Reference (A)<br />
Lamp base to power coupler<br />
contact<br />
Faulty wiring<br />
Good contact between the lamp base and the power coupler is<br />
essential. The lamp is attached to the fixture by the power coupler<br />
only, check to see if the lamp is mounted on the power coupler<br />
correctly.<br />
Check all 5 connections (ground, mains input, HF-output) on the<br />
generator for correct wiring, loose contacts, poor connections, or<br />
broken wiring.<br />
All generators must always be grounded. Generators and<br />
components may be grounded to the fixture or otherwise connected<br />
to the ground. It is hazardous and possibly fatal for a human to make<br />
contact with an ungrounded fixture, generator or other electrical<br />
component while it is in operation.<br />
Coaxial cable<br />
The coaxial cable of the power coupler may not be crushed, i.e. the<br />
bending diameter is limited.<br />
The distance between the (coaxial) generator output cable and the<br />
generator input leads (mains cable) should be as big as possible, but<br />
at least 10cm (~4 inch).<br />
The wire and plug-in connectors between the power coupler and<br />
generator must not be altered in any way and must be kept away<br />
from the surface of the lamp.<br />
Power coupler cooling<br />
<strong>QL</strong> lamps are restricted to an optimum operating temperature. For<br />
example, lamp and power coupler should be firmly attached on a<br />
heat sink with 4 bolts with a prescribed diameter, length and<br />
material. Otherwise, the lamp may produce low light output or fail<br />
early.<br />
The generator and power coupler are not mounted on a shared heat<br />
sink.<br />
Generator cooling<br />
Lamp damage due to handling or<br />
shipping<br />
The bottom of the generator is mounted flat against a large metallic<br />
surface of the fixture for good heat transfer.<br />
The generator and power coupler are not mounted on a shared heat<br />
sink.<br />
Damage to the system from handling or shipping may cause a crack<br />
in the glass or broken wires.<br />
37