Reference (D)<br />
Improper generator wiring<br />
Generator test<br />
Power coupler test<br />
Lamp test<br />
Check the wiring diagram on the generator label.<br />
1. Install a known good power coupler and lamp<br />
2. If the lamp lights normally, you have just corrected the cause of<br />
the problem.<br />
3. If the lamp does not light, the generator is inoperative. Replace<br />
the generator.<br />
1. Install a known good generator and lamp<br />
2. If the lamp lights normally, you have just corrected the cause of<br />
the problem.<br />
3. If the lamp does not light, the power coupler is inoperative.<br />
Replace the power coupler.<br />
1. Install a known good generator and power coupler<br />
2. If the lamp lights normally, you have just corrected the cause of<br />
the problem.<br />
3. If the lamp does not light, the lamp is inoperative. Replace the<br />
lamp.<br />
Reference (E)<br />
Operating line voltage limits<br />
To receive the full benefits of rated lamp light output and to prolong<br />
generator life, it is essential that the voltage supplied to an<br />
installation be maintained within the prescribed limits.<br />
Low voltage has no damaging effect on the generator. It could,<br />
however, have an adverse effect on lamp performance and starting<br />
dependability.<br />
Subjecting a ballast to excessive voltage will cause early ballast<br />
failure.<br />
39