Reference (D)<br />

Improper generator wiring<br />

Generator test<br />

Power coupler test<br />

Lamp test<br />

Check the wiring diagram on the generator label.<br />

1. Install a known good power coupler and lamp<br />

2. If the lamp lights normally, you have just corrected the cause of<br />

the problem.<br />

3. If the lamp does not light, the generator is inoperative. Replace<br />

the generator.<br />

1. Install a known good generator and lamp<br />

2. If the lamp lights normally, you have just corrected the cause of<br />

the problem.<br />

3. If the lamp does not light, the power coupler is inoperative.<br />

Replace the power coupler.<br />

1. Install a known good generator and power coupler<br />

2. If the lamp lights normally, you have just corrected the cause of<br />

the problem.<br />

3. If the lamp does not light, the lamp is inoperative. Replace the<br />

lamp.<br />

Reference (E)<br />

Operating line voltage limits<br />

To receive the full benefits of rated lamp light output and to prolong<br />

generator life, it is essential that the voltage supplied to an<br />

installation be maintained within the prescribed limits.<br />

Low voltage has no damaging effect on the generator. It could,<br />

however, have an adverse effect on lamp performance and starting<br />

dependability.<br />

Subjecting a ballast to excessive voltage will cause early ballast<br />

failure.<br />

39