Belt Conveyor Pull Rope Switch PAS
Belt Conveyor Pull Rope Switch PAS
Belt Conveyor Pull Rope Switch PAS
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Contact Arrangements<br />
Connection diagram<br />
Terminals<br />
1<br />
.<br />
5<br />
Installation<br />
For assembling the <strong>PAS</strong> switch on the conveyor structure please refer to the following sketch.<br />
Swing hook<br />
Tension spring<br />
<strong>Rope</strong> loop<br />
Eyebolts<br />
Distance: max. 2.5mm<br />
<strong>Pull</strong> wire<br />
Length max. 30m<br />
Reset button<br />
max.<br />
122 mm<br />
<strong>Rope</strong> clamp<br />
<strong>Rope</strong> clamp Turnbuckle<br />
To adjust the correct tension of the rope a spacer is placed<br />
between enclosure and bellow.<br />
The pull rope is correctly adjusted if the spacer can easily<br />
be removed without any varying of the distance „x“.<br />
length of the <strong>Rope</strong><br />
The max. length of the rope depending on the ambient temperature is shown in the following diagram<br />
80<br />
70<br />
Maximum Ambient Temperature<br />
60<br />
50<br />
°C]<br />
[in<br />
Ambient Temperature<br />
40<br />
30<br />
20<br />
10<br />
0<br />
-10<br />
Ambient Temperature for Mounting (;15 °C )<br />
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30<br />
-20<br />
-30<br />
Minimum Ambient Temperature<br />
Wire Length for a <strong>Pull</strong> Wire with a Diameter of 3 mm [in m]<br />
Wire length for a pull wire with a diameter of 3 mm [in m]