roll, in the lengths you require.Part No.Number of cores and conductornominal cross section [mm 2 ]External diameterapprox. [mm]CFBUS.055 2 (2 x 0,15) C+2 x (0,34) C 7,5 42 81Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.Copper index[kg/km]Weight[kg/km]Choose from the following plug-cable combinationsConnector body with clipPart No.:MAT9048160Connector body with clipPre-assembledon both sidesConnector body with clipMAT9048621Pin body without clipPre-assembledon both sidesConnector body with clipMAT9048623Moulded connector socket without clipPre-assembledon both sidesImage exemplary.Connector body with clipMAT9048625Formschrumpfteil Sift without clipPre-assembledon both sidesMoulded connector pin without clipMAT9048627Moulded connector pin without clipPre-assembledon both sidesFireWire... no minimum order quantity236


FireWireTPE12,5 x d<strong>Chainflex</strong> ®FireWirePin body without clipPart No.:MAT9048620Pin body without clipPre-assembledon both sidesPin body without clipPin body without clipMAT9048622MAT9048624Moulded connector socket without clipMoulded connector pin without clipPre-assembledon both sidesPre-assembledon both sidesTel. +49-2203-96 49-0Fax +49-2203-96 49-222Moulded connector socket without clipMAT9048626Moulded connector socket without clipPre-assembledon both sidesMoulded connector socket without clipMAT9048628Moulded connector pin without clipPre-assembledon both sides950 types from stock no cutting costs ...(for up to 10 cuts of the same type)237


USBTPE12,5 x dTPE Bus cable<strong>Chainflex</strong> ® USB● USB cable 2.0● for maximum load requirements● TPE outer jacket● oil-resistant● flame-retardantEspecially bendingresistantfine-wirestranded conductorTemperature rangemovedTemperature rangefixedv max.unsupported/gliding-35 °C to +70 °C, minimum bending radius 12,5 x d-40 °C to +70 °C, minimum bending radius 5 x d10 m/s, 6 m/sa max. 100 m/s 2Cores and pairesstranded with anespecially shortpitch lengthUV-resistantNominal voltageMedium30 VTesting voltage500 VExtremely bendingresistant.tinnedcopper shieldOilFlame-retardantSilicon-freeConductorCore insulationOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA).According to IEC 60332-1-2, CEI 20-34, FT1, VW-1Free from silicon which can affect paint adhesion (followingPV 3.10.7 – status 1992).Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Mechanically high-quality PE mixture.Core strandingCores and paires stranded with an especially short pitch lengthPressure extruded.flame-retard TPEblendUSBCore identification Core 0,5 mm 2 : red, blackCore 0,08 mm 2 : white, green (CFBUS.065).Core 0,24 mm 2 : white. green (CFBUS.066).Overall shield Extremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Outer jacketLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® . Colour: Red lilac (similar to RAL 4001)UL/CSA Style 1589 and 21371, 30 V, 80 °CDESINAAccording to VDW, DESINA standardisationCEFollowing 2006/95/EC238Image exemplary.... no minimum order quantity


USBTPE12,5 x dLead freeFollowing 2002/95/EC (RoHS).Clean room According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1Typical application area● USB 2.0 cable for use in E-Chains ® in industrial environments (Technical note page 478)● Transmission lengths of up to 6 m (CFBUS.065)● Transmission lengths of up to 10 m (CFBUS.066)<strong>Chainflex</strong> ®USBCamera reference list page 254Tel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...(for up to 10 cuts of the same type)239


USBTPE12,5 x dTPE Bus cable<strong>Chainflex</strong> ® USB● USB cable 2.0● for maximum load requirements● TPE outer jacket● oil-resistant● flame-retardantAs well available on the roll, in the lengths you require.Part No.Number of cores and conductornominal cross section [mm 2 ]External diameterapprox. [mm]Copper index[kg/km]Weight[kg/km]CFBUS.065(2 x 0,5+1 x (2 x 0,08))C5,02645Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.Choose from the following plug-cable combinationsUSB Type AArt.-Nr.:open end of cablePre-assembledUSB9040001at one endUSB Type AUSB Type APre-assembledUSB9040010on both sidesUSB Type Bopen end of cablePre-assembledUSB9040020at one endUSB Type BUSB Type BPre-assembledUSB9040030on both sidesAbbildung exemplarisch.USB Type AUSB9040040USB Type BPre-assembledon both sidesUSB Type AUSB Type A (Socket)Pre-assembledUSB9040060on both sidesUSB... no minimum order quantity240


USBTPE12,5 x d<strong>Chainflex</strong> ®USBAs well available on the roll, in the lengths you require.Part No.Number of cores and conductornominal cross section [mm 2 ]External diameterapprox. [mm]Copper index[kg/km]Weight[kg/km]CFBUS.066*(2 x 0,5+1 x (2 x 0,24))C6,03256* CFBUS.066 is delivered with form shrink hose over USB housingNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.Choose from the following plug-cable combinationsUSB Type AUSB Type AArt.-Nr.:USB9040201USB9040210open end of cableUSB Type APre-assembledat one endPre-assembledon both sidesTel. +49-2203-96 49-0Fax +49-2203-96 49-222USB Type Bopen end of cablePre-assembledUSB9040220at one endUSB Type BUSB Type BPre-assembledUSB9040230on both sidesUSB Type AUSB Type BPre-assembledUSB9040240on both sidesUSB Type AUSB Type A (Socket)Pre-assembledUSB9040260on both sides950 types from stock no cutting costs ...(for up to 10 cuts of the same type)241


GigETPE12,5 x dEspecially bendingresistantfine-wirestranded conductorTPE Bus cable<strong>Chainflex</strong> ® GigE● GigE cable● Ethernet special cable for heavy-duty use● TPE outer jacket● oil-resistant● flame-retardantCores and pairesstranded with anespecially shortpitch lengthTemperature range -35 °C to +70 °C, minimum bending radius 12,5 x dmovedTemperature range -40 °C to +70 °C, minimum bending radius 7,5 x dfixedv max.10 m/s, 6 m/sunsupported/glidinga max. 100 m/s 2UV-resistantMediumNominal voltage30 VTesting voltage500 VGusset-filledextrudedOilFlame-retardantOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA).According to IEC 60332-1-2, CEI 20-34, FT1, VW-1.Extremely bendingresistant,tinnedcopper shieldSilicon-freeConductorCore insulationFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).Special PP-isolating mixturePressure extruded,flame-retard TPEblendCore stranding 2 cores each stranded in pairs with short pitch lengths, corepairs also stranded with short pitch lengths.Core identification Colour code in accordance with DIN 47100Inner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .GigEOverall shield Extremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Outer jacketLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® . Colour: Red lilac (similar to RAL 4001)UL/CSA Style 1589 and 21371, 30 V, 80 °CCEFollowing 2006/95/ECDESINAAccording to VDW, DESINA standardisation242Image exemplary.... no minimum order quantity


GigETPE12,5 x dLead freeFollowing 2002/95/EC (RoHS).Clean room According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1Typical application area● Ethernet cable for use in E-Chains ® in industrial environments (Technical note page 478)● Transmission lengths of up to 50 m<strong>Chainflex</strong> ®GigECamera reference list page 254As well available on the roll, in the lengths you require.Part No.:CFBUS.044CFROBOT8.045Number of cores and conductornominal cross section [mm 2 ](4x (2 x 0,15)) C(4x (2 x 0,14)) CExternal diameterapprox. [mm]8,08,5Copper index[kg/km]3535Weight[kg/km]7965Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Choose from the following plug-cable combinationsConnector RJ45 Metall, 8 polesPart No.:GIG9040001Connector RJ45 Metall, 8 polesPre-assembledon both sidesConnector RJ45 Metall, 8 polesPart No.:GIG9040002Plug made of RJ45 plastic with knurled screwsPre-assembledon both sidesNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.950 types from stock no cutting costs ...(for up to 10 cuts of the same type)243


FOCPUR12,5 x dGradient fibersPUR Fibre optic cable (FOC)<strong>Chainflex</strong> ® Glass fibre● Gradient glass fibre cable 50/125 µm, 62.5/125 µm● PUR outer jacket● oil-resistant● UV-resistantPlastic coveredspecial fiberTemperature range -20 °C to +60 °C, minimum bending radius 12,5 x dmovedTemperature range -25 °C to +60 °C, minimum bending radius 7,5 x dfixedv max.10 m/s, 6 m/sunsupported/glidinga max. 20 m/s 2UV-resistantHighOil Oil-resistant (following DIN EN 60811-2-1)Gel-filled, armoredhollow coreOffshore MUD-resistant following NEK 606Silicon-freeFibre <strong>cables</strong>Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).50/125 µm, 62.5/125 µm fibres in gel-filled hollow cores.Armored hollow coreswith optimized pitchlength stranded arounda strain relief elementCore strandingCore identificationHollow cores with integrated FOC-fibres stranded with twostrain relief elements.Cores black with white numerals.Gusset-filledextrudedPUR mixtureOuter jacketCELead freeLow-adhesion mixture on the basis of PUR, adapted to suitthe requirements in Energy Chains ® (following DIN VDE 0282Part 10). Colour: Jet black (similar to RAL 9005)Following 2006/95/ECFollowing 2002/95/EC (RoHS).FOC244Image exemplary.... no minimum order quantity


FOCPUR12,5 x dTypical application area● Fiber optic cable for use in E-Chains ® in industrial environments● Transmission lengths of up to 500 mTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®LWLTest data page 36Camera reference list page 254Harnessed igus ® E6 system on a camera application.950 types from stock no cutting costs ...(for up to 10 cuts of the same type)245


FOCPUR12,5 x dPUR Fibre optic cable (FOC)<strong>Chainflex</strong> ® Glass fibre● Gradient glass fibre cable 50/125 µm, 62.5/125 µm● PUR outer jacket● oil-resistant● UV-resistantAs well available on the roll, in the lengths you require.Part No.Number offibersFibre diameterapprox. [µm]External diameterapprox. [mm]Weight[kg/km]CFLG.2HG.MF.50/125250/1259.085Connector STLWL90412393Connector LCPre-assembledon both sides*Connector STLWL90412394Connector STPre-assembledon both sidesConnector LCLWL90412395Connector LCPre-assembledon both sidesCFLG.2HG.MF.62.5/125 2 62.5/125 9.085Connector STLWL90412396Connector LCPre-assembledon both sides*Image exemplary.Connector STConnector LCLWL90412397LWL90412398Connector STConnector LCPre-assembledon both sidesPre-assembledon both sides* 2 ST coupling pieces needed to be ordered extra, if used as extension cable (MAT0176314).FOCTube sinking LWL90428935Closed corrugated tube to feed in Fibre optic <strong>cables</strong> (image shown cut open)246... no minimum order quantity


FOCPUR12,5 x dFOC patch <strong>cables</strong> for static installation:(Note: FOC patch cable extensions are for protected installation only)Part No.Number offibersFibre diameterapprox. [µm]External diameterapprox. [mm]Weight[kg/km]<strong>Chainflex</strong> ®FOCFFLG.2G.50/125250/1256.527Connector STLWL90412399Connector LCPre-assembledon both sides*Connector STConnector LCLWL90412400LWL90412401Connector STConnector LCPre-assembledon both sidesPre-assembledon both sidesTel. +49-2203-96 49-0Fax +49-2203-96 49-222FFLG.2G.62.5/125 2 62.5/125 6.527Connector ST LWL90412402Connector LC Pre-assembledon both sides*Connector STLWL90412403Connector STPre-assembledon both sidesConnector LCLWL90412404Connector LCPre-assembledon both sides* 2 ST coupling pieces needed to be ordered extra, if used as extension cable (MAT0176314).950 types from stock no cutting costs ...(for up to 10 cuts of the same type)247


ROBOT-FOCTPE12,5 x dFOC wires with hightensilearamide fibresTPE Fibre optic <strong>cables</strong>, twistable<strong>Chainflex</strong> ® CF ROBOT5● for twistable loads● TPE outer jacket● oil-resistant● bio-oil-resistant● UV-resistant● low-temperature-flexibleGRP core elementTemperature range -20 °C to +60 °C, minimum bending radius twisted 12,5 x dmovedTemperature range -25 °C to +60 °C, minimum bending radius twisted 7,5 x dfixedv max.10 m/stwisteda max. 10 m/s 2Torsion±180 °, with 2 m cable lengthFOC wires strandedwith dampers aroundthe GRP coreUV-resistantOilSilicon-freeFibre CablesCore strandingOuter jacketCEHighOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA).Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).50/125 µm, 62.5/125 µm special fixed wire elements witharamide strain relief.FOC wires stranded with high-tensile aramide dampersaround the GRP central element.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® .Following 2006/95/ECPressure extruded,halogen-freeTPE blendLead freeClean roomFollowing 2002/95/EC (RoHS)According to ISO Class 1. Outer jacket material complies withCF9.15.07, tested by IPA according to standard 14644-1FOCTypical application arean for maximum load requirements with torsion movementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for robots and movements in the 3D rangen Robots, handling248Image exemplary.... no minimum order quantity


ROBOT-FOCTPE12,5 x dAs well available on the roll, in the lengths you require.Part No.Number offibersFibre diameterapprox. [µm]External diameterapprox. [mm]Weight[kg/km]CFROBOT5.501Connector ST250/125LWL904224918.587Connector LC Pre-assembledon both sides*<strong>Chainflex</strong> ®FOCConnector STLWL90422492Connector STPre-assembledon both sidesConnector LCLWL90422493Connector LCCFROBOT.500 2 62.5/125 8.587Connector STLWL90422494Connector LCPre-assembledon both sidesPre-assembledon both sides*Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Connector STLWL90422495Connector STPre-assembledon both sidesConnector LCLWL90422496Connector LCPre-assembledon both sides* 2 ST coupling pieces needed to be ordered extra, if used as extension cable (MAT0176314).Tube sinking LWL90428935Closed corrugated tube to feed in Fibre optic <strong>cables</strong> (image shown cut open)950 types from stock no cutting costs ...(for up to 10 cuts of the same type)249


CF Koax 1TPE10 x dEspecially bendingresistantspecialconductorHighly flexible braidedcopper shieldTPE Koax cable<strong>Chainflex</strong> ® CF Koax 1● 75 Ω koax cable for maximum load requirements● TPE outer jacket● oil-resistant● bio-oil-resistant● UV-resistant● hydrolysis-resistant and microbe-resistantTemperature rangemoved-35 °C to +100 °C, minimum bending radius 10 x dTemperature rangefixed-40 °C to +100 °C, minimum bending radius 7,5 x dv max.unsupported/gliding 10 m/s, 5 m/sa max. 100 m/s 2Travel distance Freely suspended and gliding travel distances up to 400 m,Class 4UV-resistantHighNominal voltage 300/300 V (following DIN VDE 0245).Testing voltage1500 VElements strandedwith short pitch,FEP special insulationOilSilicon-freeConductorOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.Free from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Multi-wire; adapted in single-wire diameter and pitch length tosuit the requirements in Energy Chains ® .Core insulationSpecial FEP-isolating mixture.Gusset-filledextruded,halogen-freeTPE mixtureCore strandingCore identificationElement shieldCores stranded in one layer with especially short pitch length.Schedule delivery programExtremely bending-resistant, tinned braided copper shield.Coverage approx. 70% linear, approx. 90% optical.Element jacket TPE mixture adapted to suit the requirements in Energy Chains ® .KOAXOuter jacketLow-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirementsin Energy Chains ® .Colour: Steel blue (similar to RAL 5011)250Image exemplary.... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Price indexCF Koax 1TPE10 x dCEFollowing 2006/95/ECLead freeClean roomInfoFollowing 2002/95/EC (RoHS).According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested byIPA according to standard 14644-1The coax elements used in <strong>cables</strong> of the CF Koax1 series are comparable with aHF75-0.3/1.6 according to MIL-C-17/94-RG179 and thus fit in an RG179 plug!Koax cableTypical application arean for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to 400 mn storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,semiconductor insertion, outdoor cranes, low-temperature applicationsTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFKOAX1 (for up to 10 cuts of the same type)251


CF Koax 1TPE10 x dTPE Koax cable<strong>Chainflex</strong> ® CF Koax 1● 75 Ω koax cable for maximum load requirements● TPE outer jacket● oil-resistant● bio-oil-resistant● UV-resistant● hydrolysis-resistant and microbe-resistantAs well available on the roll, in the lengths you require.Part No.Number of fibersExternal diameterapprox. [µm]Copper index[kg/km]Weight[kg/km]CFKoax1.01 1 coaxial element4,59,0Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core25Choose from the following plug-cable combinationsConnectorMAT90423400SocketPre-assembledon both sidesConnectorMAT90423401ConnectorPre-assembledon both sidesSocketMAT90423402SocketPre-assembledon both sidesConnectorMAT90423403open end of cablePre-assembledon one sideImage exemplary.SocketMAT90423404open end of cablePre-assembledon one sideKOAX252... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


Price indexCF Koax 1TPE10 x dAs well available on the roll, in the lengths you require.Part No.CFKoax1.05Number of fibers5 coaxial elementsExternal diameterapprox. [µm]10,0Copper index[kg/km]Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core47Weight[kg/km]135Koax cableChoose from the following plug-cable combinationsConnectorMAT90423405SocketPre-assembledon both sidesConnectorSocketMAT90423406MAT90423407ConnectorSocketPre-assembledon both sidesPre-assembledon both sidesTel. +49-2203-96 49-0Fax +49-2203-96 49-222ConnectorMAT90423408open end of cablePre-assembledon one sideSocketMAT90423409open end of cablePre-assembledon one side950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFKOAX1 (for up to 10 cuts of the same type)253


ContentCamera reference list – Selection chartCFBUS.065 CFBUS.066 CFBUS.055 CFLG.2HG CFBUS.044USB USB FireWire LWL GigEup to 5 m up to 10 m up to 10 m up to 400 m up to 50 mTel. +49-2203-96 49-0<strong>Chainflex</strong> ®Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.deGuppy F-033B Pike F-032B Fiber GB650, GB650cGuppy F-033C Pike F-032C Fiber GB660, GB660cGuppy F-036B Pike F-100B Fiber GB1380, GB1380cGuppy F-036C Pike F-100C Fiber GB2450, GB2450cGuppy F-038B Pike F-145B Fiber GC640, GC640cGuppy F-038C Pike F-145C Fiber GC650, GC650cGuppy F-038B NIR Pike F-210B Fiber GC655, GC655cGuppy F-038C NIR Pike F-210C Fiber GC660, GC660cGuppy F-044B Pike F-421B Fiber GC750, GC750cGuppy F-044C Pike F-421C Fiber GC780, GC780CGuppy F-044B NIR Pike F-505B Fiber GC1020, GC1020cGuppy F-044C NIR Pike F-505C Fiber GC1280Guppy F-046B Stingray F-033B Fiber GC1290, GC1290cGuppy F-046C Stingray F-033C Fiber GC1350, GC1350cGuppy F-080B Stingray F-046B Fiber GC1380, GC1380cGuppy F-080C Stingray F-046C Fiber GC1380CH, GC1380HGuppy F-146B Stingray F-080B Fiber GC1600, GC1600cGuppy F-146C Stingray F-080C Fiber GC1600CH, GC1600HGuppy F-503B Stingray F-125B Fiber GC2450, GC2450cGuppy F-503C Stingray F-125C Fiber GE640, GE640cMarlin F-033B Stingray F-145B Fiber GE650, GE650cMarlin F-033C Stingray F-145C Fiber GE680, GE680cMarlin F-046B Stingray F-146B Fiber GE1050, GE1050cMarlin F-046C Stingray F-146C Fiber GE1350, GE1350cMarlin F-080B Stingray F-201B Fiber GE1380, GE1380cMarlin F-080C Stingray F-201C Fiber GE1600, GE1600cMarlin F-080B 30fps Stingray F-504B Fiber GE1650, GE1650cMarlin F-080C 30fps Stingray F-504C Fiber GE1660, GE1660cMarlin F-131BGE1900, GE1900cMarlin F-131CGE1910, GE1910cMarlin F-131B NIRGE2040, GE2040cMarlin F-145B2GE4000, GE4000cMarlin F-145C2GE4900, GE4900cMarlin F-146BGS650, GS650cMarlin F-146CGS660, GS660cMarlin F-201BGS1380, GS1380cMarlin F-201CGS2450, GS2450cOscar F-320COscar F-510COscar F-810CARTCAM-...ARTCAM-...640-THERMO 640-THERMO320-THERMO 320-THERMO150P4-HDMI150P4-HDMI150P4-HDMI-BW 150P4-HDMI-BW130MI-HDMI130MI-HDMI130MI-HDMI-BW 130MI-HDMI-BW150P4-MOUT-DUAL 150P4-MOUT-DUAL150P4-MOUT-DUAL-BW 150P4-MOUT-DUAL-BW130MI-MOUT-DUAL 130MI-MOUT-DUAL130MI-MOUT-DUAL-BW 130MI-MOUT-DUAL-BW625KY625KY625KY-BW625KY-BW500P II500P II274KY274KY274KY-BW274KY-BW254


Camera reference list – Selection chartContentCFBUS.065 CFBUS.066 CFBUS.055 CFLG.2HG CFBUS.044USB USB FireWire LWL GigEup to 5 m up to 10 m up to 10 m up to 400 m up to 50 mARTCAM-...ARTCAM-...150P III150P III150P III -BW150P III -BW445KY445KY445KY-BW445KY-BW098 II 098 II098 II -BW 098 II -BW900MI900MI500MI500MI500MI-BW500MI-BW300MI300MI130MI130MI130MI-BW130MI-BW036MI036MI036MI-BW036MI-BW900SS900SS500SS500SS500SS-BW500SS-BW300SS300SS130SS130SS130SS-BW130SS-BW036SS036SS036SS-BW036SS-BW022MINI022MINI022MINI-BW 022MINI-BWA102fA102fcA311fA311fcA312fA312fcA601fA601fcA631fA631fcA641fA641fcpiA640-210gm/gcpiA1000-48gm/gcpiA1600-35gm/gcpiA1900-32gm/gcpiA2400-12gm/gcruL1024-19gmruL1024-36gmruL1024-57gmruL2048-10gmruL2048-19gmruL2048-30gmruL2098-10gcscA640-70gm/gcscA640-74gm/gcscA750-60gm/gcscA780-54gm/gcscA1000-20gm/gcscA1000-30gm/gcscA1390-17gm/gcscA1400-17gm/gcscA1400-30gm/gcscA1600-14gm/gcscA1600-14gm/gcwww.igus.euinfo@igus.deTel. +49-2203-96 49-0<strong>Chainflex</strong> ®Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germany255


ContentCamera reference list – Selection chartCFBUS.065 CFBUS.066 CFBUS.055 CFLG.2HG CFBUS.044USB USB FireWire LWL GigEup to 5 m up to 10 m up to 10 m up to 400 m up to 50 mwww.igus.euinfo@igus.de<strong>Chainflex</strong> ®FWX03FWX03cFWX05c-IIFWX05-IIFWX06FWX06cFWX08FWX08cFWX131FWX131cFWX14FWX14cFWX20FWX20cFWXC03cFWXC13cFWXC30cFWL120FQX50cFQX80cTXGC03TXGC03cTXG03 [-P]TXG03c [-P]TXG04 [-P]TXG04c [-P]TXG06 [-P]TXG06c [-P]TXG08 [-P]TXG08c [-P]TXG13 [-P]TXG13c [-P]TXG14 [-P]TXG14c [-P]TXG14f [-P]TXG14cf [-P]TXG20 [-P]TXG20c [-P]TXG50 [-P]TXG50c [-P]Tel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® GmbH51147 Köln, GermanyUI-1220-M/CUI-5220SE-M/CUI-1540-MUI-5540SE-MUI-1640-CUI-5640SE-CUI-1550-CUI-5550SE-CUI-1460-CUI-5460SE-CUI-1480-M/CUI-5480SE-M/CUI-2210-M/CUI-6210SE-M/CUI-2410-M/CUI-6410SE-M/CUI-2220-M/CUI-6220SE-M/CUI-2230-M/CUI-6230SE-M/CUI-2240-M/CUI-6240SE-M/CUI-2250-M/CUI-6250SE-M/CUI-1220RE-M/C UI-1220RE-M/C UI-5220HE-M/CUI-1540RE-M UI-1540RE-M UI-5540HE-MUI-1640RE-C UI-1640RE-C UI-5640HE-CUI-1550RE-C UI-1550RE-C UI-5550HE-CUI-1460RE-C UI-1460RE-C UI-5460HE-CUI-1480RE-M/C UI-1480RE-M/C UI-5480HE-M/CUI-2210RE-M/C UI-2210RE-M/C UI-6210HE-M/CUI-2410RE-M/C UI-2410RE-M/C UI-6410HE-M/CUI-2220RE-M/C UI-2220RE-M/C UI-6220HE-M/CUI-2230RE-M/C UI-2230RE-M/C UI-6230HE-M/CUI-2240RE-M/C UI-2240RE-M/C UI-6240HE-M/CUI-2250RE-M/C UI-2250RE-M/C UI-6250HE-M/C256


Camera reference list – Selection chartContentCFBUS.065 CFBUS.066 CFBUS.055 CFLG.2HG CFBUS.044USB USB FireWire LWL GigEup to 5 m up to 10 m up to 10 m up to 400 m up to 50 mDMK 21AU04 DMK 21AU04 DMK 21F04DFK 21AU04 DFK 21AU04 DFK 21F04DBK 21AU04 DBK 21AU04 DMK 21AF04DMK 31AU03 DMK 31AU03 DFK 21AF04DFK 31AU03 DFK 31AU03 DBK 21AF04DBK 31AU03 DBK 31AU03 DMK 31AF03DMK 41AU02 DMK 41AU02 DFK 31AF03DFK 41AU02 DFK 41AU02 DBK 31AF03DBK 41AU02 DBK 41AU02 DMK 41AF02DMK 21BU04 DMK 21BU04 DFK 41AF02DFK 21BU04 DFK 21BU04 DBK 41AF02DBK 21BU04 DBK 21BU04 DMK 21BF04DMK 31BU03 DMK 31BU03 DFK 21BF04DFK 31BU03 DFK 31BU03 DBK 21BF04DBK 31BU03 DBK 31BU03 DMK 31BF03DMK 41BU02 DMK 41BU02 DFK 31BF03DFK 41BU02 DFK 41BU02 DBK 31BF03DBK 41BU02 DBK 41BU02 DMK 41BF02DMK 21BU04.H DMK 21BU04.H DFK 41BF02DFK 21BU04.H DFK 21BU04.H DBK 41BF02DBK 21BU04.H DBK 21BU04.H DMK 21BF04.HDMK 31BU03.H DMK 31BU03.H DFK 21BF04.HDFK 31BU03.H DFK 31BU03.H DBK 21BF04.HDBK 31BU03.H DBK 31BU03.H DMK 31BF03.HDMK 41BU02.H DMK 41BU02.H DFK 31BF03.HDFK 41BU02.H DFK 41BU02.H DBK 31BF03.HDBK 41BU02.H DBK 41BU02.H DMK 41BF02.HDFK 41BF02.HDBK 41BF02.HDMK 21AF04-ZDFK 21AF04-ZDBK 21AF04-ZDMK 31AF03-ZDFK 31AF03-ZDBK 31AF03-ZDMK 21BF04-ZDFK 21BF04-ZDBK 21BF04-ZDMK 31BF03-ZDFK 31BF03-ZDBK 31BF03-ZDMK 21BF04-Z.HDFK 21BF04-Z.HDBK 21BF04-Z.HDMK 31BF03-Z.HDFK 31BF03-Z.HDBK 31BF03-Z.Hwww.igus.euinfo@igus.deTel. +49-2203-96 49-0<strong>Chainflex</strong> ®Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germany257


etworketwork-/Ethernet-/FOC-cable/Fieldbus


<strong>Chainflex</strong> ® ReadyCable ®Network-/Ethernet-/FOC-cable/FieldbusCable type Jacket PageCFLG.6G Gradient fibre glass cable, ready-made TPE 260CFLG.12G Gradient fibre glass cable, ready-made TPE 262CAT5 Ethernet cable, ready-made TPE 264CAT5 Ethernet cable, ready-made, L-/T-angle TPE 266CAT6 Ethernet cable, ready-made TPE 268Profibus Field bus cable, ready-made PVC/PUR/TPE 270259


CFLG.6GTPE15 x dTPE Fibre optic cable<strong>Chainflex</strong> ® Fibre Optic● Gradient glass-fiber cable for heavy-duty use● TPE outer jacket● halogen-free● low-temperature-flexible up to -40 °CGradient fibersTemperature range -40 °C to +60 °C, minimum bending radius 15 x dmovedTemperature range -40 °C to +60 °C, minimum bending radius 8.5 x dfixedv max.10 m/s, 6 m/sunsupported/glidinga max. 20 m/s 2UV-resistantHighGel-filled fiber sheathOilOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA).Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Stranded GRP rodsFibre <strong>cables</strong>50/125 µm, 62.5/125 µm fibres in gel-filled hollow cores.Core strandingOuter jacketCEStranded GRP rods with integrated torsion protection braid inthe outer jacket over gel-filled fiber sheath.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® . Colour: Jet black (similar to RAL 9005)Following 2006/95/ECLead freeFollowing 2002/95/EC (RoHS).Highly abrasionresistantTPE blendwith integrated torsionprotection braidFibre OpticTypical application arean for maximum load requirementsn Maximum EMC protection, with high transmission qualities in terms of glass-specific requirementsn almost unlimited resistance to oil, also with bio-oilsn Indoor and outdoor applicationsn only for freely suspended and gliding travel distances up to 500 m and moren Outdoor ship to shore, crane applications, conveyer technology260Image exemplary.... no minimum order quantity


15xPrice indexCFLG.6GTPE15 x dTest data page 40<strong>Chainflex</strong> ® TPE gradient glass-fiber cable<strong>Chainflex</strong> ®Fibre OpticDelivery program igus ®Part No.Number of cores andconductor nominalcross section [mm 2 ]ø[mm]Tel. +49-2203-96 49-0Fax +49-2203-96 49-222On both ends BFOC(ST) connectors LWL9040030 6x50/125 11.5On both ends BFOC(ST) connectorsincl. conversion to SC LWL9040031 6x50/125 11.5On both ends BFOC(ST) connectorsincl. conversion to LC LWL9040032 6x50/125 11.5On both ends BFOC(ST) connectors LWL9040045 6x62.5/125 11.5On both ends BFOC(ST) connectorsincl. conversion to SC LWL9040046 6x62.5/125 11.5On both ends BFOC(ST) connectorsincl. conversion to LC LWL9040047 6x62.5/125 11.5Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.Tube sinking LWL90428936Closed corrugated tube to feed in Fibre optic <strong>cables</strong> (image shown cut open)950 types from stock no cutting costs ...(for up to 10 cuts of the same type)261


CFLG.12GTPE15 x dTPE Fibre optic cable<strong>Chainflex</strong> ® Fibre Optic● Gradient glass-fiber cable for heavy-duty use● TPE outer jacket● halogen-free● low-temperature-flexible up to -40 °CGradient fibersTemperature range -40 °C to +60 °C, minimum bending radius 15 x dmovedTemperature range -40 °C to +60 °C, minimum bending radius 8.5 x dfixedv max.10 m/s, 6 m/sunsupported/glidinga max. 20 m/s 2UV-resistantHighGel-filled fiber sheathOilOil-resistant (following DIN EN 60811-2-1), bio-oil-resistant(following VDMA 24568 with Plantocut 8 S-MB tested by DEA).Silicon-freeFree from silicon which can affect paint adhesion(following PV 3.10.7 – status 1992).Halogen-free Following EN 50267-2-1.Stranded GRP rodsFibre <strong>cables</strong>50/125 µm, 62.5/125 µm fibres in gel-filled hollow cores.Core strandingOuter jacketCEStranded GRP rods with integrated torsion protection braid inthe outer jacket over gel-filled fiber sheath.Low-adhesion mixture on the basis of TPE, especially abrasionresistantand highly flexible, adapted to suit the requirements inEnergy Chains ® . Colour: Jet black (similar to RAL 9005)Following 2006/95/ECLead freeFollowing 2002/95/EC (RoHS).Highly abrasionresistantTPE blendwith integrated torsionprotection braidFibre OpticTypical application arean for maximum load requirementsn Maximum EMC protection, with high transmission qualities in terms of glass-specific requirementsn almost unlimited resistance to oil, also with bio-oilsn Indoor and outdoor applicationsn only for freely suspended and gliding travel distances up to 500 m and moren Outdoor ship to shore, crane applications, conveyer technology262Image exemplary.... no minimum order quantity


15xPrice indexCFLG.12GTPE15 x dTest data page 40<strong>Chainflex</strong> ® TPE gradient glass-fiber cable<strong>Chainflex</strong> ®Fibre OpticDelivery program igus ®Part No.Number of cores andconductor nominalcross section [mm 2 ]ø[mm]Tel. +49-2203-96 49-0Fax +49-2203-96 49-222On both ends BFOC(ST) connectors LWL9040060 12x50/125 11.5On both ends BFOC(ST) connectorsincl. conversion to SC LWL9040061 12x50/125 11.5On both ends BFOC(ST) connectorsincl. conversion to LC LWL9040062 12x50/125 11.5On both ends BFOC(ST) connectors LWL9040075 12x62.5/125 11.5On both ends BFOC(ST) connectorsincl. conversion to SC LWL9040076 12x62.5/125 11.5On both ends BFOC(ST) connectorsincl. conversion to LC LWL9040077 12x62.5/125 11.5Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.Tube sinking LWL90428936Closed corrugated tube to feed in Fibre optic <strong>cables</strong> (image shown cut open)950 types from stock no cutting costs ...(for up to 10 cuts of the same type)263


CAT5<strong>Chainflex</strong> ® network techniqueCAT5 <strong>cables</strong> harnessedTechnical informationn oil-resistantn UV-resistantn halogen-freen external jacket on the basis of TPEn Shield: extremely bending-resistant copper shieldwith greatest possible coverage over aluminiumcoatedplastic foil.n Temperature range (moved): -35 °C to +70 °C<strong>Chainflex</strong> ® -TPE Energy Chains ® Ethernet special cableDelivery program igus ®Part No.Number of coresand conductornominal crosssection [mm 2 ]ø [mm]BendingradiusCAT5 – 4 poleStraight CAT9040001 (2x(2x0,25))C 7.0 12,5 x dCAT5 – 8 poleStraight CAT9040020 (4x(2x0,15))C 8.0 12,5 x dCAT5 – 8 poleStraight CAT9040060 (4x(2x0,15))C 8.0 12,5 x dCAT5 – 8 poleStraight CAT9040100 (4x(2x0,15))C 8.0 12,5 x dNetwork technique264CAT5 – 8 poleStraight CAT9040140 (4x(2x0,15))C 8.0 12,5 x dCAT5 – 8 poleStraight CAT9040180 (4x(2x0,15))C 8.0 12,5 x dNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core... no minimum order quantity


12.5xCAT5n Minimum bending radius for use in Energy Chains ® :12.5 x cable diametern Colour: Red lilac (similar to RAL 4001)<strong>Chainflex</strong> ® -TPE Energy Chains ® Ethernet special cable<strong>Chainflex</strong> ®network techniqueDelivery program igus ®Part No.Number of coresand conductornominal crosssection [mm 2 ]ø [mm]BendingradiusCAT5 – 8 poleCross-Over CAT9040040 (4x(2x0,15))C 8.0 12,5 x dTel. +49-2203-96 49-0Fax +49-2203-96 49-222CAT5 – 8 poleCross-Over CAT9040080 (4x(2x0,15))C 8.0 12,5 x dCAT5 – 8 poleCross-Over CAT9040120 (4x(2x0,15))C 8.0 12,5 x dCAT5 – 8 poleCross-Over CAT9040160 (4x(2x0,15))C 8.0 12,5 x dCAT5 – 8 poleCross-Over CAT9040200 (4x(2x0,15))C 8.0 12,5 x dNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)265


CAT5<strong>Chainflex</strong> ® network techniqueCAT5 <strong>cables</strong> harnessedTechnical informationn oil-resistantn UV-resistantn halogen-freen external jacket on the basis of TPEn Shield: extremely bending-resistant copper shieldwith greatest possible coverage over aluminiumcoatedplastic foil.n Temperature range (moved): -35 °C to +70 °C<strong>Chainflex</strong> ® -TPE Energy Chains ® Ethernet special cableConnector 01L-angle curve lowerConnector 02L-angle curve aboveConnector 03T-angle curve outerConnector 04T-angle curve inwardConnector 05straightNetwork technique266... no minimum order quantity


12.5xCAT5n Minimum bending radius for use in Energy Chains ® :12.5 x cable diametern Colour: Red lilac (similar to RAL 4001)<strong>Chainflex</strong> ® -TPE Energy Chains ® Ethernet special cable<strong>Chainflex</strong> ®network techniqueDelivery program Pre-assembled Number of cores ø [mm] Bending8-pole Straight with connector and conductorradiusPart No.combination nominal crosssection [mm 2 ]CAT9040380 1 2 (4x(2x0,15))C 8,0 12,5CAT9040540 1 3 (4x(2x0,15))C 8,0 12,5CAT9040560 1 4 (4x(2x0,15))C 8,0 12,5CAT9040320 1 5 (4x(2x0,15))C 8,0 12,5CAT9040360 2 1 (4x(2x0,15))C 8,0 12,5CAT9040340 2 2 (4x(2x0,15))C 8,0 12,5CAT9040500 2 3 (4x(2x0,15))C 8,0 12,5CAT9040520 2 4 (4x(2x0,15))C 8,0 12,5CAT9040300 2 5 (4x(2x0,15))C 8,0 12,5CAT9040440 3 3 (4x(2x0,15))C 8,0 12,5CAT9040480 3 4 (4x(2x0,15))C 8,0 12,5CAT9040400 3 5 (4x(2x0,15))C 8,0 12,5CAT9040460 4 4 (4x(2x0,15))C 8,0 12,5CAT9040420 4 5 (4x(2x0,15))C 8,0 12,5Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreTel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery program8-pole Cross-OverPart No.Pre-assembledwith connectorcombinationNumber of coresand conductornominal crosssection [mm 2 ]ø [mm] BendingradiusCAT9040390 1 2 (4x(2x0,15))C 8,0 12,5CAT9040550 1 3 (4x(2x0,15))C 8,0 12,5CAT9040570 1 4 (4x(2x0,15))C 8,0 12,5CAT9040330 1 5 (4x(2x0,15))C 8,0 12,5CAT9040370 2 1 (4x(2x0,15))C 8,0 12,5CAT9040350 2 2 (4x(2x0,15))C 8,0 12,5CAT9040510 2 3 (4x(2x0,15))C 8,0 12,5CAT9040530 2 4 (4x(2x0,15))C 8,0 12,5CAT9040310 2 5 (4x(2x0,15))C 8,0 12,5CAT9040450 3 3 (4x(2x0,15))C 8,0 12,5CAT9040490 3 4 (4x(2x0,15))C 8,0 12,5CAT9040410 3 5 (4x(2x0,15))C 8,0 12,5CAT9040470 4 4 (4x(2x0,15))C 8,0 12,5CAT9040430 4 5 (4x(2x0,15))C 8,0 12,5Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)267


CAT6<strong>Chainflex</strong> ® network techniqueCAT6 <strong>cables</strong> harnessedTechnical informationn oil-resistantn UV-resistantn halogen-freen external jacket on the basis of TPEn Shield: extremely bending-resistant copper shieldwith greatest possible coverage over aluminiumcoatedplastic foil.n Temperature range (moved): -35 °C to +70 °C<strong>Chainflex</strong> ® -TPE Energy Chains ® Ethernet special cableDelivery program igus ®Part No.Number of coresand conductornominal crosssection [mm 2 ]ø [mm]BendingradiusCAT6 – 8 poleStraight CAT9040600 (4x(2x0.14)C)C 10.0 12,5 x dCAT6 – 8 poleStraight CAT9040640 (4x(2x0.14)C)C 10.0 12,5 x dCAT6 – 8 poleStraight CAT9040680 (4x(2x0.14)C)C 10.0 12,5 x dNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreNetwork technique268... no minimum order quantity


12.5xCAT6n Minimum bending radius for use in Energy Chains ® :12.5 x cable diametern Colour: Red lilac (similar to RAL 4001)<strong>Chainflex</strong> ® -TPE Energy Chains ® Ethernet special cable<strong>Chainflex</strong> ®network techniqueDelivery program igus ®Part No.Number of coresand conductornominal crosssection [mm 2 ]ø [mm]BendingradiusCAT6 – 8 poleCross-Over CAT9040620 (4x(2x0.14)C)C 10.0 12,5 x dTel. +49-2203-96 49-0Fax +49-2203-96 49-222CAT6 – 8 poleCross-Over CAT9040660 (4x(2x0.14)C)C 10.0 12,5 x dCAT6 – 8 poleCross-Over CAT9040700 (4x(2x0.14)C)C 10.0 12,5 x dNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)269


ProfibusPVC<strong>Chainflex</strong> ® network techniqueProfibus <strong>cables</strong> pre-assembledTechnical informationn Oil-resistantn UV-resistantn Flame-retardantn External jacket on the basis of PVCn Total shield: bending-resistant, tinned braided copper shield.Coverage approx. 55 % linear, approx. 80 % optical.n Minimum bending radius for use in Energy Chains ® :12.5 x cable diameter<strong>Chainflex</strong> ® -PVC Profibus special cableConnector 01Connector 02M12, 5-pole socket, straightM12, 5-pole pin, straightConnector 03M12, 5-pole pin, angledConnector 04M12, 5-pole socket, angledConnector 05M12, 5-pole socket, angledConnector 06M12, 5-pole pin, angledConnector 07*D-SUB, 9-pole pin, straightConnector 08*SUB-D, 9-pole pin, 90°, End plugConnector 09*SUB-D, 9-pole pin, 45°, IP67Connector 10*SUB-D, 9-pole pin, End plug, 45°Network technique270Connector 11*Connector 12*Connector 13SUB-D, 9-pole socket/pin, pass, angled 45°SUB-D, 9-pole socket/pin, pass, angled 90°open end of cable* Plugs with IN and OUT connection always will be connected on the IN side if the cable is assembled.More combinations on request.... no minimum order quantity


ProfibusPVCn Temperatur range (moved): -5 °C to +70 °C followingDIN EN 60811, part 1-4 chapter 8.2, +5 °C to +70 °Cfor use in Energy Chains ® with > 50.000 cyclen Colour: Red lilac (similar to RAL 4001)<strong>Chainflex</strong> ® -PVC Profibus special cable<strong>Chainflex</strong> ®network techniqueDelivery programPart No.Pre-assembledwith connectorcombinationNumber of coresand conductornominal crosssection [mm 2 ]ø [mm]BendingradiusBUS9041004 1 1 (2x0,25)C 8,0 12,5BUS9041001 1 2 (2x0,25)C 8,0 12,5BUS9041011 1 5 (2x0,25)C 8,0 12,5BUS9041006 1 6 (2x0,25)C 8,0 12,5BUS9041005 1 13 (2x0,25)C 8,0 12,5BUS9041002 2 2 (2x0,25)C 8,0 12,5BUS9041013 2 5 (2x0,25)C 8,0 12,5BUS9041007 2 6 (2x0,25)C 8,0 12,5BUS9041054 2 7 (2x0,25)C 8,0 12,5BUS9041059 2 8 (2x0,25)C 8,0 12,5BUS9041062 2 9 (2x0,25)C 8,0 12,5BUS9041055 2 10 (2x0,25)C 8,0 12,5BUS9041003 2 13 (2x0,25)C 8,0 12,5BUS9041066 3 4 (2x0,25)C 8,0 12,5BUS9041064 3 13 (2x0,25)C 8,0 12,5BUS9041065 4 13 (2x0,25)C 8,0 12,5BUS9041014 5 5 (2x0,25)C 8,0 12,5BUS9041010 5 6 (2x0,25)C 8,0 12,5BUS9041012 5 13 (2x0,25)C 8,0 12,5BUS9041009 6 6 (2x0,25)C 8,0 12,5BUS9041008 6 13 (2x0,25)C 8,0 12,5BUS9041053 7 IN 2/OUT 1 (2x0,25)C 8,0 12,5BUS9041056 7 13 (2x0,25)C 8,0 12,5BUS9041061 8 IN 2/OUT 1 (2x0,25)C 8,0 12,5BUS9041060 9 IN 2/OUT 1 (2x0,25)C 8,0 12,5BUS9041063 9 13 (2x0,25)C 8,0 12,5BUS9041052 10 IN 2/OUT 1 (2x0,25)C 8,0 12,5BUS9041057 10 13 (2x0,25)C 8,0 12,5BUS9041058 11 IN 13/OUT 13 (2x0,25)C 8,0 12,5BUS9041051 12 IN 2/OUT 1 (2x0,25)C 8,0 12,5Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...(for up to 10 cuts of the same type)271


ProfibusPUR<strong>Chainflex</strong> ® network techniqueProfibus <strong>cables</strong> pre-assembledTechnical informationn Oil-resistant and coolant-resistantn UV-resistantn Flame-retardantn External jacket on the basis of PURn Total shield: bending-resistant, tinned braided coppershield. Coverage approx. 55 % linear, approx. 80 % optical.n Minimum bending radius for use in Energy Chains ® :12.5 x cable diameter<strong>Chainflex</strong> ® -PUR Profibus special cableConnector 01Connector 02M12, 5-pole socket, straightM12, 5-pole pin, straightConnector 03M12, 5-pole pin, angledConnector 04M12, 5-pole socket, angledConnector 05M12, 5-pole socket, angledConnector 06M12, 5-pole pin, angledConnector 07*D-SUB, 9-pole pin, straightConnector 08*SUB-D, 9-pole pin, 90°, End plugConnector 09*SUB-D, 9-pole pin, 45°, IP67Connector 10*SUB-D, 9-pole pin, End plug, 45°Network technique272Connector 11*Connector 12*Connector 13SUB-D, 9-pole socket/pin, pass, angled 45°SUB-D, 9-pole socket/pin, pass, angled 90°open end of cable* Plugs with IN and OUT connection always will be connected on the IN side if the cable is assembled.More combinations on request.... no minimum order quantity


ProfibusPURn Temperature range (moved): -35 °C to +70 °Cn Colour: Red lilac (similar to RAL 4001)<strong>Chainflex</strong> ® -PUR Profibus special cable<strong>Chainflex</strong> ®network techniqueDelivery programPart No.Pre-assembledwith connectorcombinationNumber of coresand conductornominal crosssection [mm 2 ]ø [mm]BendingradiusBUS9041104 1 1 (2x0,25)C 8,0 12,5BUS9041101 1 2 (2x0,25)C 8,0 12,5BUS9041111 1 5 (2x0,25)C 8,0 12,5BUS9041106 1 6 (2x0,25)C 8,0 12,5BUS9041105 1 13 (2x0,25)C 8,0 12,5BUS9041102 2 2 (2x0,25)C 8,0 12,5BUS9041113 2 5 (2x0,25)C 8,0 12,5BUS9041107 2 6 (2x0,25)C 8,0 12,5BUS9041154 2 7 (2x0,25)C 8,0 12,5BUS9041159 2 8 (2x0,25)C 8,0 12,5BUS9041162 2 9 (2x0,25)C 8,0 12,5BUS9041155 2 10 (2x0,25)C 8,0 12,5BUS9041103 2 13 (2x0,25)C 8,0 12,5BUS9041166 3 4 (2x0,25)C 8,0 12,5BUS9041164 3 13 (2x0,25)C 8,0 12,5BUS9041165 4 13 (2x0,25)C 8,0 12,5BUS9041114 5 5 (2x0,25)C 8,0 12,5BUS9041110 5 6 (2x0,25)C 8,0 12,5BUS9041112 5 13 (2x0,25)C 8,0 12,5BUS9041109 6 6 (2x0,25)C 8,0 12,5BUS9041108 6 13 (2x0,25)C 8,0 12,5BUS9041153 7 IN 2/OUT 1 (2x0,25)C 8,0 12,5BUS9041156 7 13 (2x0,25)C 8,0 12,5BUS9041161 8 IN 2/OUT 1 (2x0,25)C 8,0 12,5BUS9041160 9 IN 2/OUT 1 (2x0,25)C 8,0 12,5BUS9041163 9 13 (2x0,25)C 8,0 12,5BUS9041152 10 IN 2/OUT 1 (2x0,25)C 8,0 12,5BUS9041157 10 13 (2x0,25)C 8,0 12,5BUS9041158 11 IN 13/OUT 13 (2x0,25)C 8,0 12,5BUS9041151 12 IN 2/OUT 1 (2x0,25)C 8,0 12,5Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...(for up to 10 cuts of the same type)273


ProfibusTPE<strong>Chainflex</strong> ® network techniqueProfibus <strong>cables</strong> pre-assembledTechnical informationn Oil-resistantn UV-resistantn Flame-retardantn External jacket on the basis of TPEn Total shield:Extrem bending-resistant, tinned braided coppershield. Coverage approx. 70% linear, approx. 90% optical.n Minimum bending radius for use in Energy Chains ® :10-12.5 x cable diameter<strong>Chainflex</strong> ® -TPE Profibus special cableConnector 01Connector 02M12, 5-pole socket, straightM12, 5-pole pin, straightConnector 03M12, 5-pole pin, angledConnector 04M12, 5-pole socket, angledConnector 05M12, 5-pole socket, angledConnector 06M12, 5-pole pin, angledConnector 07*D-SUB, 9-pole pin, straightConnector 08*SUB-D, 9-pole pin, 90°, End plugConnector 09*SUB-D, 9-pole pin, 45°, IP67Connector 10*SUB-D, 9-pole pin, End plug, 45°Network technique274Connector 11*Connector 12*Connector 13SUB-D, 9-pole socket/pin, pass, angled 45°SUB-D, 9-pole socket/pin, pass, angled 90°open end of cable* Plugs with IN and OUT connection always will be connected on the IN side if the cable is assembled.More combinations on request.... no minimum order quantity


