Reference (A)<br />

Lamp base to power coupler<br />

contact<br />

Faulty wiring<br />

Good contact between the lamp base and the power coupler is<br />

essential. The lamp is attached to the fixture by the power coupler<br />

only, check to see if the lamp is mounted on the power coupler<br />

correctly.<br />

Check all 5 connections (ground, mains input, HF-output) on the<br />

generator for correct wiring, loose contacts, poor connections, or<br />

broken wiring.<br />

All generators must always be grounded. Generators and<br />

components may be grounded to the fixture or otherwise connected<br />

to the ground. It is hazardous and possibly fatal for a human to make<br />

contact with an ungrounded fixture, generator or other electrical<br />

component while it is in operation.<br />

Coaxial cable<br />

The coaxial cable of the power coupler may not be crushed, i.e. the<br />

bending diameter is limited.<br />

The distance between the (coaxial) generator output cable and the<br />

generator input leads (mains cable) should be as big as possible, but<br />

at least 10cm (~4 inch).<br />

The wire and plug-in connectors between the power coupler and<br />

generator must not be altered in any way and must be kept away<br />

from the surface of the lamp.<br />

Power coupler cooling<br />

<strong>QL</strong> lamps are restricted to an optimum operating temperature. For<br />

example, lamp and power coupler should be firmly attached on a<br />

heat sink with 4 bolts with a prescribed diameter, length and<br />

material. Otherwise, the lamp may produce low light output or fail<br />

early.<br />

The generator and power coupler are not mounted on a shared heat<br />

sink.<br />

Generator cooling<br />

Lamp damage due to handling or<br />

shipping<br />

The bottom of the generator is mounted flat against a large metallic<br />

surface of the fixture for good heat transfer.<br />

The generator and power coupler are not mounted on a shared heat<br />

sink.<br />

Damage to the system from handling or shipping may cause a crack<br />

in the glass or broken wires.<br />