ProfibusTPEn Temperature range (moved): -35 °C to +70 °Cn Colour: Red lilac (similar to RAL 4001)<strong>Chainflex</strong> ® -TPE Profibus special cable<strong>Chainflex</strong> ®network techniqueDelivery programPart No.Pre-assembledwith connectorcombinationNumber of coresand conductornominal crosssection [mm 2 ]ø [mm]BendingradiusBUS9041204 1 1 (2x0,25)C 8,0 12,5BUS9041201 1 2 (2x0,25)C 8,0 12,5BUS9041211 1 5 (2x0,25)C 8,0 12,5BUS9041206 1 6 (2x0,25)C 8,0 12,5BUS9041205 1 13 (2x0,25)C 8,0 12,5BUS9041202 2 2 (2x0,25)C 8,0 12,5BUS9041213 2 5 (2x0,25)C 8,0 12,5BUS9041207 2 6 (2x0,25)C 8,0 12,5BUS9041254 2 7 (2x0,25)C 8,0 12,5BUS9041259 2 8 (2x0,25)C 8,0 12,5BUS9041262 2 9 (2x0,25)C 8,0 12,5BUS9041255 2 10 (2x0,25)C 8,0 12,5BUS9041203 2 13 (2x0,25)C 8,0 12,5BUS9041266 3 4 (2x0,25)C 8,0 12,5BUS9041264 3 13 (2x0,25)C 8,0 12,5BUS9041265 4 13 (2x0,25)C 8,0 12,5BUS9041214 5 5 (2x0,25)C 8,0 12,5BUS9041210 5 6 (2x0,25)C 8,0 12,5BUS9041212 5 13 (2x0,25)C 8,0 12,5BUS9041209 6 6 (2x0,25)C 8,0 12,5BUS9041208 6 13 (2x0,25)C 8,0 12,5BUS9041253 7 IN 2/OUT 1 (2x0,25)C 8,0 12,5BUS9041256 7 13 (2x0,25)C 8,0 12,5BUS9041261 8 IN 2/OUT 1 (2x0,25)C 8,0 12,5BUS9041260 9 IN 2/OUT 1 (2x0,25)C 8,0 12,5BUS9041263 9 13 (2x0,25)C 8,0 12,5BUS9041252 10 IN 2/OUT 1 (2x0,25)C 8,0 12,5BUS9041257 10 13 (2x0,25)C 8,0 12,5BUS9041258 11 IN 13/OUT 13 (2x0,25)C 8,0 12,5BUS9041251 12 IN 2/OUT 1 (2x0,25)C 8,0 12,5Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth coreTel. +49-2203-96 49-0Fax +49-2203-96 49-222950 types from stock no cutting costs ...(for up to 10 cuts of the same type)275


F.INInitiators


<strong>Chainflex</strong> ® ReadyCable ®Initiators CF9 - CF.INI (minimum bending radius 5 x d)Cable type Jacket PageDirect line M12 x 1, straight/angled TPE 260Direct line M12 x 1, straight/angled, LED TPE 261Connecting cable M12 x 1, straight/angled TPE 262Direct line M8 x 1, straight/angled TPE 263Direct line M8 x 1, angled, LED TPE 264Connecting cable M8 x 1, straight/angled TPE 265Initiators CF10 – CF.INI (minimum bending radius 5 x d) 360° shieldedDirect line M12 x 1, straight/angled TPE 266Initiators CF98 - CF.INI (minimum bending radius 4 x d)Connecting cable M12 x 1, straight/angled TPE 267Direct line M12 x 1, straight/angled TPE 268Connecting cable M12 x 1, straight/angled TPE 269Direct line M8 x 1, straight/angled TPE 270Connecting cable M8 x 1, straight/angled TPE 271277


CF.INICF9CF.INI<strong>Chainflex</strong> ® Sensor/actuator <strong>cables</strong> with 5xd for Energy Chains ®Direct line M12 x 1:Socket with free cable endPlug-type connector Coupling, M12 x 1Handle basePlastic, PP, blackUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, PP, blackContactsMetal, CuZn, gold-platedSealPlastic, FPM (Viton)Number of polesAmpacityRated voltage of a windingNumber of polesAmpacityRated voltage of a winding4-pole4 Amax. 250 VInsulation resistance ≥10 9 ΩContact resistance≤5 m ΩDegree of soiling 3/25-pole (4-pole + PE)4 Amax. 60 VAmbient temperature ofplug-type connector -40...+105 °CProtection classIP69K, in screwed stateMechanical service life max. 100 insertion cyclesø 15ø 10,2ø 11,6 122 WH1 BN 3 BU1 BNBG4 BK2 WHM12 x 1423 BUM12 x 1ø 15ø 8,8ø 11,62 WH1 BN 3 BU1 BNBW26,54 BK2 WH123 BU31,55 GY4 BK5 GY4 BKCF9.03.04.INI* (4 x 0.34)Part No. Number of Cable lengthTypepoles [m]CF.INI-P4-M12-BG-3 MAT9043700 4 3.0CF.INI-P4-M12-BG-5 MAT9043701 4 5.0CF.INI-P4-M12-BG-7 MAT9043702 4 7.0CF.INI-P4-M12-BG-10 MAT9043703 4 10.0CF.INI-P4-M12-BG-15 MAT9049426 4 15.0CF9.03.05.INI* (5 x 0.34)CF.INI-P5-M12-BG-3 MAT9043737 5 3.0CF.INI-P5-M12-BG-5 MAT9043738 5 5.0CF.INI-P5-M12-BG-7 MAT9043739 5 7.0CF.INI-P5-M12-BG-10 MAT9043740 5 10.0CF.INI-P5-M12-BG-15 MAT90410077 5 15.0Sensor/actuator <strong>cables</strong>278CF9.03.04.INI* (4 x 0.34)CF.INI-P4-M12-BW-3 MAT9043704 4 3.0CF.INI-P4-M12-BW-5 MAT9043705 4 5.0CF.INI-P4-M12-BW-7 MAT9043706 4 7.0CF.INI-P4-M12-BW-10 MAT9043707 4 10.0CF.INI-P4-M12-BW-15 MAT9049430 4 15.0CF9.03.05.INI* (5 x 0.34)CF.INI-P5-M12-BW-3 MAT9043742 5 3.0CF.INI-P5-M12-BW-5 MAT9043743 5 5.0CF.INI-P5-M12-BW-7 MAT9043744 5 7.0CF.INI-P5-M12-BW-10 MAT9043745 5 10.0CF.INI-P5-M12-BW-15 MAT90410078 5 15.0* Technical information page 80... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


5xCF.INICF9Direct line M12 x 1:Socket with LED and free cable endPlug-type connector Coupling, M12 x 1Handle basePlastic, TPU, transparentUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, PA6GF, transparentContactsMetal, CuZn, gold-platedSealPlastic, FPM(Viton)Number of polesAmpacityRated voltage of a winding4-pole4 A10...30 Vø 15LEDBGLø 10,2ø 11,6 12M12 x 145,5M12 x 1ø 15ø 8,8ø 11,6BWL26,51231,5LEDs<strong>Chainflex</strong> ®Insulation resistance ≥10 9 ΩContact resistance≤5 m ΩDegree of soiling 3/2Operating voltage display LED greenSwitching state display LED yellow/yellowSwitching functionpnpAmbient temperature ofplug-type connector -40...+105 °CProtection classIP66, in screwed stateMechanical service life max.100 insertion cycles2 WH1 BN 3 BU4 BKBN1 +GNBK4YEWH2BU3 –2 WH1 BN 3 BU4 BKBN1 +GNWH4YEBK2YEBU3 –Tel. +49-2203-96 49-0Fax +49-2203-96 49-222CF9.03.04.INI* (4 x 0.34)Part No. Number of Cable lengthTypepoles [m]CF.INI-P4-M12-BGL2-3 MAT9043708 4 3.0CF.INI-P4-M12-BGL2-5 MAT9043709 4 5.0CF.INI-P4-M12-BGL2-7 MAT9043710 4 7.0CF.INI-P4-M12-BGL2-10 MAT9043711 4 10.0CF.INI-P4-M12-BGL2-15 MAT90410087 4 15.0CF9.03.04.INI* (4 x 0.34)CF.INI-P4-M12-BWL3-3 MAT9043712 4 3.0CF.INI-P4-M12-BWL3-5 MAT9043713 4 5.0CF.INI-P4-M12-BWL3-7 MAT9043714 4 7.0CF.INI-P4-M12-BWL3-10 MAT9043715 4 10.0CF.INI-P4-M12-BWL3-15 MAT90410088 4 15.0* Technical information page 80950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFINI(for up to 10 cuts of the same type)279


CF.INICF9CF.INI<strong>Chainflex</strong> ® Sensor/actuator <strong>cables</strong> with 5xd for Energy Chains ®Connection cable M12 x 1:Socket, cable end with pinPlug-type connector Coupling, M12 x 1Handle basePlastic, PP, blackUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, PP, blackContactsMetal, CuZn, gold-platedSealPlastic, FPM(Viton)Plug-type connector Connector, M12 x 1Handle basePlastic, PP, blackUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, TPU, blackContactsMetal, CuZn, gold-platedø 15ø 10,2ø 11,6 12BG SG BWM12 x 142M12 x 1ø 15ø 10,2ø 11,6 1252M12 x 1ø 15ø 8,8ø 11,626,51231,5Rated voltage of a winding 4-pole: max. 250 V5-pole (4-pole+PE): max. 60 V2 WHAmpacity4 AInsulation resistance ≥10 9 Ω1 BN 3 BUContact resistance≤5 m ΩDegree of soiling 3/24 BK3 BU2 WH4 BK1 BN2 WH1 BN 3 BU4 BKAmbient temperature ofplug-type connector -40...+105 °CProtection classIP69K, in screwed stateMechanical service life max. 100 insertion cycles1 BN5 GY2 WH4 BK3 BU3 BU5 GY2 WH4 BK1 BN1 BN5 GY2 WH4 BK3 BUCF9.03.04.INI* (4 x 0.34)Part No. Number of Cable lengthTypepoles [m]CF.INI-P4-M12-BG / M12-SG-2 MAT90410312 4 2.0CF.INI-P4-M12-BG / M12-SG-5 MAT90410313 4 5.0CF.INI-P4-M12-BG / M12-SG-10 MAT90410314 4 10.0CF9.03.05.INI* (5 x 0.34)CF.INI-P5-M12-BG / M12-SG-2 MAT90410339 5 2.0CF.INI-P5-M12-BG / M12-SG-5 MAT90410340 5 5.0CF.INI-P5-M12-BG / M12-SG-10 MAT90410341 5 10.0Sensor/actuator <strong>cables</strong>280CF9.03.04.INI* (4 x 0.34)CF.INI-P4-M12-BW / M12-SG-2 MAT90410315 4 2.0CF.INI-P4-M12-BW / M12-SG-5 MAT90410316 4 5.0CF.INI-P4-M12-BW / M12-SG-10 MAT90410317 4 10.0CF9.03.05.INI* (5 x 0.34)CF.INI-P5-M12-BW / M12-SG-2 MAT90410342 5 2.0CF.INI-P5-M12-BW / M12-SG-5 MAT90410343 5 5.0CF.INI-P5-M12-BW / M12-SG-10 MAT90410344 5 10.0* Technical information page 80... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


5xCF.INICF9Direct line M8 x 1:Socket with free cable endPlug-type connector Coupling, M8 x 1Handle basePlastic, PP, blackUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, PP, blackContactsMetal, CuZn, gold-platedSealPlastic, FPM(Viton)Number of polesAmpacityRated voltage of a winding3-pole4 Amax. 60 Vø 9,6BG34M8 x 1M8 x 1ø 9,5BW16,528<strong>Chainflex</strong> ®Number of polesAmpacityRated voltage of a winding4-pole4 Amax. 30 V4 BK4 BKInsulation resistance ≥10 9 ΩContact resistance≤5 m ΩDegree of soiling 3/2Ambient temperature ofplug-type connector -40...+105 °CProtection classIP69K, in screwed stateMechanical service life max. 100 insertion cycles3 BU4 BK3 BU1 BN2 WH1 BN3 BU4 BK3 BU1 BN2 WH1 BNTel. +49-2203-96 49-0Fax +49-2203-96 49-222CF9.02.03.INI* (3 x 0.25)Part No. Number of Cable lengthTypepoles [m]CF.INI-P3-M8-BG-3 MAT9043716 3 3.0CF.INI-P3-M8-BG-5 MAT9043717 3 5.0CF.INI-P3-M8-BG-7 MAT9043718 3 7.0CF.INI-P3-M8-BG-10 MAT9043719 3 10.0CF.INI-P3-M8-BG-15 MAT9049416 3 15.0CF9.03.04.INI* (4 x 0.34)CF.INI-P4-M8-BG-3 MAT9043728 4 3.0CF.INI-P4-M8-BG-5 MAT9043729 4 5.0CF.INI-P4-M8-BG-7 MAT9043730 4 7.0CF.INI-P4-M8-BG-10 MAT9043731 4 10.0CF.INI-P4-M8-BG-15 MAT9049466 4 15.0CF9.02.03.INI* (3 x 0.25)CF.INI-P3-M8-BW-3 MAT9043724 3 3.0CF.INI-P3-M8-BW-5 MAT9043725 3 5.0CF.INI-P3-M8-BW-7 MAT9043726 3 7.0CF.INI-P3-M8-BW-10 MAT9043727 3 10.0CF.INI-P3-M8-BW-15 MAT9049419 3 15.0CF9.03.04.INI* (4 x 0.34)CF.INI-P4-M8-BW-3 MAT9043732 4 3.0CF.INI-P4-M8-BW-5 MAT9043733 4 5.0CF.INI-P4-M8-BW-7 MAT9043734 4 7.0CF.INI-P4-M8-BW-10 MAT9043735 4 10.0CF.INI-P4-M8-BW-15 MAT9049467 4 15.0* Technical information page 80950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFINI(for up to 10 cuts of the same type)281


CF.INICF9CF.INI<strong>Chainflex</strong> ® Sensor/actuator <strong>cables</strong> with 5xd for Energy Chains ®Direct line M8 x 1:Socket with LED and free cable endPlug-type connector Coupling, M8 x 1Handle basePlastic, TPU, transparentUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, PA6GF, blackContactsMetal, CuZn, gold-platedSealPlastic, FPM(Viton)Number of polesAmpacityRated voltage of a winding3-pole4 A10...30 VM8 x 1ø 9,6BWL16,523,5LED28,3Insulation resistance ≥10 9 ΩContact resistance≤5 m ΩDegree of soiling 3/24 BKOperating voltage displaySwitching state displaySwitching functionLED greenLED yellowpnp3 BU1 BNAmbient temperature ofplug-type connector -40...+105 °CProtection classIP66K, in screwed stateMechanical service life max. 100 insertion cycles1 +43 –YEGNBNBKBUCF9.02.03.INI* (3 x 0.25)TypePart No. Number ofpolesCable length[m]CF.INI-P3-M8-BWL2-3 MAT9043720 3 3.0CF.INI-P3-M8-BWL2-5 MAT9043721 3 5.0CF.INI-P3-M8-BWL2-7 MAT9043722 3 7.0CF.INI-P3-M8-BWL2-10 MAT9043723 3 10.0CF.INI-P3-M8-BWL2-15 MAT90410196 3 15.0* Technical information page 80Sensor/actuator <strong>cables</strong>282... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


5xCF.INICF9Connection cable M8 x 1:Socket, cable end with pinPlug-type connector Coupling, M8 x 1Handle basePlastic, PP, blackUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, PP, blackContactsMetal, CuZn, gold-platedSealPlastic, FPM(Viton)Plug-type connector Connector, M8 x 1Handle basePlastic, PP, blackUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, PP, blackContactsMetal, CuZn, gold-platedø 9,6BG SG BWM8 x 116,5M8 x 1M8 x 1ø 9,63441,2ø 9,528<strong>Chainflex</strong> ®Rated voltage of a winding 3-pole: max. 60 V4-pole: max. 30 VAmpacity4 AInsulation resistance ≥10 9 ΩContact resistance≤5 m ΩDegree of soiling 3/2Ambient temperature ofplug-type connector -40...+105 °CProtection classIP69K, in screwed stateMechanical service life max. 100 insertion cycles3 BU4 BK3 BU4 BK1 BN2 WH1 BN1 BN2 WH1 BN4 BK3 BU4 BK3 BU3 BU4 BK3 BU4 BK1 BN2 WH1 BNTel. +49-2203-96 49-0Fax +49-2203-96 49-222CF9.02.03.INI* (3 x 0.25)Part No. Number of Cable lengthTypepoles [m]CF.INI-P3-M8-BG / M8-SG-2 MAT90410324 3 2.0CF.INI-P3-M8-BG / M8-SG-5 MAT90410325 3 5.0CF.INI-P3-M8-BG / M8-SG-10 MAT90410326 3 10.0CF9.03.04.INI* (4 x 0.34)CF.INI-P4-M8-BG / M8-SG-2 MAT90410333 4 2.0CF.INI-P4-M8-BG / M8-SG-5 MAT90410334 4 5.0CF.INI-P4-M8-BG / M8-SG-10 MAT90410335 4 10.0CF9.02.03.INI* (3 x 0.25)CF.INI-P3-M8-BW / M8-SG-2 MAT90410330 3 2.0CF.INI-P3-M8-BW / M8-SG-5 MAT90410331 3 5.0CF.INI-P3-M8-BW / M8-SG-10 MAT90410332 3 10.0CF9.03.04.INI* (4 x 0.34)CF.INI-P4-M8-BW / M8-SG-2 MAT90410336 4 2.0CF.INI-P4-M8-BW / M8-SG-5 MAT90410337 4 5.0CF.INI-P4-M8-BW / M8-SG-10 MAT90410338 4 10.0* Technical information page 80950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFINI(for up to 10 cuts of the same type)283


CF.INICF10CF.INI<strong>Chainflex</strong> ® Sensor/actuator <strong>cables</strong> with 5xd for Energy Chains ®Direct line 360° shielded, M12 x 1:Socket with free cable endPlug-type connector Coupling, M12 x 1Handle basePlastic, PP, blackUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, PP, blackContactsMetal, CuZn, gold-platedSealPlastic, FPM(Viton)Number of polesAmpacityRated voltage of a windingInsulation resistance ≥10 9 ΩContact resistance≤5 m ΩDegree of soiling 3/25-pole (4-pole +PE)4 Amax. 60 Vø 15BGø 10,2ø 11,6 122 WHM12 x 142M12 x 1ø 15ø 8,8ø 11,6BW26,52 WH125x31,5Ambient temperature ofplug-type connector -40...+105 °CProtection classIP69K, in screwed stateMechanical service life max. 100 insertion cycles1 BN3 BU1 BN5 GY 4 BK5 GY 4 BKShieldedbrownwhiteblueblackgreen-yellow3 BUCF10.03.05.INI* (5 x 0,34)CPart No. Number of Cable lengthTypepoles [m]CF10.INI-P5-C-M12-BG-3 MAT90424072 5 3,0CF10.INI-P5-C-M12-BG-5 MAT90424073 5 5,0CF10.INI-P5-C-M12-BG-7 MAT90424074 5 7,0CF10.INI-P5-C-M12-BG-10 MAT90424075 5 10,0CF10.INI-P5-C-M12-BG-15 MAT90424076 5 15,0Sensor/actuator <strong>cables</strong>284CF10.03.05.INI* (5 x 0,34)CCF10.INI-P5-C-M12-BW-3 MAT90424077 5 3,0CF10.INI-P5-C-M12-BW-5 MAT90424078 5 5,0CF10.INI-P5-C-M12-BW-7 MAT90424079 5 7,0CF10.INI-P5-C-M12-BW-10 MAT90424080 5 10,0CF10.INI-P5-C-M12-BW-15 MAT90424081 5 15,0* Technical information page 84... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


CF.INI<strong>Chainflex</strong> ® Sensor/actuator <strong>cables</strong> with 5xd for Energy Chains ®Connection cable 360° shielded, M12 x 1:Socket, cable end with pinPlug-type connector Coupling, M12 x 1 BG SG BWHandle baseUnion nut/screwContact baseContactsSealNumber of polesAmpacityRated voltage of a windingPlastic, PP, blackMetal, CuZn, nickel-platedPlastic, PP, blackMetal, CuZn, gold-platedPlastic, FPM(Viton)5-pole (4-pole +PE)4 Amax. 60 Vø 15ø 10,2ø 11,6 12M12 x 142M12 x 1ø 15ø 10,2ø 11,6 1252M12 x 1ø 15ø 8,8ø 11,626,55x1231,5CF.INICF10<strong>Chainflex</strong> ®Insulation resistance ≥10 9 ΩContact resistance≤5 m ΩDegree of soiling 3/2Ambient temperature ofplug-type connector -40...+105 °CProtection classIP69K, in screwed stateMechanical service life max. 100 insertion cycles1 BN5 GY2 WH4 BK3 BU3 BU5 GY2 WH4 BKbrownwhiteblueblackgreen-yellowShielded1 BN1 BN5 GY2 WH4 BK3 BUTel. +49-2203-96 49-0Fax +49-2203-96 49-222CF10.03.05.INI* (5 x 0,34)CPart No. Number of Cable lengthTypepoles [m]CF10.INI-P5-C-M12-BG/M12-SG-2 MAT90424082 5 2,0CF10.INI-P5-C-M12-BG/M12-SG-5 MAT90424083 5 5,0CF10.INI-P5-C-M12-BG/M12-SG-10 MAT90424084 5 10,0CF10.03.05.INI* (5 x 0,34)CCF10.INI-P5-C-M12-BW/M12-SG-2 MAT90424085 5 2,0CF10.INI-P5-C-M12-BW/M12-SG-5 MAT90424086 5 5,0CF10.INI-P5-C-M12-BW/M12-SG-10 MAT90424087 5 10,0* Technical information page 84950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFINI(for up to 10 cuts of the same type)285


CF.INICF98CF.INI<strong>Chainflex</strong> ® Sensor/actuator <strong>cables</strong> with 4xd for Energy Chains ®Direct line M12 x 1:Socket with free cable endPlug-type connector Coupling, M12 x 1Handle basePlastic, PP, blackUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, PP, blackContactsMetal, CuZn, gold-platedSealPlastic, FPM(Viton)Number of polesAmpacityRated voltage of a winding4-pole4 Amax. 250 VInsulation resistance ≥10 9 ΩContact resistance≤5 m ΩDegree of soiling 3/2ø 15BGø 10,2ø 11,6 12M12 x 142M12 x 1ø 15ø 8,8ø 11,6BW26,51231,5Ambient temperature ofplug-type connector -40...+105 °CProtection classIP69K, in screwed stateMechanical service life max. 100 insertion cycles2 WH1 BN 3 BU4 BK2 WH1 BN 3 BU4 BKCF98.03.04.INI* (4 x 0.34)Part No. Number of Cable lengthTypepoles [m]CF98.INI-P4-M12-BG-3 MAT90410235 4 3.0CF98.INI-P4-M12-BG-5 MAT90410236 4 5.0CF98.INI-P4-M12-BG-7 MAT90410237 4 7.0CF98.INI-P4-M12-BG-10 MAT90410238 4 10.0CF98.INI-P4-M12-BG-15 MAT90410239 4 15.0Sensor/actuator <strong>cables</strong>286CF98.03.04.INI* (4 x 0.34)CF98.INI-P4-M12-BW-3 MAT90410240 4 3.0CF98.INI-P4-M12-BW-5 MAT90410241 4 5.0CF98.INI-P4-M12-BW-7 MAT90410242 4 7.0CF98.INI-P4-M12-BW-10 MAT90410243 4 10.0CF98.INI-P4-M12-BW-15 MAT90410244 4 15.0* Technical information page 96... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


4xCF.INICF98Connection cable M12 x 1:Socket, cable end with pinPlug-type connector Coupling, M12 x 1Handle basePlastic, PP, blackUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, TPU, blackContactsMetal, CuZn, gold-platedSealPlastic, FPM(Viton)Plug-type connectorHandle baseUnion nut/screwContact baseContactsConnector, M12x1Plastic, PP, blackMetal, CuZn, nickel-platedPlastic, TPU, blackMetal, CuZn, gold-platedø 15ø 10,2ø 11,6 12BG SG BWM12 x 1M12 x 142ø 15ø 10,2ø 11,6 1252M12 x 1ø 15ø 8,8ø 11,626,51231,5<strong>Chainflex</strong> ®Rated voltage of a winding 4-pole: max. 250VAmpacity4AInsulation resistance ≥10 9 ΩContact resistance≤5 m ΩDegree of soiling 3/2Ambient temperature ofplug-type connector -40...+105 °CProtection classIP69K, in screwed stateMechanical service life max.100 insertion cycles2 WH1 BN 3 BU4 BK3 BU2 WH4 BK1 BN2 WH1 BN 3 BU4 BKTel. +49-2203-96 49-0Fax +49-2203-96 49-222CF98.03.04.INI* (4 x 0.34)Part No. Number of Cable lengthTypepoles [m]CF98.INI-P4-M12-BG / M12-SG-2 MAT90410300 4 2.0CF98.INI-P4-M12-BG / M12-SG-5 MAT90410301 4 5.0CF98.INI-P4-M12-BG / M12-SG-10 MAT90410302 4 10.0CF98.03.04.INI* (4 x 0.34)CF98.INI-P4-M12-BW / M12-SG-2 MAT90410303 4 2.0CF98.INI-P4-M12-BW / M12-SG-5 MAT90410304 4 5.0CF98.INI-P4-M12-BW / M12-SG-10 MAT90410305 4 10.0* Technical information page 96950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFINI(for up to 10 cuts of the same type)287


CF.INICF98CF.INI<strong>Chainflex</strong> ® Sensor/actuator <strong>cables</strong> with 4xd for Energy Chains ®Direct line M8 x 1:Socket with free cable endPlug-type connector Coupling, M8 x 1Handle basePlastic, PP, blackUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, PP, blackContactsMetal, CuZn, gold-platedSealPlastic, FPM(Viton)Number of polesAmpacityRated voltage of a winding3-pole4 Amax. 60 VInsulation resistance ≥10 9 ΩContact resistance≤5 m ΩDegree of soiling 3/2Ambient temperature ofplug-type connector -40...+105 °CProtection classIP69K, in screwed stateMechanical service life max. 100 insertion cyclesø 15ø 10,2ø 11,6 123 BUBG4 BKM12 x 142M8 xø 9,51 BN 3 BUBW4 BK16,51 BN28CF98.02.03.INI* (3 x 0.25)Part No. Number of Cable lengthTypepoles [m]CF98.INI-P3-M8-BG-3 MAT90410245 3 3.0CF98.INI-P3-M8-BG-5 MAT90410246 3 5.0CF98.INI-P3-M8-BG-7 MAT90410247 3 7.0CF98.INI-P3-M8-BG-10 MAT90410248 3 10.0CF98.INI-P3-M8-BG-15 MAT90410249 3 15.0Sensor/actuator <strong>cables</strong>288CF98.02.03.INI* (3 x 0.25)CF98.INI-P3-M8-BW-3 MAT90410250 3 3.0CF98.INI-P3-M8-BW-5 MAT90410251 3 5.0CF98.INI-P3-M8-BW-7 MAT90410252 3 7.0CF98.INI-P3-M8-BW-10 MAT90410253 3 10.0CF98.INI-P3-M8-BW-15 MAT90410254 3 15.0* Technical information page 96... no minimum order quantityeplan download, configurator, PDF catalogues, lifetime ...


4xCF.INICF98Connection cable M8 x 1:Socket, cable end with pinPlug-type connector Coupling, M8 x 1Handle basePlastic, PP, blackUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, TPU, blackContactsMetal, CuZn, gold-platedSealPlastic, FPM(Viton)Plug-type connector Connector, M8 x 1Handle basePlastic, PP, blackUnion nut/screwMetal, CuZn, nickel-platedContact basePlastic, PP, blackContactsMetal, CuZn, gold-platedø 9,6BG SG BWM8 x 116,5M8 x 1M8 x 1ø 9,63441,2ø 9,528<strong>Chainflex</strong> ®Rated voltage of a winding 3-pole: max. 60 VAmpacity4A4 BK4 BKInsulation resistance ≥10 9 ΩContact resistance≤5 m Ω3 BU 1 BN 1 BN 3 BU 3 BUDegree of soiling 3/2Ambient temperature ofplug-type connector -40...+105 °CProtection classIP69K, in screwed stateMechanical service life max. 100 insertion cyclesCF98.02.03.INI* (3 x 0.25)Part No. Number of Cable lengthTypepoles [m]CF98.INI-P3-M8-BG / M8-SG-2 MAT90410306 3 2.0CF98.INI-P3-M8-BG / M8-SG-5 MAT90410307 3 5.0CF98.INI-P3-M8-BG / M8-SG-10 MAT90410308 3 10.04 BK1 BNTel. +49-2203-96 49-0Fax +49-2203-96 49-222CF98.02.03.INI* (3 x 0.25)CF98.INI-P3-M8-BW / M8-SG-2 MAT90410309 3 2.0CF98.INI-P3-M8-BW / M8-SG-5 MAT90410310 3 5.0CF98.INI-P3-M8-BW / M8-SG-10 MAT90410311 3 10.0* Technical information page 96950 types from stock no cutting costs ...... and order online www.igus.eu/en/CFINI(for up to 10 cuts of the same type)289


290


ive technology291


Content<strong>Chainflex</strong> ® ReadyCable ®Cables for Drive TechnologySelection table according to systems (Part No. and sheath materials) Jacket PageB&R igus.eu/en/CFBR PVC/PUR/TPE 294Baumüller igus.eu/en/CFBAUMUELLER PVC/PUR/TPE 294Beckhoff igus.eu/en/CFBECKHOFF PVC/PUR/TPE 296Berger Lahr igus.eu/en/CFBERGERLAHR PVC/PUR/TPE 296Control Techniques igus.eu/en/CFCONTROLTECHNIQUES PVC/PUR/TPE 297Danaher Motion igus.eu/en/CFDANAHER PVC/PUR/TPE 298ELAU igus.eu/en/CFELAU PVC/PUR/TPE 300Fagor igus.eu/en/CFFAGOR TPE 301Fanuc igus.eu/en/CFFANUC PUR/TPE 301Heidenhain igus.eu/en/CFHEIDENHAIN PUR/TPE 301Lenze igus.eu/en/CFLENZE PVC/PUR/TPE 302NUM igus.eu/en/CFNUM PVC/PUR/TPE 303Rexroth igus.eu/en/CFREXROTH PVC/PUR/TPE 303SEW igus.eu/en/CFSEW PVC/PUR/TPE 305Siemens igus.eu/en/CFSIEMENS PVC/PUR/TPE 306Stöber igus.eu/en/CFSTOEBER PVC/PUR/TPE 307To make the choice easier for you, we have classified all <strong>Chainflex</strong> ® -<strong>cables</strong> according tothe criteria "requirements, oil-resistance and travel distance". For this reason we haveextended the “Technical specifications” by the specification “Class 6.3.3”, for example.For detailed information see the inside of the front cover flap.292


<strong>Chainflex</strong> ® ReadyCable ® 293Cables for Drive Technology<strong>Chainflex</strong> ® PVC <strong>cables</strong> for the woodworking industry, for exampleTypical application area – PVCn for high load requirementsn light oil influencen preferably indoor applications, but also outdoor ones attemperatures > 5 °Cn especially for freely suspended and gliding travel distances upto 100 mn Storage and retrieval units for high-bay warehouses, machiningunits/packaging machines, quick handling, indoor cranes, timberprocessing<strong>Chainflex</strong> ® PUR <strong>cables</strong> for the tooling machine industry, for exampleTypical application area – PURn for maximum load requirementsn almost unlimited resistance to oiln Indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances upto 100 mn Storage and retrieval units for high-bay warehouses, machiningunits/machine tools, quick handling, clean room, semiconductorinsertion, outdoor cranes, low-temperature applications<strong>Chainflex</strong> ® TPE <strong>cables</strong> for outdoor use, for exampleTypical application area – TPEn for maximum load requirementsn almost unlimited resistance to oil, also with bio-oilsn Indoor and outdoor applications, UV-resistantn especially for freely suspended and gliding travel distances up to400 m and moren Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion,ship to shore, outdoor cranes, low-temperature applicationsOur product engineers will be happy to advise you in your choice of application-specific <strong>cables</strong>.293


Content<strong>Chainflex</strong> ® ReadyCable ®294B&RBAUMÜLLERB&R – Selection table according to part numbers and sheath materials.Connection cablei8CMxxx.12-1 308 326i8CMxxx.12-3 308 326i8CMxxx.12-5 308 326i8CRxxx.12-1 356 378Extension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPEi8CExxx.12-1 360 380Baumüller – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cableExtension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE198962 (3 m) 360 380 Pulse encoder 361 381198963 (5 m) 360 380 Pulse encoder 361 381198964 (8 m) 361 381 Pulse encoder 361 381198965 (10 m) 361 381 Pulse encoder 361 381198966 (15 m) 361 381 Pulse encoder 361 381198967 (10 m) 361 381 Pulse encoder 361 381198968 (25 m) 361 381 Pulse encoder 361 381198969 (30 m) 361 381 Pulse encoder 361 381208829 (40 m) 361 381 Pulse encoder 361 381225360 (35 m) 361 381 Pulse encoder 361 381239540 (5 m) 360 380 Resolver / SKS / SKM 360 380239541 (8 m) 360 380 Resolver / SKS / SKM 360 380239542 (10 m) 360 380 Resolver / SKS / SKM 360 380239543 (15 m) 360 380 Resolver / SKS / SKM 360 380239544 (20m) 360 380 Resolver / SKS / SKM 360 380239545 (25 m) 360 380 Resolver / SKS / SKM 360 380239546 (30 m) 360 380 Resolver / SKS / SKM 360 380239547 (35 m) 360 380 Resolver / SKS / SKM 360 380240520 (40 m) 360 380 Resolver / SKS / SKM 360 380240521 (45 m) 360 380 Resolver / SKS / SKM 360 380240522 (50 m) 360 380 Resolver / SKS / SKM 360 380242954 (6 m) 360 380 Resolver / SKS / SKM 360 380243379 (4 m) 360 380 Resolver / SKS / SKM 360 380244033 (55 m) 360 380 Resolver / SKS / SKM 360 380245484 (60 m) 360 380 Resolver / SKS / SKM 360 380246658 (3 m) 360 380 Resolver / SKS / SKM 360 380324781 (5 m) 308 326 Servo cable 15A 308 326324782 (7 m) 308 326 Servo cable 15A 308 326324783 (10 m) 308 326 Servo cable 15A 308 326324784 (15 m) 308 326 Servo cable 15A 308 326324785 (20m) 308 326 Servo cable 15A 308 326324786 (25 m) 308 326 Servo cable 15A 308 326324787 (30 m) 308 326 Servo cable 15A 308 326324788 (35 m) 308 326 Servo cable 15A 308 326324789 (40 m) 308 326 Servo cable 15A 308 326324790 (50 m) 308 326 Servo cable 15A 308 326324791 (75 m) 308 326 Servo cable 15A 308 326


Content<strong>Chainflex</strong> ® ReadyCable ®BAUMÜLLERBaumüller – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cableExtension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE324792 (100 m) 308 326 Servo cable 15A 308 326326577 (5 m) 309 327 Servo cable 21 A 310 328326578 (7 m) 309 327 Servo cable 21 A 310 328326579 (10 m) 309 327 Servo cable 21 A 310 328326580 (15 m) 309 327 Servo cable 21 A 310 328326581 (20 m) 309 327 Servo cable 21 A 310 328326582 (25 m) 309 327 Servo cable 21 A 310 328326583 (30 m) 309 327 Servo cable 21 A 310 328326584 (35 m) 309 327 Servo cable 21 A 310 328326585 (40 m) 309 327 Servo cable 21 A 310 328326586 (50 m) 309 327 Servo cable 21 A 310 328326587 (70 m) 309 327 Servo cable 21 A 310 328326588 (100 m) 310 328 Servo cable 21 A 310 328326589 (5 m) 310 328 Servo cable 28 A 310 328326591 (7 m) 310 328 Servo cable 28 A 310 328326592 (10 m) 310 328 Servo cable 28 A 310 328326593 (15 m) 310 328 Servo cable 28 A 310 328326594 (20 m) 310 328 Servo cable 28 A 310 328326596 (25 m) 310 328 Servo cable 28 A 310 328326597 (30 m) 310 328 Servo cable 28 A 310 328326598 (35 m) 310 328 Servo cable 28 A 310 328326599 (40 m) 310 328 Servo cable 28 A 310 328326600 (5 m) 310 328 Servo cable 36 A 311 329326601 (7 m) 310 328 Servo cable 36 A 311 329326602 (10 m) 310 328 Servo cable 36 A 311 329326603 (15 m) 310 328 Servo cable 36 A 311 329326604 (20 m) 310 328 Servo cable 36 A 311 329326605 (25 m) 310 328 Servo cable 36 A 311 329326606 (30 m) 310 328 Servo cable 36 A 311 329326607 (35 m) 310 328 Servo cable 36 A 311 329326608 (40 m) 311 329 Servo cable 36 A 311 329326609 (5 m) 311 329 Servo cable 50 A 311 329326610 (7 m) 311 329 Servo cable 50 A 311 329326611 (10 m) 311 329 Servo cable 50 A 311 329326612 (15 m) 311 329 Servo cable 50 A 311 329326613 (20 m) 311 329 Servo cable 50 A 311 329326614 (25 m) 311 329 Servo cable 50 A 311 329326615 (30 m) 311 329 Servo cable 50 A 311 329326616 (35 m) 311 329 Servo cable 50 A 311 329326617 (40 m) 311 329 Servo cable 50 A 311 329369864 (3 m) 361 381 ECN1313/EQN1325 362 382371494 (20 m) 361 381 ECN1313/EQN1325 362 382378022 (50 m) 361 381 ECN1313/EQN1325 362 382380358 (35 m) 361 381 ECN1313/EQN1325 362 382380967 (7 m) 309 327 Servo cable 20 A 309 327382005 (45 m) 361 381 ECN1313/EQN1325 362 382295


Content<strong>Chainflex</strong> ® ReadyCable ®BAUMÜLLERBERGER LAHR BECKHOFFBaumüller – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cableExtension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE389807 (7 m) 361 381 ECN1313/EQN1325 362 382389808 (9 m) 361 381 ECN1313/EQN1325 362 382391216 (40 m) 361 381 ECN1313/EQN1325 362 382393889 (2 m) 361 381 ECN1313/EQN1325 362 382393890 (8 m) 361 381 ECN1313/EQN1325 362 382393891 (10 m) 361 381 ECN1313/EQN1325 362 382393892 (15 m) 361 381 ECN1313/EQN1325 362 382393893 (25 m) 361 381 ECN1313/EQN1325 362 382393894 (30 m) 361 381 ECN1313/EQN1325 362 382394014 (5 m) 361 381 ECN1313/EQN1325 362 382413410 (10 m) 309 327 Servo cable 20 A 309 327414840 (5 m) 309 327 Servo cable 20 A 309 327414841 (15 m) 309 327 Servo cable 20 A 309 327414842 (20 m) 309 327 Servo cable 20 A 309 327414843 (25 m) 309 327 Servo cable 20 A 309 327414846 (30 m) 309 327 Servo cable 20 A 309 327414848 (35 m) 309 327 Servo cable 20 A 309 327414849 (40 m) 309 327 Servo cable 20 A 309 327414850 (50 m) 309 327 Servo cable 20 A 309 327414851 (75 m) 309 327 Servo cable 20 A 309 327414852 (100 m) 309 327 Servo cable 20 A 309 327Beckhoff – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cableZK1090-9191-xxxx 396ZK4000-2111-xxxx 311 329ZK4000-2112-xxxx 311 329ZK4000-2210-xxxx 356 372ZK4000-2610-xxxx 356 372Extension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPEZK4500-0023-xxxx 312 330 ZK4501-0023-xxxx 312 330ZK4500-0024-xxxx 312 330 ZK4501-0024-xxxx 312 330ZK4510-0020-xxxx 356 372 ZK4511-0020-xxxx 356 372ZK4520-0020-xxxx 356 372 ZK4511-0020-xxxx 356 372ZK4530-0010-xxxx 356 372 ZK4531-0020-xxxx 357 372Berger Lahr – Selection table according to part numbers and sheath materials.Basic cableVW3M5101Rxxx 312 330VW3M5102Rxxx 312 330VW3M8101Rxxx 362 382Extension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE296


Content<strong>Chainflex</strong> ® ReadyCable ®CONTROL TECHNIQUESControl Techniques – Selection table according to part numbers and sheath materials.Basic cableExtension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPEPB B A A A XXX 312 330PB B A A B XXX 313 331PB B A B B XXX 313 331PB B A F A XXX 312 330PB B A F B XXX 313 331PB B A G B XXX 313 331PB B B A A XXX 312 330PB B B A B XXX 313 331PB B B F A XXX 312 330PB B B G B XXX 313 331PB B C A B XXX 313 331PB B C B B XXX 313 331PB B C F B XXX 313 331PB B C G B XXX 313 331PB B D A B XXX 313 331PB B D B B XXX 313 331PB B D F B XXX 313 331PB B D G B XXX 313 331PB B E A B XXX 313 331PB B E B B XXX 313 331PB B G A A XXX 312 330PB B G A B XXX 313 331PB B G B B XXX 313 331PB B G F A XXX 312 330PB B G F B XXX 313 331PB B G G B XXX 313 331PS B A A A XXX 344 350PS B A A B XXX 344 350PS B A B B XXX 344 350PS B A F A XXX 344 350PS B A F B XXX 344 350PS B B A A XXX 344 350PS B B A B XXX 344 350PS B B B B XXX 344 350PS B B F A XXX 344 350PS B C A B XXX 344 350PS B C B B XXX 344 350PS B C F B XXX 344 350PS B D A B XXX 344 350PS B D B B XXX 344 350PS B D F B XXX 344 350PS B E A B XXX 344 350PS B E B B XXX 344 350PS B G A A XXX 344 350PS B G A B XXX 344 350PS B G B B XXX 344 350PS B G F A XXX 344 350297


Content<strong>Chainflex</strong> ® ReadyCable ®298CONTROL TECHN.DANAHER MOTIONControl Techniques – Selection table according to part numbers and sheath materials.Basic cablePS B G F B XXX 344 350SS B A H C XXX 362 382SS B A H H XXX 362 382SS B A H N XXX 362 382PB A A F B XXX 313PB B B B B XXX 313 331PB B B F B XXX 331PB B E F B XXX 313 331PB B E G B XXX 313 331PS B B F B XXX 344 350Extension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPEPS B E F B XXX 344 350Danaher Motion – Selection table according to part numbers and sheath materials.Connection cable102575 (5 m) 345 351102576 (10 m) 345 351102579 (5 m) 314 332102580 (10 m) 314 332102806 (15 m) 345 351102807 (20 m) 345 351102808 (25 m) 345 351102809 (15 m) 314 332102810 (20 m) 314 332102811 (25 m) 314 332107473 (5 m) 345 351107474 (10 m) 345 351107475 (15 m) 345 351107476 (20 m) 345 351107477 (25 m) 345 351107479 (5 m) 314 332107480 (10 m) 314 332107481 (15 m) 314 332107482 (20 m) 314 332107483 (25 m) 314 332107485 (5 m) 345 351107486 (10 m) 345 351107487 (15 m) 345 351107488 (20 m) 345 351107489 (25 m) 345 351107491 (5 m) 313 331107492 (10 m) 313 331107493 (15 m) 313 331107494 (20 m) 313 331107495 (25 m) 314 332107915 (5 m) 357 378107916 (10 m) 357 378Extension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE


Content<strong>Chainflex</strong> ® ReadyCable ®DANAHER MOTIONDanaher Motion – Selection table according to part numbers and sheath materials.Connection cableExtension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE107917 (15 m) 357 378107918 (20 m) 357 378107919 (25 m) 357 378200456 (5 m) 346 352200457 (10 m) 346 352200458 (15 m) 346 352200459 (20 m) 346 352200460 (25 m) 346 352200462 (5 m) 314 332200463 (10 m) 314 332200464 (15 m) 314 332200465 (20 m) 314 332200466 (25 m) 314 332200468 (5 m) 346 352200469 (10 m) 346 352200470 (15 m) 346 352200471 (20 m) 346 352200472 (25 m) 346 352200474 (5 m) 314 332200475 (10 m) 315 333200476 (15 m) 315 333200477 (20 m) 315 333200478 (25 m) 315 333200618 (5 m) 346 352200619 (10 m) 346 352200620 (15 m) 346 352200621 (20 m) 346 352200622 (25 m) 346 352200623 (5 m) 315 333200624 (10 m) 315 333200625 (15 m) 315 333200626 (20 m) 315 333200627 (25 m) 315 33384972 (5 m) 357 37884973 (10 m) 357 37884974 (15 m) 357 37884975 (20 m) 357 37885034 (5 m) 357 37885035 (10 m) 357 37885036 (15 m) 357 37885037 (20 m) 357 37885039 (5 m) 358 37985040 (10 m) 358 37985041 (15 m) 358 37985042 (20 m) 358 37987655 (25 m) 357 37889918 (5 m) 345 351299


Content<strong>Chainflex</strong> ® ReadyCable ®DANAHER MOTIONELAUDanaher Motion – Selection table according to part numbers and sheath materials.Connection cable89952 (10 m) 345 35189953 (15 m) 345 35189954 (20 m) 345 35189956 (25 m) 345 35189957 (5 m) 314 33289959 (5 m) 345 35189960 (10 m) 345 35189961 (10 m) 314 33289962 (15 m) 345 35189963 (15 m) 314 33289964 (20 m) 346 35289965 (20 m) 314 33289966 (25 m) 346 35289967 (25 m) 314 33289968 (5 m) 314 33289969 (25 m) 314 33289970 (10 m) 314 33289971 (15 m) 314 33289972 (20 m) 314 33290083 (5 m) 345 35190084 (10 m) 345 35190085 (15 m) 345 35190086 (20 m) 345 35190087 (25 m) 345 35190088 (5 m) 314 33290089 (10 m) 314 33290090 (15 m) 314 33290091 (20 m) 314 33290092 (25 m) 314 33290287 (5 m) 357 37891019 (10 m) 357 37891807 (20 m) 357 37891811 (15 m) 357 378Extension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE92205 (25 m) 357 378Elau – Selection table according to part numbers and sheath materials.Connection cableE-MO-067 315 333E-MO-111 SH-Motor 1,5 315 333E-MO-087 315 333E-MO-092 315 333E-MO-113 SH-Motor 2.5 315 333E-FB-060 362 382E-FB-071 362 382E-FB-080 362 382Extension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE300


Content<strong>Chainflex</strong> ® ReadyCable ®FAGORHEIDENHAIN FANUCFagor – Selection table according to part numbers and sheath materials.Basic cableiXC-C2-D 382iXC-C2-FN2 383iXC-C2-H 383iXC-C4-D 383iXC-C8-F-C9 383iXC-C8-F-D 383Extension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPEiXC-C8-FN 383FANUC – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cable – Premium LineBasic cable – Economy LineOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPELX660-4077-T296 374 LX660-4077-T296 383LX660-4077-T297 374 LX660-4077-T297 384LX660-4077-T302 374 LX660-4077-T302 384LX660-4077-T303 374 LX660-4077-T303 384LX660-4077-T319 374 LX660-4077-T319 384LX660-8077-T261 324 LX660-8077-T261 333LX660-8077-T264 324 LX660-8077-T264 334LX660-8077-T265 324 LX660-8077-T265 334LX660-8077-T266 324 LX660-8077-T266 334LX660-8077-T267 324 LX660-8077-T267 334LX660-8077-T270 324 LX660-8077-T270 334LX660-8077-T271 324 LX660-8077-T271 334LX660-8077-T272 324 LX660-8077-T272 334LX660-8077-T273 324 LX660-8077-T273 334LX660-8077-T291 324 LX660-8077-T291 334LX660-8077-T292 325 LX660-8077-T292 334LX660-8077-T293 324 LX660-8077-T293 334LX660-8077-T296 325 LX660-8077-T296 335LX660-8077-T298 325 LX660-8077-T298 335LX660-8077-T300 325 LX660-8077-T300 335Heidenhain – Selection table according to part numbers and sheath materials.Connection cable298 399-xx 375 385298 400-xx 375 385298 402-xx 376 386309 738-xx 375 385309 774-xx 375 385309 777-xx 376 385309 778-xx 376 385310 193-xx 376 386310 197-xx 375 384310 199-xx 375 385323 897-xx 375 385Extension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE301


Content<strong>Chainflex</strong> ® ReadyCable ®302LENZE HEIDENHAINHeidenhain – Selection table according to part numbers and sheath materials.Connection cable324 544-xx 375 385332 115-xx 374 384335 077-xx 376 386354 411-xx 375 385355 398-xx 375 385Extension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE360 472-xx 374 384Lenze – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cableLinking cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPEEWLExxxGM-T 363 386 EWLExxxZMST 363 387EWLLxxxGMS 400 402 EWLLxxxZM 400 402EWLMxxxGMS-015C 315 335 EWLMxxxZM-015C 316 336EWLMxxxGMS-025 315 335 EWLMxxxZM-025 316 336EWLRxxxGM-T 362 386 EWLRxxxZMST 363 386EYF0018AxxxxA00S03 364 388EYF0018AxxxxA00W02 364 387EYF0018AxxxxF02S03 364 387 EYF0019VxxxxF02G02 364 388EYF0018AxxxxF02W02 364 387 EYF0019VxxxxF02G02 364 388EYF0019VxxxxA00G02 363 387 EYF0019VxxxxF02G02 364 388EYF0020AxxxxA00S04 364 387EYF0020AxxxxA00S05 364 388EYF0020AxxxxF01S04 364 387 EYF0020VxxxxF01G01 364 388EYF0020AxxxxF01S05 364 387 EYF0020VxxxxF01G01 364 388EYF0020VxxxxA00G01 363 387 EYF0020VxxxxF01G01 364 388EYF0021AxxxxA00S03 364 388EYF0021AxxxxF03S03 364 387 EYF0022VxxxxF03G03 364 388EYF0022VxxxxA00G03 363 387 EYF0022VxxxxF03G03 364 388EYL002AxxxxL01A00 400 402 EYL002VxxxxL01J01 400 402EYL002AxxxxL02A00 400 402 EYL002VxxxxL02J02 400 402EYL002VxxxxA00J01 400 402 EYL002VxxxxL01J01 400 402EYL002VxxxxA00J02 400 402 EYL002VxxxxL02J02 400 402EYP0010AxxxxA00P01 316 335 EYP0010VxxxxM01P01 316 336EYP0010AxxxxM01A00 316 335 EYP0010VxxxxM01P01 316 336EYP0011AxxxxA00P01 316 335 EYP0011VxxxxM01P01 316 336EYP0011AxxxxM01A00 316 335 EYP0011VxxxxM01P01 316 336EYP0012AxxxxA00P01 316 336 EYP0012VxxxxM01P01 316 336EYP0012AxxxxA00P02 316 335 EYP0012VxxxxM02P02 316 336EYP0012AxxxxM01A00 316 335 EYP0012VxxxxM01P01 316 336EYP0012AxxxxM02A00 316 335 EYP0012VxxxxM02P02 316 336EYP0013AxxxxA00P02 316 335 EYP0013VxxxxM02P02 316 336EYP0013AxxxxM02A00 316 335 EYP0013VxxxxM02P02 316 336EYP0014AxxxxA00P03 316 335 EYP0014VxxxxM03P03 316 336EYP0014AxxxxM03A00 316 335 EYP0014VxxxxM03P03 316 336EYP0015AxxxxA00P03 316 335 EYP0015VxxxxM03P03 316 336EYP0015AxxxxM03A00 316 335 EYP0015VxxxxM03P03 316 336


Content<strong>Chainflex</strong> ® ReadyCable ®LENZENUMREXROTHLenze – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cableLinking cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPEEYP0016AxxxxA00P03 316 335 EYP0016VxxxxM03P03 316 336EYP0016AxxxxM03A00 316 335 EYP0016VxxxxM03P03 316 336Terminal box connection cableEWLExxxGX-T 363 387EWLRxxxGX-T 362 386Connecting cableEYD0017AxxxxW01S01 365 388EYD0017AxxxxW01S02 365 388EYD0017AxxxxW03S01 365 388EYD0017AxxxxW03S02 365 388NUM – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cableExtension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPEAGOFRU012Mxxx 398 402 AGOFRU012Mxxx 398 402AGOFRU018LMxxx 346 352 AGOFRU018LMxxx 346 352AGOFRU018Mxxx 316 336 AGOFRU018Mxxx 317 336AGOFRU019LMxxx 346 352 AGOFRU019LMxxx 346 352AGOFRU019Mxxx 316 336 AGOFRU019Mxxx 317 336AGOFRU020Mxxx 317 336 AGOFRU020Mxxx 317 337AGOFRU029Mxxx 365 389 AGOFRU029Mxxx 365 389AGOFRU030Mxxx 365 389 AGOFRU030Mxxx 366 389Rexroth – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cableIKG0001 317 337IKG0006 317 337IKG0011 317 337Connecting cable with adapter plugsOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPEIKG0021 317 337 IKG0023 318 338IKG0041 317 337IKG0042 317 337IKG0061 317 337IKG0081 317 337 IKG0089 318 338IKG0101 317 337IKG0121 317 337IKG0161 317 337 IKG0168 318 338IKG0331 317 337 IKG0332 318 338IKG4008 317 337 IKG4006 318 338IKG4009 317 337 IKG4006 318 338IKG4017 317 337 IKG4006 318 338IKG4018 317 337IKG4020 318 337IKG4055 318 337303


Content<strong>Chainflex</strong> ® ReadyCable ®REXROTHRexroth – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cableConnecting cable with adapter plugsOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPEIKG4060 318 337IKG4067 318 337 IKG4061 318 338IKG4070 318 337 IKG4061 318 338IKG4072 318 337 IKG4074 318 338IKG4087 318 337 IKG4081 318 338IKG4090 318 337 IKG4081 318 338IKG4100 318 337IKG4103 318 337IKG4107 318 337IKG4118 318 338IKG4119 318 338IKG4147 318 338 IKG4141 319 338IKG4150 318 338 IKG4141 319 338IKG4155 318 338 IKG4141 319 338IKG4164 318 338IKG4167 318 338 IKG4161 319 338IKG4172 318 338IKG4173 318 338IKG4186 318 338IKG4200 318 338IKG4204 318 338IKS0230 366 389 IKS0232 366 390IKS0251 389 IKS0255 390IKS0253 389 IKS0255 390IKS0259 389IKS0262 389IKS0301 366 389 IKS0303 367 390IKS0315 366 389IKS0374 366 389IKS4001 366 389IKS4002 366 389IKS4020 366 389 IKS4376 367 390IKS4038 366 389IKS4041 366 390IKS4042 366 390 IKS4151 / IKS 4153 367 390IKS4066 366 390IKS4103 366 390 IKS4322 367 390IKS4142 366 390 IKS4376 367 390IKS4314 366 390IKS4374 366 390IKS4375 366 390IKS4384 366 390IKS4389 366 390RKG0014 366 390RKG0020 366 390RKG0026 366 390304


Content<strong>Chainflex</strong> ® ReadyCable ®REXROTHSEWRexroth – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cableRKG0028 366 390Connecting cable with adapter plugsOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPERKG4200 367 390 RKG4201 367 390RKL4300 319 338 RKL4304 320 339RKL4301 319 338 RKL4304 320 339RKL4302 319 338 RKL4305 320 339RKL4303 319 338 RKL4305 320 339RKL4306 319 338 RKL4311 320 339RKL4307 319 338 RKL4311 320 339RKL4308 319 339 RKL4312 320 339RKL4309 319 339 RKL4312 320 339RKL4310 319 339 RKL4312 320 339RKL4313 319 339 RKL4316 320 339RKL4314 319 339 RKL4316 320 339RKL4315 319 339 RKL4316 320 339RKL4317 319 339 RKL4319 320 339RKL4318 319 339 RKL4319 320 339RKL4320 319 339RKL4321 319 339 RKL4336 320 339RKL4322 319 339RKL4323 319 339 RKL4338 320 339RKL4324 319 339RKL4325 319 339RKL4326 319 339 RKL4338 320 339RKL4327 319 339RKL4328 319 339 RKL4336 320 339RKL4329 319 339RKL4330 319 339 RKL4340 320 339RKL4331 319 339SEW – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Connection cableExtension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE0590 477 3 347 353 0590 361 0 347 3531332 455 1 367 391 199 540 5 367 3911332 486 1 320 340 0593 650 0 321 3401332 743 7 367 391 199 541 3 367 391198 930 8 367 391199 180 9 346 352 199 550 2 347 353199 182 5 346 352 199 552 9 347 353199 184 1 346 352 199 554 5 347 353199 186 8 347 353 199 556 1 391 353199 188 4 347 353 199 558 8 347 353199 190 6 320 340 199 200 7 320 340199 192 2 320 340 199 202 3 320 340199 194 9 320 340 199 204 X 320 340305


Content<strong>Chainflex</strong> ® ReadyCable ®306SEWSIEMENSSEW – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Connection cableExtension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE199 196 5 320 340 199 206 6 320 340199 198 1 320 340 199 208 2 320 340199 319 4 367 391 199 541 3 367 391Siemens – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cable6FX8002-1DC00 376Extension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE6FX8002-2AD00 368 391 6FX8002-2AD04 369 3936FX8002-2AH00 369 393 6FX8002-2AH04 369 3936FX8002-2CA11 368 391 6FX8002-2CB54 369 3936FX8002-2CA15 368 391 6FX8002-2CA54 369 3936FX8002-2CA31 368 391 6FX8002-2CA34 369 3936FX8002-2CA51 368 391 6FX8002-2CA54 369 3936FX8002-2CA71 368 3916FX8002-2CB31 392 6FX8002-2CB34 3936FX8002-2CB51 368 392 6FX8002-2CC14 369 3936FX8002-2CC11 368 392 6FX8002-2CB54 369 3936FX8002-2CD01 368 392 6FX8002-2CB54 369 3936FX8002-2CF01 368 3926FX8002-2CF02 368 392 6FX8002-2CF04 369 3936FX8002-2CG00 368 392 6FX8002-2CB54 369 3936FX8002-2CH00 368 392 6FX8002-2AD04 369 3936FX8002-2CK00 368 3926FX8002-2CL00 368 3926FX8002-2DC10 3766FX8002-2DC20 3766FX8002-2EQ00 369 3926FX8002-2EQ10 369 392 6FX8002-2EQ14 369 3936FX8002-5CA01 347 353 6FX8002-5CA05 348 3546FX8002-5CA11 347 353 6FX8002-5CA15 348 3546FX8002-5CA21 347 353 6FX8002-5CA28 348 3546FX8002-5CA23 348 354 6FX8002-5CX28 348 3546FX8002-5CA31 347 353 6FX8002-5CA38 348 3546FX8002-5CA41 347 353 6FX8002-5CA48 348 3546FX8002-5CA51 347 353 6FX8002-5CA58 348 3546FX8002-5CA61 347 353 6FX8002-5CA68 348 3546FX8002-5CS01 348 3546FX8002-5CS21 348 3546FX8002-5CS31 348 3546FX8002-5DA01 321 340 6FX8002-5DA05 322 3416FX8002-5DA11 321 340 6FX8002-5DA15 322 3416FX8002-5DA21 321 341 6FX8002-5DA28 322 3416FX8002-5DA23 321 341 6FX8002-5DX28 322 3426FX8002-5DA31 321 341 6FX8002-5DA38 322 341


Content<strong>Chainflex</strong> ® ReadyCable ®SIEMENSSTÖBERSiemens – Selection table according to part numbers and sheath materials.You will find your basic cable in the left column, the respective extension on the right.Basic cableExtension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE6FX8002-5DA33 321 341 6FX8002-5DX38 322 3426FX8002-5DA41 321 341 6FX8002-5DA48 322 3416FX8002-5DA43 321 341 6FX8002-5DX48 322 3426FX8002-5DA51 321 341 6FX8002-5DA58 322 3426FX8002-5DA61 321 341 6FX8002-5DA68 322 3426FX8002-5DS01 321 3416FX8002-5DS21 321 3416FX8002-5DS61 321 341Stöber – Selection table according to part numbers and sheath materials.Basic cableGr.1-Motor-1,0mm² 322 342Gr.1-Motor-1,5mm² 322 342Gr.1-Motor-2,5mm² 322 342Gr.1-Motor-4,0mm² 322 342Gr.1,5-Motor-4,0mm² 322 342Gr.1,5-Motor-6,0mm² 322 342Gr.1,5-Motor-10,0mm² 323 342Encoder ED/EK iSDS4000 370 394Encoder ES iSDS4000 394Encoder iMDS5000 370 393Resolver iMDS5000 369 393Resolver iSDS4000 370 394Extension cableOuter jacket material page Outer jacket material pagePVC PUR TPE PVC PUR TPE307


ServoPVC<strong>Chainflex</strong> ® -PVC-Servo cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Moss green (similar to RAL 6005)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmB&RBasic cableB&Ri8CMxxx.12-1 MAT9610001 (4 G 1,5+2x(2x0,75)C)C 14,5i8CMxxx.12-3 MAT9610002 (4 G 4,0+2x(2x1,5)C)C 18,5B&RBasic cablei8CMxxx.12-5 MAT9610003 (4 G 10,0+2x(2x1,5)C)C 24,0Baumüller15 A-Basic cable*BAUMÜLLER324781 (5 m) MAT9295001 (4 G 1,5+2x(2x0,75)C)C 14,5324782 (7 m) MAT9295002 (4 G 1,5+2x(2x0,75)C)C 14,5324783 (10 m) MAT9295003 (4 G 1,5+2x(2x0,75)C)C 14,5324784 (15 m) MAT9295004 (4 G 1,5+2x(2x0,75)C)C 14,5324785 (20 m) MAT9295005 (4 G 1,5+2x(2x0,75)C)C 14,5324786 (25 m) MAT9295006 (4 G 1,5+2x(2x0,75)C)C 14,5324787 (30 m) MAT9295007 (4 G 1,5+2x(2x0,75)C)C 14,5324788 (35 m) MAT9295008 (4 G 1,5+2x(2x0,75)C)C 14,5324789 (40 m) MAT9295009 (4 G 1,5+2x(2x0,75)C)C 14,5324790 (50 m) MAT9295010 (4 G 1,5+2x(2x0,75)C)C 14,5324791 (75 m) MAT9295011 (4 G 1,5+2x(2x0,75)C)C 14,5324792 (100 m) MAT9295012 (4 G 1,5+2x(2x0,75)C)C 14,5Baumüller15 A-Extension cableMAT9297001 (4 G 1,5+2x(2x0,75)C)C 14,5All <strong>cables</strong> available in the lengths you require.308Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameterManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmBaumüller20 A-Basic cable*BAUMÜLLER414840 (5 m) MAT9295020 (4 G 2,5+2x(2x1,5)C)C 17,5380967 (7 m) MAT9295021 (4 G 2,5+2x(2x1,5)C)C 17,5413410 (10 m) MAT9295022 (4 G 2,5+2x(2x1,5)C)C 17,5414841 (15 m) MAT9295023 (4 G 2,5+2x(2x1,5)C)C 17,5414842 (20 m) MAT9295024 (4 G 2,5+2x(2x1,5)C)C 17,5414843 (25 m) MAT9295025 (4 G 2,5+2x(2x1,5)C)C 17,5414846 (30 m) MAT9295026 (4 G 2,5+2x(2x1,5)C)C 17,5414848 (35 m) MAT9295027 (4 G 2,5+2x(2x1,5)C)C 17,5414849 (40 m) MAT9295028 (4 G 2,5+2x(2x1,5)C)C 17,5414850 (50 m) MAT9295029 (4 G 2,5+2x(2x1,5)C)C 17,5414851 (75 m) MAT9295030 (4 G 2,5+2x(2x1,5)C)C 17,5414852 (100 m) MAT9295031 (4 G 2,5+2x(2x1,5)C)C 17,5Baumüller20 A-Extension cableMAT9297020 (4 G 2,5+2x(2x1,5)C)C 17,5Baumüller21 A-Basic cable*326577 (5 m) MAT9295040 (4 G 2,5+2x(2x1,5)C)C 17,5326578 (7 m) MAT9295041 (4 G 2,5+2x(2x1,5)C)C 17,5326579 (10 m) MAT9295042 (4 G 2,5+2x(2x1,5)C)C 17,5326580 (15 m) MAT9295043 (4 G 2,5+2x(2x1,5)C)C 17,5326581 (20m) MAT9295044 (4 G 2,5+2x(2x1,5)C)C 17,5326582 (25 m) MAT9295045 (4 G 2,5+2x(2x1,5)C)C 17,5326583 (30 m) MAT9295046 (4 G 2,5+2x(2x1,5)C)C 17,5326584 (35 m) MAT9295047 (4 G 2,5+2x(2x1,5)C)C 17,5326585 (40 m) MAT9295048 (4 G 2,5+2x(2x1,5)C)C 17,5326586 (50 m) MAT9295049 (4 G 2,5+2x(2x1,5)C)C 17,5326587 (70m) MAT9295050 (4 G 2,5+2x(2x1,5)C)C 17,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu309


ServoPVC<strong>Chainflex</strong> ® -PVC-Servo cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Moss green (similar to RAL 6005)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømm326588 (100 m) MAT9295051 (4 G 2,5+2x(2x1,5)C)C 17,5Baumüller21 A-Extension cableMAT9297040 (4 G 2,5+2x(2x1,5)C)C 17,5Baumüller28 A-Basic cable*BAUMÜLLER326589 (5 m) MAT9295060 (4 G 4+2x(2x1,5)C)C 18,5326591 (7 m) MAT9295061 (4 G 4+2x(2x1,5)C)C 18,5326592 (10 m) MAT9295062 (4 G 4+2x(2x1,5)C)C 18,5326593 (15 m) MAT9295063 (4 G 4+2x(2x1,5)C)C 18,5326594 (20m) MAT9295064 (4 G 4+2x(2x1,5)C)C 18,5326596 (25 m) MAT9295065 (4 G 4+2x(2x1,5)C)C 18,5326597 (30 m) MAT9295066 (4 G 4+2x(2x1,5)C)C 18,5326598 (35 m) MAT9295067 (4 G 4+2x(2x1,5)C)C 18,5326599 (40 m) MAT9295068 (4 G 4+2x(2x1,5)C)C 18,5Baumüller28 A-Extension cableMAT9297060 (4 G 4+2x(2x1,5)C)C 18,5Baumüller36 A-Basic cable*326600 (5 m) MAT9295070 (4 G 6+2x(2x1,5)C)C 20,5326601 (7 m) MAT9295071 (4 G 6+2x(2x1,5)C)C 20,5326602 (10 m) MAT9295072 (4 G 6+2x(2x1,5)C)C 20,5326603 (15 m) MAT9295073 (4 G 6+2x(2x1,5)C)C 20,5326604 (20m) MAT9295074 (4 G 6+2x(2x1,5)C)C 20,5326605 (25 m) MAT9295075 (4 G 6+2x(2x1,5)C)C 20,5326606 (30 m) MAT9295076 (4 G 6+2x(2x1,5)C)C 20,5326607 (35 m) MAT9295077 (4 G 6+2x(2x1,5)C)C 20,5All <strong>cables</strong> available in the lengths you require.310Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameterManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømm326608 (40 m) MAT9295078 (4 G 6+2x(2x1,5)C)C 20,5Baumüller36 A-Extension cableMAT9297070 (4 G 6+2x(2x1,5)C)C 20,5BAUMÜLLERBaumüller50 A-Basic cable*326609 (5 m) MAT9295080 (4 G 10+2x(2x1,5)C)C 24,0326610 (7 m) MAT9295081 (4 G 10+2x(2x1,5)C)C 24,0326611 (10 m) MAT9295082 (4 G 10+2x(2x1,5)C)C 24,0326612 (15 m) MAT9295083 (4 G 10+2x(2x1,5)C)C 24,0326613 (20m) MAT9295084 (4 G 10+2x(2x1,5)C)C 24,0326614 (25 m) MAT9295085 (4 G 10+2x(2x1,5)C)C 24,0326615 (30 m) MAT9295086 (4 G 10+2x(2x1,5)C)C 24,0326616 (35 m) MAT9295087 (4 G 10+2x(2x1,5)C)C 24,0326617 (40 m) MAT9295088 (4 G 10+2x(2x1,5)C)C 24,0Baumüller50 A-Extension cableMAT9297080 (4 G 10+2x(2x1,5)C)C 24,0BeckhoffBasic cableBECKHOFFZK4000-2111-xxxx MAT9371005 (4 G 1,5+(2x1)C)C 12,5BeckhoffBasic cableZK4000-2112-xxxx MAT9371006 (4 G 2,5+(2x1)C)C 13,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu311


ServoPVC<strong>Chainflex</strong> ® -PVC-Servo cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Moss green (similar to RAL 6005)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmBeckhoffBasic cableZK4500-0023-xxxx MAT9371001 (4 G 1,5+2x(2x0,75)C)C 14,5BECKHOFFBeckhoffBasic cableZK4500-0024-xxxx MAT9371002 (4 G 2,5+2x(2x1,5)C)C 17,5BeckhoffExtension cableZK4501-0023-xxxx MAT9371003 (4 G 1,5+2x(2x0,75)C)C 14,5BeckhoffExtension cableZK4501-0024-xxxx MAT9371004 (4 G 2,5+2x(2x1,5)C)C 17,5CONTROL TECHNIQUES BERGER LAHRBerger LahrBasic cableVW3M5101Rxxx MAT94502001 (4 G 1,5+(2x1)C)C 12,5VW3M5102Rxxx MAT94502003 (4 G 2,5+(2x1)C)C 13,5Control TechniquesBasic cablePB B G A A XXX MAT9560040 (4 G 1,5+(2x1)C)C 12,5PB B A A A XXX MAT9560041 (4 G 2,5+(2x1)C)C 13,5PB B B A A XXX MAT9560042 (4 G 4,0+(2x1)C)C 16,0PB B G F A XXX MAT9560043 (4 G 1,5+(2x1)C)C 12,5PB B A F A XXX MAT9560044 (4 G 2,5+(2x1)C)C 13,5PB B B F A XXX MAT9560045 (4 G 4,0+(2x1)C)C 16,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core312950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameterManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmControl TechniquesBasic cableCONTROL TECHNIQUESPB B G A B XXX MAT9560046 (4 G 1,5+(2x1)C)C 12,5PB B A A B XXX MAT9560047 (4 G 2,5+(2x1)C)C 13,5PB B B A B XXX MAT9560048 (4 G 4,0+(2x1)C)C 16,0PB B C A B XXX MAT9560049 (4 G 6,0+(2x1)C)C 17,5PB B D A B XXX MAT9560050 (4 G 10,0+(2x1)C)C 20,5PB B E A B XXX MAT9560051 (4 G 16,0+(2x1)C)C 23,0PB B G F B XXX MAT9560052 (4 G 1,5+(2x1)C)C 12,5PB A A F B XXX MAT9560053 (4 G 2,5+(2x1)C)C 13,5PB B A F B XXX MAT9560054 (4 G 4,0+(2x1)C)C 16,0PB B C F B XXX MAT9560055 (4 G 6,0+(2x1)C)C 17,5PB B D F B XXX MAT9560056 (4 G 10,0+(2x1)C)C 20,5PB B E F B XXX MAT9560057 (4 G 16,0+(2x1)C)C 23,0PB B G B B XXX MAT9560058 (4 G 1,5+(2x1)C)C 12,5PB B A B B XXX MAT9560059 (4 G 2,5+(2x1)C)C 13,5PB B B B B XXX MAT9560060 (4 G 4,0+(2x1)C)C 16,0PB B C B B XXX MAT9560061 (4 G 6,0+(2x1)C)C 17,5PB B D B B XXX MAT9560062 (4 G 10,0+(2x1)C)C 20,5PB B E B B XXX MAT9560063 (4 G 16,0+(2x1)C)C 23,0PB B G G B XXX MAT9560064 (4 G 1,5+(2x1)C)C 12,5PB B A G B XXX MAT9560065 (4 G 2,5+(2x1)C)C 13,5PB B B G B XXX MAT9560066 (4 G 4,0+(2x1)C)C 16,0PB B C G B XXX MAT9560067 (4 G 6,0+(2x1)C)C 17,5PB B D G B XXX MAT9560068 (4 G 10,0+(2x1)C)C 20,5PB B E G B XXX MAT9560069 (4 G 16,0+(2x1)C)C 23,0DANAHER MOTIONDanaher MotionBasic cable107491 (5 m) MAT9340001 (4 G 1,5+(2x1)C)C 12,5107492 (10 m) MAT9340005 (4 G 1,5+(2x1)C)C 12,5107493 (15 m) MAT9340006 (4 G 1,5+(2x1)C)C 12,5107494 (20 m) MAT9340007 (4 G 1,5+(2x1)C)C 12,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu313


ServoPVC<strong>Chainflex</strong> ® -PVC-Servo cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Moss green (similar to RAL 6005)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmDANAHER MOTION107495 (25 m) MAT9340008 (4 G 1,5+(2x1)C)C 12,5107479 (5 m) MAT9340009 (4 G 1,5+(2x1)C)C 12,5107480 (10 m) MAT9340010 (4 G 1,5+(2x1)C)C 12,5107481 (15 m) MAT9340011 (4 G 1,5+(2x1)C)C 12,5107482 (20 m) MAT9340012 (4 G 1,5+(2x1)C)C 12,5107483 (25 m) MAT9340013 (4 G 1,5+(2x1)C)C 12,5102579 (5 m) MAT9340014 (4 G 1,5+(2x1)C)C 12,5102580 (10 m) MAT9340015 (4 G 1,5+(2x1)C)C 12,5102809 (15 m) MAT9340016 (4 G 1,5+(2x1)C)C 12,5102810 (20 m) MAT9340017 (4 G 1,5+(2x1)C)C 12,5102811 (25 m) MAT9340018 (4 G 1,5+(2x1)C)C 12,590088 (5 m) MAT9340019 (4 G 1,5+(2x1)C)C 12,590089 (10 m) MAT9340020 (4 G 1,5+(2x1)C)C 12,590090 (15 m) MAT9340021 (4 G 1,5+(2x1)C)C 12,590091 (20 m) MAT9340022 (4 G 1,5+(2x1)C)C 12,590092 (25 m) MAT9340023 (4 G 1,5+(2x1)C)C 12,589957 (5 m) MAT9340024 (4 G 1,5+(2x1)C)C 12,589961 (10 m) MAT9340025 (4 G 1,5+(2x1)C)C 12,589963 (15 m) MAT9340026 (4 G 1,5+(2x1)C)C 12,589965 (20 m) MAT9340027 (4 G 1,5+(2x1)C)C 12,589967 (25 m) MAT9340028 (4 G 1,5+(2x1)C)C 12,5Danaher MotionBasic cable89968 (5 m) MAT9340029 (4 G 2,5+(2x1)C)C 13,589970 (10 m) MAT9340030 (4 G 2,5+(2x1)C)C 13,589971 (15 m) MAT9340031 (4 G 2,5+(2x1)C)C 13,589972 (20 m) MAT9340032 (4 G 2,5+(2x1)C)C 13,589969 (25 m) MAT9340033 (4 G 2,5+(2x1)C)C 13,5200462 (5 m) MAT9340034 (4 G 1,5+(2x1)C)C 12,5200463 (10 m) MAT9340035 (4 G 1,5+(2x1)C)C 12,5200464 (15 m) MAT9340036 (4 G 1,5+(2x1)C)C 12,5200465 (20 m) MAT9340037 (4 G 1,5+(2x1)C)C 12,5200466 (25 m) MAT9340038 (4 G 1,5+(2x1)C)C 12,5200474 (5 m) MAT9340039 (4 G 2,5+(2x1)C)C 13,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core314950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameterManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmDANAHER MOTION200475 (10 m) MAT9340040 (4 G 2,5+(2x1)C)C 13,5200476 (15 m) MAT9340041 (4 G 2,5+(2x1)C)C 13,5200477 (20 m) MAT9340042 (4 G 2,5+(2x1)C)C 13,5200478 (25 m) MAT9340043 (4 G 2,5+(2x1)C)C 13,5200623 (5 m) MAT9340044 (4 G 4,0+(2x1)C)C 15,5200624 (10 m) MAT9340045 (4 G 4,0+(2x1)C)C 15,5200625 (15 m) MAT9340046 (4 G 4,0+(2x1)C)C 15,5200626 (20 m) MAT9340047 (4 G 4,0+(2x1)C)C 15,5200627 (25 m) MAT9340048 (4 G 4,0+(2x1)C)C 15,5ELAUBasic cableE-MO-067 MAT9470001 (4 G 1,5+2x(2x0,75)C)C 14,5E-MO-092 MAT9470004 (4 G 1,5+2x(2x0,75)C)C 14,5ELAUBasic cableLENZE ELAUE-MO-111 SH-Motor 1,5 MAT9470002 (4 G 1,5+2x(2x0,75)C)C 14,5ELAUBasic cableE-MO-087 MAT9470003 (4 G 2,5+2x(2x1,5)C)C 17,0ELAUBasic cableE-MO-113 SH-Motor 2.5 MAT9470005 (4 G 2,5+2x(2x1,5)C)C 17,0LenzeBasic cable*EWLMxxxGMS-015C MAT9130001 (4 G 1,5+(2x1,0)C)C 12,5EWLMxxxGMS-025 MAT9130002 (4 G 2,5+(2x1,0)C)C 13,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu315


ServoPVC<strong>Chainflex</strong> ® -PVC-Servo cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Moss green (similar to RAL 6005)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmLENZEEYP0010AxxxxM01A00 MAT9130050 (4 G 1,5+(2x1)C)C 12,5EYP0011AxxxxM01A00 MAT9130051 (4 G 1,5+(2x1)C)C 12,5EYP0012AxxxxM01A00 MAT9130052 (4 G 2,5+(2x1)C)C 13,5EYP0012AxxxxM02A00 MAT9130053 (4 G 2,5+(2x1)C)C 13,5EYP0013AxxxxM02A00 MAT9130054 (4 G 4,0+(2x1)C)C 15,5EYP0014AxxxxM03A00 MAT9130055 (4 G 6,0+(2x1)C)C 18,0EYP0015AxxxxM03A00 MAT9130056 (4 G 10,0+(2x1)C)C 22,0EYP0016AxxxxM03A00 MAT9130057 (4 G 16,0+(2x1)C)C 24,5EYP0012xxxxA00P02 MAT9130058 (4 G 2,5+(2x1)C)C 13,5EYP0013xxxxA00P02 MAT9130059 (4 G 4,0+(2x1)C)C 15,5EYP0014xxxxA00P03 MAT9130060 (4 G 6,0+(2x1)C)C 22,0EYP0015xxxxA00P03 MAT9130061 (4 G 10,0+(2x1)C)C 22,0EYP0016xxxxA00P03 MAT9130062 (4 G 16,0+(2x1)C)C 24,5EYP0010xxxxA00P01 MAT9130063 (4 G 1,5+(2x1)C)C 12,5EYP0011xxxxA00P01 MAT9130064 (4 G 1,5+(2x1)C)C 12,5EYP0012xxxxA00P01 MAT9130065 (4 G 2,5+(2x1)C)C 13,5LenzeLinking cableNUMEWLMxxxZM-015C MAT9130006 (4 G 1,5+(2x1,0)C)C 12,5EWLMxxxZM-025 MAT9130007 (4 G 2,5+(2x1,0)C)C 13,5EYP0012xxxxM02P02 MAT9130066 (4 G 2,5+(2x1)C)C 13,5EYP0013xxxxM02P02 MAT9130067 (4 G 4,0+(2x1)C)C 15,5EYP0014xxxxM03P03 MAT9130068 (4 G 6,0+(2x1)C)C 18,0EYP0015xxxxM03P03 MAT9130069 (4 G 10,0+(2x1)C)C 22,0EYP0016xxxxM03P03 MAT9130070 (4 G 16,0+(2x1)C)C 24,5EYP0010xxxxM01P01 MAT9130071 (4 G 1,5+(2x1)C)C 12,5EYP0011xxxxM01P01 MAT9130072 (4 G 1,5+(2x1)C)C 12,5EYP0012xxxxM01P01 MAT9130073 (4 G 2,5+(2x1)C)C 13,5NUMBasic cableAGOFRU018Mxxx MAT9280001 (4 G 1,5+(2x1)C)C 12,5AGOFRU019Mxxx MAT9280002 (4 G 4,0+(2x1,5)C)C 16,0All <strong>cables</strong> available in the lengths you require.316Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameterManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmNUMBasic cable*AGOFRU020Mxxx MAT9280003 (4 G 10,0+(2x1,5)C)C 22,5NUMNUMExtension cableAGOFRU018Mxxx MAT9280011 (4 G 1,5+(2x1)C)C 12,5AGOFRU019Mxxx MAT9280012 (4 G 4,0+(2x1,5)C)C 16,0NUMExtension cableAGOFRU020Mxxx MAT9280013 (4 G 10,0+(2x1,5)C)C 22,5RexrothBasic cableREXROTHIKG0001 MAT9190022 (4G1,0+2x(2x0,75)C)C 13,5IKG0006 MAT9190067 (4G1,0+2x(2x0,75)C)C 13,5IKG0011 MAT9190023 (4G1,0+2x(2x0,75)C)C 13,5IKG0021 MAT9190024 (4G2,5+2x(2x1,5)C)C 16,0IKG0041 MAT9190017 (4G2,5+2x(2x1,5)C)C 16,0IKG0042 MAT9190077 (4G2,5+2x(2x1,5)C)C 16,0IKG0061 MAT9190018 (4G4,0+2x(2x1,5)C)C 18,0IKG0081 MAT9190030 (4G6,0+2x(2x1,5)C)C 19,5IKG0101 MAT9190025 (4G6,0+2x(2x1,5)C)C 19,5IKG0121 MAT9190019 (4G10,0+2x(2x1,5)C)C 23,5IKG0161 MAT9190063 (4G25,0+2x(2x1,5)C)C 30,0IKG0331 MAT9190014 (4G0,75+(2x0,5)C)C 11,0IKG4008 MAT9190064 (4G1,5+2x(2x0,75)C)C 14,5IKG4009 MAT9190001 (4G1,5+2x(2x0,75)C)C 14,5IKG4017 MAT9190002 (4G1,5+2x(2x0,75)C)C 14,5IKG4018 MAT9190003 (4G1,5+2x(2x0,75)C)C 14,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu317


ServoPVC<strong>Chainflex</strong> ® -PVC-Servo cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Moss green (similar to RAL 6005)Manufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmREXROTHIKG4020 MAT9190004 (4G1,5+2x(2x0,75)C)C 14,5IKG4055 MAT9190005 (4G1,5+2x(2x0,75)C)C 14,5IKG4060 MAT9190006 (4G1,5+2x(2x0,75)C)C 14,5IKG4067 MAT9190007 (4G2,5+2x(2x1,5)C)C 16,5IKG4070 MAT9190008 (4G2,5+2x(2x1,5)C)C 16,5IKG4072 MAT9190068 (4G2,5+2x(2x1,5)C)C 16,5IKG4087 MAT9190009 (4G4,0+2x(2x1,5)C)C 18,5IKG4090 MAT9190010 (4G4,0+2x(2x1,5)C)C 18,5IKG4100 MAT9190020 (4G1,0+2x(2x0,75)C)C 13,5IKG4103 MAT9190076 (4G6,0+2x(2x1,5)C)C 20,5IKG4107 MAT9190011 (4G6,0+2x(2x1,5)C)C 20,5IKG4118 MAT9190070 (4G6,0+2x(2x1,5)C)C 20,5IKG4119 MAT9190027 (4G1,0+2x(2x0,75)C)C 13,5IKG4147 MAT9190038 (4G6,0+2x(2x1,5)C)C 20,5IKG4150 MAT9190012 (4G6,0+2x(2x1,5)C)C 20,5IKG4155 MAT9190028 (4G6,0+2x(2x1,5)C)C 19,5IKG4164 MAT9190035 (4G10,0+2x(2x1,5)C)C 23,5IKG4167 MAT9190013 (4G10,0+2x(2x1,5)C)C 24,0IKG4172 MAT9190069 (4G16,0+2x(2x1,5)C)C 26,0IKG4173 MAT9190072 (4G25,0+2x(2x1,5)C)C 30,0IKG4186 MAT9190021 (4G16,0+2x(2x1,5)C)C 26,0IKG4200 MAT9190032 (4G16,0+2x(2x1,5)C)C 26,0IKG4204 MAT9190052 (4G25,0+2x(2x1,5)C)C 30,0RexrothConnecting cablewith adapter plugsIKG0023 MAT9191013 (4G1,5+2x(2x0,75)C)C 14,5IKG0089 MAT9191005 (4G6,0+2x(2x1,5)C)C 19,5IKG0168 MAT9191006 (4G25,0+2x(2x1,5)C)C 30,0IKG0332 MAT9190015 (4G0,75+(2x0,5)C)C 11,0IKG4006 MAT9191001 (4G1,5+2x(2x0,75)C)C 14,5IKG4016 MAT9191002 (4G1,5+2x(2x0,75)C)C 14,5IKG4061 MAT9191004 (4G2,5+2x(2x1,5)C)C 16,5IKG4074 MAT9191014 (4G2,5+2x(2x1,5)C)C 16,5IKG4081 MAT9191016 (4G6,0+2x(2x1,5)C)C 20,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core318950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameterManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmIKG4141 MAT9191003 (4G6,0+2x(2x1,5)C)C 19,5IKG4161 MAT9191036 (4G10,0+2x(2x1,5)C)C 23,5RexrothBasic cableREXROTHRKL4300 MAT9190071 (4G1,5+2x(2x0,75)C)C 14,5RKL4301 MAT9190037 (4G1,5+2x(2x0,75)C)C 14,5RKL4302 MAT9190026 (4G1,0+2x(2x0,75)C)C 13,5RKL4303 MAT9190029 (4G1,0+2x(2x0,75)C)C 13,5RKL4306 MAT9190040 (4G1,5+2x(2x0,75)C)C 14,5RKL4307 MAT9190041 (4G1,5+2x(2x0,75)C)C 14,5RKL4308 MAT9190033 (4G2,5+2x(2x1,5)C)C 16,0RKL4309 MAT9190042 (4G2,5+2x(2x1,5)C)C 16,0RKL4310 MAT9190043 (4G2,5+2x(2x1,5)C)C 16,0RKL4313 MAT9190062 (4G4,0+2x(2x1,5)C)C 18,0RKL4314 MAT9190060 (4G4,0+2x(2x1,5)C)C 18,8RKL4315 MAT9190059 (4G4,0+2x(2x1,5)C)C 18,0RKL4317 MAT9190061 (4G6,0+2x(2x1,5)C)C 19,5RKL4318 MAT9190047 (4G6,0+2x(2x1,5)C)C 19,5RKL4320 MAT9190039 (4G1,5+2x(2x0,75)C)C 14,5RKL4321 MAT9190075 (4G2,5+2x(2x1,5)C)C 16,0RKL4322 MAT9190078 (4G4,0+2x(2x1,5)C)C 18,0RKL4323 MAT9190073 (4G6,0+2x(2x1,5)C)C 19,5RKL4324 MAT9190079 (4G10,0+2x(2x1,5)C)C 23,5RKL4325 MAT9190049 (4G1,5+2x(2x0,75)C)C 14,5RKL4326 MAT9190045 (4G2,5+2x(2x1,5)C)C 16,0RKL4327 MAT9190050 (4G4,0+2x(2x1,5)C)C 18,0RKL4328 MAT9190057 (4G6,0+2x(2x1,5)C)C 19,5RKL4329 MAT9190051 (4G10,0+2x(2x1,5)C)C 23,5RKL4330 MAT9190080 (4G16,0+2x(2x1,5)C)C 26,0RKL4331 MAT9190081 (4G25,0+2x(2x1,5)C)C 30,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu319


ServoPVC<strong>Chainflex</strong> ® -PVC-Servo cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Moss green (similar to RAL 6005)Manufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmREXROTHSEWRexrothConnecting cablewith adapter plugsRKL4304 MAT9191007 (4G1,5+2x(2x0,75)C)C 14,5RKL4305 MAT9191008 (4G1,0+2x(2x0,75)C)C 13,5RKL4311 MAT9191009 (4G1,5+2x(2x0,75)C)C 14,5RKL4312 MAT9191010 (4G2,5+2x(2x1,5)C)C 16,0RKL4316 MAT9191011 (4G4,0+2x(2x1,5)C)C 18,0RKL4319 MAT9191012 (4G6,0+2x(2x1,5)C)C 19,5RKL4336 MAT9191018 (4G2,5+2x(2x1,5)C)C 16,0RKL4338 MAT9191017 (4G6,0+2x(2x1,5)C)C 19,5RKL4340 MAT9191015 (4G16,0+2x(2x1,5)C)C 26,0SEWConnection cable(Amphenol)199 190 6 MAT9410001 (4 G 1,5+2x(2x0,75)C)C 14,5199 192 2 MAT9410002 (4 G 2,5+2x(2x1,5)C)C 16,5199 194 9 MAT9410003 (4 G 4+2x(2x1,5)C)C 18,0199 196 5 MAT9410004 (4 G 6+2x(2x1,5)C)C 19,5199 198 1 MAT9410005 (4 G 10+2x(2x1,5)C)C 23,5SEWExtension cable(Amphenol)199 200 7 MAT9411001 (4 G 1,5+2x(2x0,75)C)C 14,5199 202 3 MAT9411002 (4 G 2,5+2x(2x1,5)C)C 17,0199 204 X MAT9411003 (4 G 4+2x(2x1,5)C)C 18,5199 206 6 MAT9411004 (4 G 6+2x(2x1,5)C)C 20,5199 208 2 MAT9411005 (4 G 10+2x(2x1,5)C)C 24,0SEWConnection cable(Amphenol)1332 486 1 MAT9410011 (4 G 1,5+1x(2x1,0)C)C 12,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core320950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameterManufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmSEWSEWExtension cable(Amphenol)0593 650 0 MAT9411011 (4 G 1,5+1x(2x1,0)C)C 12,5SiemensBasic cable6FX8002-5DA01 MAT9160001 (4 G 1,5+(2x1,0)C)C 12,56FX8002-5DA11 MAT9160002 (4 G 2,5+(2x1,0)C)C 13,5SiemensBasic cableSIEMENS6FX8002-5DA21 MAT9160003 (4 G 1,5+(2x1,0)C)C 12,56FX8002-5DA31 MAT9160004 (4 G 2,5+(2x1,0)C)C 13,56FX8002-5DA41 MAT9160005 (4 G 4,0+(2x1,0)C)C 15,56FX8002-5DA51 MAT9160006 (4 G 6,0+(2x1,0)C)C 18,06FX8002-5DA61 MAT9160007 (4 G 10,0+(2x1,5)C)C 22,0SiemensBasic cable6FX8002-5DA23 MAT9160008 (4 G 16,0+(2x1,0)C)C 24,56FX8002-5DA33 MAT9160009 (4 G 25,0+(2x1,5)C)C 29,56FX8002-5DA43 MAT9160010 (4 G 35,0+(2x1,5)C)C 33,0SiemensBasic cable6FX8002-5DS01 MAT9160020 (4G1,5+(2x1,0)C)C 12,56FX8002-5DS21 MAT9160021 (4G1,5+(2x1,0)C)C 12,56FX8002-5DS61 MAT9160022 (4G10,0+(2x1,5)C)C 22,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu321


ServoPVC<strong>Chainflex</strong> ® -PVC-Servo cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Moss green (similar to RAL 6005)Manufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmSiemensExtension cable6FX8002-5DA05 MAT9161001 (4 G 1,5+(2x1,0)C)C 12,56FX8002-5DA15 MAT9161002 (4 G 2,5+(2x1,0)C)C 13,5SIEMENSSiemensExtension cable6FX8002-5DA28 MAT9161003 (4 G 1,5+(2x1,0)C)C 12,56FX8002-5DA38 MAT9161004 (4 G 2,5+(2x1,0)C)C 13,56FX8002-5DA48 MAT9161005 (4 G 4,0+(2x1,0)C)C 15,56FX8002-5DA58 MAT9161006 (4 G 6,0+(2x1,0)C)C 18,06FX8002-5DA68 MAT9161007 (4 G 10,0+(2x1,5)C)C 22,0SiemensExtension cable6FX8002-5DX28 MAT9161008 (4 G 16,0+(2x1,0)C)C 24,56FX8002-5DX38 MAT9161009 (4 G 25,0+(2x1,5)C)C 29,56FX8002-5DX48 MAT9161010 (4 G 35,0+(2x1,5)C)C 33,0STÖBERStöberiMDS5000 & iSDS4000Basic cableGr.1-Motor-1,0mm 2 MAT9430001 (4G1,0+2x(2x0,75)C)C 13,5Gr.1-Motor-1,5mm 2 MAT9430002 (4G1,5+2x(2x0,75)C)C 14,5Gr.1-Motor-2,5mm 2 MAT9430003 (4G2,5+2x(2x1,5)C)C 16,5Gr.1-Motor-4,0mm 2 MAT9430004 (4G4,0+2x(2x1,5)C)C 17,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core322950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameterManufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmSTÖBERStöberiMDS5000 & iSDS4000Basic cableGr.1,5-Motor-4,0mm 2 MAT9430005 (4G4,0+2x(2x1,5)C)C 18,5Gr.1,5-Motor-6,0mm 2 MAT9430006 (4G6,0+2x(2x1,5)C)C 20,5Gr.1,5-Motor-10,0mm 2 MAT9430007 (4G10,0+2x(2x1,5)C)C 24,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu323


ServoPUR<strong>Chainflex</strong> ® -PUR-Servo cable● Class 4.1.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 600/1000 V● Total shield: bending-resistant, tinned braidedcopper shield. Coverage approx.55 % linear, approx. 80 % optical.ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmFanucBasic cableLX660-8077-T261 MAT9200061 (4 G 1,5)C 8,5FanucBasic cableLX660-8077-T264 MAT9200064 (4 G 2,5)C 10,5LX660-8077-T266 MAT9200066 (4 G 2,5)C 10,5FanucBasic cableFANUCLX660-8077-T265 MAT9200065 (4 G 2,5)C 10,5LX660-8077-T267 MAT9200067 (4 G 2,5)C 10,5FanucBasic cableLX660-8077-T270 (1) MAT9200070 (4 G 4,0)C 12,0LX660-8077-T272 MAT9200072 (4 G 10,0)C 17,5FanucBasic cableLX660-8077-T271 (1) MAT9200071 (4 G 4,0)C 12,0LX660-8077-T273 MAT9200073 (4 G 10,0)C 17,5FanucBasic cableLX660-8077-T291 MAT9200091 (4 G 2,5)C 10,5LX660-8077-T293 (1) MAT9200093 (4 G 4,0)C 12,0All <strong>cables</strong> available in the lengths you require.324Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. Image exemplary.(1) Lieferzeit auf Anfrage.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPUR● Flame-retardant● Temperature range (moved): -20 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Pastel orange (similar to RAL 2003)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmFanucBasic cableFANUCLX660-8077-T292 (1) MAT9200092 (4 G 4,0)C 12,0FanucBasic cableLX660-8077-T296 MAT9200096 (4 G 2,5)C 10,5FanucBasic cableLX660-8077-T298 (1) MAT9200098 (4 G 4,0)C 15,5FanucBasic cableLX660-8077-T300 MAT9200300 (4 G 2,5)C 12,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.(1) Lieferzeit auf Anfrage.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu325


ServoPUR<strong>Chainflex</strong> ® -PUR-Servo cable● Class 6.3.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmB&RBasic cableB&Ri8CMxxx.12-1 MAT9600001 (4 G 1,5+2x(2x0,75)C)C 14,5i8CMxxx.12-3 MAT9600002 (4 G 4,0+2x(2x1,5)C)C 18,0B&RBasic cablei8CMxxx.12-5 MAT9600003 (4 G 10,0+2x(2x1,5)C)C 23,5Baumüller15 A-Basic cable*BAUMÜLLER324781 (5 m) MAT9296001 (4 G 1,5+2x(2x0,75)C)C 14,5324782 (7 m) MAT9296002 (4 G 1,5+2x(2x0,75)C)C 14,5324783 (10 m) MAT9296003 (4 G 1,5+2x(2x0,75)C)C 14,5324784 (15 m) MAT9296004 (4 G 1,5+2x(2x0,75)C)C 14,5324785 (20 m) MAT9296005 (4 G 1,5+2x(2x0,75)C)C 14,5324786 (25 m) MAT9296006 (4 G 1,5+2x(2x0,75)C)C 14,5324787 (30 m) MAT9296007 (4 G 1,5+2x(2x0,75)C)C 14,5324788 (35 m) MAT9296008 (4 G 1,5+2x(2x0,75)C)C 14,5324789 (40 m) MAT9296009 (4 G 1,5+2x(2x0,75)C)C 14,5324790 (50 m) MAT9296010 (4 G 1,5+2x(2x0,75)C)C 14,5324791 (75 m) MAT9296011 (4 G 1,5+2x(2x0,75)C)C 14,5324792 (100 m) MAT9296012 (4 G 1,5+2x(2x0,75)C)C 14,5Baumüller15 A-Extension cableMAT9298001 (4 G 1,5+2x(2x0,75)C)C 14,5All <strong>cables</strong> available in the lengths you require.326Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPUR● Flame-retardant● Temperature range (moved): -20 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter● Colour: Pastel orange (similar to RAL 2003)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmBaumüller20 A-Basic cable*BAUMÜLLER414840 (5 m) MAT9296020 (4 G 2,5+2x(2x1,5)C)C 16,5380967 (7 m) MAT9296021 (4 G 2,5+2x(2x1,5)C)C 16,5413410 (10 m) MAT9296022 (4 G 2,5+2x(2x1,5)C)C 16,5414841 (15 m) MAT9296023 (4 G 2,5+2x(2x1,5)C)C 16,5414842 (20 m) MAT9296024 (4 G 2,5+2x(2x1,5)C)C 16,5414843 (25 m) MAT9296025 (4 G 2,5+2x(2x1,5)C)C 16,5414846 (30 m) MAT9296026 (4 G 2,5+2x(2x1,5)C)C 16,5414848 (35 m) MAT9296027 (4 G 2,5+2x(2x1,5)C)C 16,5414849 (40 m) MAT9296028 (4 G 2,5+2x(2x1,5)C)C 16,5414850 (50 m) MAT9296029 (4 G 2,5+2x(2x1,5)C)C 16,5414851 (75 m) MAT9296030 (4 G 2,5+2x(2x1,5)C)C 16,5414852 (100 m) MAT9296031 (4 G 2,5+2x(2x1,5)C)C 16,5Baumüller20 A-Extension cableMAT9298020 (4 G 2,5+2x(2x1,5)C)C 16,5Baumüller21 A-Basic cable*326577 (5 m) MAT9296040 (4 G 2,5+2x(2x1,5)C)C 16,5326578 (7 m) MAT9296041 (4 G 2,5+2x(2x1,5)C)C 16,5326579 (10 m) MAT9296042 (4 G 2,5+2x(2x1,5)C)C 16,5326580 (15 m) MAT9296043 (4 G 2,5+2x(2x1,5)C)C 16,5326581 (20m) MAT9296044 (4 G 2,5+2x(2x1,5)C)C 16,5326582 (25 m) MAT9296045 (4 G 2,5+2x(2x1,5)C)C 16,5326583 (30 m) MAT9296046 (4 G 2,5+2x(2x1,5)C)C 16,5326584 (35 m) MAT9296047 (4 G 2,5+2x(2x1,5)C)C 16,5326585 (40 m) MAT9296048 (4 G 2,5+2x(2x1,5)C)C 16,5326586 (50 m) MAT9296049 (4 G 2,5+2x(2x1,5)C)C 16,5326587 (70m) MAT9296050 (4 G 2,5+2x(2x1,5)C)C 16,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu327


ServoPUR<strong>Chainflex</strong> ® -PUR-Servo cable● Class 6.3.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømm326588 (100 m) MAT9296051 (4 G 2,5+2x(2x1,5)C)C 16,5Baumüller21 A-Extension cableMAT9298040 (4 G 2,5+2x(2x1,5)C)C 16,5Baumüller28 A-Basic cable*BAUMÜLLER326589 (5 m) MAT9296060 (4 G 4+2x(2x1,5)C)C 18,0326591 (7 m) MAT9296061 (4 G 4+2x(2x1,5)C)C 18,0326592 (10 m) MAT9296062 (4 G 4+2x(2x1,5)C)C 18,0326593 (15 m) MAT9296063 (4 G 4+2x(2x1,5)C)C 18,0326594 (20m) MAT9296064 (4 G 4+2x(2x1,5)C)C 18,0326596 (25 m) MAT9296065 (4 G 4+2x(2x1,5)C)C 18,0326597 (30 m) MAT9296066 (4 G 4+2x(2x1,5)C)C 18,0326598 (35 m) MAT9296067 (4 G 4+2x(2x1,5)C)C 18,0326599 (40 m) MAT9296068 (4 G 4+2x(2x1,5)C)C 18,0Baumüller28 A-Extension cableMAT9298060 (4 G 4+2x(2x1,5)C)C 18,0Baumüller36 A-Basic cable*326600 (5 m) MAT9296070 (4 G 6+2x(2x1,5)C)C 19,5326601 (7 m) MAT9296071 (4 G 6+2x(2x1,5)C)C 19,5326602 (10 m) MAT9296072 (4 G 6+2x(2x1,5)C)C 19,5326603 (15 m) MAT9296073 (4 G 6+2x(2x1,5)C)C 19,5326604 (20m) MAT9296074 (4 G 6+2x(2x1,5)C)C 19,5326605 (25 m) MAT9296075 (4 G 6+2x(2x1,5)C)C 19,5326606 (30 m) MAT9296076 (4 G 6+2x(2x1,5)C)C 19,5326607 (35 m) MAT9296077 (4 G 6+2x(2x1,5)C)C 19,5All <strong>cables</strong> available in the lengths you require.328Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPUR● Flame-retardant● Temperature range (moved): -20 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter● Colour: Pastel orange (similar to RAL 2003)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømm326608 (40 m) MAT9296078 (4 G 6+2x(2x1,5)C)C 19,5Baumüller36 A-Extension cableMAT9298070 (4 G 6+2x(2x1,5)C)C 19,5BAUMÜLLERBaumüller50 A-Basic cable*326609 (5 m) MAT9296080 (4 G 10+2x(2x1,5)C)C 23,5326610 (7 m) MAT9296081 (4 G 10+2x(2x1,5)C)C 23,5326611 (10 m) MAT9296082 (4 G 10+2x(2x1,5)C)C 23,5326612 (15 m) MAT9296083 (4 G 10+2x(2x1,5)C)C 23,5326613 (20m) MAT9296084 (4 G 10+2x(2x1,5)C)C 23,5326614 (25 m) MAT9296085 (4 G 10+2x(2x1,5)C)C 23,5326615 (30 m) MAT9296086 (4 G 10+2x(2x1,5)C)C 23,5326616 (35 m) MAT9296087 (4 G 10+2x(2x1,5)C)C 23,5326617 (40 m) MAT9296088 (4 G 10+2x(2x1,5)C)C 23,5Baumüller50 A-Extension cableMAT9298080 (4 G 10+2x(2x1,5)C)C 23,5BeckhoffBasic cableBECKHOFFZK4000-2111-xxxx MAT9372005 (4 G 1,5+(2x1)C)C 12,5BeckhoffBasic cableZK4000-2112-xxxx MAT9372006 (4 G 2,5+(2x1)C)C 13,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu329


ServoPUR<strong>Chainflex</strong> ® -PUR-Servo cable● Class 6.3.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmBeckhoffBasic cableZK4500-0023-xxxx MAT9372001 (4 G 1,5+2x(2x0,75)C)C 14,5BECKHOFFBeckhoffBasic cableZK4500-0024-xxxx MAT9372002 (4 G 2,5+2x(2x1,5)C)C 17,5BeckhoffExtension cableZK4501-0023-xxxx MAT9372003 (4 G 1,5+2x(2x0,75)C)C 14,5BeckhoffExtension cableZK4501-0024-xxxx MAT9372004 (4 G 2,5+2x(2x1,5)C)C 17,5BERGER LAHRCONTROL TECHNIQUESBerger LahrBasic cableVW3M5101Rxxx MAT94500001 (4 G 1,5+(2x1)C)C 12,5VW3M5102Rxxx MAT94500003 (4 G 2,5+(2x1)C)C 13,5Control TechniquesBasic cablePB B G A A XXX MAT9540040 (4 G 1,5+(2x1)C)C 12,5PB B A A A XXX MAT9540041 (4 G 2,5+(2x1)C)C 13,5PB B B A A XXX MAT9540042 (4 G 4,0+(2x1)C)C 16,0PB B G F A XXX MAT9540043 (4 G 1,5+(2x1)C)C 12,5PB B A F A XXX MAT9540044 (4 G 2,5+(2x1)C)C 13,5PB B B F A XXX MAT9540045 (4 G 4,0+(2x1)C)C 16,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core330950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPUR● Flame-retardant● Temperature range (moved): -20 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter● Colour: Pastel orange (similar to RAL 2003)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmControl TechniquesBasic cableCONTROL TECHNIQUESPB B G A B XXX MAT9540046 (4 G 1,5+(2x1)C)C 12,5PB B A A B XXX MAT9540047 (4 G 2,5+(2x1)C)C 13,5PB B B A B XXX MAT9540048 (4 G 4,0+(2x1)C)C 16,0PB B C A B XXX MAT9540049 (4 G 6,0+(2x1)C)C 17,5PB B D A B XXX MAT9540050 (4 G 10,0+(2x1)C)C 20,5PB B E A B XXX MAT9540051 (4 G 16,0+(2x1)C)C 23,0PB B G F B XXX MAT9540052 (4 G 1,5+(2x1)C)C 12,5PB B A F B XXX MAT9540053 (4 G 2,5+(2x1)C)C 13,5PB B B F B XXX MAT9540054 (4 G 4,0+(2x1)C)C 16,0PB B C F B XXX MAT9540055 (4 G 6,0+(2x1)C)C 17,5PB B D F B XXX MAT9540056 (4 G 10,0+(2x1)C)C 20,5PB B E F B XXX MAT9540057 (4 G 16,0+(2x1)C)C 23,0PB B G B B XXX MAT9540058 (4 G 1,5+(2x1)C)C 12,5PB B A B B XXX MAT9540059 (4 G 2,5+(2x1)C)C 13,5PB B B B B XXX MAT9540060 (4 G 4,0+(2x1)C)C 16,0PB B C B B XXX MAT9540061 (4 G 6,0+(2x1)C)C 17,5PB B D B B XXX MAT9540062 (4 G 10,0+(2x1)C)C 20,5PB B E B B XXX MAT9540063 (4 G 16,0+(2x1)C)C 23,0PB B G G B XXX MAT9540064 (4 G 1,5+(2x1)C)C 12,5PB B A G B XXX MAT9540065 (4 G 2,5+(2x1)C)C 13,5PB B B G B XXX MAT9540066 (4 G 4,0+(2x1)C)C 16,0PB B C G B XXX MAT9540067 (4 G 6,0+(2x1)C)C 17,5PB B D G B XXX MAT9540068 (4 G 10,0+(2x1)C)C 20,5PB B E G B XXX MAT9540069 (4 G 16,0+(2x1)C)C 23,0DANAHER MOTIONDanaher MotionBasic cable107491 (5 m) MAT9440001 (4 G 1,5+(2x1)C)C 12,5107492 (10 m) MAT9440005 (4 G 1,5+(2x1)C)C 12,5107493 (15 m) MAT9440006 (4 G 1,5+(2x1)C)C 12,5107494 (20 m) MAT9440007 (4 G 1,5+(2x1)C)C 12,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu331


ServoPUR<strong>Chainflex</strong> ® -PUR-Servo cable● Class 6.3.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmDANAHER MOTION107495 (25 m) MAT9440008 (4 G 1,5+(2x1)C)C 12,5107479 (5 m) MAT9440009 (4 G 1,5+(2x1)C)C 12,5107480 (10 m) MAT9440010 (4 G 1,5+(2x1)C)C 12,5107481 (15 m) MAT9440011 (4 G 1,5+(2x1)C)C 12,5107482 (20 m) MAT9440012 (4 G 1,5+(2x1)C)C 12,5107483 (25 m) MAT9440013 (4 G 1,5+(2x1)C)C 12,5102579 (5 m) MAT9440014 (4 G 1,5+(2x1)C)C 12,5102580 (10 m) MAT9440015 (4 G 1,5+(2x1)C)C 12,5102809 (15 m) MAT9440016 (4 G 1,5+(2x1)C)C 12,5102810 (20 m) MAT9440017 (4 G 1,5+(2x1)C)C 12,5102811 (25 m) MAT9440018 (4 G 1,5+(2x1)C)C 12,590088 (5 m) MAT9440019 (4 G 1,5+(2x1)C)C 12,590089 (10 m) MAT9440020 (4 G 1,5+(2x1)C)C 12,590090 (15 m) MAT9440021 (4 G 1,5+(2x1)C)C 12,590091 (20 m) MAT9440022 (4 G 1,5+(2x1)C)C 12,590092 (25 m) MAT9440023 (4 G 1,5+(2x1)C)C 12,589957 (5 m) MAT9440024 (4 G 1,5+(2x1)C)C 12,589961 (10 m) MAT9440025 (4 G 1,5+(2x1)C)C 12,589963 (15 m) MAT9440026 (4 G 1,5+(2x1)C)C 12,589965 (20 m) MAT9440027 (4 G 1,5+(2x1)C)C 12,589967 (25 m) MAT9440028 (4 G 1,5+(2x1)C)C 12,5Danaher MotionBasic cable89968 (5 m) MAT9440029 (4 G 2,5+(2x1)C)C 13,589970 (10 m) MAT9440030 (4 G 2,5+(2x1)C)C 13,589971 (15 m) MAT9440031 (4 G 2,5+(2x1)C)C 13,589972 (20 m) MAT9440032 (4 G 2,5+(2x1)C)C 13,589969 (25 m) MAT9440033 (4 G 2,5+(2x1)C)C 13,5200462 (5 m) MAT9440034 (4 G 1,5+(2x1)C)C 12,5200463 (10 m) MAT9440035 (4 G 1,5+(2x1)C)C 12,5200464 (15 m) MAT9440036 (4 G 1,5+(2x1)C)C 12,5200465 (20 m) MAT9440037 (4 G 1,5+(2x1)C)C 12,5200466 (25 m) MAT9440038 (4 G 1,5+(2x1)C)C 12,5200474 (5 m) MAT9440039 (4 G 2,5+(2x1)C)C 13,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core332950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPUR● Flame-retardant● Temperature range (moved): -20 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter● Colour: Pastel orange (similar to RAL 2003)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmDANAHER MOTION200475 (10 m) MAT9440040 (4 G 2,5+(2x1)C)C 13,5200476 (15 m) MAT9440041 (4 G 2,5+(2x1)C)C 13,5200477 (20 m) MAT9440042 (4 G 2,5+(2x1)C)C 13,5200478 (25 m) MAT9440043 (4 G 2,5+(2x1)C)C 13,5200623 (5 m) MAT9440044 (4 G 4,0+(2x1)C)C 16,0200624 (10 m) MAT9440045 (4 G 4,0+(2x1)C)C 16,0200625 (15 m) MAT9440046 (4 G 4,0+(2x1)C)C 16,0200626 (20 m) MAT9440047 (4 G 4,0+(2x1)C)C 16,0200627 (25 m) MAT9440048 (4 G 4,0+(2x1)C)C 16,0ELAUBasic cableE-MO-067 MAT9470101 (4 G 1,5+2x(2x0,75)C)C 14,5E-MO-092 MAT9470104 (4 G 1,5+2x(2x0,75)C)C 14,5ELAUBasic cableFANUC ELAUE-MO-111 SH-Motor 1,5 MAT9470102 (4 G 1,5+2x(2x0,75)C)C 14,5ELAUBasic cableE-MO-087 MAT9470103 (4 G 2,5+2x(2x1,5)C)C 16,5ELAUBasic cableE-MO-113 SH-Motor 2.5 MAT9470105 (4 G 2,5+2x(2x1,5)C)C 16,5FanucBasic cableLX660-8077-T261 MAT9210061 (4 G 1,5)C 10,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu333


ServoPUR<strong>Chainflex</strong> ® -PUR-Servo cable● Class 6.3.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmFanucBasic cableLX660-8077-T264 MAT9210064 (4 G 2,5)C 12,0LX660-8077-T266 MAT9210066 (4 G 2,5)C 12,0FanucBasic cableLX660-8077-T265 MAT9210065 (4 G 2,5)C 12,0LX660-8077-T267 MAT9210067 (4 G 2,5)C 12,0FanucBasic cableFANUCLX660-8077-T270* MAT9210070 (4 G 4,0)C 15,5LX660-8077-T272 MAT9210072 (4 G 10,0)C 20,5FanucBasic cableLX660-8077-T271* MAT9210071 (4 G 4,0)C 15,5LX660-8077-T273 MAT9210073 (4 G 10,0)C 20,5FanucBasic cableLX660-8077-T291 MAT9210091 (4 G 2,5)C 12,0LX660-8077-T293* MAT9210093 (4 G 4,0)C 15,5FanucBasic cableLX660-8077-T292* MAT9210092 (4 G 4,0)C 15,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core334950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPUR● Flame-retardant● Temperature range (moved): -20 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter● Colour: Pastel orange (similar to RAL 2003)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmFanucBasic cableFANUCLX660-8077-T296 MAT9210096 (4 G 2,5)C 12,0FanucBasic cableLX660-8077-T298* MAT9210098 (4 G 4,0)C 15,5FanucBasic cableLX660-8077-T300 MAT9210300 (4 G 2,5)C 12,0LenzeBasic cable*LENZEEWLMxxxGMS-015C MAT9120001 (4 G 1,5+(2x1,0)C)C 12,5EWLMxxxGMS-025 MAT9120002 (4 G 2,5+(2x1,0)C)C 13,5EYP0010AxxxxM01A00 MAT9120050 (4 G 1,5+(2x1,0)C)C 12,5EYP0011AxxxxM01A00 MAT9120051 (4 G 1,5+(2x1,0)C)C 12,5EYP0012AxxxxM01A00 MAT9120052 (4 G 2,5+(2x1,0)C)C 13,5EYP0012AxxxxM02A00 MAT9120053 (4 G 2,5+(2x1,0)C)C 13,5EYP0013AxxxxM02A00 MAT9120054 (4 G 4,0+(2x1,0)C)C 15,5EYP0014AxxxxM03A00 MAT9120055 (4 G 6,0+(2x1,0)C)C 17,5EYP0015AxxxxM03A00 MAT9120056 (4 G 10,0+(2x1,0)C)C 20,5EYP0016AxxxxM03A00 MAT9120057 (4 G 16,0+(2x1,0)C)C 23,0EYP0012xxxxA00P02 MAT9120058 (4 G 2,5+(2x1,0)C)C 13,5EYP0013xxxxA00P02 MAT9120059 (4 G 4,0+(2x1,0)C)C 15,5EYP0014xxxxA00P03 MAT9120060 (4 G 6,0+(2x1,0)C)C 20,5EYP0015xxxxA00P03 MAT9120061 (4 G 10,0+(2x1,0)C)C 20,5EYP0016xxxxA00P03 MAT9120062 (4 G 16,0+(2x1,0)C)C 23,0EYP0010xxxxA00P01 MAT9120063 (4 G 1,5+(2x1,0)C)C 12,5EYP0011xxxxA00P01 MAT9120064 (4 G 1,5+(2x1,0)C)C 12,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu335


ServoPUR<strong>Chainflex</strong> ® -PUR-Servo cable● Class 6.3.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmEYP0012xxxxA00P01 MAT9120065 (4 G 2,5+(2x1,0)C)C 13,5LenzeLinking cableLENZEEWLMxxxZM-015C MAT9120006 (4 G 1,5+(2x1,0)C)C 12,5EWLMxxxZM-025 MAT9120007 (4 G 2,5+(2x1,0)C)C 13,5EYP0012xxxxM02P02 MAT9120066 (4 G 2,5+(2x1)C)C 13,5EYP0013xxxxM02P02 MAT9120067 (4 G 4,0+(2x1)C)C 15,5EYP0014xxxxM03P03 MAT9120068 (4 G 6,0+(2x1)C)C 17,5EYP0015xxxxM03P03 MAT9120069 (4 G 10,0+(2x1)C)C 20,5EYP0016xxxxM03P03 MAT9120070 (4 G 16,0+(2x1)C)C 23,0EYP0010xxxxM01P01 MAT9120071 (4 G 1,5+(2x1)C)C 12,5EYP0011xxxxM01P01 MAT9120072 (4 G 1,5+(2x1)C)C 12,5EYP0012xxxxM01P01 MAT9120073 (4 G 2,5+(2x1)C)C 13,5NUMBasic cableAGOFRU018Mxxx MAT9282001 (4 G 1,5+(2x1)C)C 12,5AGOFRU019Mxxx MAT9282002 (4 G 4,0+(2x1)C)C 16,0NUMBasic cable*NUMAGOFRU020Mxxx MAT9282003 (4 G 10,0+(2x1)C)C 20,5NUMExtension cableAGOFRU018Mxxx MAT9282011 (4 G 1,5+(2x1)C)C 12,5AGOFRU019Mxxx MAT9282012 (4 G 4,0+(2x1)C)C 16,0All <strong>cables</strong> available in the lengths you require.336Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPUR● Flame-retardant● Temperature range (moved): -20 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter● Colour: Pastel orange (similar to RAL 2003)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmNUMNUMExtension cableAGOFRU020Mxxx MAT9282013 (4 G 10,0+(2x1)C)C 20,5RexrothBasic cableREXROTHIKG0001 MAT9090022 (4G1,0+2x(2x0,75)C)C 13,5IKG0006 MAT9090067 (4G1,0+2x(2x0,75)C)C 13,5IKG0011 MAT9090023 (4G1,0+2x(2x0,75)C)C 13,5IKG0021 MAT9090024 (4G2,5+2x(2x1,5)C)C 16,0IKG0041 MAT9090017 (4G2,5+2x(2x1,5)C)C 16,0IKG0042 MAT9090077 (4G2,5+2x(2x1,5)C)C 16,0IKG0061 MAT9090018 (4G4,0+2x(2x1,5)C)C 18,0IKG0081 MAT9090030 (4G6,0+2x(2x1,5)C)C 19,5IKG0101 MAT9090025 (4G6,0+2x(2x1,5)C)C 19,5IKG0121 MAT9090019 (4G10,0+2x(2x1,5)C)C 23,5IKG0161 MAT9090063 (4G25,0+2x(2x1,5)C)C 30,0IKG0331 MAT9090014 (4G0,75+(2x0,5)C)C 11,5IKG4008 MAT9090064 (4G1,0+2x(2x0,75)C)C 13,5IKG4009 MAT9090001 (4G1,0+2x(2x0,75)C)C 13,5IKG4017 MAT9090002 (4G1,0+2x(2x0,75)C)C 13,5IKG4018 MAT9090003 (4G1,0+2x(2x0,75)C)C 13,5IKG4020 MAT9090004 (4G1,0+2x(2x0,75)C)C 13,5IKG4055 MAT9090005 (4G1,5+2x(2x0,75)C)C 14,5IKG4060 MAT9090006 (4G1,5+2x(2x0,75)C)C 14,5IKG4067 MAT9090007 (4G2,5+2x(2x1,5)C)C 16,0IKG4070 MAT9090008 (4G2,5+2x(2x1,5)C)C 16,0IKG4072 MAT9090068 (4G2,5+2x(2x1,5)C)C 16,0IKG4087 MAT9090009 (4G4,0+2x(2x1,5)C)C 18,0IKG4090 MAT9090010 (4G4,0+2x(2x1,5)C)C 18,0IKG4100 MAT9090020 (4G1,0+2x(2x0,75)C)C 13,5IKG4103 MAT9090076 (4G6,0+2x(2x1,5)C)C 19,5IKG4107 MAT9090011 (4G6,0+2x(2x1,5)C)C 19,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu337


ServoPUR<strong>Chainflex</strong> ® -PUR-Servo cable● Class 6.3.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmIKG4118 MAT9090070 (4G6,0+2x(2x1,5)C)C 19,5IKG4119 MAT9090027 (4G1,0+2x(2x0,75)C)C 13,5IKG4147 MAT9090038 (4G6,0+2x(2x1,5)C)C 19,5IKG4150 MAT9090012 (4G6,0+2x(2x1,5)C)C 19,5IKG4155 MAT9090028 (4G6,0+2x(2x1,5)C)C 19,5IKG4164 MAT9090035 (4G10,0+2x(2x1,5)C)C 23,5IKG4167 MAT9090013 (4G10,0+2x(2x1,5)C)C 23,5IKG4172 MAT9090069 (4G16,0+2x(2x1,5)C)C 26,0IKG4173 MAT9090072 (4G25,0+2x(2x1,5)C)C 30,0IKG4186 MAT9090021 (4G16,0+2x(2x1,5)C)C 26,0IKG4200 MAT9090032 (4G16,0+2x(2x1,5)C)C 26,0IKG4204 MAT9090052 (4G25,0+2x(2x1,5)C)C 30,0REXROTHRexrothConnecting cablewith adapter plugsIKG0023 MAT9091013 (4G1,5+2x(2x0,75)C)C 14,5IKG0089 MAT9091005 (4G6,0+2x(2x1,5)C)C 19,5IKG0168 MAT9091006 (4G25,0+2x(2x1,5)C)C 30,0IKG0332 MAT9090015 (4G0,75+(2x0,5)C)C 11,5IKG4006 MAT9091001 (4G1,0+2x(2x0,75)C)C 13,5IKG4016 MAT9091002 (4G1,0+2x(2x0,75)C)C 13,5IKG4061 MAT9091004 (4G2,5+2x(2x1,5)C)C 16,0IKG4074 MAT9091014 (4G2,5+2x(2x1,5)C)C 16,0IKG4081 MAT9091016 (4G4,0+2x(2x1,5)C)C 18,0IKG4141 MAT9091003 (4G6,0+2x(2x1,5)C)C 19,5IKG4161 MAT9090036 (4G10,0+2x(2x1,5)C)C 23,5RexrothBasic cableRKL4300 MAT9090071 (4G1,5+2x(2x0,75)C)C 14,5RKL4301 MAT9090037 (4G1,5+2x(2x0,75)C)C 14,5RKL4302 MAT9090026 (4G1,0+2x(2x0,75)C)C 13,5RKL4303 MAT9090029 (4G1,0+2x(2x0,75)C)C 13,5RKL4306 MAT9090040 (4G1,5+2x(2x0,75)C)C 14,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core338950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPUR● Flame-retardant● Temperature range (moved): -20 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter● Colour: Pastel orange (similar to RAL 2003)Manufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmREXROTHRKL4307 MAT9090041 (4G1,5+2x(2x0,75)C)C 14,5RKL4308 MAT9090033 (4G2,5+2x(2x1,5)C)C 16,0RKL4309 MAT9090042 (4G2,5+2x(2x1,5)C)C 16,0RKL4310 MAT9090043 (4G2,5+2x(2x1,5)C)C 16,0RKL4313 MAT9090062 (4G4,0+2x(2x1,5)C)C 18,0RKL4314 MAT9090060 (4G4,0+2x(2x1,5)C)C 18,0RKL4315 MAT9090059 (4G4,0+2x(2x1,5)C)C 18,0RKL4317 MAT9090061 (4G6,0+2x(2x1,5)C)C 19,5RKL4318 MAT9090047 (4G6,0+2x(2x1,5)C)C 19,5RKL4320 MAT9090039 (4G1,5+2x(2x0,75)C)C 14,5RKL4321 MAT9090075 (4G2,5+2x(2x1,5)C)C 16,0RKL4322 MAT9090078 (4G4,0+2x(2x1,5)C)C 18,0RKL4323 MAT9090073 (4G6,0+2x(2x1,5)C)C 19,5RKL4324 MAT9090079 (4G10,0+2x(2x1,5)C)C 23,5RKL4325 MAT9090049 (4G1,5+2x(2x0,75)C)C 14,5RKL4326 MAT9090045 (4G2,5+2x(2x1,5)C)C 16,0RKL4327 MAT9090050 (4G4,0+2x(2x1,5)C)C 18,0RKL4328 MAT9090057 (4G6,0+2x(2x1,5)C)C 19,5RKL4329 MAT9090051 (4G10,0+2x(2x1,5)C)C 23,5RKL4330 MAT9090080 (4G16,0+2x(2x1,5)C)C 26,0RKL4331 MAT9090081 (4G25,0+2x(2x1,5)C)C 30,0RexrothConnecting cablewith adapter plugsRKL4304 MAT9091007 (4G1,5+2x(2x0,75)C)C 14,5RKL4305 MAT9091008 (4G1,0+2x(2x0,75)C)C 13,5RKL4311 MAT9091009 (4G1,5+2x(2x0,75)C)C 14,5RKL4312 MAT9091010 (4G2,5+2x(2x1,5)C)C 16,0RKL4316 MAT9091011 (4G4,0+2x(2x1,5)C)C 18,0RKL4319 MAT9091012 (4G6,0+2x(2x1,5)C)C 19,5RKL4336 MAT9091018 (4G2,5+2x(2x1,5)C)C 16,0RKL4338 MAT9091017 (4G6,0+2x(2x1,5)C)C 19,5RKL4340 MAT9091015 (4G16,0+2x(2x1,5)C)C 26,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu339


ServoPUR<strong>Chainflex</strong> ® -PUR-Servo cable● Class 6.3.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmSEWConnection cableSEW199 190 6 MAT9400001 (4 G 1,5+2x(2x0,75)C)C 14,5199 192 2 MAT9400002 (4 G 2,5+2x(2x1,5)C)C 16,5199 194 9 MAT9400003 (4 G 4+2x(2x1,5)C)C 18,0199 196 5 MAT9400004 (4 G 6+2x(2x1,5)C)C 19,5199 198 1 MAT9400005 (4 G 10+2x(2x1,5)C)C 23,5SEWExtension cable199 200 7 MAT9401001 (4 G 1,5+2x(2x0,75)C)C 14,5199 202 3 MAT9401002 (4 G 2,5+2x(2x1,5)C)C 16,5199 204 X MAT9401003 (4 G 4+2x(2x1,5)C)C 18,0199 206 6 MAT9401004 (4 G 6+2x(2x1,5)C)C 19,5199 208 2 MAT9401005 (4 G 10+2x(2x1,5)C)C 23,5SEWConnection cable1332 486 1 MAT9400011 (4 G 1,5+1x(2x1,0)C)C 12,5SEWExtension cable0593 650 0 MAT9401011 (4 G 1,5+1x(2x1,0)C)C 12,5SIEMENSSiemensBasic cable6FX8002-5DA01 MAT9060001 (4 G 1,5+(2x1,0)C)C 12,56FX8002-5DA11 MAT9060002 (4 G 2,5+(2x1,0)C)C 13,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core340950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPUR● Flame-retardant● Temperature range (moved): -20 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter● Colour: Pastel orange (similar to RAL 2003)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmSiemensBasic cable6FX8002-5DA21 MAT9060003 (4 G 1,5+(2x1,0)C)C 12,56FX8002-5DA31 MAT9060004 (4 G 2,5+(2x1,0)C)C 13,56FX8002-5DA41 MAT9060005 (4 G 4,0+(2x1,0)C)C 15,56FX8002-5DA51 MAT9060006 (4 G 6,0+(2x1,0)C)C 17,56FX8002-5DA61 MAT9060007 (4 G 10,0+(2x1,0)C)C 20,5SiemensBasic cableSIEMENS6FX8002-5DA23 MAT9060008 (4 G 16,0+(2x1,0)C)C 24,06FX8002-5DA33 MAT9060009 (4 G 25,0+(2x1,5)C)C 28,56FX8002-5DA43 MAT9060010 (4 G 35,0+(2x1,5)C)C 32,5SiemensBasic cable6FX8002-5DS01 MAT9060020 (4G1,5+(2x1,0)C)C 12,56FX8002-5DS21 MAT9060021 (4G1,5+(2x1,0)C)C 12,56FX8002-5DS61 MAT9060022 (4G10,0+(2x1,0)C)C 20,5SiemensExtension cable6FX8002-5DA05 MAT9061001 (4 G 1,5+(2x1,0)C)C 12,56FX8002-5DA15 MAT9061002 (4 G 2,5+(2x1,0)C)C 13,5SiemensExtension cable6FX8002-5DA28 MAT9061003 (4 G 1,5+(2x1,0)C)C 12,56FX8002-5DA38 MAT9061004 (4 G 2,5+(2x1,0)C)C 13,56FX8002-5DA48 MAT9061005 (4 G 4,0+(2x1,0)C)C 15,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu341


ServoPUR<strong>Chainflex</strong> ® -PUR-Servo cable● Class 6.3.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmSIEMENS6FX8002-5DA58 MAT9061006 (4 G 6,0+(2x1,0)C)C 17,56FX8002-5DA68 MAT9061007 (4 G 10,0+(2x1,0)C)C 20,5SiemensExtension cable6FX8002-5DX28 MAT9061008 (4 G 16,0+(2x1,0)C)C 24,06FX8002-5DX38 MAT9061009 (4 G 25,0+(2x1,5)C)C 28,56FX8002-5DX48 MAT9061010 (4 G 35,0+(2x1,5)C)C 32,5STÖBERStöberiMDS5000 & iSDS4000Basic cableGr.1-Motor-1,0mm 2 MAT9420001 (4G1,0+2x(2x0,75)C)C 13,5Gr.1-Motor-1,5mm 2 MAT9420002 (4G1,5+2x(2x0,75)C)C 14,5Gr.1-Motor-2,5mm 2 MAT9420003 (4G2,5+2x(2x1,5)C)C 16,5Gr.1-Motor-4,0mm 2 MAT9420004 (4G4,0+2x(2x1,5)C)C 18,0StöberiMDS5000 & iSDS4000Basic cableGr.1,5-Motor-4,0mm 2 MAT9420005 (4G4,0+2x(2x1,5)C)C 18,0Gr.1,5-Motor-6,0mm 2 MAT9420006 (4G6,0+2x(2x1,5)C)C 19,5Gr.1,5-Motor-10,0mm 2 MAT9420007 (4G10,0+2x(2x1,5)C)C 23,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core342950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ServoPUR● Flame-retardant● Temperature range (moved): -20 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter● Colour: Pastel orange (similar to RAL 2003)... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu343


PowerPVC<strong>Chainflex</strong> ® -PVC power cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Jet black (similar to RAL 9005)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmControl TechniquesBasic cableCONTROL TECHNIQUESPS B G A A XXX MAT9560001 (4 G 1,5)C 9,5PS B A A A XXX MAT9450002 (4 G 2,5)C 11,0PS B B A A XXX MAT9560003 (4 G 4,0)C 14,0PS B G F A XXX MAT9560004 (4 G 1,5)C 9,5PS B A F A XXX MAT9560005 (4 G 2,5)C 11,0PS B B F A XXX MAT9560006 (4 G 4,0)C 14,0Control TechniquesBasic cablePS B G A B XXX MAT9560007 (4 G 1,5)C 9,5PS B A A B XXX MAT9560008 (4 G 2,5)C 11,0PS B B A B XXX MAT9560009 (4 G 4,0)C 14,0PS B C A B XXX MAT9560010 (4 G 6,0)C 15,5PS B D A B XXX MAT9560011 (4 G 10,0)C 19,5PS B E A B XXX MAT9560012 (4 G 16,0)C 22,0PS B G F B XXX MAT9560013 (4 G 1,5)C 9,5PS B A F B XXX MAT9560014 (4 G 2,5)C 11,0PS B B F B XXX MAT9560015 (4 G 4,0)C 14,0PS B C F B XXX MAT9560016 (4 G 6,0)C 15,5PS B D F B XXX MAT9560017 (4 G 10,0)C 19,5PS B E F B XXX MAT9560018 (4 G 16,0)C 22,0PS B G B B XXX MAT9560019 (4 G 1,5)C 9,5PS B A B B XXX MAT9560020 (4 G 2,5)C 11,0PS B B B B XXX MAT9560021 (4 G 4,0)C 14,0PS B C B B XXX MAT9560022 (4 G 6,0)C 15,5PS B D B B XXX MAT9560023 (4 G 10,0)C 19,5PS B E B B XXX MAT9560024 (4 G 16,0)C 22,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core344950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


PowerPVC● Temperature range (moved): -5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameterManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmDanaher MotionBasic cableDANAHER MOTION107485 (5 m) MAT9340002 (4 G 1,5)C 10,5107486 (10 m) MAT9340049 (4 G 1,5)C 10,5107487 (15 m) MAT9340050 (4 G 1,5)C 10,5107488 (20 m) MAT9340051 (4 G 1,5)C 10,5107489 (25 m) MAT9340052 (4 G 1,5)C 10,5107473 (5 m) MAT9340053 (4 G 1,5)C 10,5107474 (10 m) MAT9340054 (4 G 1,5)C 10,5107475 (15 m) MAT9340055 (4 G 1,5)C 10,5107476 (20 m) MAT9340056 (4 G 1,5)C 10,5107477 (25 m) MAT9340057 (4 G 1,5)C 10,5102575 (5 m) MAT9340058 (4 G 1,5)C 10,5102576 (10 m) MAT9340059 (4 G 1,5)C 10,5102806 (15 m) MAT9340060 (4 G 1,5)C 10,5102807 (20 m) MAT9340061 (4 G 1,5)C 10,5102808 (25 m) MAT9340062 (4 G 1,5)C 10,590083 (5 m) MAT9340063 (4 G 1,5)C 10,590084 (10 m) MAT9340064 (4 G 1,5)C 10,590085 (15 m) MAT9340065 (4 G 1,5)C 10,590086 (20 m) MAT9340066 (4 G 1,5)C 10,590087 (25 m) MAT9340067 (4 G 1,5)C 10,589918 (5 m) MAT9340068 (4 G 1,5)C 10,589952 (10 m) MAT9340069 (4 G 1,5)C 10,589953 (15 m) MAT9340070 (4 G 1,5)C 10,589954 (20 m) MAT9340071 (4 G 1,5)C 10,589956 (25 m) MAT9340072 (4 G 1,5)C 10,5Danaher MotionBasic cable89959 (5 m) MAT9340004 (4 G 2,5)C 12,589960 (10 m) MAT9340073 (4 G 2,5)C 12,589962 (15 m) MAT9340074 (4 G 2,5)C 12,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu345


PowerPVC<strong>Chainflex</strong> ® -PVC power cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Jet black (similar to RAL 9005)Manufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmDANAHER MOTION89964 (20 m) MAT9340075 (4 G 2,5)C 12,589966 (25 m) MAT9340076 (4 G 2,5)C 12,5200456 (5 m) MAT9340077 (4 G 1,5)C 10,5200457 (10 m) MAT9340078 (4 G 1,5)C 10,5200458 (15 m) MAT9340079 (4 G 1,5)C 10,5200459 (20 m) MAT9340080 (4 G 1,5)C 10,5200460 (25 m) MAT9340081 (4 G 1,5)C 10,5200468 (5 m) MAT9340082 (4 G 2,5)C 12,5200469 (10 m) MAT9340083 (4 G 2,5)C 12,5200470 (15 m) MAT9340084 (4 G 2,5)C 12,5200471 (20 m) MAT9340085 (4 G 2,5)C 12,5200472 (25 m) MAT9340086 (4 G 2,5)C 12,5200618 (5 m) MAT9340087 (4 G 4,0)C 14,0200619 (10 m) MAT9340088 (4 G 4,0)C 14,0200620 (15 m) MAT9340089 (4 G 4,0)C 14,0200621 (20 m) MAT9340090 (4 G 4,0)C 14,0200622 (25 m) MAT9340091 (4 G 4,0)C 14,0NUMBasic cableNUMAGOFRU018LMxxx MAT9280051 (4 G 1,5)C 10,5AGOFRU019LMxxx MAT9280052 (4 G 4)C 14,0NUMExtension cableAGOFRU018LMxxx MAT9280061 (4 G 1,5)C 10,5AGOFRU019LMxxx MAT9280062 (4 G 4)C 14,0SEWSEWConnection cable(Amphenol)199 180 9 MAT9410006 (4 G 1,5)C 10,5199 182 5 MAT9410007 (4 G 2,5)C 12,5199 184 1 MAT9410008 (4 G 4,0)C 14,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core346950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


PowerPVC● Temperature range (moved): -5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameterManufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mm199 186 8 MAT9410009 (4 G 6,0)C 16,0199 188 4 MAT9410010 (4 G 10,0)C 20,5SEWSEWExtension cable(Amphenol)199 550 2 MAT9411006 (4 G 1,5)C 10,5199 552 9 MAT9411007 (4 G 2,5)C 12,5199 554 5 MAT9411008 (4 G 4,0)C 14,0199 556 1 MAT9411009 (4 G 6,0)C 16,0199 558 8 MAT9411010 (4 G 10,0)C 20,5SEWConnection cable(Amphenol)0590 477 3 MAT9410012 (4 G 1,5)C 10,5SEWExtension cable(Amphenol)0590 361 0 MAT9411012 (4 G 1,5)C 9,5SiemensBasic cableSIEMENS6FX8002-5CA01 MAT9150001 (4 G 1,5)C 12,56FX8002-5CA11 MAT9150002 (4 G 2,5)C 15,0SiemensBasic cable6FX8002-5CA21 MAT9150003 (4 G 1,5)C 12,56FX8002-5CA31 MAT9150004 (4 G 2,5)C 15,06FX8002-5CA41 MAT9150005 (4 G 4,0)C 16,06FX8002-5CA51 MAT9150006 (4 G 6,0)C 19,06FX8002-5CA61 MAT9150007 (4 G 10,0)C 24,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu347


PowerPVC<strong>Chainflex</strong> ® -PVC power cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Jet black (similar to RAL 9005)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmSiemensBasic cable6FX8002-5CA23 MAT9150008 (4 G 16,0)C 27,0SiemensBasic cable6FX8002-5CS01 MAT9150020 (4 G 1,5)C 10,56FX8002-5CS21 MAT9150021 (4 G 1,5)C 10,56FX8002-5CS31 MAT9150022 (4 G 2,5)C 12,5SIEMENSSiemensExtension cable6FX8002-5CA05 MAT9151001 (4 G 1,5)C 12,56FX8002-5CA15 MAT9151002 (4 G 2,5)C 15,0SiemensExtension cable6FX8002-5CA28 MAT9151003 (4 G 1,5)C 12,56FX8002-5CA38 MAT9151004 (4 G 2,5)C 15,06FX8002-5CA48 MAT9151005 (4 G 4,0)C 16,06FX8002-5CA58 MAT9151006 (4 G 6,0)C 19,06FX8002-5CA68 MAT9151007 (4 G 10,0)C 24,0SiemensExtension cable6FX8002-5CX28 MAT9151008 (4 G 16,0)C 27,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core348950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


PowerPVC● Temperature range (moved): -5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu349


PowerTPE<strong>Chainflex</strong> ® -TPE power cable● Class 6.4.4● Oil-resistant● Shielded● Hydrolysis-resistant and microbe-resistant● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmControl TechniquesBasic cableCONTROL TECHNIQUESPS B G A A XXX MAT9540001 (4 G 1,5)C 9,5PS B A A A XXX MAT9540002 (4 G 2,5)C 11,0PS B B A A XXX MAT9540003 (4 G 4,0)C 14,0PS B G F A XXX MAT9540004 (4 G 1,5)C 9,5PS B A F A XXX MAT9540005 (4 G 2,5)C 11,0PS B B F A XXX MAT9540006 (4 G 4,0)C 14,0Control TechniquesBasic cablePS B G A B XXX MAT9540007 (4 G 1,5)C 9,5PS B A A B XXX MAT9540008 (4 G 2,5)C 11,0PS B B A B XXX MAT9540009 (4 G 4,0)C 14,0PS B C A B XXX MAT9540010 (4 G 6,0)C 15,5PS B D A B XXX MAT9540011 (4 G 10,0)C 19,5PS B E A B XXX MAT9540012 (4 G 16,0)C 22,0PS B G F B XXX MAT9540013 (4 G 1,5)C 9,5PS B A F B XXX MAT9540014 (4 G 2,5)C 11,0PS B B F B XXX MAT9540015 (4 G 4,0)C 14,0PS B C F B XXX MAT9540016 (4 G 6,0)C 15,5PS B D F B XXX MAT9540017 (4 G 10,0)C 19,5PS B E F B XXX MAT9540018 (4 G 16,0)C 22,0PS B G B B XXX MAT9540019 (4 G 1,5)C 9,5PS B A B B XXX MAT9540020 (4 G 2,5)C 11,0PS B B B B XXX MAT9540021 (4 G 4,0)C 14,0PS B C B B XXX MAT9540022 (4 G 6,0)C 15,5PS B D B B XXX MAT9540023 (4 G 10,0)C 19,5PS B E B B XXX MAT9540024 (4 G 16,0)C 22,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core350950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


PowerTPE● Temperature range (moved): -35 °C to + 90°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter● Colour: Jet black (similar to RAL 9005)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmDanaher MotionBasic cableDANAHER MOTION107485 (5 m) MAT9440002 (4 G 1,5)C 9,5107486 (10 m) MAT9440049 (4 G 1,5)C 9,5107487 (15 m) MAT9440050 (4 G 1,5)C 9,5107488 (20 m) MAT9440051 (4 G 1,5)C 9,5107489 (25 m) MAT9440052 (4 G 1,5)C 9,5107473 (5 m) MAT9440053 (4 G 1,5)C 9,5107474 (10 m) MAT9440054 (4 G 1,5)C 9,5107475 (15 m) MAT9440055 (4 G 1,5)C 9,5107476 (20 m) MAT9440056 (4 G 1,5)C 9,5107477 (25 m) MAT9440057 (4 G 1,5)C 9,5102575 (5 m) MAT9440058 (4 G 1,5)C 9,5102576 (10 m) MAT9440059 (4 G 1,5)C 9,5102806 (15 m) MAT9440060 (4 G 1,5)C 9,5102807 (20 m) MAT9440061 (4 G 1,5)C 9,5102808 (25 m) MAT9440062 (4 G 1,5)C 9,590083 (5 m) MAT9440063 (4 G 1,5)C 9,590084 (10 m) MAT9440064 (4 G 1,5)C 9,590085 (15 m) MAT9440065 (4 G 1,5)C 9,590086 (20 m) MAT9440066 (4 G 1,5)C 9,590087 (25 m) MAT9440067 (4 G 1,5)C 9,589918 (5 m) MAT9440068 (4 G 1,5)C 9,589952 (10 m) MAT9440069 (4 G 1,5)C 9,589953 (15 m) MAT9440070 (4 G 1,5)C 9,589954 (20 m) MAT9440071 (4 G 1,5)C 9,589956 (25 m) MAT9440072 (4 G 1,5)C 9,5Danaher MotionBasic cable89959 (5 m) MAT9440004 (4 G 2,5)C 11,089960 (10 m) MAT9440073 (4 G 2,5)C 11,089962 (15 m) MAT9440074 (4 G 2,5)C 11,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu351


PowerTPE<strong>Chainflex</strong> ® -TPE power cable● Class 6.4.4● Oil-resistant● Shielded● Hydrolysis-resistant and microbe-resistant● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmDANAHER MOTION89964 (20 m) MAT9440075 (4 G 2,5)C 11,089966 (25 m) MAT9440076 (4 G 2,5)C 11,0200456 (5 m) MAT9440077 (4 G 1,5)C 9,5200457 (10 m) MAT9440078 (4 G 1,5)C 9,5200458 (15 m) MAT9440079 (4 G 1,5)C 9,5200459 (20 m) MAT9440080 (4 G 1,5)C 9,5200460 (25 m) MAT9440081 (4 G 1,5)C 9,5200468 (5 m) MAT9440082 (4 G 2,5)C 11,0200469 (10 m) MAT9440083 (4 G 2,5)C 11,0200470 (15 m) MAT9440084 (4 G 2,5)C 11,0200471 (20 m) MAT9440085 (4 G 2,5)C 11,0200472 (25 m) MAT9440086 (4 G 2,5)C 11,0200618 (5 m) MAT9440087 (4 G 4,0)C 14,0200619 (10 m) MAT9440088 (4 G 4,0)C 14,0200620 (15 m) MAT9440089 (4 G 4,0)C 14,0200621 (20 m) MAT9440090 (4 G 4,0)C 14,0200622 (25 m) MAT9440091 (4 G 4,0)C 14,0NUMBasic cableNUMAGOFRU018LMxxx MAT9282051 (4 G 1,5)C 9,5AGOFRU019LMxxx MAT9282052 (4 G 4)C 14,0NUMExtension cableAGOFRU018LMxxx MAT9282061 (4 G 1,5)C 9,5AGOFRU019LMxxx MAT9282062 (4 G 4)C 14,0SEWSEWConnection cable(Amphenol)199 180 9 MAT9400006 (4 G 1,5)C 9,5199 182 5 MAT9400007 (4 G 2,5)C 11,0199 184 1 MAT9400008 (4 G 4,0)C 14,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core352950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


PowerTPE● Temperature range (moved): -35 °C to + 90°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter● Colour: Jet black (similar to RAL 9005)Manufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mm199 186 8 MAT9400009 (4 G 6,0)C 15,5199 188 4 MAT9400010 (4 G 10,0)C 19,5SEWSEWExtension cable(Amphenol)199 550 2 MAT9401006 (4 G 1,5)C 9,5199 552 9 MAT9401007 (4 G 2,5)C 11,0199 554 5 MAT9401008 (4 G 4,0)C 14,0199 556 1 MAT9401009 (4 G 6,0)C 15,5199 558 8 MAT9401010 (4 G 10,0)C 19,5SEWConnection cable(Amphenol)0590 477 3 MAT9400012 (4 G 1,5)C 9,5SEWExtension cable(Amphenol)0590 361 0 MAT9401012 (4 G 1,5)C 9,5SiemensBasic cableSIEMENS6FX8002-5CA01 MAT9050001 (4 G 1,5)C 10,06FX8002-5CA11 MAT9050002 (4 G 2,5)C 11,5SiemensBasic cable6FX8002-5CA21 MAT9050003 (4 G 1,5)C 10,06FX8002-5CA31 MAT9050004 (4 G 2,5)C 11,56FX8002-5CA41 MAT9050005 (4 G 4,0)C 13,06FX8002-5CA51 MAT9050006 (4 G 6,0)C 15,06FX8002-5CA61 MAT9050007 (4 G 10,0)C 20,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu353


PowerTPE<strong>Chainflex</strong> ® -TPE power cable● Class 6.4.4● Oil-resistant● Shielded● Hydrolysis-resistant and microbe-resistant● Flame-retardant● Nominal voltage: 600/1000 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmSiemensBasic cable6FX8002-5CA23 MAT9050008 (4 G 16,0)C 22,0SiemensBasic cable6FX8002-5CS01 MAT9050020 (4 G 1,5)C 9,56FX8002-5CS21 MAT9050021 (4 G 1,5)C 9,56FX8002-5CS31 MAT9050022 (4 G 2,5)C 11,0SIEMENSSiemensExtension cable6FX8002-5CA05 MAT9051001 (4 G 1,5)C 10,06FX8002-5CA15 MAT9051002 (4 G 2,5)C 11,5SiemensExtension cable6FX8002-5CA28 MAT9051003 (4 G 1,5)C 10,06FX8002-5CA38 MAT9051004 (4 G 2,5)C 11,56FX8002-5CA48 MAT9051005 (4 G 4,0)C 13,06FX8002-5CA58 MAT9051006 (4 G 6,0)C 15,06FX8002-5CA68 MAT9051007 (4 G 10,0)C 20,0SiemensExtension cable6FX8002-5CX28 MAT9051008 (4 G 16,0)C 22,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core354950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


PowerTPE● Temperature range (moved): -35 °C to + 90°C● Minimum bending radius for use in EnergyChains ® : 7,5 x cable diameter● Colour: Jet black (similar to RAL 9005)... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu355


DataPVC<strong>Chainflex</strong> ® -PVC Data cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 300/300 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Silver gray (similar to RAL 7001)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmB&RB&RBasic cablei8CRxxx.12-1 MAT9640001 (3 x (2 x 0,25))C 7,0BeckhoffBasic cableZK4000-2610-xxxx MAT9381004 (8 x (2 x 0,25))C 11,5BeckhoffBasic cableZK4510-0020-xxxx MAT9381001 (8 x (2 x 0,25))C 11,5BeckhoffBasic cableBECKHOFFZK4520-0020-xxxx MAT9381002 (6 x (2 x 0,25))C 9,5BeckhoffExtension cableZK4511-0020-xxxx MAT9381003 (8 x (2 x 0,25))C 11,5BeckhoffBasic cableZK4000-2210-xxxx MAT9383003 (4 x (2 x 0,25))C 8,0BeckhoffBasic cableZK4530-0010-xxxx MAT9383001 (4 x (2 x 0,25))C 8,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core356950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


DataPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 10 x cable diameterManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmBECKHOFFBeckhoffExtension cableZK4531-0020-xxxx MAT9383002 (4 x (2 x 0,25))C 8,0Danaher MotionBasic cableDANAHER MOTION84972 (5 m) MAT9320001 (4 x (2 x 0,25))C 8,084973 (10 m) MAT9320009 (4 x (2 x 0,25))C 8,084974 (15 m) MAT9320010 (4 x (2 x 0,25))C 8,084975 (20 m) MAT9320011 (4 x (2 x 0,25))C 8,087655 (25 m) MAT9320012 (4 x (2 x 0,25))C 8,090287 (5 m) MAT9320002 (8 x (2 x 0,25))C 11,591019 (10 m) MAT9320013 (8 x (2 x 0,25))C 11,591811 (15 m) MAT9320014 (8 x (2 x 0,25))C 11,591807 (20 m) MAT9320015 (8 x (2 x 0,25))C 11,592205 (25 m) MAT9320016 (8 x (2 x 0,25))C 11,5107915 (5 m) MAT9320004 (8 x (2 x 0,25))C 11,5107916 (10 m) MAT9320017 (8 x (2 x 0,25))C 11,5107917 (15 m) MAT9320018 (8 x (2 x 0,25))C 11,5107918 (20 m) MAT9320019 (8 x (2 x 0,25))C 11,5107919 (25 m) MAT9320020 (8 x (2 x 0,25))C 11,5Danaher MotionBasic cable85034 (5 m) MAT9320007 (6 x (2 x 0,25))C 9,585035 (10 m) MAT9320021 (6 x (2 x 0,25))C 9,585036 (15 m) MAT9320022 (6 x (2 x 0,25))C 9,585037 (20 m) MAT9320023 (6 x (2 x 0,25))C 9,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu357


DataPVC<strong>Chainflex</strong> ® -PVC Data cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 300/300 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Silver gray (similar to RAL 7001)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmDANAHER MOTIONDanaher MotionBasic cable85039 (5 m) MAT9320008 (6 x (2 x 0,25))C 9,585040 (10 m) MAT9320024 (6 x (2 x 0,25))C 9,585041 (15 m) MAT9320025 (6 x (2 x 0,25))C 9,585042 (20 m) MAT9320026 (6 x (2 x 0,25))C 9,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core358950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


DataPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu359


MeasuringPVC<strong>Chainflex</strong> ® -PVC Measuring system cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Silver gray (similar to RAL 7001)Manufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmB&RB&RBasic cablei8CExxx.12-1 MAT9670001 (5x(2x0,14)+2x0,5)C 9,0BAUMÜLLERBaumüllerSRS/SRM50 & SKS/SKM36Basic cable246658 (3 m) MAT9290001 (5x(2x0,14)+2x0,5)C 9,0243379 (4 m) MAT9290002 (5x(2x0,14)+2x0,5)C 9,0239540 (5 m) MAT9290003 (5x(2x0,14)+2x0,5)C 9,0242954 (6 m) MAT9290004 (5x(2x0,14)+2x0,5)C 9,0239541 (8 m) MAT9290005 (5x(2x0,14)+2x0,5)C 9,0239542 (10 m) MAT9290006 (5x(2x0,14)+2x0,5)C 9,0239543 (15 m) MAT9290007 (5x(2x0,14)+2x0,5)C 9,0239544 (20 m) MAT9290008 (5x(2x0,14)+2x0,5)C 9,0239545 (25 m) MAT9290009 (5x(2x0,14)+2x0,5)C 9,0239546 (30 m) MAT9290010 (5x(2x0,14)+2x0,5)C 9,0239547 (35 m) MAT9290011 (5x(2x0,14)+2x0,5)C 9,0240520 (40 m) MAT9290012 (5x(2x0,14)+2x0,5)C 9,0240521 (45 m) MAT9290013 (5x(2x0,14)+2x0,5)C 9,0240522 (50 m) MAT9290014 (5x(2x0,14)+2x0,5)C 9,0244033 (55 m) MAT9290015 (5x(2x0,14)+2x0,5)C 9,0245484 (60 m) MAT9290016 (5x(2x0,14)+2x0,5)C 9,0BaumüllerSRS/SRM50 & SKS/SKM36Extension cableBaumüllerBasic cable*MAT9292001 (5x(2x0,14)+2x0,5)C 9,0198962 (3 m) MAT9290020 (5x(2x0,14)+2x0,5)C 9,0198963 (5 m) MAT9290021 (5x(2x0,14)+2x0,5)C 9,0All <strong>cables</strong> available in the lengths you require.360Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 10 x cable diameterManufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mm198964 (8 m) MAT9290022 (5x(2x0,14)+2x0,5)C 9,0198965 (10 m) MAT9290023 (5x(2x0,14)+2x0,5)C 9,0198966 (15 m) MAT9290024 (5x(2x0,14)+2x0,5)C 9,0198967 (10 m) MAT9290025 (5x(2x0,14)+2x0,5)C 9,0198968 (25 m) MAT9290026 (5x(2x0,14)+2x0,5)C 9,0198969 (30 m) MAT9290027 (5x(2x0,14)+2x0,5)C 9,0225360 (35 m) MAT9290028 (5x(2x0,14)+2x0,5)C 9,0208829 (40 m) MAT9290029 (5x(2x0,14)+2x0,5)C 9,0BaumüllerExtension cableMAT9292020 (5x(2x0,14)+2x0,5)C 9,0BAUMÜLLERBaumüllerECN1313/EQN1325Basic cable393889 (2m) MAT9290030 (5x(2x0,14)+2x0,5)C 9,0369864 (3m) MAT9290031 (5x(2x0,14)+2x0,5)C 9,0394014 (5 m) MAT9290032 (5x(2x0,14)+2x0,5)C 9,0389807 (7 m) MAT9290033 (5x(2x0,14)+2x0,5)C 9,0393890 (8 m) MAT9290034 (5x(2x0,14)+2x0,5)C 9,0389808 (9m) MAT9290035 (5x(2x0,14)+2x0,5)C 9,0393891 (10 m) MAT9290036 (5x(2x0,14)+2x0,5)C 9,0393892 (15 m) MAT9290037 (5x(2x0,14)+2x0,5)C 9,0371494 (20 m) MAT9290038 (5x(2x0,14)+2x0,5)C 9,0393893 (25 m) MAT9290039 (5x(2x0,14)+2x0,5)C 9,0393894 (30 m) MAT9290040 (5x(2x0,14)+2x0,5)C 9,0380358 (35 m) MAT9290041 (5x(2x0,14)+2x0,5)C 9,0391216 (40 m) MAT9290042 (5x(2x0,14)+2x0,5)C 9,0382005 (45 m) MAT9290043 (5x(2x0,14)+2x0,5)C 9,0378022 (50 m) MAT9290044 (5x(2x0,14)+2x0,5)C 9,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu361


MeasuringPVC<strong>Chainflex</strong> ® -PVC Measuring system cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Silver gray (similar to RAL 7001)BAUMÜLLERManufacturerPart No.BaumüllerECN1313/EQN1325Extension cableigus ®Number of cores and conductor øPart No.nominal cross section [mm 2 ]mmMAT9292030 (5x(2x0,14)+2x0,5)C 9,0LENZE ELAU CONTROL TECHN. BERGER L.Berger LahrBasic cableVW3M8101Rxxx MAT94603001 (4x(2x0,34)+4x0,5)C 9,0Control TechniquesBasic cableSS B A H C XXX MAT9560100 (4x(2x0,34)+4x0,5)C 10,5SS B A H H XXX MAT9560101 (4x(2x0,34)+4x0,5)C 10,5SS B A H N XXX MAT9560104 (3x(2x0,14)C+ (4x0,14)+(2x0,5))C 10,5ELAUBasic cableE-FB-060 MAT9480001 (4x(2x0,25)+2x0,5)c 9,0E-FB-071 MAT9480002 (4x(2x0,25)+2x0,5)c 9,0ELAUBasic cableE-FB-080 MAT9480003 (4x(2x0,25)+2x0,5)c 9,0LenzeBasic cableEWLRxxxGM-T MAT9130021 (3x(2x0,14)C+2x(0,5)C)C 9,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core362950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 10 x cable diameterManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmLenzeLinking cableEWLRxxxZMST MAT9130022 (3x(2x0,14)C+2x(0,5)C)C 9,0LenzeTerminal box connection cable*EWLRxxxGX-T MAT9130023 (3x(2x0,14)C+2x(0,5)C)C 9,0LenzeBasic cableEWLExxxGM-T MAT9130026 (4x(2x0,25)+2x1,0)C 9,5LENZELenzeLinking cableEWLExxxZMST MAT9130027 (4x(2x0,25)+2x1,0)C 9,5LenzeTerminal box connection cable*EWLExxxGX-T MAT9130028 (4x(2x0,25)+(2x1,0))C 9,5LenzeBasic cable*EYF0020VxxxxA00G01 MAT9130080 3x(2x0,14)C+(3x0,14)C 9,5EYF0019VxxxxA00G02 MAT9130081 4x(2x0,14)C+(2x1,0)C 11,0EYF0022VxxxxA00G03 MAT9130082 3x(2x0,14)C+(4x0,14)C+2(2x0,5)C 11,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu363


MeasuringPVC<strong>Chainflex</strong> ® -PVC Measuring system cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Silver gray (similar to RAL 7001)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmLenzeBasic cableEYF0021AxxxxF03S03 MAT9130086 3x(2x0,14)C+(4x0,14)C+2(2x0,5)C 11,0EYF0018AxxxxF02S03 MAT9130088 4x(2x0,14)C+(2x1,0)C 11,0EYF0020AxxxxF01S05 MAT9130090 3x(2x0,14)C+(3x0,14)C 9,5LenzeBasic cableLENZEEYF0018AxxxxF02W02 MAT9130087 4x(2x0,14)C+(2x1,0)C 11,0EYF0020AxxxxF01S04 MAT9130089 3x(2x0,14)C+(3x0,14)C 9,5LenzeBasic cable*EYF0018AxxxxA00W02 MAT9130091 4x(2x0,14)C+(2x1,0)C 11,0EYF0020AxxxxA00S04 MAT9130092 3x(2x0,14)C+(3x0,14)C 9,5LenzeBasic cable*EYF0020AxxxxA00S05 MAT9130093 3x(2x0,14)C+(3x0,14)C 9,5EYF0021AxxxxA00S03 MAT9130094 3x(2x0,14)C+(4x0,14)C+2(2x0,5)C 11,0EYF0018AxxxxA00S03 MAT9130095 4x(2x0,14)C+(2x1,0)C 11,0LenzeLinking cableEYF0020VxxxxF01G01 MAT9130083 3x(2x0,14)C+(3x0,14)C 9,5EYF0019VxxxxF02G02 MAT9130084 4x(2x0,14)C+(2x1,0)C 11,0EYF0022VxxxxF03G03 MAT9130085 3x(2x0,14)C+(4x0,14)C+2(2x0,5)C 11,0All <strong>cables</strong> available in the lengths you require.364Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 10 x cable diameterManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmLenzeConnecting cableLENZEEYD0017AxxxxW01S01 MAT9130100 3x(2x0,14)C+(3x0,14)C 9,5LenzeConnecting cableEYD0017AxxxxW01S02 MAT9130101 3x(2x0,14)C+(3x0,14)C 9,5LenzeConnecting cableEYD0017AxxxxW03S01 MAT9130102 3x(2x0,14)C+(3x0,14)C 9,5LenzeConnecting cableEYD0017AxxxxW03S02 MAT9130103 3x(2x0,14)C+(3x0,14)C 9,5NUMBasic cableNUMAGOFRU029Mxxx MAT9284001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0NUMExtension cableAGOFRU029Mxxx MAT9284011 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0NUMBasic cable*AGOFRU030Mxxx MAT9289001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu365


MeasuringPVC<strong>Chainflex</strong> ® -PVC Measuring system cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Silver gray (similar to RAL 7001)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmNUMNUMExtension cableAGOFRU030Mxxx MAT9289011 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0RexrothBasic cableREXROTHIKS0230 MAT9110008 (2x(2x0,25)+2x0,5)C 7,0IKS0232 MAT9110009 (2x(2x0,25)+2x0,5)C 7,0IKS0301 MAT9110015 (4x(2x0,25)+2x1,0)C 9,5IKS0315 MAT9110020 (4x(2x0,25)+2x1,0)C 9,5IKS0374 MAT9110011 (4x(2x0,25)+2x1,0)C 9,5IKS4001 MAT9110026 (4x(2x0,14)+4x1,0+(4x0,14)C)C 9,0IKS4002 MAT9110010 (3x0,25+3x(2x0,25)C+2x1,0)C 9,0IKS4020 MAT9110006 (4x(2x0,14)+4x1,0+(4x0,14)C)C 9,0IKS4038 MAT9110027 (4x(2x0,14)+4x1,0+(4x0,14)C)C 9,0IKS4041 MAT9110028 (3x0,25+3x(2x0,25)C+2x1,0)C 9,0IKS4042 MAT9110017 (4x(2x0,25)+2x0,5)C 9,0IKS4066 MAT9110025 (4x(2x0,25)+2x0,5)C 9,0IKS4103 MAT9110001 (4x(2x0,25)+2x0,5)C 9,0IKS4142 MAT9110007 (4x(2x0,14)+4x1,0+(4x0,14)C)C 9,0IKS4314 MAT9110004 (4x(2x0,25)+2x1,0)C 9,0IKS4374 MAT9110002 (4x(2x0,25)+2x0,5)C 9,0IKS4375 MAT9110003 (4x(2x0,25)+2x0,5)C 9,0IKS4384 MAT9110005 (3x0,25+3x(2x0,25)C+2x1,0)C 9,0IKS4389 MAT9110033 (3x0,25+3x(2x0,25)C+2x1,0)C 9,0RexrothBasic cableRKG0014 MAT9110030 (3x0,25+3x(2x0,25)C+2x1,0)C 9,0RKG0020 MAT9110034 (4x(2x0,25)+2x0,5)C 9,5RKG0026 MAT9110029 (3x0,25+3x(2x0,25)C+2x1,0)C 9,0RKG0028 MAT9110031 (3x0,25+3x(2x0,25)C+2x1,0)C 9,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core366950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 10 x cable diameterManufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmRKG4200 MAT9110013 (4x(2x0,25)+2x0,5)C 9,5REXROTHRexrothConnecting cablewith adapter plugsIKS0303 MAT9110019 (4x(2x0,25)+2x1,0)C 9,5IKS4065 MAT9111001 (4x(2x0,25)+2x0,5)C 9,0IKS4151 MAT9111002 (4x(2x0,25)+2x0,5)C 9,0IKS4153 MAT9111003 (4x(2x0,25)+2x0,5)C 9,0IKS4376 MAT9111004 (4x(2x0,25)+2x0,5)C 9,0IKS4322 MAT9111005 (4x(2x0,25)+2x0,5)C 9,0RexrothConnecting cablewith adapter plugsRKG4201 MAT9111006 (4x(2x0,25)+2x0,5)C 9,5SEWConnection cableSEW199 319 4 MAT9500001 (4x(2x0,25)+2x0,5)C 9,51332 743 7 MAT9500002 (4x(2x0,25)+2x0,5)C 9,51332 455 1 MAT9500003 (4x(2x0,25)+2x0,5)C 9,5198 930 8 MAT9500004 (4x(2x0,25)+2x0,5)C 9,5SEWExtension cable199 541 3 MAT9501001 (4x(2x0,25)+2x0,5)C 9,5199 540 5 MAT9501002 (4x(2x0,25)+2x0,5)C 9,50593 968 2 MAT9501003 (4x(2x0,25)+2x0,5)C 9,5SIEMENSSiemensBasic cable6FX8002-2AD00 MAT9170001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu367


MeasuringPVC<strong>Chainflex</strong> ® -PVC Measuring system cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Silver gray (similar to RAL 7001)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømm6FX8002-2CA11 MAT9170002 (4x(2x0,34)+4x0,5)C 9,06FX8002-2CA15 MAT9170003 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0SiemensBasic cable6FX8002-2CA31 MAT9170004 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 9,5SiemensBasic cableSIEMENS6FX8002-2CA51 MAT9170005 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,06FX8002-2CA71 MAT9170006 (4x(2x0,34)+4x0,5)C 9,06FX8002-2CB51 MAT9170008 (4x(2x0,34)+4x0,5)C 9,06FX8002-2CC11 MAT9170009 (4x(2x0,34)+4x0,5)C 9,06FX8002-2CD01 MAT9170010 (4x(2x0,34)+4x0,5)C 9,0SiemensBasic cable6FX8002-2CF01 MAT9170021 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,06FX8002-2CF02 MAT9170011 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,06FX8002-2CG00 MAT9170012 (4x(2x0,34)+4x0,5)C 9,0SiemensBasic cable6FX8002-2CH00 MAT9170013 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0SiemensBasic cable6FX8002-2CK00 MAT9170014 (3x(2x0,14)C+2x(0,5)C)C 9,06FX8002-2CL00 MAT9170015 (3x(2x0,14)C+2x(0,5)C)C 9,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core368950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 10 x cable diameterManufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmSiemensBasic cable6FX8002-2EQ00 MAT9170016 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 9,5SiemensBasic cable6FX8002-2EQ10 MAT9170017 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 9,5SIEMENSSiemensBasic cable*6FX8002-2AH00 MAT9170018 (4x(2x0,34)+4x0,5)C 9,0SiemensExtension cable6FX8002-2AD04 MAT9171001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,06FX8002-2CB54 MAT9171002 (4x(2x0,34)+4x0,5)C 9,06FX8002-2CA54 MAT9171003 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,06FX8002-2CA34 MAT9171004 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 9,56FX8002-2CC14 MAT9171009 (4x(2x0,34)+4x0,5)C 9,06FX8002-2CF04 MAT9171011 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,06FX8002-2EQ14 MAT9171017 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 9,56FX8002-2AH04 MAT9171018 (4x(2x0,34)+4x0,5)C 9,0STÖBERStöberiMDS5000Basic cableResolver MAT9431005 (3x(2x0,25)C)C 11,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu369


MeasuringPVC<strong>Chainflex</strong> ® -PVC Measuring system cable● Class 5.3.2● Oil-resistant● Shielded● Flame-retardant● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% optical● Colour: Silver gray (similar to RAL 7001)Manufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmSTÖBERStöberiMDS5000Basic cableEncoder MAT9431004 (4x(2x0,25)+(2x0,5))C 9,0StöberiSDS4000Basic cableResolver MAT9431003 (4x(2x0,25)+(2x0,5))C 9,0StöberiSDS4000Basic cableEncoder ED/EK MAT9431001 (4x(2x0,34)+4x0,5)C 9,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core370950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringPVC● Temperature range (moved):-5 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu371


DataPUR<strong>Chainflex</strong> ® -PUR Data cable● Class 6.3.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 300/300 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmBeckhoffBasic cableZK4000-2610-xxxx MAT9382004 (8 x (2 x 0,25))C 11,0BeckhoffBasic cableZK4510-0020-xxxx MAT9382001 (8 x (2 x 0,25))C 11,0BeckhoffBasic cableBECKHOFFZK4520-0020-xxxx MAT9382002 (6 x (2 x 0,25))C 10,0BeckhoffExtension cableZK4511-0020-xxxx MAT9382003 (8 x (2 x 0,25))C 11,0BeckhoffBasic cableZK4000-2210-xxxx MAT9384003 (4 x (2 x 0,25))C 9,0BeckhoffBasic cableZK4530-0010-xxxx MAT9384001 (4 x (2 x 0,25))C 9,0BeckhoffExtension cableZK4531-0020-xxxx MAT9384002 (4 x (2 x 0,25))C 9,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core372950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


DataPUR● Flame-retardant● Temperature range (moved): -35 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Anthracite gray (similar to RAL 7016)... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu373


MeasuringPUR<strong>Chainflex</strong> ® -PUR Measuring system cable● Class 6.3.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmFanucBasic cableLX660-4077-T296 MAT9300296 (5x0,5+1x2x0,25)C 7,5FanucBasic cableFANUCLX660-4077-T297 MAT9300297 (5x0,5+1x2x0,25)C 7,5FanucBasic cableLX660-4077-T302 MAT9300302 (6x0,5+5x2x0,25)C 10,0FanucBasic cableLX660-4077-T303 MAT9300303 (6x0,5+5x2x0,25)C 10,0FanucBasic cableLX660-4077-T319 MAT9300319 (6x0,5+5x2x0,25)C 10,0HeidenhainConnecting cableHEIDENHAIN332 115-xx MAT94901001 (4x(2x0,14)+(4x0,14)C+4x0,5)C 12,0HeidenhainConnecting cable360 472-xx MAT94901002 (4x(2x0,14)+(4x0,14)C+4x0,5)C 12,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core374950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringPUR● Flame-retardant● Temperature range (moved): -20 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Yellow green (similar to RAL 6018)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmHeidenhainConnecting cable310 197-xx MAT94902001 (3x(2x0,14)C+(2x0,5)C)C 12,0HeidenhainConnecting cable324 544-xx MAT94902002 (4x(2x0,14)+(4x0,14)C+4x0,5)C 12,0310 199-xx MAT94902003 (4x(2x0,14)+4x0,5)C 10,0HeidenhainConnecting cableHEIDENHAIN309 738-xx MAT94903001 (4x(2x0,14)+4x0,5)C 10,0HeidenhainConnecting cable354 411-xx MAT94904001 (4x(2x0,14)+(4x0,14)C+4x0,5)C 12,0355 398-xx MAT94904002 (4x(2x0,14)+(4x0,14)C+4x0,5)C 12,0HeidenhainConnecting cable298 399-xx MAT94905001 (4x(2x0,14)+4x0,5)C 10,0HeidenhainConnecting cable309 774-xx MAT94906001 (4x(2x0,14)+4x0,5)C 10,0298 400-xx MAT94906002 (4x(2x0,14)+4x0,5)C 10,0323 897-xx MAT94907004 (4x(2x0,14)+ (4x0,14)C+4x0,5)C 12,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu375


MeasuringPUR<strong>Chainflex</strong> ® -PUR Measuring system cable● Class 6.3.3● Oil-resistant and coolant-resistant● Shielded● Notch-resistant, hydrolysis-resistant andmicrobe-resistant● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmHeidenhainConnecting cable309 777-xx MAT94907001 (4x(2x0,14)+4x0,5)C 10,0309 778-xx MAT94907002 (4x(2x0,14)+(4x0,14)C+4x0,5)C 12,0HEIDENHAINHeidenhainConnecting cable310 193-xx MAT94907003 (3x(2x0,14)C+(2x0,5)C)C 12,0HeidenhainConnecting cable335 077-xx MAT94908001 (4x(2x0,14)+4x0,5)C 10,0HeidenhainConnecting cable298 402-xx MAT94909001 (4x(2x0,14)+4x0,5)C 10,0SIEMENSSiemensBasic cable6FX8002-2DC10 MAT9070030 (2x(2x0,15)+(2x0,38))C 7,56FX8002-2DC20 MAT9070031 (2x(2x0,15)+(2x0,38))C 7,56FX8002-1DC00 MAT9070032 (2x(2x0,15)+(2x0,38))C 7,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core376950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringPUR● Flame-retardant● Temperature range (moved): -20 °C to + 80°C● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Yellow green (similar to RAL 6018)... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu377


DataTPE<strong>Chainflex</strong> ® -TPE Data cable● Class 6.4.4● Oil-resistant● Shielded● Temperature range (moved):-35 °C to + 100°C● Nominal voltage: 300/300 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmB&RB&RBasic cablei8CRxxx.12-1 MAT9630001 (3 x (2 x 0,25))C 8,0Danaher MotionBasic cableDANAHER MOTION84972 (5 m) MAT9330001 (4 x (2 x 0,25))C 8,084973 (10 m) MAT9330009 (4 x (2 x 0,25))C 8,084974 (15 m) MAT9330010 (4 x (2 x 0,25))C 8,084975 (20 m) MAT9330011 (4 x (2 x 0,25))C 8,087655 (25 m) MAT9330012 (4 x (2 x 0,25))C 8,090287 (5 m) MAT9330002 (8 x (2 x 0,25))C 11,591019 (10 m) MAT9330013 (8 x (2 x 0,25))C 11,591811 (15 m) MAT9330014 (8 x (2 x 0,25))C 11,591807 (20 m) MAT9330015 (8 x (2 x 0,25))C 11,592205 (25 m) MAT9330016 (8 x (2 x 0,25))C 11,5107915 (5 m) MAT9330004 (8 x (2 x 0,25))C 11,5107916 (10 m) MAT9330017 (8 x (2 x 0,25))C 11,5107917 (15 m) MAT9330018 (8 x (2 x 0,25))C 11,5107918 (20 m) MAT9330019 (8 x (2 x 0,25))C 11,5107919 (25 m) MAT9330020 (8 x (2 x 0,25))C 11,5Danaher MotionBasic cable85034 (5 m) MAT9330007 (6 x (2 x 0,25))C 9,585035 (10 m) MAT9330021 (6 x (2 x 0,25))C 9,585036 (15 m) MAT9330022 (6 x (2 x 0,25))C 9,585037 (20 m) MAT9330023 (6 x (2 x 0,25))C 9,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core378950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


DataTPE● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Steel blue (similar to RAL 5011)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmDANAHER MOTIONDanaher MotionBasic cable85039 (5 m) MAT9330008 (6 x (2 x 0,25))C 9,585040 (10 m) MAT9330024 (6 x (2 x 0,25))C 9,585041 (15 m) MAT9330025 (6 x (2 x 0,25))C 9,585042 (20 m) MAT9330026 (6 x (2 x 0,25))C 9,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu379


MeasuringTPE<strong>Chainflex</strong> ® -TPE Measuring system cable● Class 6.4.4● Oil-resistant● Shielded● Temperature range (moved):-35 °C to + 100°C● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmB&RB&RBasic cablei8CExxx.12-1 MAT9660001 (5x(2x0,14)+2x0,5)C 9,5BAUMÜLLERBaumüllerSRS/SRM50 & SKS/SKM36Basic cable246658 (3 m) MAT9291001 (5x(2x0,14)+2x0,5)C 9,5243379 (4 m) MAT9291002 (5x(2x0,14)+2x0,5)C 9,5239540 (5 m) MAT9291003 (5x(2x0,14)+2x0,5)C 9,5242954 (6 m) MAT9291004 (5x(2x0,14)+2x0,5)C 9,5239541 (8 m) MAT9291005 (5x(2x0,14)+2x0,5)C 9,5239542 (10 m) MAT9291006 (5x(2x0,14)+2x0,5)C 9,5239543 (15 m) MAT9291007 (5x(2x0,14)+2x0,5)C 9,5239544 (20 m) MAT9291008 (5x(2x0,14)+2x0,5)C 9,5239545 (25 m) MAT9291009 (5x(2x0,14)+2x0,5)C 9,5239546 (30 m) MAT9291010 (5x(2x0,14)+2x0,5)C 9,5239547 (35 m) MAT9291011 (5x(2x0,14)+2x0,5)C 9,5240520 (40 m) MAT9291012 (5x(2x0,14)+2x0,5)C 9,5240521 (45 m) MAT9291013 (5x(2x0,14)+2x0,5)C 9,5240522 (50 m) MAT9291014 (5x(2x0,14)+2x0,5)C 9,5244033 (55 m) MAT9291015 (5x(2x0,14)+2x0,5)C 9,5245484 (60 m) MAT9291016 (5x(2x0,14)+2x0,5)C 9,5BaumüllerSRS/SRM50 & SKS/SKM36Extension cableBaumüllerBasic cable*MAT9293001 (5x(2x0,14)+2x0,5)C 9,5198962 (3 m) MAT9291020 (5x(2x0,14)+2x0,5)C 9,5198963 (5 m) MAT9291021 (5x(2x0,14)+2x0,5)C 9,5All <strong>cables</strong> available in the lengths you require.380Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringTPE● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Yellow green (similar to RAL 6018)Manufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mm198964 (8 m) MAT9291022 (5x(2x0,14)+2x0,5)C 9,5198965 (10 m) MAT9291023 (5x(2x0,14)+2x0,5)C 9,5198966 (15 m) MAT9291024 (5x(2x0,14)+2x0,5)C 9,5198967 (10 m) MAT9291025 (5x(2x0,14)+2x0,5)C 9,5198968 (25 m) MAT9291026 (5x(2x0,14)+2x0,5)C 9,5198969 (30 m) MAT9291027 (5x(2x0,14)+2x0,5)C 9,5225360 (35 m) MAT9291028 (5x(2x0,14)+2x0,5)C 9,5208829 (40 m) MAT9291029 (5x(2x0,14)+2x0,5)C 9,5BaumüllerExtension cableMAT9293020 (5x(2x0,14)+2x0,5)C 9,5BAUMÜLLERBaumüllerECN1313/EQN1325Basic cable393889 (2 m) MAT9291030 (5x(2x0,14)+2x0,5)C 9,5369864 (3 m) MAT9291031 (5x(2x0,14)+2x0,5)C 9,5394014 (5 m) MAT9291032 (5x(2x0,14)+2x0,5)C 9,5389807 (7 m) MAT9291033 (5x(2x0,14)+2x0,5)C 9,5393890 (8 m) MAT9291034 (5x(2x0,14)+2x0,5)C 9,5389808 (9 m) MAT9291035 (5x(2x0,14)+2x0,5)C 9,5393891 (10 m) MAT9291036 (5x(2x0,14)+2x0,5)C 9,5393892 (15 m) MAT9291037 (5x(2x0,14)+2x0,5)C 9,5371494 (20 m) MAT9291038 (5x(2x0,14)+2x0,5)C 9,5393893 (25 m) MAT9291039 (5x(2x0,14)+2x0,5)C 9,5393894 (30 m) MAT9291040 (5x(2x0,14)+2x0,5)C 9,5380358 (35 m) MAT9291041 (5x(2x0,14)+2x0,5)C 9,5391216 (40 m) MAT9291042 (5x(2x0,14)+2x0,5)C 9,5382005 (45 m) MAT9291043 (5x(2x0,14)+2x0,5)C 9,5378022 (50 m) MAT9291044 (5x(2x0,14)+2x0,5)C 9,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu381


MeasuringTPE<strong>Chainflex</strong> ® -TPE Measuring system cable● Class 6.4.4● Oil-resistant● Shielded● Temperature range (moved):-35 °C to + 100°C● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalBAUMÜLLERManufacturerPart No.BaumüllerECN1313/EQN1325Extension cableigus ®Number of cores and conductor øPart No.nominal cross section [mm 2 ]mmMAT9293030 (5x(2x0,14)+2x0,5)C 9,5BERGER L.CONTROL TECHN.Berger LahrBasic cableVW3M8101Rxxx MAT94600001 (4x(2x0,34)+4x0,5)C 10,5Control TechniquesBasic cableSS B A H C XXX MAT9540100 (4x(2x0,34)+4x0,5)C 10,5SS B A H H XXX MAT9540101 (4x(2x0,34)+4x0,5)C 10,5SS B A H N XXX MAT9540104 (3x(2x0,14)C+ (4x0,14)+(2x0,5))C 10,5ELAUBasic cableFAGOR ELAUE-FB-060 MAT9480101 (4x(2x0,25)+2x0,5)C 9,5E-FB-071 MAT9480102 (4x(2x0,25)+2x0,5)C 9,5ELAUBasic cableE-FB-080 MAT9480103 (4x(2x0,25)+2x0,5)C 9,5FagorExtension cableiXC-C2-D MAT9520001 (4x(2x0,14)+4x0,5)C 9,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core382950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringTPE● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Yellow green (similar to RAL 6018)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmFagorExtension cableiXC-C4-D MAT9520010 (4x(2x0,14)+4x0,5)C 9,0FagorExtension cableFAGORiXC-C2-H MAT9520020 (4x(2x0,14)+4x0,5)C 9,0FagorExtension cableiXC-C8-F-D MAT9520030 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 12,0FagorExtension cableiXC-C8-F-C9 MAT9520040 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 12,0FagorExtension cableiXC-C8-FN MAT9520050 (4x(2x0,14)+4x0,5)C 9,0FagorExtension cableiXC-C2-FN2 MAT9520060 (4x(2x0,14)+4x0,5)C 9,0FANUCFanucBasic cableLX660-4077-T296 MAT9310296 (5x0,5+(2x0,25))C 8,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu383


MeasuringTPE<strong>Chainflex</strong> ® -TPE Measuring system cable● Class 6.4.4● Oil-resistant● Shielded● Temperature range (moved):-35 °C to + 100°C● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmFanucBasic cableFANUCLX660-4077-T297 MAT9310297 (5x0,5+(2x0,25))C 8,5FanucBasic cableLX660-4077-T302 MAT9310302 (3x(2x0,5+2x0,25)+(4x0,25))C 12,5FanucBasic cableLX660-4077-T303 MAT9310303 (3x(2x0,5+2x0,25)+(4x0,25))C 12,5FanucBasic cableLX660-4077-T319 MAT9310319 (3x(2x0,5+2x0,25)+(4x0,25))C 12,5HeidenhainConnecting cable332 115 -xx MAT93901001 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 12,0HEIDENHAINHeidenhainConnecting cable360 472-xx MAT93901002 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 12,0HeidenhainConnecting cable310 197-xx MAT93902001 (3x(2x0,14)C+(2x0,5)C)C 12,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core384950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringTPE● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Yellow green (similar to RAL 6018)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmHeidenhainConnecting cable324 544-xx MAT93902002 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 12,0310 199-xx MAT93902003 (4x(2x0,14)+4x0,5)C 9,0HeidenhainConnecting cable309 738-xx MAT93903001 (4x(2x0,14)+4x0,5)C 9,0HeidenhainConnecting cableHEIDENHAIN354 411-xx MAT93904001 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 12,0355 398-xx MAT93904002 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 12,0HeidenhainConnecting cable298 399-xx MAT93905001 (4x(2x0,14)+4x0,5)C 9,0HeidenhainConnecting cable309 774-xx MAT93906001 (4x(2x0,14)+4x0,5)C 9,0298 400-xx MAT93906002 (4x(2x0,14)+4x0,5)C 9,0323 897-xx MAT93907004 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 12,0HeidenhainConnecting cable309 777-xx MAT93907001 (4x(2x0,14)+4x0,5)C 9,0309 778-xx MAT93907002 (2x(2x2x0,14)+(4x0,14)C+(4x0,5))C 12,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu385


MeasuringTPE<strong>Chainflex</strong> ® -TPE Measuring system cable● Class 6.4.4● Oil-resistant● Shielded● Temperature range (moved):-35 °C to + 100°C● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmHeidenhainConnecting cableHEIDENHAIN310 193-xx MAT93907003 (3x(2x0,14)C+(2x0,5)C)C 12,5HeidenhainConnecting cable335 077-xx MAT93908001 (4x(2x0,14)+4x0,5)C 10,0HeidenhainConnecting cable298 402-xx MAT93909001 (4x(2x0,14)+4x0,5)C 9,0LenzeBasic cableEWLRxxxGM-T MAT9120021 (3x(2x0,14)C+(2x0,5)C)C 12,5LenzeLinking cableLENZEEWLRxxxZMST MAT9120022 (3x(2x0,14)C+(2x0,5)C)C 12,5LenzeTerminal box connection cable*EWLRxxxGX-T MAT9120023 (3x(2x0,14)C+(2x0,5)C)C 12,5LenzeBasic cableEWLExxxGM-T MAT9120026 (4x(2x0,25)+2x1,0)C 9,5All <strong>cables</strong> available in the lengths you require.386Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringTPE● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Yellow green (similar to RAL 6018)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmLenzeLinking cableEWLExxxZMST MAT9120027 (4x(2x0,25)+2x1,0)C 9,5LenzeTerminal box connection cable*EWLExxxGX-T MAT9120028 (4x(2x0,25)+(2x1,0))C 9,5LenzeBasic cable*LENZEEYF0020VxxxxA00G01 MAT9120080 3x(2x0,14)C+(3x0,14)C 9,5EYF0019VxxxxA00G02 MAT9120081 4x(2x0,14)C+(2x1,0)C 11,0EYF0022VxxxxA00G03 MAT9120082 3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C 12,0LenzeBasic cableEYF0021AxxxxF03S03 MAT9120086 3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C 12,0EYF0018AxxxxF02S03 MAT9120088 4x(2x0,14)C+(2x1,0)C 11,0EYF0020AxxxxF01S05 MAT9120090 3x(2x0,14)C+(3x0,14)C 9,5LenzeBasic cableEYF0018AxxxxF02W02 MAT9120087 4x(2x0,14)C+(2x1,0)C 11,0EYF0020AxxxxF01S04 MAT9120089 3x(2x0,14)C+(3x0,14)C 9,5LenzeBasic cable*EYF0018AxxxxA00W02 MAT9120091 4x(2x0,14)C+(2x1,0)C 11,0EYF0020AxxxxA00S04 MAT9120092 3x(2x0,14)C+(3x0,14)C 9,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu387


MeasuringTPE<strong>Chainflex</strong> ® -TPE Measuring system cable● Class 6.4.4● Oil-resistant● Shielded● Temperature range (moved):-35 °C to + 100°C● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmLenzeBasic cable*EYF0020AxxxxA00S05 MAT9120093 3x(2x0,14)C+(3x0,14)C 9,5EYF0021AxxxxA00S03 MAT9120094 3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C 12,0EYF0018AxxxxA00S03 MAT9120095 4x(2x0,14)C+(2x1,0)C 11,0LenzeLinking cableEYF0020VxxxxF01G01 MAT9120083 3x(2x0,14)C+(3x0,14)C 9,5EYF0019VxxxxF02G02 MAT9120084 4x(2x0,14)C+(2x1,0)C 11,0EYF0022VxxxxF03G03 MAT9120085 3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C 12,0LENZELenzeConnecting cableEYD0017AxxxxW01S01 MAT9120100 3x(2x0,14)C+(3x0,14)C 9,5LenzeConnecting cableEYD0017AxxxxW01S02 MAT9120101 3x(2x0,14)C+(3x0,14)C 9,5LenzeConnecting cableEYD0017AxxxxW03S01 MAT9120102 3x(2x0,14)C+(3x0,14)C 9,5LenzeConnecting cableEYD0017AxxxxW03S02 MAT9120103 3x(2x0,14)C+(3x0,14)C 9,5All <strong>cables</strong> available in the lengths you require.388Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringTPE● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Yellow green (similar to RAL 6018)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmNUMBasic cableNUMAGOFRU029Mxxx MAT9286001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5NUMExtension cableAGOFRU029Mxxx MAT9286011 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5NUMBasic cable*AGOFRU030Mxxx MAT9289004 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5NUMExtension cableAGOFRU030Mxxx MAT9289014 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5RexrothBasic cableREXROTHIKS0230 MAT9100008 (2x(2x0,25)+2x0,5)C 7,0IKS0251 MAT9100014 (8) (12x0,5)C 11,5IKS0253 MAT9100023 (8) (12x0,5)C 11,5IKS0259 MAT9100032 (8) (12x0,5)C 11,5IKS0262 MAT9100016 (8) (12x0,5)C 11,5IKS0301 MAT9100015 (4x(2x0,25)+2x1,0)C 9,5IKS0315 MAT9100020 (4x(2x0,25)+2x1,0)C 9,5IKS0374 MAT9100011 (4x(2x0,25)+2x1,0)C 9,5IKS4001 MAT9100026 (4x(2x0,14)+(4x0,14)C+4x1,0)C 9,0IKS4002 MAT9100010 (3x(2x0,25)C+(3x0,25)+2x1,0)C 9,0IKS4020 MAT9100006 (4x(2x0,14)+(4x0,14)C+4x1,0)C 9,0IKS4038 MAT9100027 (4x(2x0,14)+(4x0,14)C+4x1,0)C 9,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.(8) ohne DESINAG = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu389


MeasuringTPE<strong>Chainflex</strong> ® -TPE Measuring system cable● Class 6.4.4● Oil-resistant● Shielded● Temperature range (moved):-35 °C to + 100°C● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmIKS4041 MAT9100028 (3x(2x0,25)C+(3x0,25)+2x1,0)C 9,0IKS4042 MAT9100017 (4x(2x0,25)+2x0,5)C 9,0IKS4066 MAT9100025 (4x(2x0,25)+2x0,5)C 9,0IKS4103 MAT9100001 (4x(2x0,25)+2x0,5)C 9,5IKS4142 MAT9100007 (4x(2x0,14)+(4x0,14)C+4x1,0)C 9,0IKS4314 MAT9100004 (4x(2x0,25)+2x1,0)C 9,5IKS4374 MAT9100002 (4x(2x0,25)+2x0,5)C 9,5IKS4375 MAT9100003 (4x(2x0,25)+2x0,5)C 9,5IKS4384 MAT9100005 (3x(2x0,25)C+(3x0,25)+2x1,0)C 9,0IKS4389 MAT9100033 (3x(2x0,25)C+(3x0,25)+2x1,0)C 9,0RexrothBasic cableREXROTHRKG0014 MAT9100030 (3x(2x0,25)C+(3x0,25)+2x1,0)C 9,0RKG0020 MAT9100034 (4x(2x0,25)+2x0,5)C 9,5RKG0026 MAT9100029 (3x(2x0,25)C+(3x0,25)+2x1,0)C 9,0RKG0028 MAT9100031 (3x(2x0,25)C+(3x0,25)+2x1,0)C 9,0RKG4200 MAT9100013 (4x(2x0,25)+2x0,5)C 9,5RexrothConnecting cablewith adapter plugsIKS0232 MAT9100009 (2x(2x0,25)+2x0,5)C 7,0IKS0255 MAT9100018 (8) (12x0,5)C 11,5IKS0303 MAT9100019 (4x(2x0,25)+2x1,0)C 9,5IKS4065 MAT9101001 (4x(2x0,25)+2x0,5)C 9,5IKS4151 MAT9101002 (4x(2x0,25)+2x0,5)C 9,5IKS4153 MAT9101003 (4x(2x0,25)+2x0,5)C 9,5IKS4322 MAT9101005 (4x(2x0,25)+2x0,5)C 9,5IKS4376 MAT9101004 (4x(2x0,25)+2x0,5)C 9,5RexrothConnecting cablewith adapter plugsRKG4201 MAT9101006 (4x(2x0,25)+2x0,5)C 9,5All <strong>cables</strong> available in the lengths you require.390Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.(8) ohne DESINAG = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringTPE● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Yellow green (similar to RAL 6018)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmSEWConnection cableSEW199 319 4 MAT9510001 (4x(2x0,25)+(2x0,5))C 9,01332 743 7 MAT9510002 (4x(2x0,25)+(2x0,5))C 9,01332 455 1 MAT9510003 (4x(2x0,25)+(2x0,5))C 9,0198 930 8 MAT9510004 (4x(2x0,25)+(2x0,5))C 9,0SEWExtension cable199 541 3 MAT9511001 (4x(2x0,25)+(2x0,5))C 9,0199 540 5 MAT9511002 (4x(2x0,25)+(2x0,5))C 9,00593 968 2 MAT9511003 (4x(2x0,25)+(2x0,5))C 9,0SiemensBasic cableSIEMENS6FX8002-2AD00 MAT9070001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,56FX8002-2CA11 MAT9070002 (4x(2x0,34)+4x0,5)C 9,56FX8002-2CA15 MAT9070003 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5SiemensBasic cable6FX8002-2CA31 MAT9070004 (3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 11,5SiemensBasic cable6FX8002-2CA51 MAT9070005 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,56FX8002-2CA71 MAT9070006 (4x(2x0,34)+4x0,5)C 9,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu391


MeasuringTPE<strong>Chainflex</strong> ® -TPE Measuring system cable● Class 6.4.4● Oil-resistant● Shielded● Temperature range (moved):-35 °C to + 100°C● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmSiemensBasic cable6FX8002-2CB31 MAT9070007 (12x0,25)C 9,0SiemensBasic cableSIEMENS6FX8002-2CB51 MAT9070008 (4x(2x0,34)+4x0,5)C 9,56FX8002-2CC11 MAT9070009 (4x(2x0,34)+4x0,5)C 9,56FX8002-2CD01 MAT9070010 (4x(2x0,34)+4x0,5)C 9,5SiemensBasic cable6FX8002-2CF01 MAT9070021 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,56FX8002-2CF02 MAT9070011 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,56FX8002-2CG00 MAT9070012 (4x(2x0,34)+4x0,5)C 9,56FX8002-2CH00 MAT9070013 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5SiemensBasic cable6FX8002-2CK00 MAT9070014 (3x(2x0,14)C+2x(0,5)C)C 10,5SiemensBasic cable6FX8002-2CL00 MAT9070015 (3x(2x0,14)C+2x(0,5)C)C 10,5SiemensBasic cable6FX8002-2EQ00 MAT9070016 (3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 11,56FX8002-2EQ10 MAT9070017 (3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 11,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core392950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringTPE● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Yellow green (similar to RAL 6018)Manufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmSiemensBasic cable*6FX8002-2AH00 MAT9070018 (4x(2x0,34)+4x0,5)C 9,5SiemensExtension cableSIEMENS6FX8002-2AD04 MAT9071001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,56FX8002-2CB54 MAT9071002 (4x(2x0,34)+4x0,5)C 9,56FX8002-2CA54 MAT9071003 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,56FX8002-2CA34 MAT9071004 (3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 11,5SiemensExtension cable6FX8002-2CB34 MAT9071007 (12x0,25)C 9,0SiemensExtension cable6FX8002-2CC14 MAT9071009 (4x(2x0,34)+4x0,5)C 9,56FX8002-2CF04 MAT9071011 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,56FX8002-2EQ14 MAT9071017 (3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 11,56FX8002-2AH04 MAT9071018 (4x(2x0,34)+4x0,5)C 9,5STÖBERStöberiMDS5000Basic cableResolver MAT9421005 (3x(2x0,25))C 8,5StöberiMDS5000Basic cableEncoder MAT9421004 (4x(2x0,25)+2x0,5)C 9,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu393


MeasuringTPE<strong>Chainflex</strong> ® -TPE Measuring system cable● Class 6.4.4● Oil-resistant● Shielded● Temperature range (moved):-35 °C to + 100°C● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerigus ®Number of cores and conductorøPart No.Part No.nominal cross section [mm 2 ]mmSTÖBERStöberiSDS4000Basic cableResolver MAT9421003 (4x(2x0,25)+2x0,5)C 9,5StöberiSDS4000Basic cableEncoder ED/EK MAT9421001 (4x(2x0,34)+4x0,5)C 10,5StöberiSDS4000Basic cableEncoder ES MAT9421002 (3x(2x0,5+2x0,25)+(4x0,25))C 12,5All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core394950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


MeasuringTPE● Minimum bending radius for use in EnergyChains ® : 10 x cable diameter● Colour: Yellow green (similar to RAL 6018)... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu395


BusTPE<strong>Chainflex</strong> ® -TPE Bus cable● Class 6.4.4● Oil-resistant● Shielded● Hydrolysis-resistant and microbe-resistant● Flame-retardant● Nominal voltage: 30 V● Total shield: Total shield: extremely readilybending/solid copper shield. Coverageapprox. 70% linear, approx. 90% opticalManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmBECKHOFFBeckhoffBasic cableZK1090-9191-xxxx MAT9385001 (2x(2x0,25))C 7,0All <strong>cables</strong> available in the lengths you require.Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.G = with green-yellow earth core x = without earth core396950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


BusTPE● Temperature range (moved): -35 °C to + 70°C● Minimum bending radius for use in EnergyChains ® : 12,5 x cable diameter● Colour: Red lilac (similar to RAL 4001)... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu397


ControlPVC<strong>Chainflex</strong> ® -PVC Control cable● Class 4.2.1● Flame-retardant● Temperature range (moved):-5 °C to + 70°C● Nominal voltage: 300/500 V● Minimum bending radius for use in EnergyChains ® : 7,5 x d < 10 travel;10 x d > 10 m travelManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmNUMNUMBasic cable*AGOFRU012Mxxx MAT9289005 4G 1,0 7,5NUMExtension cableAGOFRU012Mxxx MAT9289015 4G 1,0 7,5All <strong>cables</strong> available in the lengths you require.398Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ControlPVC... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu399


ControlPVC<strong>Chainflex</strong> ® -PVC Control cable● Class 5.3.2● Oil-resistant● Flame-retardant● Temperature range (moved):-5 °C to + 70°C● Nominal voltage: 300/500 V● Minimum bending radius for use in EnergyChains ® : 6,8-7,5 x cable diameter● Colour: Moss green (similar to RAL 6005)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmLenzeBasic cable*LENZEEWLLxxxGMS MAT9130031 3 G 1,0 7,0EYL002AxxxxL01A00 MAT9130040 5 G 1,0 8,5EYL002AxxxxL02A00 MAT9130041 5 G 1,0 8,5EYL002VxxxxA00J01 MAT9130042 5 G 1,0 8,5EYL002VxxxxA00J02 MAT9130043 5 G 1,0 8,5LenzeLinking cableEWLLxxxZM MAT9130032 3 G 1,0 7,0EYL002VxxxxL01J01 MAT9130044 5 G 1,0 8,5EYL002VxxxxL02J02 MAT9130045 5 G 1,0 8,5All <strong>cables</strong> available in the lengths you require.400Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ControlPVC... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu401


ControlTPE<strong>Chainflex</strong> ® -TPE Control cable● Class 7.4.4● oil-resistant and bio-oil-resistant● Hydrolysis-resistant and microbe-resistant● Temperature range (moved): -35 °C to +100°C● Nominal voltage: 300/500 V● Minimum bending radius for use in EnergyChains ® : 5 x cable diameter● Colour: Steel blue (similar to RAL 5011)ManufacturerPart No.igus ®Part No.Number of cores and conductornominal cross section [mm 2 ]ømmLenzeBasic cable*LENZEEWLLxxxGMS MAT9120031 3 G 1,0 6,0EYL002AxxxxL01A00 MAT9120040 5 G 1,0 7,0EYL002AxxxxL02A00 MAT9120041 5 G 1,0 7,0EYL002VxxxxA00J01 MAT9120042 5 G 1,0 7,0EYL002VxxxxA00J02 MAT9120043 5 G 1,0 7,0LenzeLinking cableEWLLxxxZM MAT9120032 3 G 1,0 6,0EYL002VxxxxL01J01 MAT9120044 5 G 1,0 7,0EYL002VxxxxL02J02 MAT9120045 5 G 1,0 7,0NUMBasic cable*NUMAGOFRU012Mxxx MAT9289007 4G 1,0 6,5NUMExtension cableAGOFRU012Mxxx MAT9289017 4G 1,0 7,5All <strong>cables</strong> available in the lengths you require.402Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.* igus ® gladly pre-harnesses the cable end according to your technical guidelines.G = with green-yellow earth core x = without earth core950 types from stock no cutting costs ...(for up to 10 cuts of the same type)


ControlTPE... no minimum order quantity ...igus ® GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu403


gusconnectors®


igus ®connectorsigus ®Connectors Type PageConnectorsSERIES A Signal connector 398M23 standard [6 to 19-pin]SERIES B Power connector 402Size 1 [6, 8 and 9-pin]SERIES B Power connector 404Size 1 [6, 8 and 9-pin]SERIES M17 Signal and power connector 405M17 signal [17-pin] and power connector [4 to 9-pin]SERIES C Power connector 408Size 1,5 [6, 8 and 9-pin]SERIES D Power connector 410Size 3 [6 und 8-pin]SERIES S Power connector 412Single-pinTools, accessories 414SUB-D Signal connector 424SUB-D Standard [9 to 44-pin]Glands 416Test igus ® !Order the service-pack today, get it tomorrow – from batch size 1The package contains:Your ordered connector together with contacts,installation instructions and a faxback order form.Just call us!Tel. +49-2203-9649-800405


SERIESAigus ® connectors SERIES Aaccording to Intercontec standardSignal connectorM23 standard [6 to 19-pin]Types● Connector, standard and push-pull version, angularconnector● Lead-through● Extension, standard or with central attachment● PG 13.5-installation box● Installation box straight with flange● Installation box angled and turnable flexed with flangeNumber of contacts ● 6.7, [8+1], 9, 10, 12, 16, 17, [16+3]Technical data of the SERIES ATemperature range -20 °C to 130 °CProtection class IP 66/67 [plugged]Electrical data 6 to 12-pinMax. rated current 10 ARated voltage160 V (AC/DC)Test voltage (L-L) 2500 VResistance< 5 mInsertion cycles > 50Electrical data 16 to [16+3]-pinMax. rated current 9 ARated voltage125 V (AC/DC)Test voltage (L-L) 2500 VResistance< 5 mInsertion cycles > 50Data according to VDE 0110/EN 61984, Clause 6.19.2.2Degree of pollution 3Over-voltage category IIIMax. height of operation 2000 mINTERCONTECUsed materialsHousingConnection nutZinc die-casting/brass, nickel-platedBrass, nickel-platedInsulation insert PA 6.6/PBT, UL 94/V0ContactsBrass, gold-platedSealsFPM/HNBRClamping ringBrass, nickel-platedHousing with SpeedTEC quick-release fastener page 421406+www.igus.eu/quickpinigus ® QuickPin – Configure ReadyCable ® online


SERIESASignal plug 8+1 pin, P-Type8 x female crimping contact 1.0 mm, Crimp area: Metal construction,nickel-platedOrder no.[8+1]-pin,3 coding slotsslitted crimp area: 0.14-1.0 mm 2 ,1xfemale crimping 2.0 mm,slitted crimp area: 0.35-2.5 mm 29.0-13.2 mm EMC shieldingMAT0179600 C1+4ConnectorSignal plug 12 pin,nickel-platedOrder no.MAT0179601E-Type12-pin,3 coding slotsFemale crimping contact 1.0 mm,slitted crimp area: 0.14-1.0 mm 2Crimp area:9.0-13.2 mmMetal construction,EMC shieldingC1Signal plug 16 pin,nickel-platedOrder no.MAT0179602P-Type16-pin,1 coding slotFemale crimping contact 1.0 mm, Crimp area:slitted crimp area: 0.14-1.0 mm 2 9.0-13.2 mmMetal construction,EMC shieldingC1Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Signal plug 17 pin,nickel-platedOrder no.MAT0179603P-Type17-pin,3 coding slotsFemale crimping contact 1.0 mm,slitted crimp area: 0.14-1.0 mm 2Crimp area:9.0-13.2 mmMetal construction,EMC shieldingC1igus ® GmbH51147 Köln, GermanySignal plug 16+3 pin, P-Type16 x female crimping contact 1.0 mm, Crimp area: Metal construction,nickel-platedOrder no.[16+3]-pin,1 coding slotslitted crimp area: 0.14-1.0 mm 2 ,3 x female crimping 0,5 mm,slitted crimp area: 0.14-1.0 mm 29.0-13.2 mm EMC shieldingMAT0179604 C1+5Housing with SpeedTEC quick-release fastener page 421... no minimum order quantitywww.igus.euinfo@igus.de407


SERIESAigus ® connectors SERIES Aaccording to Intercontec standardThe straight signal receptacle is assembled with the contactsand insulation bodies.The technical specifications apply accordingly. A cable clampis not required by virtue of the design.Lead-through,Metal construction,with connection nutaxial sealOrder no. 8+1 pinMAT0179605 C1+4Order no. 12 pinMAT0179606Order no. 16 pinMAT0179607Order no. 17 pinMAT0179608Order no. 16+3 pinMAT0179609 C1+5C1C1C1Signal extension 8+1 pin,nickel-platedOrder no.E-Type[8+1]-pin,3 coding slots8 x crimping contact 1.0 mm,crimp area: 0.14-1.0 mm 21 x crimping contact 2.0 mm,crimp area: 0.35-2.5 mm 2Crimp area:9.0-13.2 mmMetal construction,EMC shieldingMAT0179610 C1+4Signal extension 12 pin,nickel-platedOrder no.MAT0179611P-Type12-pin,3 coding slotsCrimping contact 1.0 mm,crimp area: 0.14-1.0 mm 2Crimp area:9.0-13.2 mmMetal construction,EMC shieldingC1INTERCONTEC408Signal extension 16 pin,nickel-platedOrder no.MAT0179612+E-Type16-pin,1 coding slotCrimping contact 1.0 mm,crimp area: 0.14-1.0 mm 2Crimp area:9.,0-13.2 mmHousing with SpeedTEC quick-release fastener page 421Metal construction,EMC shieldingwww.igus.eu/quickpinigus ® QuickPin – Configure ReadyCable ® onlineC1


SERIESASignal extension 17 pin,nickel-platedOrder no.MAT0179613E-Type17-pin,3 coding slotsCrimping contact 1.0 mm,crimp area: 0.14-1.0 mm 2Crimp area:9.0-13.2 mmMetal construction,EMC shieldingC1ConnectorSignal extension 16+3 pin,nickel-platedOrder no.E-Type[16+3]-pin,1 coding slot16 x crimping contact 1.0 mm,crimp area: 0.14-1.0 mm 23 x crimping contact 0,5 mm,crimp area: 0.14-1.0 mm 2Crimp area:9.0-13.2 mmMetal construction,EMC shieldingMAT0179614 C1+5Extension with centralattachmentOrder no. 8+1 pinMetal construction,EMC shieldingMAT0179615 C1+4Order no. 12 pinMAT0179616The extension with a central attachment is assembed withthe above-mentioned contacts, insulation bodies and cableclamp.The technical specifications apply accordingly.C1Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Order no. 16 pinMAT0179617C1Order no. 17 pinMAT0179618Order no. 16+3 pinMAT0179619 C1+5C1igus ® GmbH51147 Köln, GermanyHousing with SpeedTEC quick-release fastener page 421... no minimum order quantitywww.igus.euinfo@igus.de409


SERIESBigus ® connectors SERIES Baccording to Intercontec standardPower connectorSize 1 [6, 8 and 9-pin]Types● Connector, short and long, push-pull version,angular connector● Extension, standard or with central attachment● Lead-through● Installation box straight with flange● Installation box angled and turnable flexed with flangeNumber of contacts ● 6, 8, 9Technical data of the SERIES BTemperature range -20 °C to 130 °CProtection class IP 66/67 [plugged]Electrical data power contactsMax. rated current max. 28 A (6-pin)max. 30 A (8/9-pin)Rated voltage630 V (AC/DC)Test voltage (L-L) 6000 VResistance< 3 mInsertion cycles > 50Electrical data signal 8 u.9 pinMax. rated current 10 ARated voltage250 V (AC/DC)Test voltage (L-L) 2500 VResistance< 5 mInsertion cycles > 50Data according to VDE 0110/EN 61984, Clause 6.19.2.2Degree of pollution 3Over-voltage category IIIMax. height of operation 2000 mINTERCONTECUsed materialsHousing Zinc die-casting/brass, nickel-plated *Connection nut Brass, nickel-platedInsulation insert PA 6.6/PBT, UL 94/V0ContactsBrass, gold-platedSealsFPM/HNBRClamping ringBrass, nickel-plated*optional: stainless steelHousing with SpeedTEC quick-release fastener page 421410+www.igus.eu/quickpinigus ® QuickPin – Configure ReadyCable ® online


SERIESBSignal plug 6 pin,nickel-platedOrder no.MAT0179620P-Type6-pin6x HC-female crimping 2.0 mm,crimp area: 0.35-2.5 mm 2Crimp area:9.5-14.5 mmMetal construction,EMC shieldingC2ConnectorSignal plug 8 pin,P-Type 4 x HC-female crimping 2.0 mm, Crimp area: Metal construction,nickel-platedOrder no.8-pinCrimp area: 0.35-2.5 mm 24 x HC-female crimping 1,0 mm,Crimp area: 0.14-1.0 mm 29.5-14.5 mm EMC shieldingMAT0179621 C1+2Signal plug 9 pin,P-Type 4 x HC-female crimping 2.0 mm, Crimp area: Metal construction,nickel-platedOrder no.9-pincrimp area: 0.35-2.5 mm 25 x HC-female crimping 1.0 mm,crimp area: 0.14-1.0 mm 29.5-14.5 mm EMC shieldingMAT0179622 C1+2Tel. +49-2203-96 49-0Fax +49-2203-96 49-222The straight signal receptacle is assembled with abovementionedcontacts and insulation bodies. The technicalspecifications apply accordingly.A cable clamp is not required by virtue of the design.Lead-through,with connection nutOrder no. 6 pinMAT0178406Metal construction, axial sealOrder no. 8 pinMAT0175661 C1+2Order no. 9 pinMAT0179033 C1+2C2igus ® GmbH51147 Köln, GermanyHousing with SpeedTEC quick-release fastener page 421... no minimum order quantitywww.igus.euinfo@igus.de411


SERIESBigus ® connectors SERIES Baccording to Intercontec standardPower connectorSize 1 [6, 8 and 9-pin]Power extension 6 pin,nickel-platedOrder no.MAT0179623E-Type6-pin6 x crimping contact 2.0 mm,crimp area: 0.35-2.5 mm 2Crimp area:9.5-14.5 mmMetal construction,EMC shieldingC2/C3Power extension 8 pin,nickel-platedOrder no.MAT0179624E-Type8-pin4 x crimping contact 2.0 mm,crimp area: 0.35-2.5 mm 24 x crimping contact 1.0 mm,crimp area: 0.14-1.0 mm 2Crimp area:9.5-14.5 mmMetal construction,EMC shieldingC3Power extension 9 pin,nickel-platedOrder no.MAT0179625E-Type9-pin4 x crimping contact 2.0 mm,crimp area: 0.35-2.5 mm 25 x crimping contact 1.0 mm,crimp area: 0.14-1.0 mm 2Crimp area:9.5-14.5 mmMetal construction,EMC shieldingC3The extension with central attachment is assembed withthe above-mentioned contacts, insulation bodies and cableclamp.The technical specifications apply accordingly.INTERCONTEC412Extension with centralattachmentOrder no. 6 pinMAT0179626Order no. 8 pinMAT0179627Order no. 9 pinMAT0179628Housing with SpeedTEC quick-release fastener page 421+Metal construction,EMC shieldingC2/C3www.igus.eu/quickpinigus ® QuickPin – Configure ReadyCable ® onlineC3C9


igus ® connectors SERIES M17according to Intercontec standardSERIESM17Signal-und Power connectorM17 signal [17-pin] and power connector [4 to 9-pin]Types● Connector, standard and push-pull version● Installation box angled, turnable with flange● Extension, standard or with central attachment● Installation box angled and turnable flexed with flange● Installation box straight with flange● Installation box straight, connecting thread M17 x 0,75Number of contacts● Signal: 17 ● Power: 4, 7, 9ConnectorTechnical data of the M17 SERIESTemperature range -20 °C to 130 °CProtection class IP 67 [plugged]Electrical data signal 17 pinMax. rated current 3,6 ARated voltage63 V (AC /DC)Test voltage (L-L) 1500 VResistance< 15 mInsertion cycles > 50Electrical data power4 pin 7 pinMax. rated current 2,5mm 2 : 20 A 1 mm 2 : 10 A 1,5 mm 2 : 14 ARated voltage 630 V (AC /DC) 630 V (AC /DC)Test voltage (L-L) 6000 V 6000 VResistance < 5 m < 5 mInsertion cycles > 50 > 50Electrical data power 9 pinMax. rated current Signal: 3,6 A Power: 14 ARated voltage Signal: 63 V [AC/DC ] Power: 630 V [AC/DC ]Test voltage (L-L) Signal: 1500 V Power: 6000 VResistance Signal: < 15 m Power: < 5 mInsertion cycles > 50Data according to VDE 0110/EN 61984, Clause 6.19.2.2Degree of pollution 3Over-voltage category IIIMax. height of operation 2000 mUsed materialsHousing Zinc die-casting/brass, nickel-platedInsulation insert PBT, UL 94/V0Seals FPMConnection nut Brass, nickel-platedContacts Brass, gold-platedClamping ring Brass,nickel-platedTel. +49-2203-96 49-0igus ® GmbHFax +49-2203-96 49-22251147 Köln, GermanyHousing with SpeedTEC quick-release fastener page 421... no minimum order quantitywww.igus.euinfo@igus.de413


SERIESM17igus ® connectors SERIES M17according to Intercontec standardSignal-und Power connectorM17 signal [17-pin] and power connector [4 to 9-pin]Signal plug 17 pin,nickel-platedOrder no.MAT0179639P-Type17-pinFemale crimping 0.6 mm,slitted crimp area: 0.14-0.5 mm 2Crown clamp,crimp area:9.5-12.0 mmMetal construction,EMC shieldingBPower plug 4 pin,nickel-platedOrder no.MAT0179641P-Type4-pinFemale crimping 0,5 mm,slitted crimp area: 0.35-2.5 mm 2Crown clamp,crimp area:9.5-12.0 mmMetal construction,EMC shieldingC6Power plug 7 pin,nickel-platedOrder no.MAT0179643P-Type7-pinHC-female crimping 1.0 mm,Crimp area: 0.5-1.5 mm 2Crown clamp,crimp area:9.5-12.0 mmMetal construction,EMC shieldingC1INTERCONTEC414Power plug 9 pin,nickel-platedOrder no.MAT0179645+P-Type9-pin4 x HC-female crimping 1.0 mm,Crimp area: 0.5-1.5 mm 25 x female crimping 0.6 m,slitted crimp area: 0.14-0.5 mm 2Crown clamp,crimp area:9.5-12.0 mmHousing with SpeedTEC quick-release fastener page 421Metal construction,EMC shieldingC1+Bwww.igus.eu/quickpinigus ® QuickPin – Configure ReadyCable ® online


SERIESM17Signal-und Power connectorM17 signal [17-pin] and power connector [4 to 9-pin]Signal extension 17 pin,nickel-platedOrder no.MAT0179640E-Type17-pinCrimping contact 0.6 mm,crimp area: 0.14-0.5 mm 2Crown clamp,crimp area:9.5-12.0 mmMetal construction,EMC shieldingBConnectorPower extension 4 pin,nickel-platedOrder no.MAT0179642E-Type4-pinCrimping contact 0,5 mm,crimp area: 0.35-2.5 mm 2Crown clamp,crimp area:9.5-12.0 mmMetal construction,EMC shieldingC6Power extension 7 pin,nickel-platedOrder no.MAT0179644E-Type7-pinCrimping contact 1,0 mm,crimp area: 0.5-1.5 mm 2Crown clamp,crimp area:9.5-12.0 mmMetal construction,EMC shieldingC1Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Power extension 9 pin,nickel-platedOrder no.MAT0179646E-Type9-pin4 x crimping contact 1.0 mm,Crimp area: 0.5-1.5 mm 25 x crimping contact 0.6 mmCrimp area: 0.14-0.5 mm 2Crown clamp,crimp area:9.5-12.0 mmMetal construction,EMC shieldingC1+Bigus ® GmbH51147 Köln, GermanyHousing with SpeedTEC quick-release fastener page 421... no minimum order quantitywww.igus.euinfo@igus.de415


SERIESCigus ® connectors SERIES Caccording to Intercontec standardPower connectorSize 1,5 [6, 8 and 9-pin]Types● Connector, angular connector● Extension● Lead-through● Installation box straight with flange● Installation box angled and turnable flexed with flangeNumber of contacts● 6, 8, 9Technical data of the SERIES CTemperature range -20 °C to 130 °CProtection class IP 66/67 [plugged]Electrical data power contactsMax. rated current 75 ARated voltage630 V (AC/DC)Test voltage (L-L) 6000 VResistance< 1 mInsertion cycles > 50Electrical data signal contactsMax. rated current 30 ARated voltage630 V (AC/DC)Test voltage (L-L) 4000 VResistance< 3 mInsertion cycles > 50Data according to VDE 0110/EN 61984, Clause 6.19.2.2Degree of pollution 3Over-voltage category IIIMax. height of operation 2000 mUsed materialsHousingConnection nutMagnesium die-casting/AluminumBrass, nickel-platedInsulation insert PA 6.6/PBT, UL 94/V0ContactsBrass, gold-platedSealsFPM/HNBRClamping ringBrass, nickel-platedINTERCONTECSignal plug 6 pin,nickel-platedOrder no.MAT0179629P-Type6-pin4 x HC-female crimping 3.6 mm, Crimp area:crimp area: 1.5-10.0 mm 2 9,0-16,5 mm2 x HC-female crimping 2.0 mm,crimp area: 0.5-2.5 mm 2Metal construction,EMC shieldingD9+C2416+www.igus.eu/quickpinigus ® QuickPin – Configure ReadyCable ® online


SERIESCSignal plug 8 pin,nickel-platedOrder no.MAT0179630P-Type8-pin4 x HC-female crimping 3.6 mm, Crimp area:crimp area: 1.5-10.0 mm 2 9.0-16.5 mm4 x HC-female crimping 2.0 mm,crimp area: 0.5-2.5 mm 2Metal construction,EMC shieldingD9+C2ConnectorSignal plug 9 pin,nickel-platedOrder no.MAT0179631P-Type9-pin4 x HC-female crimping 3.6 mm, Crimp area:crimp area: 1.5-10.0 mm 2 9.0-16.5 mm5 x HC-female crimping 2.0 mm,crimp area: 0.5-2.5 mm 2Metal construction,EMC shieldingD9+C2Power extension 6 pin,nickel-platedOrder no.MAT0179632E-Type6-pin4 x crimping contact 3.6 mm,crimp area: 1.5-10.0 mm 22 x crimping contact 2.0 mm,crimp area: 0.5-2.5 mm 2Crimp area:9.0-16.5 mmMetal construction,EMC shieldingD9+C3Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Power extension 8 pin,nickel-platedOrder no.MAT0179633E-Type8-pin4 x crimping contact 3.6 mm,crimp area: 1.5-10.0 mm 24 x crimping contact 2.0 mm,crimp area: 0.5-2.5 mm 2Crimp area:9.0-16.5 mmMetal construction,EMC shieldingD9+C3igus ® GmbH51147 Köln, GermanyPower extension 9 pin,nickel-platedOrder no.MAT0179634E-Type9-pin4 x crimping contact 3.6 mm,crimp area: 1.5-10.0 mm 25 x crimping contact 2.0 mm,crimp area: 0.5-2.5 mm 2Crimp area:9.0-16.5 mm... no minimum order quantityMetal construction,EMC shieldingD9+C3www.igus.euinfo@igus.de417


SERIESDigus ® connectors SERIES Daccording to Intercontec standardPower connectorSize 3 [6 und 8-pin]Types● Connector● Extension● Installation box straight with flange● Installation box angled with flangeNumber of contacts● 6, 8Technical data of the SERIES CTemperature range -20 °C to 130 °CProtection class IP 66/67 [plugged]Electrical data power contactsMax. rated current max. 150 ARated voltage630 V (AC/DC)Test voltage (L-L) 6000 VResistance< 90 mInsertion cycles > 50Electrical data signal contactsMax. rated current 12 ARated voltage250 V (AC/DC)Test voltage (L-L) 4000 VResistance< 5 mInsertion cycles > 50Data according to VDE 0110/EN 61984, Clause 6.19.2.2Degree of pollution 3Over-voltage category IIIMax. height of operation 2000 mUsed materialsHousingConnection nutZink die-casting, nickel-platedBrass, nickel-platedInsulation insert PA 6.6/PBT, UL 94/V0ContactsBrass, silver-/gold-platedSealsFPMClamping ringAluminium, nickel-platedINTERCONTEC418+www.igus.eu/quickpinigus ® QuickPin – Configure ReadyCable ® online


SERIESDSignal plug 6 pin,nickel-platedOrder no.MAT0179635P-Type6-pinPower:4 x female crimping 10.0 mm,crimping range:10.0 mm 2 /AWG8Signal:2 x female crimping 1.6 mm,crimping range: 0,5 mm 2Crown clamp,crimp area:17.0-36.0 mmMetal construction,EMC shieldingE10+C7ConnectorSignal plug 8 pin,nickel-platedOrder no.MAT0179636Power extension 6 pin,nickel-platedOrder no.MAT0179637Power extension 8 pin,nickel-platedOrder no.MAT0179638P-Type8-pinE-Type6-pinE-Type8-pinPower:4 x female crimping 10.0 mm,crimping range:10.0 mm 2 /AWG8Signal:4 x female crimping 1.6 mm,crimping range: 0,5 mm 2Power:4 x crimping contact 10.0 mmcrimping range:10.0 mm 2 /AWG8Signal:2 x crimping contact 1.6 mmcrimping range: 0,5 mm 2Power:4 x crimping contact 10.0 mmcrimping range:10.0 mm 2 /AWG8Signal:4 x crimping contact 1.6 mmcrimping range: 0,5 mm 2Crown clamp,crimp area:17.0-36.0 mmCrown clamp,crimp area:17.0-36.0 mmCrown clampCrimp area:17.0-36.0 mm... no minimum order quantityMetal construction,EMC shieldingMetal construction,EMC shieldingMetal construction,EMC shieldingE10+C8E10+C7E10+C8Tel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.de419


SERIES Sigus ® connectors SERIES Saccording to Intercontec standardPower connectorSingle-pinTypes● Connector● Extension● Installation box straight with flangeNumber of contacts● 1Technical data of the SERIES STemperature range -20 °C to 130 °CProtection class IP 66/67 [plugged]Electrical data of the SERIES SRated voltage630 V (AC/DC)Test voltage (L-L) 8000 VResistance< 110 mInsertion cycles > 50Max. rated currentfor crimping range 10 mm 2 : 80 Afor crimping range 16 mm 2 : 100 Afor crimping range 25 mm 2 : 130 Afor crimping range 35 mm 2 : 160 Afor crimping range 50 mm 2 : 200 AData according to VDE 0110/EN 61984, Clause 6.19.2.2Degree of pollution 3 [2]Over-voltage category IVMax. height of operation 2000 mUsed materialsHousingConnection nutZinc die-casting/brass, nickel-platedBrass, nickel-platedInsulation insert PA 6.6mod., UL 94/V0ContactsBrass, silver-platedSealsFPMClamping ringBrass, nickel-platedINTERCONTECSignal plug 1 pin,nickel-platedOn requestMAT0179669P-Type1-pinFemale crimping 8.0 mm,crimping range: 10.0 mm 2Crown clamp,crimp area:9.5-14.5 mmMetal construction,EMC shieldingE10420+www.igus.eu/quickpinigus ® QuickPin – Configure ReadyCable ® online


SERIES SPower extension 1 pin,nickel-platedMAT0179670E-Type1-pinCrimping contact 8.0 mm,crimping range: 10.0 mm 2Crown clamp,Crimp area:9.5-14.5 mmMetal construction,EMC shieldingE10ConnectorPower installation box straight,long, 1 pin, nickel-platedOn requestE-Type1-pinCrimping contact 8.0 mm, Not necessary Metal construction,crimping range: 10.0 mm 2 axial sealE10Connector – quick release fastenerThe quick-release fastener SpeedTEC isavail able for the types plugs, extensions,straight mounting boxes and angled mountingboxes from the series A, B, C and M17.The SpeedTEC connectors are sealed accordingto IP67 and conform to national andinternational certifications, including VDE,UL/CSA and CCC.Please note:SpeedTEC extensions and installation boxesare compatible with the available screw solutions.However, the type SpeedTEC plug housingcan only be connected with other SpeedTECtypes.... no minimum order quantityTel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.de421


ToolsAccessoriesigus ® tools, accessoriesaccording to Intercontec standardCrimp pliers for SERIES A and BAHand-Crimp pliersfor Ø 1 mm contactstill core cross section 1 mm 2complete with positioning insertOn requestPositioning insertfor Ø 0.6 mm contactsOn requestMAT01710294Crimp pliers for SERIES M17MAT0179467BMAT0178919Hand-Crimp pliersfor Ø 0.6 mm contactstill core cross section 0,5mm 2complete with positioning insertOn requestAlternative crimp pliers for A or C4-thorn crimp pliersfor Ø 0,14mm 2 to 6.0mm 2 contactsdelivered with locatorOn requestMAT01713970Crimp pliers for SERIES A, B, C, D and M171 2 3CINTERCONTECHand-Crimp pliersfor Ø 1 mm contacts and Ø 2 mmcontacts to core cross section 4 mm 2inclusive positioning carrierOn requestPositioning insertfor Ø 1 mm contactsOn requestPositioning insertfor Ø 2 mm contactsOn requestPositioning insertfor Ø 1 mm and Ø 2 mmcontactsOn requestMAT0175736 MAT0178195 MAT0178196 MAT01778554 5 6 7 8Positioning insertfor Ø 2 mm contactsPositioning insertfor Ø 0,5 mm contactsPositioning insertfor Ø 0.5-2.5 mmContactsPositioning insertfor Ø 1.6 mm contactsPositioning insertfor Ø 1.6 mm contacts422On requestOn requestOn requestOn requestOn requestMAT01714573 MAT01714574 MAT0178920 MAT0177853 MAT01714575


ToolsAccessoriesCrimp pliers for SERIES CDMAT0179194Crimp pliers for SERIES CHand-Crimp pliersfor Ø 3.6 mm contactstill core cross section 16 mm 2inclusive positioning carrierOn request9MAT0179195Positioning insertfor Ø 3.6 mm contactsOn requestConnectorPneumatic Crimp pliersfor Ø 3.6 mm andØ 2.0 mm contactsCore cross section 1.5-16 mm 2On requestCrimping insert for pneumatic crimp pliersContactCrimp areaOn requestPin Ø 2.0 mmBush Ø 3.6 mm1.5/2.5 mm 21.5/2.5 mm 2On requestPin Ø 3.6 mmBush Ø 3.6 mm4.0/6.0 mm 2On requestLocator for pneumatic crimp pliersPin Ø 3.6 mmBush Ø 3.6 mm10.0 mm 2On requestPin Ø 3.6 mmBush Ø 3.6 mm16.0 mm 2On requestTel. +49-2203-96 49-0Fax +49-2203-96 49-222ContactCrimp areaOn requestPin Ø 2.0 mmBush Ø 2.0 mm1.5/2.5 mm 21.5/2.5 mm 2On requestCrimping insert for SERIES S and DPin Ø 3.6 mmBush Ø 3.6 mm1.5-10.0 mm 2On requestPin Ø 3.6 mmBush Ø 3.6 mm1.5-16.0 mm 2On requestE10 11 12 13igus ® GmbH51147 Köln, GermanyBattery-powered Crimp pliers,B131-CCrimping insertup to 10 mm 2 , 16 mm 2Crimping insertup to 25 mm 2Crimping insertup to 35 mm 2Crimping insertup to 50 mm 2On requestOn requestOn requestOn requestOn requestMAT0177854 MAT01713679 MAT01713678 MAT01713677 MAT01713676www.igus.euinfo@igus.de423


SUB-Digus ® Connectors SUB-Daccording to FTC standardSignal connectorSUB-D standard [9 to 44-pin]Types● Connector, standard- and angular connectorNumber of contacts● Standard 9, 15, 25● High Density 15, 26, 44Technical dataTemperature range -35 °C to 100 °CElectrical dataMax. rated current 5 ATest voltage(L-L) 1200 VResistance10 16 /cmInsertion cycles 50Used materialsHousingInsulation insertContactsZinc die-casting, nickel-platedGlass fibre reinforced polyesterCopper alloy, gold-platedFCT424+www.igus.eu/quickpinigus ® QuickPin – Configure ReadyCable ® online


SUB-DSize 1 9-pin - HD15-pinOrder no.MAT01716504Solder contact Pin9-pin standardMetal hood, straightConnectorSize 1 9-pin - HD15-pinOrder no.MAT01716505Solder contact Socket9-pin standardMetal hood, straightSize 1 9-pin - HD15-pinOrder no.MAT01716506Solder contact PinHighDensity 15-pinMetal hood, straightSize 1 9-pin - HD15-pinOrder no.MAT01716507Size 1 9-pin - HD15-pinOrder no.MAT01716508Solder contact SocketHighDensity 15-pinSolder contact Pin9-pin standardMetal hood, straightMetal hood, angledTel. +49-2203-96 49-0Fax +49-2203-96 49-222Size 1 9-pin - HD15-pinOrder no.MAT01716509Size 1 9-pin - HD15-pinOrder no.MAT01716510Solder contact Socket9-pin standardSolder contact PinHighDensity 15-pinMetal hood, angledMetal hood, angledigus ® GmbH51147 Köln, GermanySize 1 9-pin - HD15-pinOrder no.MAT01716511Solder contact SocketHighDensity 15-pinMetal hood, angled... no minimum order quantitywww.igus.euinfo@igus.de425


SUB-Digus ® Connectors SUB-Daccording to FTC standardSize 2 15-pin - HD26-pinOrder no.MAT01716512Solder contact Pin15-pin standardMetal hood, straightSize 2 15-pin - HD26-pinOrder no.MAT01716513Solder contact Socket15-pin standardMetal hood, straightSize 2 15-pin - HD26-pinOrder no.MAT01716514Solder contact PinHighDensity 26-pinMetal hood, straightSize 2 15-pin - HD26-pinOrder no.MAT01716515Solder contact SocketHighDensity 26-pinMetal hood, straightSize 2 15-pin - HD26-pinOrder no.MAT01716516Solder contact Pin15-pin standardMetal hood, angledSize 2 15-pin - HD26-pinOrder no.MAT01716517Solder contact Socket15-pin standardMetal hood, angledSize 2 15-pin - HD26-pinOrder no.MAT01716518Solder contact PinHighDensity 26-pinMetal hood, angledFCTSize 2 15-pin - HD26-pinOrder no.MAT01716519Solder contact SocketHighDensity 26-pinMetal hood, angled426+www.igus.eu/quickpinigus ® QuickPin – Configure ReadyCable ® online


SUB-DSize 3 25-pin - HD44-pinOrder no.MAT01716520Solder contact Pin25-pin standardMetal hood, straightConnectorSize 3 25-pin - HD44-pinOrder no.MAT01716521Solder contact Socket25-pin standardMetal hood, straightSize 3 25-pin - HD44-pinOrder no.MAT01716522Solder contact PinHighDensity 44-pinMetal hood, straightSize 3 25-pin - HD44-pinOrder no.MAT01716523Size 3 25-pin - HD44-pinOrder no.MAT01716524Solder contact SocketHighDensity 44-pinSolder contact Pin25-pin standardMetal hood, straightMetal hood, angledTel. +49-2203-96 49-0Fax +49-2203-96 49-222Size 3 25-pin - HD44-pinOrder no.MAT01716525Size 3 25-pin - HD44-pinOrder no.MAT01716526Solder contact Socket25-pin standardSolder contact PinHighDensity 44-pinMetal hood, angledMetal hood, angledigus ® GmbH51147 Köln, GermanySize 3 25-pin - HD44-pinOrder no.MAT01716527Solder contact SocketHighDensity 44-pinMetal hood, angled... no minimum order quantitywww.igus.euinfo@igus.de427


SERIESHSK-Kigus ® Cable glands HSK-KMaterial PA V0 according to UL 94Shaped packingNBRProtection classIP 68-10 bar / IP 69Kwithin the specified clamping range onlywith optional O-RingContinuous operatingtemperature -40 °C-100 °CColour gray RAL 7035AGHGLAG GL H Pack Part No. Order No.mm mm mm mm Size grayM 12 x 1,5 3 - 6.5 8 21 15 5 1.209.1200.50 MAT0179492M 12 x 1,5 2 - 5 8 21 15 5 1.209.1200.51 MAT01712319M 16 x 1,5 4 - 8 8 22 19 5 1.209.1600.50 MAT0179493M 16 x 1,5 2 - 6 8 22 19 5 1.209.1600.51 MAT01712320M 16 x 1,5 5 - 10 8 25 22 5 1.219.1600.50 MAT01712321M 20 x 1,5 6 - 12 9 27 24 5 1.209.2000.50 MAT0179494M 20 x 1,5 5 - 9 9 27 24 5 1.209.2000.51 MAT01712322M 20 x 1,5 10 - 14 9 28 27 5 1.219.2000.50 MAT0179563M 25 x 1,5 13 - 18 11 31 33 5 1.209.2500.50 MAT0179495M 25 x 1,5 9 - 16 11 31 33 5 1.209.2500.51 MAT01712323M 32 x 1,5 18 - 25 11 39 42 5 1.209.3200.50 MAT0179496M 32 x 1,5 13 - 20 11 39 42 5 1.209.3200.51 MAT01712324M 40 x 1,5 22 - 32 13 48 53 5 1.209.4000.50 MAT0179497M 40 x 1,5 20 - 26 13 48 53 5 1.209.4000.51 MAT01712325M 50 x 1,5 32 - 38 13 49 60 5 1.209.5000.50 MAT0179498M 50 x 1,5 25 - 31 13 49 60 5 1.209.5000.51 MAT01712326M 63 x 1,5 37 - 44 14 49 65 / 68 5 1.209.6300.50 MAT0179499M 63 x 1,5 29 - 35 14 49 65 / 68 5 1.209.6300.51 MAT01712327Request your personal savings offer.Fax: +49-2203-9649-222INTERCONTECcable diameters in mm1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45M 12M 16M 20M 25M 32M 40M 50M 63428


K-Counter nutsSERIESHSK-KMaterialSB / PAContinuous operatingtemperature -20 °C-40 °C (SB)-40 °C-100 °C (PA)Colour gray RAL 7035Cable glandsIG H Pack Part No. Order No.mm mm SizeM 12 x 1,5 5 17 5 1.262.1200.50 MAT0179500M 16 x 1,5 5 22 5 1.262.1600.50 MAT0179501M 20 x 1,5 6 27 5 1.262.2000.50 MAT0179502M 25 x 1,5 7 36 5 1.262.2500.50 MAT0179503M 32 x 1,5 7 41 5 1.262.3200.50 MAT0179504M 40 x 1,5 7 50 5 1.262.4000.50 MAT0179505M 50 x 1,5 8 60 5 1.262.5000.50 MAT0179506M 63 x 1,5 8 75 5 1.262.6300.50 MAT0179507Request your personal savings offer.Fax: +49-2203-9649-222Tel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germany... no minimum order quantitywww.igus.euinfo@igus.de429


SERIESHSK-Migus ® Cable glands HSK-MMaterialClamping insertShaped packingO-RingProtection classContinuous operatingtemperature -40 °C-100 °CBrass, nickel-platedPANBRNBRIP 68-10 bar / IP 69Kwithin the specified clamping range onlyAGHGLAG GL H Pack Part No. Order No.mm mm mm mm Size grayM 12 x 1,5 3 - 6.5 6.5 19 14 5 1.609.1200.50 MAT0179476M 12 x 1,5 2 - 5 6.5 19 14 5 1.609.1200.51 MAT01712328M 16 x 1,5 4 - 8 6 21 17 / 19 5 1.609.1600.50 MAT0179477M 16 x 1,5 2 - 6 6 21 17 / 19 5 1.609.1600.51 MAT01712329M 16 x 1,5 5 - 10 6 22 20 5 1.609.1611.50 MAT01712330M 20 x 1,5 6 - 12 6 23 22 5 1.609.2000.50 MAT0179478M 20 x 1,5 5 - 9 6 23 22 5 1.609.2000.51 MAT01712331M 20 x 1,5 10 - 14 6 24 24 5 1.609.2016.50 MAT0179562M 25 x 1,5 13 - 18 7 26 30 5 1.609.2500.50 MAT0179479M 25 x 1,5 9 - 16 7 26 30 5 1.609.2500.51 MAT01711769M 32 x 1,5 18 - 25 8 31 40 5 1.609.3200.50 MAT0179480M 32 x 1,5 13 - 20 8 31 40 5 1.609.3200.51 MAT01712332M 40 x 1,5 22 - 32 8 37 50 5 1.609.4000.50 MAT0179481M 40 x 1,5 20 - 26 8 37 50 5 1.609.4000.51 MAT01712333M 50 x 1,5 32 - 38 9 37 57 5 1.609.5000.50 MAT0179482M 50 x 1,5 25 - 31 9 37 57 5 1.609.5000.51 MAT01712334M 63 x 1,5 37 - 44 10 38 64 / 68 5 1.609.6300.50 MAT0179483M 63 x 1,5 29 - 35 10 38 64 / 68 5 1.609.6300.51 MAT01712335Request your personal savings offer.Fax: +49-2203-9649-222INTERCONTEC430cable diameters in mm1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45M 12M 16M 20M 25M 32M 40M 50M 63


M-Counter nutsSERIESHSK-MMaterialBrass, nickel-platedCable glandsIG H Pack Part No. Order No.mm mm SizeM 12 x 1,5 2,8 15 5 1.161.1200.50 MAT0179484M 16 x 1,5 2,8 19 5 1.161.1600.50 MAT0179485M 20 x 1,5 3,0 23 5 1.161.2000.50 MAT0179486M 25 x 1,5 3,5 29 5 1.161.2500.50 MAT0179487M 32 x 1,5 4,0 36 5 1.161.3200.50 MAT0179488M 40 x 1,5 4,5 45 5 1.161.4000.50 MAT0179489M 50 x 1,5 5,5 55 5 1.161.5000.50 MAT0179490M 63 x 1,5 6,0 70 5 1.161.6300.50 MAT0179491Request your personal savings offer.Fax: +49-2203-9649-222Tel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germany... no minimum order quantitywww.igus.euinfo@igus.de431


SERIESHSK-M-EMVigus ® Cable glands HSK-M-EMVMaterialBrass, nickel-platedClamping insertPAShaped packingNBRO-RingNBRProtection classIP 68-10 bar / IP 69Kwithin the specified clamping range onlyContinuous operatingtemperature -40 °C-100 °CAGHGLAG GL H Pack Part No. Order No.mm mm mm mm Size grayM 12 x 1,5 3 - 6.5 6.5 19 14 5 1.691.1200.50 MAT0179508M 12 x 1,5 2 - 5 6.5 19 14 5 1.691.1200.51 MAT01712336M 16 x 1,5 5 - 10 6 22 20 5 1.691.1600.50 MAT0179509M 16 x 1,5 3 - 7 6 22 20 5 1.691.1600.51 MAT01712337M 20 x 1,5 10 - 14 6 23 24 5 1.691.2000.50 MAT0179510M 20 x 1,5 7 - 12 6 23 24 5 1.691.2000.51 MAT01712338M 25 x 1,5 13 - 18 7 24 30 5 1.691.2500.50 MAT0179511M 25 x 1,5 9 - 16 7 24 30 5 1.691.2500.51 MAT01712339M 32 x 1,5 18 - 25 8 31 40 5 1.691.3200.50 MAT0179512M 32 x 1,5 13 - 20 8 31 40 5 1.691.3200.51 MAT01712340M 40 x 1,5 22 - 32 8 37 50 5 1.691.4000.50 MAT0179513M 40 x 1,5 20 - 26 8 37 50 5 1.691.4000.51 MAT01712341M 50 x 1,5 32 - 38 9 37 57 5 1.691.5000.50 MAT0179514M 50 x 1,5 25 - 31 9 37 57 5 1.691.5000.51 MAT01712342M 63 x 1,5 37 - 44 10 38 64 / 68 5 1.691.6300.50 MAT0179515M 63 x 1,5 29 - 35 10 38 64 / 68 5 1.691.6300.51 MAT01712343Request your personal savings offer.Fax: +49-2203-9649-222INTERCONTEC432cable diameters in mm1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45M 12M 16M 20M 25M 32M 40M 50M 63


HSK-EMV-Industry standardSERIESHSK-M-EMV-DHSK-M-EMVFlexible overlapping clampingsplines prevent the form sealfrom being pulled out of thefitting.Cable glandsThe internal sealing edgeresults in a superior sealbetween the splined Nylonclamping insert and the nickelplated brass body.HSK-M-EMV-DPatented 360° grounding dueto the internal O-Ring, whichresults in a perfect contactbetween braided shield ofcable and fitting.Flexible overlapping clampingsplines prevent the form sealfrom being pulled out of thefitting.Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Metalized spline insert provideselectrical conductivity.igus ® GmbH51147 Köln, GermanyFlexible contact points allowcontact with variable braiddiameters.... no minimum order quantitywww.igus.euinfo@igus.de433


SERIESHSK-M-EMV-Digus ® Cable glands HSK-M-EMV-DMaterialClamping insertShaped packingO-RingProtection classContinuous operatingtemperature -40 °C-100 °CBrass, nickel-platedMetal coated PANBRNBRIP 68-10 bar / IP 69Kwithin the specified clamping range onlyAGHGLAG GL H Pack Part No. Order No.mm mm mm mm Size grayM 12 x 1,5 3 - 6.5 6.5 25 14 5 1.631.1200.50 MAT0179524M 16 x 1,5 5 - 10 6 32 20 5 1.631.1600.50 MAT0179525M 20 x 1,5 10 - 14 6 33 24 5 1.631.2000.50 MAT0179526M 25 x 1,5 13 - 18 7 39 30 5 1.631.2500.50 MAT0179527M 32 x 1,5 18 - 25 8 45 40 5 1.631.3200.50 MAT0179528M 40 x 1,5 24 - 32 8 51 50 5 1.631.4000.50 MAT0179529M 50 x 1,5 32 - 38 9 57,5 57 5 1.631.5000.50 MAT0179530M 63 x 1,5 37 - 44 10 52 64 / 68 5 1.631.6300.50 MAT0179531Request your personal savings offer.Fax: +49-2203-9649-222INTERCONTEC434cable diameters in mm1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45M 12M 16M 20M 25M 32M 40M 50M 63


EMV-Counter nutsSERIESHSK-M-EMV-DMaterialBrass, nickel-platedIGSHCable glandsIG H S Pack Part No. Order No.mm mm mm SizeM 12 x 1,5 2.8 15 0.7 5 1.167.1200.50 MAT0179516M 16 x 1,5 2.8 19 0.7 5 1.167.1600.50 MAT0179517M 20 x 1,5 3.0 24 0.7 5 1.167.2000.50 MAT0179518M 25 x 1,5 3.5 30 0.7 5 1.167.2500.50 MAT0179519M 32 x 1,5 4.5 36 0.7 5 1.167.3200.50 MAT0179520M 40 x 1,5 5.0 46 0.7 5 1.167.4000.50 MAT0179521M 50 x 1,5 5.0 60 0.7 5 1.167,5000.50 MAT0179522M 63 x 1,5 6.0 70 0.7 5 1.167.6300.50 MAT0179523Request your personal savings offer.Fax: +49-2203-9649-222Tel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germany... no minimum order quantitywww.igus.euinfo@igus.de435


VAKAT


train Relief


ChainfixOverview Strain Relief SystemChainfix steel clamps and Chainfix stainless-steel clamps –Max. pull forces, adjustable with hexagon socketPage 440Chainfix clips – High pull forces, plug-in Modular snap-on strainrelief devicePage 442Chainfix Nugget – Strain relief for small space and <strong>cables</strong> up to20 mm o.d.Page 443Strain relief separator – With integrated teethPage 444Tiewrap plates – For cable tiewrap universal, bolted or clip-onPage 445Chainfix-tiewrap plates – For strain relief with cable tiewrapsfor C-profile, clip-onPage 446igus ® Blocks – Special strain relief for hoses. A Modular, spacesavingsystemPage 447438


igus ® Chainfix Strain ReliefChainfixReduced overall heightSpace-savingLong-term durability fordynamic applicationTel. +49-2203-96 49-0Fax +49-2203-96 49-222Strain relief devicesSuitable for integration in the igus ®connection element KMA (German abbr. =plastic-metal connection elements)High tensile strength due toribbed plastic troughsFor one cable, or for two or three<strong>cables</strong> on top of one anotherBlack painted or stainless steelfrom stock439


ChainfixChainfix for Energy Chain Systems ®Strain relief devices for Energy Chains ® with igus ® strap clipsand igus ® press-fit elementsigus ® Energy Chain Systems ®The principle of the strap clips has proved to be extremely reliableas a strain relief device for igus ® Energy Chain Systems ® .Important improvements are characteristic features of theigus ® own "Chainfix" product series:● igus ® Chainfix reduces the overall height due to optimumhousing height● Long-term durability for dynamic applications due to improvedpress-fit elements.● Suitability for integration in the KMA connection element.– Space-saving and time-saving assembly– Possibility of delivery for complete systems with <strong>cables</strong> andassembled strain relief device.● Improved foot for facilitated installation on the C profile.KMA connection element with integratedC profile and Chainfix24°Ideally, the <strong>cables</strong> must be fastened at both ends of the EnergyChains ® . The <strong>cables</strong> must, however, at least be fastened to themoving mounting bracket of the Energy Chains ® .Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Characteristic features of the igus ® Chainfix strap clips● Optimized height due to newly developed housing.● Improved foot for facilitated installation on the C profile.● Good visual effects due to black housing body and blackthreaded setscrews.● Easy to assemble due to setscrews that are screwed usingan Allen key.Characteristic features of the igus® press-fit elementsEasy installation of the strap clip due toimproved footigus ® GmbH51147 Köln, Germany● Long supporting surface improves the stability of the strap clip.● High inherent rigidity increases the operating safety.● Integrated ribs prevent the cable from detaching itself from thestrain relief device.Overall heightWhen the Energy Chains ® glide along on themselves in the case oflong distances of travel, the screw heads of the strain relief deviceat the fixed point of the chain must possess a separating distanceof at least 10 mm to the top edge of the Energy Chains ® . Our newlydeveloped clip housing with setscrews reduce the overall heightby as much as 15 mm compared with conventional strap clips.Reduced overall height due to setscrewand optimum housing heightRibswww.igus.euinfo@igus.deNew pressure trough, mating trough andpress trough with ribs for better long-termidurability440


Chainfix test resultsChainfixThree times higher tensile strength than withstandard-type strap clipsStandard-type strap clip made of hot-galvanized steel, doubletrough and press trough made of impact-resistant plastic (Art. no.CF14.1.Z, standard elements)Strap clip as described above, double trough and press troughmade of igumid G (Art. no. CFY14.1)Strap clip "Chainfix", mating trough and press trough made of igumidG (Art. no. CFX14.1)Results: Strain relief element saddle clamps loosen at 1.000 N ofpull force. The resulting diagonal position of the saddle clamp distortsthe screw. Strain relief element saddle clamps loosen at 1.750 Nof pull force. The improved igumid G saddle clamps attempt to holdthe cable, causing the outer jacket to "peel." Strain relief element (igus ®Chainfix system) saddle clamps loosen and slant 5º at 1.750 N.At 2.500 N of pull force, the cable jacket bunches up behind the clampand, at 3.500 N of pull force, the clamps loosen completely and thecable becomes inoperative.Final result: The tensile strength of the strap clip "Chainfix" developedby igus ® is three times higher than the tensile strength ofstandard-type strain relief devices.Delivery program elements of the Chainfix strain relief devices:Chainfix strap clip with setscrew and press trough, double trough,mating trough C profileMaterials: igus ® strap clip: black painted steel Setscrew: blacksteel igus ® strap clip stainless steel*: bare-metal, material 1.4301Setscrew: bare-metal, material 1.4301 Press trough, doubletrough and mating trough: igumid GStrain relief devicesTel. +49-2203-96 49-0Fax +49-2203-96 49-222Tensile strength test example with cable Ø 10.5 mmTiewrap plate 2070ZB with a cable tiewrapResult: Tensile strength 290 NChainfix clip CFC-12-MResult: Tensile strength 350 NPull force test for igus ® tiewrap plateswith cable tiewrapsResults: Two tiewraps are more stable than one tiewrap.If one cable tiewrap is used, the breaking force is (approx.) 350 N.If the cable is secured with two cable tiewraps, the breaking forceincreases to 830 N, i.e. pull force resistance more than doubles whenusing two cable tiewraps.Technical data:Tiewrap plates: 2100.ZB/3100.ZBCable: CF1.07.12Cable tiewraps: CFB.001441


Chainfixigus ® Chainfix Strain Reliefigus ® Energy Chain Systems ®If the E-Chains ® glide on themselvesover long travels, the screwheads of the strain relief must beat least 10 mm away from theupper edge of the E-Chains ® atthe fixed end of the chain.This restriction means that thestrain relief elements describedhere may possibly not be able tobe used on the fixed end of longE-Chains ® .Please note our clamps developedspecifically for a low overall height.In the case of unsupported E-Chains ® , the strain relief elementsmay be used with no problems.The dimensions given for H in the tables are based on the maximum cable diameter.The use of thinner <strong>cables</strong> can result in deviating dimensions.Single clamp housing, including top/bottom saddle clampsSteel Stainless steelclamp clampPart No. Part No. ø [mm] B HCFX12.1 CFX12.1.E 06 – 12 16 58CFX14.1 CFX14.1.E 12 – 14 18 50CFX16.1 CFX16.1.E 14 – 16 20 52CFX18.1 CFX18.1.E 16 – 18 22 54CFX20.1 CFX20.1.E 18 – 20 24 56CFX22.1 CFX22.1.E 20 – 22 26 58CFX26.1 CFX26.1.E 22 – 26 30 67CFX30.1 CFX30.1.E 26 – 30 34 71CFX34.1 CFX34.1.E 30 – 34 38 75CFX38.1 CFX38.1.E 34 – 38 42 79CFX42.1 CFX42.1.E 38 – 42 46 83Tel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.deImproved housing foot clampfor easy fit into profile railSetscrew and reduced optimalhousing height for use in long/gliding travel applicationsWhen using Chainfix clampson C-Profile in the mountingbracket for Series 280, 2828,290, 2928, R770, R7728 and ashortened mating trough mustbe used. The Part No. for thisis: CFX...K (add letter "K" to theabove Part No.)* Material stainless steel: 1.4301Double clamp housing, including top/bottomsaddle clamps and one stacker saddle clampTriple clamp housing, including top/bottomsaddle clamps and two stacker saddle clampsSteel Stainless steelclamp clampPart No. Part No. ø [mm] B HCFX12.2 CFX12.2.E 06 – 12 16 72CFX14.2 CFX14.2.E 12 – 14 18 74CFX16.2 CFX16.2.E 14 – 16 20 78CFX18.2 CFX18.2.E 16 – 18 22 82CFX20.2 CFX20.2.E 18 – 20 24 86CFX22.2 CFX22.2.E 20 – 22 26 90CFX26.2 CFX26.2.E 22 – 26 30 109CFX30.2 CFX30.2.E 26 – 30 34 117CFX34.2 CFX34.2.E 30 – 34 38 125Steel Stainless steelclamp clampPart No. Part No. ø [mm] B HCFX12.3 – 06 – 12 16 100CFX14.3 – 12 – 14 18 96CFX16.3 – 14 – 16 20 102CFX18.3 – 16 – 18 22 108CFX20.3 – 18 – 20 24 114CFX22.3 – 20 – 22 26 120442


igus ® Chainfix Strain ReliefChainfixBottom saddle clamps for single/double/triple clamphousings as separate part or insertion into C-profilePart No.ø [mm]CG12 06 – 12CG14 12 – 14CG16 14 – 16CG18 16 – 18CG20 18 – 20CG22 20 – 22CG26 22 – 26CG30 26 – 30CG34 30 – 34CG38 34 – 38CG42 38 – 42Stacker saddle clamps for double/triple clamp housingsfor placement between stacked <strong>cables</strong>Part No.ø [mm]CD12 06 – 12CD14 12 – 14CD16 14 – 16CD18 16 – 18CD20 18 – 20CD22 20 – 22CD26 22 – 26CD30 26 – 30CD34 30 – 34Stainless steel* C profile for allclamps, also for assembly in theKMA connection element Series:280, 2828, 28, 380, 3838, 38, 400,4040, 40, 140, 142 and 5050, 50,150,Part No. CF92.42 ..... .E(specify length in mm)Material: stainless steel*Ribbed strain relief saddleclamps withstands increasedpull forces for long-termdurabilityStrain relief devicesTel. +49-2203-96 49-0Fax +49-2203-96 49-222443


ChainfixChainfix – Snap on Solutionsigus ® Energy Chain Systems ®For the followingE-Chains ® :Chainfix Clip for C-profile:For all KMA mounting bracketswith C-profile-option!Chainfix Clip for crossbars:For most E4 andE6 E-Chains ®Chainfix Clip – Modular snap-on strain relief deviceAvailable for all igus ® E-ChainSystems ® with C-profiles and also suitable for assembly in the KMAmounting brackets and Clip-on strain relief for crossbarsCharacteristic features: Series of clamps and bottom parts made of plastic for cable diameters rangingfrom 4 mm to 24 mm Quick assembly without any tools 2 and 3 layers on top of one anotherpossible Each layer can be detached and changed later on High tensile forces in case of singlelayerinstallation, decreasing with the number of layersø Leitung Part No. Part No. A B C[mm] Clamps Bottom Part [mm] [mm] [mm]04 - 08 mm CFC-08-M CFC-08-C 13.0 14.5 3008 - 12 mm CFC-12-M CFC-12-C 24.0 23.7 3612 - 16 mm CFC-16-M CFC-16-C 32.1 32.4 4216 - 20 mm CFC-20-M CFC-20-C 39.1 43.2 4520 - 24 mm CFC-24-M CFC-24-C 50.0 54.0 50Tel. +49-2203-96 49-0Fax +49-2203-96 49-222For the followingE-Chains ® :For all KMA mounting bracketswith C-profile-option!Chainfix NuggetCharacteristic features: Very small strain relief for the fixation of <strong>cables</strong> up to diameter of 20 mmUse: Accessory for all KMA with integrated c-profile Easy to assemble, without any screws andtools Adjustable to every E-Chain ® filling Very small space requirement Easy strain relief due tofixation with pre-assembled cable strapPart No. ø Leitung max. Breite[mm][mm]CFN.20 20 10.8igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.deFor the followingE-Chains ® :For more detailssee table!Strain relief separatorCharacteristic features: Separator with integrated strain relief for the use in the first or last chain linkUse: Individual part for the manufacturing of switchgear cabinets or for the assembly of machinesAccessory for igus ® E-ChainSystems ® Easy to assemble without any screwsPart No. Number For Seriesof teethT2103.Z 2 210E6.29.02Z 2 E6.292020.Z 2 2400/2500262.Z 3 2600/2700444


Chainfix Tiewrap PlatesChainfixOption 1: Chainfix tiewrap plates as individual partsCharacteristic features: As individual component screwed on KMA (plastic metal mounting brackets)Can be plugged in the mounting brackets Use: Individual part for the manufacturing of switchgearcabinets or for the assembly of machines Accessory for igus ® E-ChainSystems ®Series 2000 – Tiewrap plate as individual partSingle tiewrap plateShown assembledTiewrap plate n Number Dim. C Dim. B Center boreof teeth [mm] [mm] (– = no / + = yes)2020.ZB 3 30 15 –2030.ZB 4 40 20 –2040.ZB 5 50 30 –2050.ZB 6 60 40 –2070.ZB 8 80 60 –2090.ZB (= 2030.ZB + 2040.ZB) 9 90 – –2100.ZB 10 100 80 –2125.ZB (= 2050.ZB + 2050.ZB) 12 120 – –For the followingE-Chains ® :Easy Chain ® Series:E200/Z200System E2/000 Series:2400/2500/24502600/2700/2650255System E4 Series:220Strain relief devicesTel. +49-2203-96 49-0Fax +49-2203-96 49-222Cable tiewraps Width x length Max. Pull force resistance(100-piece bag) [mm] ØCFB.001 4.8 x 150 36 222 NSeries 3000 – Tiewrap plate as individual partSingle tiewrap plateShown assembledTiewrap plate n Number Dim. C Dim. B Center boreof teeth [mm] [mm] (– = no / + = yes)3050.ZB 05 – 50 30 –3075.ZB 07 – 75 55 –3100.ZB 10 – 100 80 –3115.ZB 11 – 115 95 –3125.ZB 12 – 125 105 –3150.ZB 15 – 150 130 –3175.ZB 17 – 175 155 –3200.ZB 20 90 200 180 +3225.ZB 22 102.5 225 205 +3250.ZB 25 115 250 230 +For the followingE-Chains ® :Easy Chain ® Series:E26/Z26E300/Z300System E2/000 Series:2600/2700/26503400/3500/3450System E4 Series:280/290380/390400/4102828/29283838/39384040/41401640Cable tiewraps Width x length Max. Pull force resistance(100-piece bag) [mm] ØCFB.001 4,8 x 150 36 222N445


ChainfixChainfix Tiewrap Platesigus ® Energy Chain Systems ®For the followingE-Chains ® :For all mounting brackets withC-Profil-optionFor the followingE-Chains ® :System E2/000 Series:For more details see table!Option 2: Tiewrap plates with clip-on connection for the C-profileCharacteristic features: Can be plugged into the KMA c-profile Easy solvable with screwdriverEasy to assemble without any screws. Easy solvable with screwdriver nevertheless safe stop Use:Individual part for the manufacturing of switchgear cabinets or for the assembly of machines Accessoryfor igus ® E-ChainSystems ® For all E-Chains ® with KMA and integrated C-profilePart No. Width Number[mm]of teeth3050.ZC 50 53075.ZC 75 7Option 3: Clip-on tiewrap plates for opening or fixed crossbarsCharacteristic features: Can be plugged on the fixed crossbars In case of many harnessed <strong>cables</strong>with strain relief "over two floors" If the KMA is too small for the c-profile Easy to assemble withoutany screws Use: Individual part for the manufacturing of switchgear cabinets or for the assemblyof machines Accessory for igus ® E-ChainSystems ®Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Part No. Width Number For Seriesfixed crossbar [mm] of teeth2050.Z 60 6 2600/27003050.Z 50 5 3400/3500Part 3075.Z No. Width 74 Number 7 For 3400/3500 Seriesopening crossbar [mm] of teeth3035.ZS 35 3 3400/35003050.ZS 50 5 3400/35003075.ZS 75 7 3400/35003850.ZS 48 5 2828/280/38/3838/380/E6.62/142/142404550.ZS 48 5 4040/400/50/5050/E6,80/140/14040/ 150504575.ZS 74 7 4040/400/50/5050/E6,80/140/14040/ 15050igus ® GmbH51147 Köln, GermanyFor the followingE-Tubes:System E2 Tubes Series:R58 R68Option 4: Integrated strain relief for E2 Tubes - Series RCharacteristic features: Strain relief disappears completely in the E-Tube Easy to assemble withoutany screws Use: Individual part for the manufacturing of switchgear cabinets or for the assemblyof machines Accessory for igus ® E-ChainSystems ®Part No. Width Number For Series[mm]of teeth3050.Z 50 6 R683075.Z 75 7 R685850.Z 47 4 R58www.igus.euinfo@igus.de446


Chainfix Strain Relief BlockChainfixigus ® Strain Relief Block for Small Hoses and CablesModular system for great adaptabilityNo hose damageEasy installation - pressing the hose into the locating notch provides reliable fastening without hardwareStrain relief devicesHoses and <strong>cables</strong> can be installed together in the same E-Chain ®Accommodation of hose diameters from 4,3 to 14 mmThe Modular Elements of the igus ® Strain Relief Block for HosesThe modules accommodate hoses from 4,3 to 14 mm, 3 x 4,3 mm hoses can be fitted on top of each inmodule CFS 4.3 and 2 hoses can be fitted directly on top of each other in one notch using module CFS 6.The modules have a width of 27,5 mm, are inserted into the base plate and then fastened in position withM4 countersunk-head screws. The exception is module CFS 55.9 which offers the capacity for 5 x 9 mmhoses with twice the width. The base plate and cover plate are available in widths ranging from 75 to 240 mm.The height of the spacers and modules is 16 mm. Several layers can be installed directly above one another.Cover plateTel. +49-2203-96 49-0Fax +49-2203-96 49-222SpacersGrid-dimensioned modulesW = 27,5 mm H = 16 mmBase platePart No. Hose Number WidthStrain Relief Block Ø [mm] of hoses [mm]CFS 4.3 4,3 4 - 12 27,5CFS 6 6,0 3 - 6 27,5CFS 9 9,0 2 27,5CFS 55.9 9,0 5 55,0CFS 10 10,0 2 27,5CFS 14 14,0 1 27,5Part No.WidthBase plate[mm]CFSU 75.0CFSU 102,5CFSU 130,0CFSU 185,0CFSU 212,0CFSU 240,0Part No.WidthSpacerØ [mm]CFSD 16,0CFSD 12,0Part No.WidthCover plate[mm]CFSP 75,0CFSP 102,5CFSP 130,0CFSP 185,0CFSP 212,0CFSP 240,0447


VAKAT


ReadyChains ®Ready-madeEnergy ChainSystems ®...all inclusive.eadyChain®


Increase cash flowIncrease your cash-flow easily andsmoothly even from batch size 1.Reduce storage costs for<strong>cables</strong>, Energy Chains ®and plugs to zeroYou can do without storage of high flexible <strong>cables</strong>,plugs and any other add-on pieces due to ourrapid and guarantied delivery times.Cut stocking cost tozero for <strong>cables</strong>, E-Chainsand connectors®MinimizedowntimeReduce throughputtime by about 50%Increaseyourcash-flowReduce number ofsuppliers and purchaseordes by about 75%Respond flexiblyto orderfluctuationSplit in half flow timesBecause of a polished logistic igus ® delivers readymadesystems almost worldwide within 2-8 dayson the guarantied date.React flexible tocontract fluctuationsWith ReadyChains ® you are always prepared forcyclical ups and downs. In this field you can passthe buck of capacity fluctuations to us.Minimize machine breakdownPlay it safe, it’s the little things that always causeproblems. Buying numerous single parts not onlyincreases the risk of failure of your plants, it alsocomplicates trouble shooting.You will get a system solution with ReadyChains ® .Any system is checked in our test centre. igus ®is standardized according to ISO 9001.Reduce the numberof suppliers and ordersabout 75%One order one invoice one deliveryone partner. Don’t care about lookingfor numerous parts from numerous suppliers.We have the knowledge to provide you quicklywith the optimal parts.+++++ We are professionals for Energy Chain ® harnessing ++++++450


Degree of harnessingYou determinethe degree of harnessingWe harness from simple Energy ChainSystems ® with inserted <strong>Chainflex</strong> ® <strong>cables</strong> tocomplex systems. These systems may includeall <strong>cables</strong> and hoses (pneumatic, hydraulic),patch plugs, inner partitions, connectingelements and connecting parts as requested.From easy......to the projectAny size is possibleYou determine the sizeAny size is possible. Because of our up-todateproduction processes we can deliver fastand cheap custom-build or serial productionproducts.From batch size 1......to serial productionChoosing the travelYou determine the travelReadyChains ® offers the whole spectrum ofpossible travels of the igus ® Energy Chains ® .We harness anything from ex tremely short tolong travels. Safe transpor tation guaranteesdamage-free delivery of all lengths.From short......to long+++++ We are professionals for Energy Chain ® harnessing +++++451


igus ® ReadyChain ®Increase cash-flow,reduce ordering and flow timesComponent part solutionOrder, component partsDifferent suppliersDifferent delivery periodsReadyChain ® -solutionChain, cable, harnessingOrdering the structural componentwith an article numberGoods received, structural componentsTransport to stockOutgoing stocksGoods received, structural componentTransport to the machineand assembly - "ready for occupation"Pre-mountingTransport to machines, assembly andfitting of the component partsTextile machine, more than 50modifications, delivered to thebelt with three days of leadingtime.Building machines, harnessedhydraulic hoses and fittings.Crane travel up to 100 m,assem bling from the roll.Robots, inclusive media hosesand add-on pieces.++++ We are professionals for Energy Chain ® harnessing +++++ +452


ReadyChain ® delivery timesReadyChain ® BasicConsists of igus ® Energy Chains ® with insertedigus ® <strong>Chainflex</strong> ® <strong>cables</strong> and all necessary componentssuch as separators and connectingelements.Time of delivery:1 – 3 days(after telephonic clarification)ReadyChain ® StandardConsists of "basic", additionally with all patchplugs and connecting elements for igus ® EnergyChains ® and igus ® <strong>Chainflex</strong> ® <strong>cables</strong>.Time of delivery:3 - 5 daysReadyChain ® PremiumConsists of "standard", additionally with all patchplugs and connecting elements for igus ® <strong>cables</strong>,especially designed for the interface of themachine.Time of delivery:3 - 10 days+++++ We are professionals for Energy Chain ® harnessing +++++453


ReadyChain®FactoryLongstanding experience with harnessing of Energy Chains ®igus ® Factory in Cologne:Harnessing of Energy Chains ® since 1994All-automatic crimp machines guaranteesafe connections, rationally connectedComputer-aided high-voltage testingpositions ensure tested qualityNon-spinning cable handlingfor more safetyThe all-automatic break down facilityallows cheap prices for highest quality++++ We are professionals for Energy Chain ® harnessing +++++ +454


ReadyChain®FactoryFor our customers: follow-up of order by web camMore than 50 ReadyChain ® specialists use up-to-date machines for quick planning, harnessing and final inspection ofyour ReadyChain ® Energy Chain System ® . Go and see for yourself: www.readychain.eu70.000 Energy Chain ® components on stock More than 950 <strong>Chainflex</strong> ® Special <strong>cables</strong> for Energy Chains ®are available for you ex stock: www.chainflex.euMore than 2.500 electrical components for patch plugs – avail -able right away from the all-automatic high-bay warehouseMany thousand on time deliveriesin customer specific transport facilities+++++ We are professionals for Energy Chain ® harnessing +++++455


ApplicationsExamples for successful applications with ReadyChain ®igus ® ReadyChain ® used for GEORG disposal vehicle -tested quality among hard conditionsigus ® ReadyChain ® used for travel axles for 6-axlesrobots – standard filling with additional optionsigus ® ReadyChain ® for plastic processing machines –perfect filling for high service lifeigus ® ReadyChain ® with industry patch plugs –faster starting-up, simple assemblingigus ® ReadyChain ® used for a zigzag application of anillumination cross arm, Royal Opera, Londonigus ® ReadyChain ® used for terotechnology –serial applications with different travels++++ We are professionals for Energy Chain ® harnessing +++++ +456


AssemblyAt home or abroad – igus ® assembles the ReadyChains ®The larger the building site, the more inscru -table is the team play of general business -man, subcontractors, erectors of industrialplants and individual craftsman which are parti -cipating to provide the overall performance.Today the installation of an Energy ChainSystem ® for the use of high-grade plants oftenneed more than 100 m travel and/or massesof several tons.for you "ready for occupancy”The following factors rapidly increase costsof the plant to non-calculated amounts:● Replacement of parts● Additional costs for assembly● Costly waiting period● Deadline pressure for follow-up work● Loss of production in case ofexceeding deadlinesTo contribute to the increasing complexityof the installation we lately offer assemblyand pre-harnessing.igus ® ReadyChains ® ready to assemble "from the roll"As a system supplier we can yield all ne -cessary performances until starting up fromthe first to the last maneuverable point. Onlythe electrical connection and the involvedentire starting up need to be done by atechnical engineer.Ask for "ready for occupancy" EnergyChain Systems ® at igus ® .Treasure Island Energy Chain Systems ® under water with on-site assembly+++++ We are professionals for Energy Chain ® harnessing +++++457


PlanningReduce your planning expensesReduce your planning expenses. We relieveyou from as much work as possible. Ourtrained staff will step by step support asmooth realization of your ReadyChain ®project.We can answer many of your questions already on the Tele -phone and demonstrate all advantages of ReadyChain ® foryour business Tel. +49-2203-96 49-0We collect on-site all necessary data for the purpose ofprecise planning expenses. At the same time we go intoyour specific application.igus ® staff at the"on-site inspection" of a plantPlanning with well thought-outforms and special softwareWe can submita complex offer within a weekDrawing updetailed design worksheetsPrecise job and groupingof <strong>cables</strong> planning for each cable++++ We are professionals for Energy Chain ® harnessing +++++458


Designing


<strong>Chainflex</strong> ®PageTechnical Data and Schedules/user information/contact 460Designing with igus ®Cables and Hoses – General rules for <strong>cables</strong> and hoses in Energy Chains ® 462Cables and Hoses – Separation in Energy Chains ® 463Cables and Hoses – Further information on the separation of <strong>cables</strong> 464Electrical Round Cables 465Electrical Round Cables – Information on assembly and strain relief of electrical round <strong>cables</strong> 466Pneumatic hoses 467Data and SchedulesDIN 47100 colour code/Copper wire dimensions according to Anglo-American AWG numbers 468Calculation of the copper surcharge 469Load-Carrying Capacity of Cables 469Electrotechnical data 470Chemical resistance 476InformationsThe General Conditions 478User information, Disclaimer, KTG, Product illustrations 478Technical notes 478Approbation and Approvals 479Configure and order <strong>cables</strong> online, igus ® & eplan 480More igus ® products 482igus ® at www.igus.eu 483According to industries 484Table of contents according to part number 492Contact igus ®Fax – Customer-specific <strong>cables</strong> for Energy Chain Systems ® 488Fax – System Planning 489Fax – Harnessing 490Fax – Order 491igus ® worldwide 500Give us your oppinion – Catalogue improvementDefinition of the icons used in the catalogueCover (back)Cover (back)<strong>Chainflex</strong> ® <strong>cables</strong> classificationCover (ahead)461


Designingwith igus ®Designing the Filling Cables and HosesGeneral rules for <strong>cables</strong> and hoses in Energy Chains ®Rules for:● Maximumcable diameter● Separation● Bending radiusData and energy supply in all forms – in an Energy Chain System ®That is the big advantage of an igus ® Energy Chain System ® : You can safely accommodatemany different forms of data <strong>cables</strong> and energy carriers in a system. It remains up to you,however, to decide how strictly you want to apply your rules to separating and subdividingvarious media. You can, for example, comply with the minimum separating distances betweenbus <strong>cables</strong> and power <strong>cables</strong> and mix any pneumatic, electrical and hydraulic systems.Complete the fax form on page 480of the catalog – and receive yourfinished project suggestion in a fewhours!In addition to the quality of the <strong>cables</strong> being used,the arrangement of a cable within a chain as wellas the space conditions. Many different separationvariants make it possible to adapt theEnergy Chains ® to suit the specific requirementsof each application. Generalized rules such as"No more than 80% of the clear space of EnergyChains ® is allowed to be used" no longer makesense given the complexity of present-dayapplications. In this chapter, we will attemptto give you detailed recommendations. Due tothe large number of application variants, werecommend that you use our free planningservice in any case. Specify your requested<strong>cables</strong> – or also only the demanded electricalor other output data – and you will then receivethe recommendation we have worked out foryou.Fax form on page 480 + Internet questionnaireat www.igus.eu or simply give us a telephonecall. Within a few hours, you will be holdinga detailed system suggestion in your hands.Hydraulic and electrical systems (in closedsection) are separated from one other inthis example.Maximum cable diameterElectrical <strong>cables</strong> require at least 10%of reserve space "all-round", hydraulichoses 20%The maximum cable diameter is specifiedfor each series in the relevantchapterThe maximum cable diameter corresponds tothe clear height of the selected Energy Chains ® /energy tubes minus the reserve space. Thisminimum reserve space, for example, amountsto 10% for electrical round <strong>cables</strong>, and 20% forhydraulic hoses. Energy Chains ® are ideally filledwhen a lateral minimum separating distance tothe next cable or wall is provided. Depending onthe structure of the <strong>cables</strong> and the dynamics andthe service life, extra reserve space must beprovided in addition. In cases of exception, thefilling can also be designed to meet more confinedspace requirements.Please discuss this subject with us.Perfectly installed <strong>cables</strong> with igus ® interiorseparation462


Designing the Filling Cables and HosesDesigningwith igus ®Separation in Energy Chains ®● Cables with extremely varying diametersshould be installed so that they are separatedfrom one another. The separation isprovided by means of separators.● Cables must never have the possibility ofbeing able to push themselves over oneanother. This is why the clear height of acompartment with several equally thick<strong>cables</strong> lying next to one another mustnever amount to more than the cablediameter plus 50%.D1 + D2 > 1.2 x hid1 + d2 ≤ 1.2 x hiDesigningExpressed in rules, this means:Rule 1:If D1 + D2 > 1.2 x chain inner height, noseparation must be made between the two<strong>cables</strong>. Two <strong>cables</strong> should never be allowed tolie on top of one another in unguided form orbecome tangled.Rule 2:If d1 + d2 ≤ 1.2 x chain inner height, a separatoror a modular compartment bottom mustbe installed in order to reduce the inner height.This is done in order to prevent d1 and d2from becoming "mixed up".d1 + d2 ≤ 1.2 x hiTel. +49-2203-96 49-0Fax +49-2203-96 49-222The reason for these rules is:The <strong>cables</strong> must be installed and fastened sothat they can move freely in longitudinaldirection at any time and do not exert anytensile force in the radius on the EnergyChains ® .In case of applications with high travel velocitiesand many load cycles, no <strong>cables</strong> are allowed tobe placed on top of one another without ahorizontal separation.The guidance values for these applications are:Travel velocity exceeding 0,5 m/s and loadcycles exceeding 10.000 p.a.The igus ® interior separation offers a reliablesolution for these applications.Reserve space "all-round" for electrical round <strong>cables</strong>Reserve space capacities in %for various <strong>cables</strong>CablesReserve space"all-round"Electrical round <strong>cables</strong> 10 %Electrical flat <strong>cables</strong> 10 %Pneumatics 5 -10%Hydraulics 20 %Media hoses 15 - 20 %463


Designingwith igus ®Designing the Filling Cables and HosesFurther informationon the separation of <strong>cables</strong>igus ® EnergyChain Systems ®Tel. +49-2203-96 49-0Fax +49-2203-96 49-222● The cable weight should be distributedsymmetrically across the width of the chain.● In the case of <strong>cables</strong> with different externaljackets, it is important to make sure thatthey do not become "stuck together". Ifappropriate, they may have to be installedseparately. igus ® <strong>Chainflex</strong> ® <strong>cables</strong> of allthe series can be combined with oneanother.● The <strong>cables</strong> should always be fastened witha strain relief device at the fixed end and atthe moving end. Exceptions are only to befound in the case of some hydraulic hoseswith length compensation or in the case ofother high-pressure hoses. (see "Hydraulichoses")● Generally speaking, the following applies:The faster and more frequently the EnergyChains ® travel, the more important theprecise assignment of the <strong>cables</strong> in thechain will be. Due to the large number ofvariants, we will gladly advise you withyour specific application.The igus ® kit of Energy Chain Systems ® solves all the require -ments for interior separation known todayBending radius Rigus ® GmbH51147 Köln, Germany● The bending radius of your Energy Chains ®is a factor of the "thickest" or "stiffest" cableor hose in your filling.● The bending radius of the Energy Chains ®should be adapted to suit the recommen -dations of the cable manufacturer. Theselection of bending radius greater than theminimum bending radius has a positiveeffect on the service life to be expected.● The specification of minimum bending radiiin the case of <strong>cables</strong> applies to service useat normal temperatures. The use of otherbending radii may therefore be advisable.Please ask your cable supplier.igus ® <strong>Chainflex</strong> ® <strong>cables</strong> also allow for minimum bending radiiof 5 x d together with millions of strokes.The igus ® product range offers up to 12 different bendingradii for each chain series from stock. Here series 50 in theStorebaelt bridge project.www.igus.euinfo@igus.deWe will be glad to give you our recommendations for a complete Energy Chain System ® . The bending radii of all<strong>cables</strong> and hoses, interior separation and service life are then perfectly adapted to suit one another in the bestpossible way. Also ask us about the igus ® system guarantee. Harnessing, from page 449 onwards464


Designing the Filling Electrical Round CablesDesigningwith igus ®Electrical round <strong>cables</strong>In the case of electrical <strong>cables</strong>, the round cable is a reliable, modular and low-cost solution for Energy Chain Systems ® .For your purchase, we recommend that you consider the following criteria:Selection criteria:● Small minimum bending radii and mountingheights● Service life with minimum bending radius● Service life for your application case, e.g.short or long distance of travel or suspendedinstallation use● Test values for the service life based onpractice-oriented experiments● Uncomplicated handling during assembly,e.g. no detaching, laying out, etc.● Strain relief device on the connection elementshould be possible● Bending-resistant shields in the case ofshielded <strong>cables</strong>● Abrasion-resistant, readily gliding externaljackets● Large selection in order to avoid expensiveproduction of single productsExample igus ® experimental laboratory: constant developmentand testing of <strong>Chainflex</strong> ® electrical round <strong>cables</strong>DesigningTel. +49-2203-96 49-0Fax +49-2203-96 49-222In the case of bus <strong>cables</strong> and fibre-optic <strong>cables</strong>,it is especially important to consider how wellthe transmission rates and the shielding effectsare maintained after several million strokes inthe minimum bending radius.465


Designingwith igus ®Designing the Filling Electrical round <strong>cables</strong>igus ® EnergyChain Systems ®Tel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® GmbH51147 Köln, GermanyInformation on assembly and strain relief of electrical round <strong>cables</strong>1. The <strong>cables</strong> must be installed twist-free.Drums or rings are not allowed to bepulled off across the top. igus ® <strong>Chainflex</strong> ®<strong>cables</strong> are ready to be laid immediately.They do not need to be detached or laidout prior to the assembly procedure.2. The <strong>cables</strong> must be laid so that eachindividual cable can move freely in longi -tudinal direction.3. The <strong>cables</strong> must be able to move freelyin the radius. This must be checked whenthe upper section reaches the biggestclear length.4. The separation of the interior space bymeans of separators or by means of theigus ® interior separation system is requiredwhenever several or many <strong>cables</strong> withdifferent diameters are being installed.It is important to make sure that the<strong>cables</strong> cannot wrap themselves aroundone another in spiral form.5. In the case of <strong>cables</strong> with differentexternal jackets, it is important to makesure that they do not become "stucktogether". If appropriate, they may needto be separated. igus ® <strong>Chainflex</strong> ® <strong>cables</strong>of all the series can be combined withone another.6. Electrical round <strong>cables</strong> must be fastenedin strain-relieved form on both sides. Incases of exception, the <strong>cables</strong> must atleast be fastened in strain-relieved format the moving end of the Energy Chains ® .A separating distance of 10-30 x cablediameter is recommended for most <strong>cables</strong>.<strong>Chainflex</strong> ® <strong>cables</strong>, however, can bestrain-relieved directly at the connectionelement, as confirmed by many seriesof tests.Correct!Wrong!Wrong!Cables must be able to move freely in the radiusWe will be glad to make you an offer on ourready-made Energy Chain Systems ® :"ReadyChain ® : chain, cable, harnessing".<strong>Chainflex</strong> ® <strong>cables</strong> can be strain-relieved directly at theconnection element.Harnessing, from page 449 onwardswww.igus.euinfo@igus.deCorkscrewing: An imperfectly matched system can result inthese failures.466


Design InformationDesigningwith igus ®Pneumatic hosesBasically, the same rules that apply to round<strong>cables</strong> also apply to pneumatic hoses. In practice,how ever, it can be seen that pneumatic hosesare less susceptible to malfunctions. Followingproper con sultation, they can also be laid to meetmore confined space requirements than is providedfor by the "10% reserve space all-round"rule. A strain relief device on both sides is usuallythe case here as well. In the case of pneumatichoses made of rubber, we recommend strictcompliance with the "10% reserve space" rulebecause these hoses tend to become "stucktogether" among one another or with other Completely ready-made Energy Chain<strong>cables</strong>.System ® with several pneumatic hosesnext to and on top of one another.The igus ® product range also offers thermoplastic pneumatic hoses "<strong>Chainflex</strong> ® CFAIR".Page 212DesigningTel. +49-2203-96 49-0Fax +49-2203-96 49-222467


DataandSchedulesSpecial Cables Information Colour Code + Copper PriceDIN 47100 colour code (however, deviating from DIN:without colour repetition after 44th core)*<strong>Chainflex</strong> ®1 white2 brown3 green4 yellow5 gray6 pink7 blue8 red9 black10 violet11 gray-pink12 red-blue13 white-green14 brown-green15 white-yellow16 yellow-brown17 white-gray18 gray-brown19 white-pink20 pink-brown21 white-blue22 brown-blue23 white-red24 brown-red25 white-black26 brown-black27 gray-green28 yellow-gray29 pink-green30 yellow-pink31 green-blue32 yellow-blue33 green-red34 yellow-red35 green-black36 yellow-black37 gray-blue38 pink-blue39 gray-red40 pink-red41 gray-black42 pink-black43 blue-black44 red-black45 white-brown-black46 yellow-green-black47 gray-pink-black48 red-blue-black49 white-green-black50 brown-green-black51 white-yellow-black52 yellow-brown-black53 white-gray-black54 gray-brown-black55 white-pink-black56 pink-brown-black57 white-blue-black58 brown-blue-black59 white-red-black60 brown-red-black61 black-white* Exception: 4-core <strong>cables</strong> are braided in the colour sequence white, green, brown, yellow.The first colour indicates the basic colour of the core insulation, and the second colour indicates the colour of the printedonring. In the case of three colours, the second and colours are printed on the basic colour.Tel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.de468Calculation of the copper surchargeThe copper surcharge is the calculation of the difference betweenthe calculated price (copper basis) and the fluctuating,actual price of the copper share in a cable. In calculatory terms,the list price of each <strong>Chainflex</strong> ® cable is based on a copperprice to the amount of € 150,-/100 kg of copper. In the end,however, this copper share is calculated on the basis of thecurrent daily price according to the DEL (German abbr. = Germanelectrolyte copper for conducting purposes) quotation.Copper index [kg/km] x DEL quotation [ €/100 kg] – Copper basis [ €/100 kg] = Copper surcharge [€/km]100260 x 189 – 150 = Copper surcharge [€/km]100Copper surcharge = 101,40 €/kmThe copper index specifies the weight of the copper share in acable in kg/km. The product from the copper index (kg/km) andthe price difference per kg of copper according to the DEL quo -tation then provides the copper surcharge in € per km of cable.Here, the following example:Cable:<strong>Chainflex</strong> ® CF9.15.18Copper index: 260 kg/kmDEL quotation: € 189,–/100 kg CuCopper basis: € 150,–/100 kg CuFor this example, the copper surcharge amounts to € 101.40/km of cable. Any discounts that are granted only applyto the cable prices but not to the copper surcharge. The copper surcharge is shown separately on our invoices.New: You now have the possibility of calculating the individual extra charge for copper for your cable on-linewww.igus.eu/en/cfcuCopper wire dimensions according to Anglo-American AWG numbersAWG Diameter Cross sectionNo. mm mm 2500 17,96 253,00350 15,03 177,00250 12,70 127,004/0 11,88 107,203/0 10,40 85,002/0 9,27 67,501/0 8,25 53,501 7,35 42,402 6,54 33,604 5,19 21,206 4,12 13,308 3,26 8,3710 2,59 5,2612 2,05 3,3114 1,63 2,0816 1,29 1,31AWG Diameter Cross sectionNo. mm mm 218 1,024 0,82320 0,813 0,51922 0,643 0,32424 0,511 0,20526 0,405 0,12828 0,320 0,080430 0,255 0,050732 0,203 0,032434 0,160 0,020036 0,127 0,012738 0,102 0,0081140 0,079 0,0048742 0,064 0,0031744 0,051 0,00203


Special Cables Information Load-Carrying Capacity of CablesDataandSchedulesThe values from the tables on the side of this page havebeen taken from the standard DIN VDE 0298, Part 4.These values have been simplified and only applyapproxi mately. For each user, it is advisable to obtainand comply with the regulations that apply to each individualcase of application (e.g. measures for protectionin case of indirect contact in accordance with DINVDE 0100 Part 410, overcurrent protective devices inaccordance with DIN VDE 0100 Part 430 or voltagedrop in accordance with DIN VDE 0100 Part 520). It isnot possible to provide all the regulations or overviewsin this catalog. Due to the harmonization that has beencarried out, it is possible that different load-carryingvalues may be permissible for the same cable in somecases. For the selection of the relevant cross sections,the load capacity in undisturbed operation is the determiningfactor, i.e. the use with permissible operatingtemperature or permissible maximum temperature onthe conductor.The load-bearing capacity according to Table 1 on thispage applies to operating-current-carrying conductors.Normally, these are 2 loaded conductors in the caseof 2-core and 3-core <strong>cables</strong>, as well as 3 loaded conductorsin the case of 4-core and 5-core <strong>cables</strong>. Pleasetake this into account when planning for the use ofmulti-core <strong>cables</strong> in electrical installation conduits orEnergy Chains ® . This information is based on an ambienttemperature of 30°C and a non-loaded cable. Pleaseapply the conversion factors according to Table 2 incase the air temperature is increased due to the heatloss of the <strong>cables</strong> (please take thermal radiation intoaccount as well, e.g. effects of exposure to the sun).The possible cable installation types in Energy Chains ®result in such a broad range of loading profiles that nogeneralized conversion factors can be mentioned forthis large accumulation of <strong>cables</strong>. The installation typeand the conversion factors must be looked up in Table3 according to each individual application.Table 1: Cables for fixed installation in energy-conductingchains and tubesInsulation PVC TPEmaterial<strong>Chainflex</strong> ® typeNumber of cores 2 or 3InstallationCF5, CF6, CF2,CF211(D)CF130.UL, CF140.UL,CF77.UL.D, CF78.UL, CF9,CF10, CF9.UL, CF10.UL, CF98,CF99, CF240, CF211, CF112,CF113, CF11, CF12, CF211(M),CF113.D, CF111.D, CF11.D,CF210.UL, CF21.UL,CF270.UL.D, CF27.D, CF30,CF31, CF34.UL.D, CF35.UL,CF37.D, CF38, CF300.UL.D,CFPE, CF310.UL, CF330.D,CF340, CFBRAID, CFROBOT,CFROBOT 6,7,9Nominal cross section Load-carrying capacity in amperesNominal cross of PVC TPEcopper cable in insulation insulationmm 20,14 2,5 2,50,25 4 50,34 5 70,50 8 100,75 12 141 15 171,50 18 212,50 26 304 34 416 44 5310 61 7416 82 9925 108 13135 135 16250 168 20270 207 25095 250 301120 292 352150 – 404185 – 461Table 2: Conversion factors in case of varying ambienttemperaturesConversion factorAmbient PVC TPEtemperature °C insulation insulation<strong>Chainflex</strong> ®Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Table 3: Conversion factors for multi-core <strong>cables</strong> with cablecross sections up to 10 mm 2Loaded coresConversion factor5 0,757 0,6510 0,5514 0,5019 0,4524 0,4040 0,3561 0,3010 1,22 1,1515 1,17 1,1220 1,12 1,0825 1,06 1,0430 1,00 1,0035 0,94 0,9640 0,87 0,9145 0,79 0,8750 0,71 0,8255 0,61 0,7660 0,50 0,7165 – 0,6570 – 0,5875 – 0,5080 – 0,4185 – 0,2990 – 0,14469


DataandSchedulesSpecial Cables Information Electrotechnical dataThe following tables provide measured values on the electrotechnicaldata of the <strong>cables</strong> available at the time of the survey. Thevalues are understood as being approximate values. For preciseinformation on the actually available <strong>cables</strong>, individual measurementsare absolutely required.The specification of the characteristic wave impedance at high frequenciesin Ω is an important quantity for a reflection-free matchingof <strong>cables</strong>, e.g. in bus systems. With respect to the combination ofvarious <strong>cables</strong> types and lengths, an adaptation must be providedvia a matching resistor.Cable type CF130.UL, Nominal cross section * 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8Loop capacitance up to 7 cores in nF/km approx. 120 105 110 125 125 140 140Loop capacitance from 12 cores in nF/km approx. 65 65 90Loop inductance in µH/km approx. 635 650 640 620 610 610 565Characteristic wave impedance at 1 kHz in Ω 80 90 90 80 80 70 65Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. 150 190 190 205 210 230Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 150 205Cable type CF140.UL, Nominal cross section * 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8Loop capacitance up to 7 cores in nF/km approx. 125 125 140 140 165 190Loop capacitance from 12 cores in nF/km approx. 75 90 90Loop inductance in µH/km approx. 650 650 630 630 620 620Characteristic wave impedance at 1 kHz in Ω 80 80 80 75 70 60Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. 310 310 360 370 430 510Capacitance: 2 cores versus all others up to 12 cores in nF/km approx.Cable type CF5, Nominal cross section * 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8Loop capacitance up to 7 cores in nF/km approx. 95 115 135 185 125Loop capacitance from 12 cores in nF/km approx. 120 90 105 105 135 670Loop inductance in µH/km approx. 760 720 670 670 640 150Characteristic wave impedance at 1 kHz in Ω 85 85 80 80 65Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. 165 190 210 460Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 325 207 225 230 330Cable type CF6, Nominal cross section * 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8Loop capacitance up to 7 cores in nF/km approx. 130 125 135 150 165 185Loop capacitance from 12 cores in nF/km approx. 110 120 120 135Loop inductance in µH/km approx. 725 700 690 680 640 640Characteristic wave impedance at 1 kHz in Ω 80 80 80 75 70 65Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. 340 340 340 400 420 460Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 275 275 290 330Cable type CF2, Nominal cross section * 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8Loop capacitance up to 7 cores in nF/km approx. 110 130 110 110 135Loop capacitance from 12 cores in nF/km approx. 100 120 130 105 135Loop inductance in µH/km approx. 690 630 740 730 670Characteristic wave impedance at 1 kHz in Ω 90 80 85 85 75Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. 280 305 320 320 370Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 230 270 300 260 330* The following values are approximate values, calculated from measurements of <strong>cables</strong> with different numbers of cores. The loop resistance can be maximally 5% over the specifiedvalue for <strong>cables</strong> that are very lavishly stranded in bundles (from 12 cores).470


Special Cables Information Electrotechnical dataDataandSchedulesCable type CF9, Nominal cross section * 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8 2.6Loop capacitance up to 7 cores in nF/km approx. 70 75 85 85 95 100 125 120 100 130Loop capacitance from 12 cores in nF/km approx. 80 90 100 105 120 130Loop inductance in µH/km approx. 670 650 650 620 590 560 560 600 520 530Characteristic wave impedance at 1 kHz in Ω 100 100 90 85 80 75 70 70 70 65Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. 115 135 135 145 145 170 190 150 185 200Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 200 185 255 235 215 225Cable type CF10, Nominal cross section * 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8Loop capacitance up to 7 cores in nF/km approx. 90 105 110 120 125 150Loop capacitance from 12 cores in nF/km approx. 80 95 95 105 115 120 130Loop inductance in µH/km approx. 680 670 620 590 580 575 555Characteristic wave impedance at 1 kHz in Ω 100 90 85 80 75 75 65Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. 215 245 260 290 290 345Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 180 200 205 225 255 265 275Cable type CF9.UL, Nominal cross section * 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8 2.6Loop capacitance up to 7 cores in nF/km approx. 70 75 85 85 95 100 125 120 100 130Loop capacitance from 12 cores in nF/km approx. 80 90 100 105 120 130Loop inductance in µH/km approx. 670 650 650 620 590 560 560 600 520 530Characteristic wave impedance at 1 kHz in Ω 100 100 90 85 80 75 70 70 70 65Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. 115 135 135 145 145 170 190 150 185 200Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 200 185 255 235 215 225Cable type CF10.UL, Nominal cross section * 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8Loop capacitance up to 7 cores in nF/km approx. 90 105 110 120 125 150Loop capacitance from 12 cores in nF/km approx. 80 95 95 105 115 120 130Loop inductance in µH/km approx. 680 670 620 590 580 575 555Characteristic wave impedance at 1 kHz in Ω 100 90 85 80 75 75 65Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. 215 245 260 290 290 345Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 180 200 205 225 255 265 275Cable type CF98, Nominal cross section 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158Loop capacitance in nF/km approx. 62 75Loop inductance in µH/km approx. 600 565Characteristic wave impedance at 1 kHz in Ω 115 115Capacitance of one core versus all other cores in nF/km approx. 100 120* The following values are approximate values, calculated from measurements of <strong>cables</strong> with different numbers of cores. The loop resistance can be maximally 5% over the specifiedvalue for <strong>cables</strong> that are very lavishly stranded in bundles (from 12 cores).471


DataandSchedulesSpecial Cables Information Electrotechnical dataCable type CF240, Nominal cross section 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114Operating capacity at 1 kHz in nF/km approx. 100 110 120Characteristic wave impedance at 1 kHz in Ω 95 85 80Capacitance: 2 cores versus all others cores and shield in nF/km approx. 240 300 305Cable type CF211, Nominal cross section 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 158 114 78Operating capacity at 10 MHz in nF/km approx. 157 145 125Characteristic wave impedance at 1 kHz in Ω 75 70 80Characteristic wave impedance at 10 MHz in Ω approx. 60 50 60Cable type CF111, Nominal cross section 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 158 114 78Operating capacity at 10 MHz in nF/km approx. 157 145 125Characteristic wave impedance at 1 kHz in Ω 75 70 80Characteristic wave impedance at 10 MHz in Ω approx. 60 50 60Cable type CF11, Nominal cross section 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8Operating capacity at 10 MHz in nF/km approx. 100 110 115 140 145 150 150 180Characteristic wave impedance at 1 kHz in Ω 100 85 85 75 70 65 60 60Characteristic wave impedance at 10 MHz in Ω approx. 70 65 60 50 50 45 45 40Cable type CF12, Nominal cross section 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8Operating capacity at 10 MHz in nF/km approx. 150 165 200Characteristic wave impedance at 1 kHz in Ω 70 70 50Characteristic wave impedance at 10 MHz in Ω approx. 45 45 35Cable type CF113.D, Nominal cross section 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8Operating capacity at 1 kHz in nF/km approx. 55 - 80 65 55 50 - 110Characteristic wave impedance at 1 kHz in Ω 110 105 125 75 - 155Cable type CF111.D, Nominal cross section 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 114 78 52 39 26.6 16 9.9 6.6 3.8Operating capacity at 1 kHz in nF/km approx. (pair shielded) 80 65Operating capacity at 1 kHz in nF/km approx. (pair unshielded) 55 55 80Characteristic wave impedance at 1 kHz in Ω (pair shielded) 105 130Characteristic wave impedance at 1 kHz in Ω (pair unshielded) 115 115 90Cable type CF11.D, Nominal cross section 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 276 158 114 78 52 39 26.6 16 9.9 6.6 3.8Operating capacity at 1 kHz in nF/km approx. 55 - 80 65 55 50 - 110Characteristic wave impedance at 1 kHz in Ω 110 105 125 75 - 155472


Special Cables Information Electrotechnical dataDataandSchedulesCable type CF21.UL, Energy conductor 0,75 1 1,5 2,5 4 6 10 16 25 35 50Single impedance in Ω/km approx. 26 19.5 13.3 7.98 4.95 3.3 1.91 1.21 0.78 0.554 0.386Operating capacity in nF/km approx. 150 165 190 200 225 245 320Operating inductane in µH/km approx. 365 365 350 340 340 340 330Characteristic wave impedance at 1 kHz in Ω 95 95 80 80 70 70 60Capacitance of one core versus all other cores in nF/km approx. 130 140 170 170 200 210 270Cable type CF21.UL, Signal pair 0,34 0,75 1,5Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 114 52 26.6Loop capacitance in nF/km approx. 80 100 130Loop inductance in µH/km approx. 580 600 600Characteristic wave impedance at 1 kHz in Ω 90 80 75Capacitance of one core versus all other cores in nF/km approx. 140 175 240Cable type CF27, Energy conductor 0,75 1 1,5 2,5 4 6 10 16 25 35 50Single impedance in Ω/km approx. 26 19.5 13.3 7.98 4.95 3.3 1.91 1.21 0.78 0.554 0.386Operating capacity in nF/km approx. 170 180 220 220 250 260 285 350 595Operating inductane in µH/km approx. 360 380 355 355 325 310 310 310 310Characteristic wave impedance at 1 kHz in Ω 95 90 80 80 70 70 65 65 45Capacitance of one core versus all other cores in nF/km approx. 145 150 185 185 205 215 240 295 495Cable type CF27, Signal pair 0,5 0,75 1,5Conductor loop consisting of two adjacent cores, aprox.Loop resistance in Ω/km approx. 78 52 26.6Loop capacitance in nF/km approx. 92 100 130Loop inductance in µH/km approx. 650 600 600Characteristic wave impedance at 1 kHz in Ω 90 80 75Capacitance of one core versus all other cores in nF/km approx. 170 175 240473


DataandSchedulesSpecial Cables Information Electrotechnical dataCable type CF30, Nominal cross section 1,5 2,5 4 6 10 16 25 35 50 70Single impedance in Ω/km approx. 13.3 7.98 4.95 3.3 1.91 1.21 0.78 0.554 0.386 0.272Operating capacity in nF/km approx. 145 155 170 170 195 215 220 270Operating inductane in µH/km approx. 330 330 320 320 310 300 295 290Characteristic wave impedance at 1 kHz in Ω 95 95 90 90 80 70 70 65Capacitance of one core versus all other cores in nF/km approx. 110 115 130 130 150 160 170 200Cable type CF31, Nominal cross section 1,5 2,5 4 6 10 16 25 35 50 70Single impedance in Ω/km approx. 13.3 7.98 4.95 3.3 1.91 1.21 0.78 0.554 0.386 0.272Operating capacity in nF/km approx. 190 200 215 235 270 295 300 305 370 500Operating inductane in µH/km approx. 330 330 320 320 310 260 260 260 260 260Characteristic wave impedance at 1 kHz in Ω 85 80 75 70 70 60 60 60 55 50Capacitance of one core versus all other cores in nF/km approx. 170 180 190 210 240 280 250 285 330 440Cable type CF34.UL.D, Nominal cross section 1,5 2,5 4 6 10 16 25 35 50 70Single impedance in Ω/km approx. 13.3 7.98 4.95 3.3 1.91 1.21 0.78 0.554 0.386 0.272Operating capacity in nF/km approx. 120 145 150 200 175Operating inductane in µH/km approx. 340 320 320 310 310Characteristic wave impedance at 1 kHz in Ω 100 95 95 90 90Capacitance of one core versus all other cores in nF/km approx. 90 110 110 140 130Cable type CF35.UL, Nominal cross section 1,5 2,5 4 6 10 16 25 35 50 70Single impedance in Ω/km approx. 13.3 7.98 4.95 3.3 1.91 1.21 0.78 0.554 0.386 0.272Operating capacity in nF/km approx. 160 180 190 215 260Operating inductane in µH/km approx. 330 320 320 310 290Characteristic wave impedance at 1 kHz in Ω 100 85 85 75 70Capacitance of one core versus all other cores in nF/km approx. 140 155 170 190 220474


Special Cables Information Electrotechnical dataDataandSchedulesCable type CF37.D, Nominal cross section 1,5 2,5 4 6 10 16 25 35 50 70Single impedance in Ω/km approx. 13.3 7.98 4.95 3.3 1.91 1.21 0.78 0.554 0.386 0.272Operating capacity in nF/km approx. 120 145 150 200 175Operating inductane in µH/km approx. 340 320 320 310 310Characteristic wave impedance at 1 kHz in Ω 100 95 95 90 90Capacitance of one core versus all other cores in nF/km approx. 90 110 110 140 130Cable type CF38, Nominal cross section 1,5 2,5 4 6 10 16 25 35 50 70Single impedance in Ω/km approx. 13.3 7.98 4.95 3.3 1.91 1.21 0.78 0.554 0.386 0.272Operating capacity in nF/km approx. 160 180 190 215 260Operating inductane in µH/km approx. 330 320 320 310 290Characteristic wave impedance at 1 kHz in Ω 100 85 85 75 70Capacitance of one core versus all other cores in nF/km approx. 140 155 170 190 220Cable type CF300.UL.D, Nominal cross section 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240Resistance in Ω/km approx. 13.3 7.98 4.95 3.3 1.910 1.210 0.780 0.554 0.386 0.272 0.206 0.161 0.129 0.106 0,0801Cable type CF310.UL, Nominal cross section 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240Resistance in Ω/km approx. 13.3 7.98 4.95 3.3 1.910 1.210 0.780 0.554 0.386 0.272 0.206 0.161 0.129 0.106 0,0801Cable type CF330.D, Nominal cross section 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240Resistance in Ω/km approx. 13.3 7.98 4.95 3.3 1.910 1.210 0.780 0.554 0.386 0.272 0.206 0.161 0.129 0.106 0,0801Cable type CF340, Nominal cross section 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240Resistance in Ω/km approx. 13.3 7.98 4.95 3.3 1.910 1.210 0.780 0.554 0.386 0.272 0.206 0.161 0.129 0.106 0,0801475


DataandSchedulesSpecial Cables Information Chemical resistance1 2 3 4Group <strong>Chainflex</strong> ® Jacket material PagecableControl cableControl cable CF130.UL PVC 1 54Control cable CF140.UL PVC 1 58Control cable CF5 PVC 2 62Control cable CF6 PVC 2 66Control cable CF77.UL.D PUR 3 70Control cable CF78.UL PUR 3 72Control cable CF2 PUR 3 74Control cable CF9 TPE 4 78Control cable CF10 TPE 4 82Control cable CF9.UL TPE 4 86Control cable CF10.UL TPE 4 90Control cable CF98 TPE 4 94Control cable CF99 TPE 4 96Data cableData cable CF240 PVC 2 100Data cable CF211 PVC 2 102Data cable CF112 PUR 3 104Data cable CF113 PUR 3 106Data cable CF111 TPE 4 108Data cable CF11 TPE 4 112Data cable CF12 TPE 4 114Bus cableBus cable CFBUS TPE 4 118Bus cable CF11.LC TPE 4 122Bus cable CF11.LC.D TPE 4 124Bus cable CF14 TPE 4 126Measuring system cableMeasuring system cable CF211 PVC 2 128Measuring system cable CF113.D PUR 3 132Measuring system cable CF111.D TPE 4 136Measuring system cable CF11.D TPE 4 140Koax cableKoax cable CFKoax1 TPE 4 144Fibre optic cableFibre optic cable CFLG.2H PUR 3 150Fibre optic cable CFLK PUR 3 152Fibre optic cable CFLG.2LB TPE 4 154Fibre optic cable CFLG.G TPE 4 156Servo cableServo cable CF210.UL PVC 2 160Servo cable CF21.UL PVC 2 162Servo cable CF260 PUR 3 166Servo cable CF27.D PUR 3 170Servo cable CF270.UL.D PUR 3 174Power cablePower cable CF30 PVC 2 180Power cable CF31 PVC 2 182Power cable CF34.UL.D TPE 4 184Power cable CF35.UL TPE 4 186Power cable CF37.D TPE 4 188Power cable CF38 TPE 4 190Power cable CF300.UL.D TPE 4 192Power cable CFPE TPE 4 194Power cable CF310.UL TPE 4 196Power cable CF330.D TPE 4 198Power cable CF340 TPE 4 200Power cable CF BRAID TPE 4 202476


Special Cables Information Chemical resistanceNotesCable type1 2 3 4Inorganic chemicalsAqueous solutions, neutralWaterCommon salt (10%)Glauber's salt (10%)Aqueous solutions, alkalineSoda (10%)Aqueous solutions, acidSodium bisulfate (10%)Aqueous solutions, oxidizingHydrogen peroxide (10%)Potassium permanganate (2%)Inorganic acidsHydrochloric acid, concentratedHydrochloric acid (10%)Sulfuric acid, concentratedSulfuric acid (10%)Nitric acid, concentratedNitric acid (10%)Inorganic caustic solutionsSoda lye, concentratedSoda lye (10%)Potassium lye, concentratedPotassium lye (10%)Ammonia, concentratedAmmonia (10%)Organic chemicals /organic acidsAcetic acid, concentrated (glacial acetic acid)Acetic acid (10% in H 20)Tartaric acid (10% in H 20)Citric acid (10% in H 20)KetonesAcetonesMethyl ethyl ketone (MEK)AlcoholsEthyl alcohol (spirit)Isopropyl alcoholDiethylene glycolAromatic compoundsToluolXylolFuelsGasolineDiesel fuelSynthetic oils /lubricating oilASTM oil #2Hydraulic oilMineral oil baseGlycol baseSynthetic ester baseVegetable oilsRapeseed oilOlive oilSoya bean oilCold cleaning agentCold cleaning agent+ + + ++ + + ++ + + +O + O +O + O ++ + + ++ + + +– – – –O O O +– – – –O O O +– – – –O O – O– – – OO O O +– – – OO O O +O O O ++ + + +– – – OO + O +O + + +O + + +– – – O– – – O– O O +– O O +O O + +– – O –– – O –– O + +– O + +O + + +– O + +O O + +– O + +O + + +O + + +O + + +– O + O+ no or minimum negative influenceO medium reciprocal effect, short-term exposure permissible– unstable, material partly destroyedAll information applies to room temperature477


DataandSchedulesInformation<strong>Chainflex</strong> ®The General ConditionsThe General Conditions of Sale of igus ® shall apply. Excessive and short deliveries of ±10 % for <strong>cables</strong> conform with contractual agreements. Deliveries can be made in partlengths.Statutory VAT must be added to the prices. The General Conditions of Saleand Delivery of igus ® GmbH, Cologne, can be found online under www.igus.de.The prices quoted in the catalogue or other media are subject to alteration. igus ® canmodify the prices at any time at their own discretion.User informationSince our products are constantly being developed further in the interest of our customers,we reserve the right to make technical alterations at any time. With the issue ofthis catalog, all previous publications lose their validity. Subject to printing errors.DisclaimerThe terms "igus", ReadyCable", "ReadyChain", "<strong>Chainflex</strong>", "E-Chain Systems", "EnergyChain", "Energy Chain Systems", "E-Ketten", "E-KettenSysteme", "Flizz", "iglidur","DryLin" are legally protected trademarks in the Federal Republic of Germany and incase also in foreign countries.Tel. +49-2203-96 49-0Fax +49-2203-96 49-222KTGIf cable drums are to be used, please visit KTG directly online.www.kabeltrommel.deProduct illustrationsThe products illustrated are photos showing examples for whole series, i.e. the originalcable can deviate from the cable shown.igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.de478Technical notesThe USB, FireWire and GigE-<strong>cables</strong> shown on these pages were developed for theambitious industrial usage in E-Chains ® . High proofness to oil and lubricants is as securedas protection against electromagnetical interferences. This high mechanical servicelife was reached with the usage of high quality materials which even care for the electricalsafeness.In single cases communication errors can occur, if very different hardwareand software is combined. We recommend tests with all components and the<strong>cables</strong> before starting serial production, to get the proove for a perfect running system.Of course we support you with the details of these electrical tests. Just give us a call!The specifications in the catalogue referring to temperature range, bending radius andtravel must be seen as limiting value specifications. If two limiting value specificationsare combined, this can lead to a reduction of the cable's service life. The term "oilresistant" refers to a few selected oil types which have been tested accordingly. Thisdoes not mean, however, that the products are automatically resistant to all the oils onthe market. Length printing: Respective printing of the metre length is already on many<strong>cables</strong>. These are not calibrated measurements, they are only intended as an orientationaid.Just give us a call!


Special Cables Information Approbation and ApprovalsDataandSchedulesigus ® <strong>Chainflex</strong> ® <strong>cables</strong> for DESINADESINA: DEcentral and Standardised INstAllation technique is a recommendation of theVerein Deutscher Werkzeugmaschinenfabriken (VDW = Association of German machinetool industry) for the purpose of standardising components, interfaces and connectingsystems.DESINA describes an extensive whole concept for standardisation and decentralisationof the fluid technical and electrical installation of machines and plants.For further information: www.desina.de<strong>Chainflex</strong> ®Underwriters Laboratories Inc.For further information: www.ul-europe.comUnderwriters Laboratories Inc.For further information: www.ul-europe.comCanadian Standards AssociationFor further information: www.csa.cawww.igus.euTel. +49-2203-96 49-0Fax +49-2203-96 49-222info@igus.deCommission Électrotechnique InternationaleCommunauté Européenneigus ® GmbH51147 Köln, Germany479


Configure andorder <strong>cables</strong>onlineigus ® provides electronic supportRectangular connectors, Sub D connectors, round connectors – you can nowselect <strong>cables</strong> yourself from your workplace or home PC. Experienced userswill only need about one and a half minutes to assemble the cable they need viathe Internet. The components selected and all available ex-stock can then beplaced in a virtual shopping basket and delivered by igus ® without delay.Filter the optimum cable out and order onlineUsing the QuickCable product finder, available online under www.igus.eu/quickcable,users can first search for the optimum technical solution and then make an onlineinquiry or place an order. Cable selection is via a choice of parameters: electrical,dynamic, mechanical and chemical parameters and environmental questions.Direct cable selection is also possible, of course.Individual pin assignmentOnce the cable type has been found, the new QuickPin configurator is the next step.Under www.igus.eu/quickpin, igus ® offers all its connector types in a convenientmenu, including reason test. The pin or wire contact assignment is flexible, dependingon the user's requirements. The contacts can be assigned logically per mouse click,the pole images are then represented by symbols. This means that instead of a listin a table, the pin assignment can be viewed as an image on one page.Calculate service life onlineCalculate service life online – depending on the parameters travel, bending radiusand speed. The program checks the logical plausibility of the parameters entered.The result is given in the number of double strokes to be expected. If other cabletypes could achieve better results on the basis of the parameters entered, this willbe noted.igus ® &<strong>Chainflex</strong> ® cable library for eplan● The article data of all <strong>Chainflex</strong> ® <strong>cables</strong> are now downloadable in eplan standard!www.igus.eu/eplan-download● Completely created cable type file, including information on colour codes, crosssections,shields, etc.● Cable article file in eplan format for piece lists or order lists● Fully compatible with eplan 5/eplan 8480i-net customer information system available at www.igus.euTrack your order in real time with igus ® i-net. Simply apply for your password, login and you can then track your job status via webcam. You can also use the igus ®i-net carrier tracking system to track your ordered merchandise from the igus ® shippingprocess right up to your front door.● Webcams● More precise order data including an overview of target-actual deadlines● Selection whether you prefer order confirmation or invoice by letter, fax or e-mail


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®481


Moreigus ®productsMore igus ® products<strong>Chainflex</strong> ®CatalogCatalogPlease call your local distributorfor more informations about theigus ® products.Energy Chain Systems ®Polymer BearingsTel. +49-2203-96 49-0Fax +49-2203-96 49-222The complete programof Energy Chains ®Maintenance freepolymer bearingswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, Germany482


igus ® at www.igus.euMoreigus ®productsThe entire igus ® product range as well as serviceand latest news can be found on the Internet atwww.igus.euSpecial information of <strong>Chainflex</strong> ® can be found onthe Internet at www.chainflex.euEnergy Chain Systems ®<strong>Chainflex</strong> ®All products can be ordered online byclicking on Catalogs OnlineFast selection of all products and allimportant informationFree download of 3D productdrawings from the InternetMore than 20 CAD formatsand almost all productdrawings available:effective design aidPolymer Plain BearingsMore than 70.000 products, allfeatures and dataYour questionsanswered by ouronline Energy Chain ®expertsTel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanyiglidur ® plain bearings. 31 materials, allfeatures and applicationsEverything about self-adjusting andmaintenance-free igubal ® plain bearingsDryLin ® W, T, N and R. The entire programof linear plain bearingsPolysorb ® :Plastic disc springsHuge product selectionwith DXF databaseMore than 20 CAD formats and almosall product drawings available: effectivedesign aidwww.igus.euinfo@igus.de483


Control CablesData Cables<strong>Chainflex</strong> ®QuickSelectionPageCF130.ULCF140.ULCF5CF6CF77.UL.DCF78.ULCF170.DCF180CF2CF9CF10CF9.ULCF10.ULCF98CF99CF240CF211CF112CF113CF1152 56 60 64 68 70 72 74 76 80 84 88 92 96 98 102 104 106 108 110ULand/orCSA approvalPVC-free/halogen-freeCutting and WeldingSystemsTimber ProcessingMachinesLow-TemperatureApplicationsCranes/HarborEquipmentSystems/Materials-Handling Techno -logy/OutdoorCranes/Materials-HandlingTechnology Sto rage andRetrieval Units for High-Bay/ Warehouses/Indoor areasPackagingHandlingAutomationMachine Tools/ProcessingMachines484DESINAconforming


CF12CFBUSBus CablesCF11.LCCF11.LC.DCF14CAT5CF211<strong>Chainflex</strong> ® according to IndustriesMeasuring system<strong>cables</strong>/KoaxCF113.DCF111.DCF11.DCFKoax1Fibre optic <strong>cables</strong> (FOC)112 122 126 128 130 132 136 142 146 152 158 160 162 164CFLKCFLG.2HCFLG.LBCFLG.G<strong>Chainflex</strong> ®QuickSelectionPagePVC485


Servo CablesPower CablesHoses<strong>Chainflex</strong> ®QuickSelectionPageCF210.ULCF21.ULCF270.UL.DCF27.DCF30CF31CF34.UL.DCF35.ULCF37.DCF38CF300.UL.DCFPECF310.ULCF330.DCF340CFBRAIDCFCRANECFAIRCFClean AIR168 170 174 178 184 186 188 190 192 194 196 198 200 202 204 208 210 212 214DESINAconformingULand/orCSA approvalPVC-free/halogen-freeCutting and WeldingSystemsTimber ProcessingMachinesLow-TemperatureApplicationsCranes/HarborEquipmentSystems/Materials-Handling Techno -logy/OutdoorCranes/Materials-HandlingTechnology Sto rage andRetrieval Units for High-Bay/ Warehouses/Indoor areasPackagingHandlingAutomationMachine Tools/ProcessingMachines


<strong>Chainflex</strong> ® according to IndustriesTwistable CablesCFROBOT9CFROBOT8CFROBOT6/7CFROBOT5CFROBOT220 222 228 226 230<strong>Chainflex</strong> ®QuickSelectionPagePVC487


Faxigus ® <strong>Chainflex</strong> ®Customer-specific <strong>cables</strong> for Energy Chain Systems ®HarnessingDate: Phone: +49-2203-96 49-0Fax: +49-2203-96 49-222Sender:Recipient:igus ® GmbHTechnical MarketingSpicher Str. 1aPhone:51147 KölnFax:GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.de488Special applications in the sector of flexible energy supplysystems depend on special <strong>cables</strong> that function for a longtime. As a manufacturer of Energy Chains ® and the corres -ponding <strong>cables</strong>, we will plan your specific requirementcase on a customized basis – already starting from acable length of 500 meters. Planning and calculationsecurity will save you time and money.The is why our offers get to the point quickly. Please help usby filling out this questionnaire as completely as possible.With several brief items of information from the selection list,we will be glad to make you an offer. But we will also bepleased to help in person or by telephone with the clarificationof technical details.Technical informationMechanical properties ofthe requested cableApplication case (short description):______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________Energy Chain ® seriesBending radiusVelocityAccelerationTravel distance______________________________R ______________________________V ______________________________a ______________________________S ______________________________Travel frequencyNumber of double strokes/day to be expected ______________________________Number of manufacturingdays to be expected ______________________________orEnvironmentTemperature(highest/lowest)Chemical influences(oils, etc.)__________________________________________________________________________________________Outdoor/Indoor use O ■ I ■or______________________________Electrical propertiesof the requested cableVoltage class< 30 V ■300/300 V ■300/500 V ■450/750 V ■600/1000 V ■or operating voltage ______________________________Cable typeData cable■Twisted-pair■Fibre-optic■Bus specification ■Control cable ■Power cable■Servo cable■or other ■ ___________________________CoresQuantity / Cross section ■ShieldingTotal shieldPair shielding■■___________________________Sheath materialPVC■PVC oil-resistant ■PUR■TPE■Pair shielding ■Hybrid cable ■or other ■ ___________________________Additional optionsFlame-retardant ■Halogen-free ■or other ■ ___________________________ApprobationCE■CSA■DESINA■UL■or other ■ ___________________________Other itemsMax. Ø external___________________________Numeral printing/colour code N ■ C ■Estimated requirement/year ___________________________


Energy Chain Systems ®System PlanningFaxDate: Phone: +49-2203-96 49-0Fax: +49-2203-96 49-222Sender:Recipient:igus ® GmbHTechnical MarketingSpicher Str. 1aPhone:51147 KölnFax:Germanyigus ® SystemPlanningInstallation spacePlease send us information on your application data to the extent possible. Within 24 hours, you will then receivea complete analysis together with a filling proposal and offer. Please call us if you have any questions.Installation typeTravel s:mm Fixed point:Overall width:(Please check off)Travel centre point yesMax. overall width allowed?or mm from centre pointmmGuide exists?R requested:mmMax. overall height HF:mmnoyes. If yes, which guide:Dimensions: B RimmDimensions: H RimmInstallation location/floor, wall, console:mmSupporting width (standard = 2 m)mmDynamicsVelocity: (m/s) Acceleration: (m/s 2 )Distances/day: Days/year: Ø Distance:EnvironmentTemperature (°C): Moisture (%): Dust-dirt-chips:Special details?:Filling of the Energy Chains ®Quantity Manufacturer/Art. no. Cross sections Ø Weight kg/m Permissible bending radiusAdditional individual components requested:Energy Chains ® / Energy tube<strong>Chainflex</strong> ® special <strong>cables</strong>Guiding troughsStrain reliefHarnessingAssemblyOtherigus ® system guarantee requested?Energy Chains ®Energy tubeTo be opened on both sidesTo be opened in outer radiusTo be opened in inner radiusSpecial requests:www.igus.euinfo@igus.de489


FaxEnergy Chain Systems ®HarnessingHarnessingDate: Phone: +49-2203-96 49-0Fax: +49-2203-96 49-222Sender:Recipient:igus ® GmbHTechnical MarketingSpicher Str. 1aPhone:51147 KölnFax:GermanyPlanning of ready-made Energy Chain Systems ®Chain type:______________________________Length:______________________________Tel. +49-2203-96 49-0Fax +49-2203-96 49-222Filling:Interior separation/separatorsSketch of the arrangement of the <strong>cables</strong>www.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyExcess length 1 Plug end 1 Screw connection 1 Excess length 2 Screw connection 2 Plug end 2490


Fax order Fax inquiry <strong>Chainflex</strong> ®FaxDate: Phone: +49-2203-96 49-0Fax +49-2203-96 49-222Sender:Recipient:igus ® GmbHTechnical MarketingSpicher Str. 1aPhone:51147 KölnFax:GermanyHarnessingOrder No.Page_________________of________________pagesWe are placing our order based on the general terms and conditions of igus ® GmbH. Excessive and short deliveries of ± 10 %for <strong>cables</strong> conform with contractual agreements. Deliveries can be made in part-lengths. Some <strong>Chainflex</strong> ® <strong>cables</strong> have lengthinformation printed on them in metres. igus ® expressly points out that these specifications are not calibrated. Statutory VAT mustbe added to the prices.Item number igus ® order numbers Quantity Price per unitigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222Delivery deadline:Signature/stampwww.igus.euinfo@igus.de491


ContentTable of contents according to part numberTel. +49-2203-96 49-0<strong>Chainflex</strong> ®Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.deigus ® Part No. Page igus ® Part No. Page igus ® Part No. PageControl cable<strong>Chainflex</strong> ® CF2CF2.01.04 76CF2.01.08 76CF2.01.12 76CF2.01.18 76CF2.01.24 76CF2.01.36 76CF2.01.48 76CF2.02.04 76CF2.02.08 76CF2.02.18 76CF2.02.24 76CF2.02.48 76CF2.05.05 76CF2.05.07 76CF2.05.09 76CF2.05.12 76CF2.05.18 76CF2.05.24 76CF2.07.03 76CF2.07.04 76CF2.07.07 76CF2.07.12 76CF2.07.24 76CF2.10.03 76CF2.10.05 76CF2.10.07 76CF2.10.12 76CF2.10.24 76CF2.15.03 76CF2.15.07 76CF2.15.12 76Control cable<strong>Chainflex</strong> ® CF5CF5.02.36 60CF5.03.15 60CF5.03.18 60CF5.03.25 60CF5.05.02 60CF5.05.03 60CF5.05.05 60CF5.05.07 60CF5.05.12 60CF5.05.18 60CF5.05.25 60CF5.05.30 60CF5.07.03 60CF5.07.04 60CF5.07.05 60CF5.07.07 60CF5.07.12 60CF5.07.18 60CF5.07.25 60CF5.07.36 60CF5.07.42 60CF5.10.03 60CF5.10.04 60CF5.10.05 60CF5.10.07 60CF5.10.12 60CF5.10.18 60CF5.10.25 60CF5.15.03 60CF5.15.04 60CF5.15.05 60CF5.15.07 60CF5.15.12 60CF5.15.18 60CF5.15.25 60CF5.15.36 60CF5.25.04 60CF5.25.05 60CF5.25.07 60CF5.25.12 60CF5.25.18 60CF5.25.25 60Control cable<strong>Chainflex</strong> ® CF6CF6.02.04 64CF6.02.24 64CF6.03.05 64CF6.05.02 64CF6.05.05 64CF6.05.07 64CF6.05.09 64CF6.05.12 64CF6.05.18 64CF6.05.24 64CF6.07.03 64CF6.07.04 64CF6.07.05 64CF6.07.07 64CF6.07.12 64CF6.07.18 64CF6.07.24 64CF6.10.03 64CF6.10.04 64CF6.10.05 64CF6.10.07 64CF6.10.12 64CF6.10.18 64CF6.10.24 64CF6.15.03 64CF6.15.04 64CF6.15.05 64CF6.15.07 64CF6.15.12 64CF6.15.18 64CF6.15.25 64CF6.15.36 64CF6.25.04 64Control cable<strong>Chainflex</strong> ® CF9CF9.03.16.07.03.INI 80CF9.02.02 80CF9.02.03.INI 80CF9.02.06 80CF9.02.07 80CF9.02.08 80CF9.02.12 80CF9.02.18 80CF9.03.04.INI 80CF9.03.05.INI 80CF9.03.06 80CF9.03.08 80CF9.05.02 80CF9.05.03 80CF9.05.04 80CF9.05.05 80CF9.05.07 80CF9.05.12 80CF9.05.18 80CF9.05.25 80CF9.05.36 80CF9.07.05 80CF9.07.07 80CF9.07.12 80CF9.07.20 80CF9.07.25 80CF9.10.03 80CF9.10.04 80CF9.10.05 80CF9.10.12 80CF9.10.18 80CF9.10.25 80CF9.15.02 80CF9.15.04 80CF9.15.05 80CF9.15.07 80CF9.15.12 80CF9.15.18 80CF9.15.25 80CF9.15.36 80CF9.25.04 80CF9.25.05 80CF9.25.07 80CF9.25.12 80CF9.25.16 80CF9.25.18 80CF9.25.25 80CF9.40.04 80CF9.60.04 80CF9.60.05 80CF9.100.04 80CF9.160.04 80CF9.350.04 80Control cable<strong>Chainflex</strong> ® CF9.ULCF9.UL.02.02 88CF9.UL.02.03.INI 88CF9.UL.02.04 88CF9.UL.02.06 88CF9.UL.02.07 88CF9.UL.02.08 88CF9.UL.02.12 88CF9.UL.03.04.INI 88CF9.UL.03.05.INI 88CF9.UL.03.06 88CF9.UL.03.08 88CF9.UL.05.02 88CF9.UL.05.03 88CF9.UL.05.04 88CF9.UL.05.05 88CF9.UL.05.07 88CF9.UL.05.12 88CF9.UL.05.18 88CF9.UL.05.25 88CF9.UL.05.36 88CF9.UL.07.05 88CF9.UL.07.07 88CF9.UL.07.12 88CF9.UL.07.20 88CF9.UL.07.25 88CF9.UL.10.03 88CF9.UL.10.04 88CF9.UL.10.05 88CF9.UL.10.12 88CF9.UL.10.18 88492


Table of contents according to part numberContentigus ® Part No. Page igus ® Part No. Page igus ® Part No. PageCF9.UL.10.25 88CF9.UL.15.04 88CF9.UL.15.05 88CF9.UL.15.07 88CF9.UL.15.12 88CF9.UL.15.18 88CF9.UL.15.25 88CF9.UL.25.04 88CF9.UL.25.05 88CF9.UL.25.07 88CF9.UL.25.12 88CF9.UL.25.16 88CF9.UL.25.18 88CF9.UL.25.25 88CF9.UL.40.04 88CF9.UL.60.04 88Control cable<strong>Chainflex</strong> ® CF10CF10.01.12 84CF10.01.18 84CF10.02.04 84CF10.02.08 84CF10.02.12 84CF10.02.24 84CF10.03.05.INI 84CF10.05.04 84CF10.05.05 84CF10.05.07 84CF10.05.12 84CF10.05.18 84CF10.05.25 84CF10.07.04 84CF10.07.05 84CF10.07.07 84CF10.07.12 84CF10.07.20 84CF10.07.24 84CF10.10.02 84CF10.10.03 84CF10.10.04 84CF10.10.05 84CF10.10.07 84CF10.10.12 84CF10.10.18 84CF10.10.24 84CF10.15.04 84CF10.15.05 84CF10.15.07 84CF10.15.12 84CF10.15.18 84CF10.25.04 84CF10.25.07 84CF10.25.12 84CF10.40.04 84CF10.40.05 84Control cable<strong>Chainflex</strong> ® CF10.ULCF10.UL.02.04 92CF10.UL.02.08 92CF10.UL.02.12 92CF10.UL.02.24 92CF10.UL.05.04 92CF10.UL.05.05 92CF10.UL.05.12 92CF10.UL.05.18 92CF10.UL.05.25 92CF10.UL.07.03 92CF10.UL.07.04 92CF10.UL.07.05 92CF10.UL.07.07 92CF10.UL.07.12 92CF10.UL.07.20 92CF10.UL.07.24 92CF10.UL.10.02 92CF10.UL.10.03 92CF10.UL.10.04 92CF10.UL.10.05 92CF10.UL.10.07 92CF10.UL.10.12 92CF10.UL.10.18 92CF10.UL.10.24 92CF10.UL.15.04 92CF10.UL.15.05 92CF10.UL.15.07 92CF10.UL.15.12 92CF10.UL.15.18 92CF10.UL.25.04 92CF10.UL.25.07 92CF10.UL.25.12 92CF10.UL.40.04 92Data cable<strong>Chainflex</strong> ® CF11CF11.01.04.02 110CF11.01.18.02 110CF11.02.02.02 110CF11.02.03.02 110CF11.02.04.02 110CF11.02.05.02 110CF11.02.06.02 110CF11.02.09.02 110CF11.02.10.02 110CF11.02.14.02 110CF11.03.08.02 110CF11.05.04.02 110CF11.05.06.02 110CF11.05.08.02 110CF11.07.03.02 110CF11.10.04.02 110CF11.15.06.02 110CF11.25.03.02 110Measuring system <strong>cables</strong><strong>Chainflex</strong> ® CF11.DCF11.001.D 146CF11.002.D 146CF11.003.D 146CF11.004.D 146CF11.005.D 146CF11.006.D 146CF11.007.D 146CF11.008.D 146CF11.009.D 146CF11.010.D 146CF11.011.D 146CF11.012.D 146CF11.013.D 146CF11.014.D 146CF11.015.D 146CF11.016.D 146CF11.017.D 146CF11.018.D 146CF11.019.D 146CF11.021.D 146CF11.022.D 146CF11.025.D 146CF11.027.D 146CF11.032.D 146CF11.033.D 146CF11.034.D 146Bus cable<strong>Chainflex</strong> ® CF11.LCCF11.02.03.02.IB-S 126CF11.02.03.02.10.03.IB-S 126CF11.05.01.02.LC 126CF11.05.02.02.LC 126CF11.02.02.02.PBA.LC 126Bus cable<strong>Chainflex</strong> ® CF11.LC.DCF11.02.01.02.PBA.LC.D 128CF11.02.02.15.04.PBA.LC.D 128CF11.02.02.07.03.PBA.LC.D 128CF11.02.02.02.LC.D 128CF11.05.01.02.LC.D 128Data cable<strong>Chainflex</strong> ® CF12CF12.02.02.02 112CF12.02.03.02 112CF12.02.04.02 112CF12.02.05.02 112CF12.05.03.02 112CF12.05.04.02 112CF12.05.05.02 112CF12.05.06.02 112CF12.05.08.02 112CF12.05.10.02 112CF12.05.14.02 112CF12.10.06.02 112Bus cable<strong>Chainflex</strong> ® CF14CF14.02.02.02.CAT5 130CF14.02.04.02.CAT5 130CF14.02.05.02.CAT5 130Servo cable<strong>Chainflex</strong> ® CF21.ULCF21.07.05.02.01.UL 170CF21.15.10.02.01.UL 170CF21.15.15.02.01.UL 170CF21.25.10.02.01.UL 170CF21.25.15.02.01.UL 170CF21.40.10.02.01.UL 170CF21.40.15.02.01.UL 170CF21.60.10.02.01.UL 170CF21.60.15.02.01.UL 170CF21.100.10.02.01.UL 170CF21.100.15.02.01.UL 170CF21.160.15.02.01.UL 170CF21.250.15.02.01.UL 170CF21.350.15.02.01.UL 170CF21.07.03.02.02.UL 170CF21.10.07.02.02.UL 170CF21.15.07.02.02.UL 170CF21.25.15.02.02.UL 170CF21.40.15.02.02.UL 170CF21.60.15.02.02.UL 170CF21.100.15.02.02.UL 170CF21.160.15.02.02.UL 170CF21.250.15.02.02.UL 170CF21.350.15.02.02.UL 170Tel. +49-2203-96 49-0<strong>Chainflex</strong> ®Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.de493


ContentTable of contents according to part numberigus ® Part No. Page igus ® Part No. Page igus ® Part No. PageTel. +49-2203-96 49-0<strong>Chainflex</strong> ®Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.deServo cable<strong>Chainflex</strong> ® CF27.DCF27.07.05.02.01.D 178CF27.15.10.02.01.D 178CF27.15.15.02.01.D 178CF27.25.10.02.01.D 178CF27.25.15.02.01.D 178CF27.40.10.02.01.D 178CF27.40.15.02.01.D 178CF27.60.10.02.01.D 178CF27.60.15.02.01.D 178CF27.100.10.02.01.D 178CF27.100.15.02.01.D 178CF27.160.10.02.01.D 178CF27.160.15.02.01.D 178CF27.250.15.02.01.D 178CF27.350.15.02.01.D 178CF27.07.03.02.02.D 178CF27.10.07.02.02.D 178CF27.15.07.02.02.D 178CF27.25.15.02.02.D 178CF27.40.15.02.02.D 178CF27.60.15.02.02.D 178CF27.100.15.02.02.D 178CF27.160.15.02.02.D 178CF27.250.15.02.02.D 178CF27.350.15.02.02.D 178CF27.15.05.04.D 178CF27.25.05.04.D 178CF27.40.05.04.D 178CF27.60.05.04.D 178CF27.07.04.D 178CF27.10.04.D 178CF27.15.04.D 178CF27.25.04.D 178CF27.500.04.D 178Power cable<strong>Chainflex</strong> ® CF30CF30.15.04 184CF30.25.04 184CF30.25.05 184CF30.40.04 184CF30.40.05 184CF30.60.04 184CF30.60.05 184CF30.100.04 184CF30.100.05 184CF30.160.04 184CF30.160.05 184CF30.250.04 184CF30.350.04 184CF30.500.04 184Power cable<strong>Chainflex</strong> ® CF31CF31.15.04 186CF31.25.04 186CF31.25.05 186CF31.40.04 186CF31.40.05 186CF31.60.04 186CF31.60.05 186CF31.100.04 186CF31.100.05 186CF31.160.04 186CF31.250.04 186CF31.350.04 186CF31.500.04 186CF31.700.04 186Power cable<strong>Chainflex</strong> ® CF34.UL.DCF34.UL.15.04.D 188CF34.UL.25.04.D 188CF34.UL.40.04.D 188CF34.UL.60.04.D 188CF34.UL.60.05.D 188CF34.UL.100.04.D 188CF34.UL.100.05.D 188CF34.UL.160.04.D 188CF34.UL.160.05.D 188CF34.UL.250.04.D 188CF34.UL.60.04.O.PE.D 188CF34.UL.100.04.O.PE.D 188CF34.UL.160.04.O.PE.D 188CF34.UL.500.03.O.PE.D 188Power cable<strong>Chainflex</strong> ® CF35.ULCF35.UL.05.04 190CF35.UL.07.04 190CF35.UL.15.04 190CF35.UL.25.04 190CF35.UL.40.04 190CF35.UL.60.04 190CF35.UL.100.04 190CF35.UL.160.04 190CF35.UL.250.04 190CF35.UL.60.03.O.PE 190CF35.UL.100.03.O.PE 190CF35.UL.160.03.O.PE 190CF35.UL.250.03.O.PE 190CF35.UL.350.03.O.PE 190CF35.UL.500.03.O.PE 190Power cable<strong>Chainflex</strong> ® CF37.DCF37.15.04.D 192CF37.25.04.D 192CF37.40.04.D 192CF37.60.04.D 192CF37.60.05.D 192CF37.100.04.D 192CF37.100.05.D 192CF37.160.04.D 192CF37.160.05.D 192CF37.250.04.D 192CF37.60.04.O.PE.D 192CF37.100.04.O.PE.D 192CF37.160.04.O.PE.D 192CF37.500.03.O.PE.D 192Power cable<strong>Chainflex</strong> ® CF38CF38.05.04 194CF38.07.04 194CF38.15.04 194CF38.25.04 194CF38.40.04 194CF38.60.04 194CF38.100.04 194CF38.160.04 194CF38.250.04 194CF38.60.03.O.PE 194CF38.100.03.O.PE 194CF38.160.03.O.PE 194CF38.250.03.O.PE 194CF38.350.03.O.PE 194CF38.500.03.O.PE 194Control cable<strong>Chainflex</strong> ® CF77.UL.DCF77.UL.02.04.D 68CF77.UL.05.04.D 68CF77.UL.05.05.D 68CF77.UL.05.12.D 68CF77.UL.05.18.D 68CF77.UL.05.25.D 68CF77.UL.05.30.D 68CF77.UL.07.03.D 68CF77.UL.07.04.D 68CF77.UL.07.05.D 68CF77.UL.07.07.D 68CF77.UL.07.12.D 68CF77.UL.07.18.D 68CF77.UL.07.20.D 68CF77.UL.07.36.D 68CF77.UL.10.02.D 68CF77.UL.10.03.D 68CF77.UL.10.04.D 68CF77.UL.10.05.D 68CF77.UL.10.07.D 68CF77.UL.10.12.D 68CF77.UL.10.18.D 68CF77.UL.10.25.D 68CF77.UL.15.03.D 68CF77.UL.15.04.D 68CF77.UL.15.05.D 68CF77.UL.15.07.D 68CF77.UL.15.12.D 68CF77.UL.15.18.D 68CF77.UL.15.25.D 68CF77.UL.25.04.D 68CF77.UL.25.05.D 68CF77.UL.25.07.D 68CF77.UL.40.04.D 68Control cable<strong>Chainflex</strong> ® CF78.ULCF78.UL.05.04 70CF78.UL.05.05 70CF78.UL.05.07 70CF78.UL.05.09 70CF78.UL.05.12 70CF78.UL.05.18 70CF78.UL.05.24 70CF78.UL.07.03 70CF78.UL.07.04 70CF78.UL.07.05 70CF78.UL.07.07 70CF78.UL.07.12 70CF78.UL.07.18 70CF78.UL.10.03 70CF78.UL.10.04 70CF78.UL.10.05 70CF78.UL.10.07 70CF78.UL.10.12 70CF78.UL.10.18 70CF78.UL.10.25 70CF78.UL.15.03 70CF78.UL.15.04 70CF78.UL.15.05 70CF78.UL.15.07 70CF78.UL.15.12 70CF78.UL.25.04 70CF78.UL.25.05 70CF78.UL.25.07 70CF78.UL.40.04 70494


Table of contents according to part numberContentigus ® Part No. Page igus ® Part No. Page igus ® Part No. PageControl cable<strong>Chainflex</strong> ® CF98CF98.01.02 96CF98.01.03 96CF98.01.04 96CF98.01.07 96CF98.01.08 96CF98.02.03.INI 96CF98.02.04 96CF98.02.07 96CF98.02.08 96CF98.03.03 96CF98.03.04.INI 96CF98.03.07 96CF98.03.08 96CF98.05.04 96Control cable<strong>Chainflex</strong> ® CF99CF99.01.02 98CF99.01.03 98CF99.01.04 98CF99.01.07 98CF99.01.08 98CF99.02.03 98CF99.02.04 98CF99.02.07 98CF99.02.08 98CF99.03.03 98CF99.03.04 98CF99.03.08 98Data cable<strong>Chainflex</strong> ® CF111CF111 – Wurde ersetzt durch CF113Measuring system <strong>cables</strong><strong>Chainflex</strong> ® CF111.DCF111.001.D 142CF111.004.D 142CF111.006.D 142CF111.011.D 142CF111.015.D 142CF111.021.D 142CF111.022.D 142CF111.027.D 142CF111.035.D 142Data cable<strong>Chainflex</strong> ® CF112CF112.02.02.02 106CF112.02.03.02 106CF112.02.04.02 106CF112.02.05.02 106CF112.02.06.02 106CF112.05.02.02 106CF112.05.03.02 106CF112.05.04.02 106CF112.05.05.02 106CF112.05.06.02 106Data cable<strong>Chainflex</strong> ® CF113CF113.02.02.02 108CF113.02.03.02 108CF113.02.04.02 108CF113.02.05.02 108CF113.02.06.02 108CF113.05.02.02 108CF113.05.03.02 108CF113.05.04.02 108CF113.05.05.02 108CF113.05.06.02 108Measuring system <strong>cables</strong><strong>Chainflex</strong> ® CF113.DCF113.001.D 136CF113.002.D 136CF113.003.D 136CF113.004.D 136CF113.005.D 136CF113.006.D 136CF113.007.D 136CF113.008.D 136CF113.009.D 136CF113.010.D 136CF113.011.D 136CF113.012.D 136CF113.013.D 136CF113.014.D 136CF113.015.D 136CF113.016.D 136CF113.017.D 136CF113.018.D 136CF113.019.D 136CF113.021.D 136CF113.022.D 136CF113.025.D 136CF113.027.D 136CF113.028.D 136CF113.032.D 136CF113.033.D 136CF113.034.D 136Control cable<strong>Chainflex</strong> ® CF130.ULCF130.02.03.UL 52CF130.02.04.UL 52CF130.02.06.UL 52CF130.02.07.UL 52CF130.02.12.UL 52CF130.02.20.UL 52CF130.02.25.UL 52CF130.02.30.UL 52CF130.03.02.UL 52CF130.03.05.UL 52CF130.05.02.UL 52CF130.05.03.UL 52CF130.05.04.UL 52CF130.05.05.UL 52CF130.05.07.UL 52CF130.05.12.UL 52CF130.05.18.UL 52CF130.05.25.UL 52CF130.07.02.UL 52CF130.07.03.UL 52CF130.07.04.UL 52CF130.07.05.UL 52CF130.07.07.UL 52CF130.07.12.UL 52CF130.07.18.UL 52CF130.07.25.UL 52CF130.10.02.UL 52CF130.10.03.UL 52CF130.10.04.UL 52CF130.10.05.UL 52CF130.10.07.UL 52CF130.10.12.UL 52CF130.10.18.UL 52CF130.10.25.UL 52CF130.15.02.UL 52CF130.15.03.UL 52CF130.15.04.UL 52CF130.15.05.UL 52CF130.15.07.UL 52CF130.15.12.UL 52CF130.15.18.UL 52CF130.15.25.UL 52CF130.25.03.UL 52CF130.25.04.UL 52CF130.25.07.UL 52CF130.25.12.UL 52CF130.40.03.UL 52CF130.60.04.UL 52CF130.60.05.UL 52Control cable<strong>Chainflex</strong> ® CF140.ULCF140.02.12.UL 56CF140.03.05.UL 56CF140.05.03.UL 56CF140.05.05.UL 56CF140.05.18.UL 56CF140.05.36.UL 56CF140.07.03.UL 56CF140.07.04.UL 56CF140.07.05.UL 56CF140.07.07.UL 56CF140.07.12.UL 56CF140.07.18.UL 56CF140.07.25.UL 56CF140.10.02.UL 56CF140.10.03.UL 56CF140.10.04.UL 56CF140.10.05.UL 56CF140.10.07.UL 56CF140.10.12.UL 56CF140.10.18.UL 56CF140.10.25.UL 56CF140.15.03.UL 56CF140.15.04.UL 56CF140.15.05.UL 56CF140.15.07.UL 56CF140.15.12.UL 56CF140.15.18.UL 56CF140.15.25.UL 56CF140.25.03.UL 56CF140.25.04.UL 56Control cable<strong>Chainflex</strong> ® CF170.DCF170.05.12.D 72CF170.05.18.D 72CF170.05.30.D 72CF170.07.03.D 72CF170.07.05.D 72CF170.07.07.D 72CF170.07.12.D 72CF170.07.18.D 72CF170.07.20.D 72CF170.10.03.D 72CF170.10.04.D 72CF170.10.05.D 72CF170.10.07.D 72CF170.10.12.D 72CF170.10.18.D 72CF170.10.25.D 72CF170.15.03.D 72CF170.15.04.D 72CF170.15.05.D 72CF170.15.07.D 72CF170.15.12.D 72Tel. +49-2203-96 49-0<strong>Chainflex</strong> ®Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.de495


ContentTable of contents according to part numberTel. +49-2203-96 49-0<strong>Chainflex</strong> ®Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.deigus ® Part No. Page igus ® Part No. Page igus ® Part No. PageCF170.15.18.D 72CF170.15.25.D 72CF170.25.04.D 72CF170.25.05.D 72CF170.25.07.D 72CF170.40.04.D 72CF170.60.04.D 72CF170.100.04.D 72Control cable<strong>Chainflex</strong> ® CF180CF180.05.18 74CF180.07.03 74CF180.07.05 74CF180.07.12 74CF180.07.18 74CF180.10.05 74CF180.10.18 74CF180.15.03 74CF180.15.04 74CF180.15.07 74CF180.25.04 74CF180.25.05 74CF180.25.07 74Servo cable<strong>Chainflex</strong> ® CF210.ULCF210.UL.15.15.02.01 168CF210.UL.25.15.02.01 168CF210.UL.40.15.02.01 168CF210.UL.60.15.02.01 168CF210.UL.15.07.02.02 168CF210.UL.25.15.02.02 168CF210.UL.40.15.02.02 168CF210.UL.60.15.02.02 168Data cable<strong>Chainflex</strong> ® CF211CF211.02.01.02 104CF211.02.02.02 104CF211.02.03.02 104CF211.02.04.02 104CF211.02.05.02 104CF211.02.06.02 104CF211.02.08.02 104CF211.02.10.02 104CF211.02.14.02 104CF211.03.03.02 104CF211.03.08.02 104CF211.03.10.02 104CF211.05.01.02 104CF211.05.02.02 104CF211.05.03.02 104CF211.05.04.02 104CF211.05.05.02 104CF211.05.06.02 104CF211.05.08.02 104CF211.05.10.02 104CF211.05.14.02 104Measuring system <strong>cables</strong><strong>Chainflex</strong> ® CF211CF211.001 132CF211.002 132CF211.006 132CF211.009 132CF211.010 132CF211.011 132CF211.014 132CF211.016 132CF211.017 132CF211.018 132CF211.019 132CF211.027 132Data cable<strong>Chainflex</strong> ® CF240CF240.01.03 102CF240.01.04 102CF240.01.05 102CF240.01.07 102CF240.01.14 102CF240.01.18 102CF240.01.24 102CF240.02.03 102CF240.02.04 102CF240.02.05 102CF240.02.07 102CF240.02.08 102CF240.02.14 102CF240.02.18 102CF240.02.24 102CF240.03.03 102CF240.03.04 102CF240.03.05 102CF240.03.07 102CF240.03.10 102CF240.03.14 102CF240.03.18 102CF240.03.24 102Servo cable<strong>Chainflex</strong> ® CF260CF260 – Wurde ersetzt durchCF210.UL (PVC) und CF270.UL.D (PUR)Servo cable<strong>Chainflex</strong> ® CF270.UL.DCF270.UL.15.15.02.01.D 174CF270.UL.25.15.02.01.D 174CF270.UL.40.15.02.01.D 174CF270.UL.60.15.02.01.D 174CF270.UL.100.15.02.01.D 174CF270.UL.160.15.02.01.D 174CF270.UL.10.07.02.02.D 174CF270.UL.15.07.02.02.D 174CF270.UL.25.15.02.02.D 174CF270.UL.40.15.02.02.D 174CF270.UL.60.15.02.02.D 174CF270.UL.100.15.02.02.D 174CF270.UL.160.15.02.02.D 174CF270.UL.250.15.02.02.D 174CF270.UL.350.15.02.02.D 174CF270.UL.15.10.03.01.D 174CF270.UL.25.10.03.01.D 174CF270.UL.60.05.04.D 174CF270.UL.15.04.D 174CF270.UL.25.04.D 174CF270.UL.40.04.D 174CF270.UL.60.04.D 174CF270.UL.100.04.D 174CF270.UL.160.04.D 174CF270.UL.250.04.D 174CF270.UL.350.04.D 174Power cable<strong>Chainflex</strong> ® CF300.UL.DCF300.UL.60.01.D 196CF300.UL.100.01.D 196CF300.UL.160.01.D 196CF300.UL.250.01.D 196CF300.UL.350.01.D 196CF300.UL.500.01.D 196CF300.UL.700.01.D 196CF300.UL.950.01.D 196CF300.UL.1200.01.D 196CF300.UL.1500.01.D 196CF300.UL.1850.01.D 196Power cable<strong>Chainflex</strong> ® CF310.ULCF310.UL.40.01 200CF310.UL.60.01 200CF310.UL.100.01 200CF310.UL.160.01 200CF310.UL.250.01 200CF310.UL.350.01 200CF310.UL.500.01 200CF310.UL.700.01 200CF310.UL.950.01 200CF310.UL.1200.01 200CF310.UL.1500.01 200CF310.UL.1850.01 200Power cable<strong>Chainflex</strong> ® CF 330.DCF330.60.01.D 202CF330.100.01.D 202CF330.160.01.D 202CF330.250.01.D 202CF330.350.01.D 202CF330.500.01.D 202CF330.700.01.D 202CF330.950.01.D 202CF330.1200.01.D 202CF330.1500.01.D 202CF330.1850.01.D 202Power cable<strong>Chainflex</strong> ® CF 340CF340.40.01 204CF340.60.01 204CF340.100.01 204CF340.160.01 204CF340.250.01 204CF340.350.01 204CF340.500.01 204CF340.700.01 204CF340.950.01 204CF340.1200.01 204CF340.1500.01 204CF340.1850.01 204Power cable<strong>Chainflex</strong> ® CF BRAIDCFBRAID.25.08 208CFBRAID.25.08.C 208Bus cable<strong>Chainflex</strong> ® CF BUSCFBUS.001 122CFBUS.002 122CFBUS.003 122CFBUS.010 122CFBUS.011 122CFBUS.020 122CFBUS.021 122CFBUS.022 122CFBUS.030 122CFBUS.031 122CFBUS.035 122CFBUS.040 122496


Table of contents according to part numberNotesigus ® Part No.PageCFBUS.041 122CFBUS.042 122CFBUS.044 122CFBUS.045 122CFBUS.050 122CFBUS.055 122CFBUS.060 122CFBUS.065 122CFBUS.066 122CFBUS.070 122Bus cable<strong>Chainflex</strong> ® CF BUS.PURCFBUS.PUR.001 120CFBUS.PUR.021 120CFBUS.PUR.022 120CFBUS.PUR.045 120Bus cable<strong>Chainflex</strong> ® CF BUS.PVCCFBUS.PVC.001 118CFBUS.PVC.021 118CFBUS.PVC.022 118CFBUS.PVC.045 118Power cable<strong>Chainflex</strong> ® CF CRANECFCRANE1x25/16-6/10kV 210CFCRANE1x35/16-6/10kV 210CFCRANE1x50/16-6/10kV 210CFCRANE1x70/16-6/10kV 210CFCRANE1x95/16-6/10kV 210Power cable<strong>Chainflex</strong> ® CF FLATCFFLAT.25.01 206CFFLAT.40.01 206Koax cable<strong>Chainflex</strong> ® CF Koax1CFKoax1.01 152CFKoax1.05 152Twistable cable<strong>Chainflex</strong> ® CFROBOTCFROBOT.035 230CFROBOT.036 230CFROBOT.037 230CFROBOT.038 230CFROBOT.039 230Twistable cable<strong>Chainflex</strong> ® CFROBOT4CFROBOT4.001 224CFROBOT4.002 224CFROBOT4.009 224CFROBOT4.015 224CFROBOT4.028 224Twistable cable<strong>Chainflex</strong> ® CFROBOT5CF Robot5.500 226CF Robot5.501 226Twistable cable<strong>Chainflex</strong> ® CFROBOT6CFROBOT6.100.03 228CFROBOT6.160.03 228CFROBOT6.250.03 228CFROBOT6.350.03 228Twistable cable<strong>Chainflex</strong> ® CFROBOT7CFROBOT7.15.03.C 228CFROBOT7.25.03.C 228CFROBOT7.15.04.C 228CFROBOT7.25.04.C 228CFROBOT7.15.15.02.02.C 228CFROBOT7.25.15.02.02.C 228CFROBOT7.40.02.02.04.C 228Twistable cable<strong>Chainflex</strong> ® CFROBOT8CFROBOT8.001 222CFROBOT8.022 222CFROBOT8.045 222Twistable cable<strong>Chainflex</strong> ® CFROBOT9CFROBOT9.001 220CFROBOT9.002 220CFROBOT9.003 220CFROBOT9.004 220CFROBOT9.005 220CFROBOT9.006 220CFROBOT9.007 220Fibre optic cable (FOC)<strong>Chainflex</strong> ® CFLG.2HCFLG.2HG.MF.62,5/125 160CFLG.2HG.MF.50/125 160CFLG.2HS.MF.200/230 160Fibre optic cable (FOC)<strong>Chainflex</strong> ® CFLG.LBCFLG.2LB.62,5/125 162CFLG.2LB.50/125 162Fibre optic cable (FOC)<strong>Chainflex</strong> ® CFLG. GCFLG.6G.62,5/125.TC 164CFLG.12G.62,5/125.TC 164CFLG.6G.50/125.TC 164CFLG.12G.50/125.TC 164Fibre optic cable (FOC)<strong>Chainflex</strong> ® CFLKCFLK.L1.01 158Power cable<strong>Chainflex</strong> ® CFPECFPE.15.01 198CFPE.25.01 198CFPE.40.01 198CFPE.60.01 198CFPE.100.01 198CFPE.160.01 198CFPE.250.01 198CFPE.350.01 198Tel. +49-2203-96 49-0<strong>Chainflex</strong> ®Fax +49-2203-96 49-222igus ® GmbH51147 Köln, Germanywww.igus.euinfo@igus.de497


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®498


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®499


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®502


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®503


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®504


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®505


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®506


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®507


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®508


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®509


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®510


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®511


Noteswww.igus.euinfo@igus.deigus ® GmbH51147 Köln, GermanyTel. +49-2203-96 49-0Fax +49-2203-96 49-222<strong>Chainflex</strong> ®512


Give us your opinion!Yes, we can! Catalogue improvement.Dear costumers,with every new <strong>Chainflex</strong> ® catalogue we agonize abouthow we can do the catalogue easier and better. Andwe know our catalogue so well that many details aretotally clear for us. Then a costumer asks a detailedquestion and we notice, that it is not said that clear inthe catalogue.Rainer RösselManager, Engineering and Marketing<strong>Chainflex</strong> ® , invis ® power & Ready Chain ®That's why we ask you for your oppinion. What do youlike in the catalogue? And more important: What doyou like not?Send us an e-mail tochainflex-katalog@igus.deEvery comment is welcome - whether it's concerningusability, design, delivery tables, the tests or technicaldata.Thanks in advance for your cooperation.Best RegardsRainer RösselManager, Engineering and Marketing<strong>Chainflex</strong> ® , invis ® power & ReadyChain ®


Definition of the icons used in the catalogueTemperaturerange movedTemperaturerange fixedv max. unsupported/glidingTorsiona max.TraveldistanceUV-resistantNominalvoltageTestingvoltageOilOffshore Flame-retardant Silicon-free Halogen-free Lead freeOuter jacket Outer jacket Inner jacket IntermediatejacketCore strandingCoreidentificationConductor Fibre Cables Core insulation Overall shieldCenter element Filling Element shield Element jacket MaterialDimensionsOperatingpressureVacuum UL UL/CSACSA CEI CE DESINA Clean room


.eu/...®Ordering and deliveries weekdays from 8.00 am - 8.00 pm,Saturday from 8.00 am - 12.00 pm. No minimum orderquantities, no surcharges. 80,000 E-Chain ® productsavailable ex stock. Prompt delivery."Service around-the-clock".www.igus.eu Phone: +49-2203-9649-0 Fax: -222Online shopping – 24h! www.igus.eu/24.eu/24®/9001.2008Certified according to DIN ISO 9001:2008/readychainChain – cable – guarantee!Ask for fully harnessed and preassembled Ready -Chains ® – increase your cash-flow and profitimmediately. The igus ® system guarantee alsocovers components delivered loose.www.readychain.eu.eu/...igus ® GmbH Spicher Str. 1a D-51147 CologneTel. +49-2203-9649-0 Fax +49-2203-9649-222info@igus.de www.igus.eu© 2010 igus ® GmbH®Subject to technical alterations! MAT 0070582.20 Stand 7.2010/2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!