Prospector Series Poppet <strong>Valve</strong>s<br />

Solenoid Pilot Operated Inline & Subbase <strong>Valve</strong>s<br />

Options Information<br />

For optional features, note the valve model number that comes closest to the desired valve from the preceding order table. Change the model<br />

number as shown in the following diagram to obtain the desired option. For example: the ordering table on VAL-12-9 shows D1022C-00-CY, a 3-<br />

port/2-position valve with a solenoid operator, spring return and non-locking override. To use this valve with a locking override change the last two<br />

digits to CE, as shown below. To order operators with fluorocarbon elastomers, please contact Technical Services. See following page for optional<br />

operator voltages and connectors.<br />

Position in Model Number<br />

1 2 3 4 5 6 7 8 9 10<br />

D 1 0 2 2 C 0 0 C E<br />

Example model number is a 3-port/2-position (3-way) valve<br />

with a solenoid operator, spring return, and locking override.<br />

7 Indicator Pin (Basic 1/2" valve)<br />

8 Indicator Pin (Basic 1" valve)<br />

Optional Operator for<br />

Basic 1/4" & 1/2" <strong>Valve</strong>s<br />

Locking override,<br />

C F<br />

low wattage<br />

Weight<br />

lbs. (kg)<br />

1.00 (0.45)<br />

J Vacuum Service † Optional Operator Classification: CY, CC, CE, CF, P1: IP65<br />

Vacuum Service †<br />

For on-off application of vacuum, use a<br />

normally closed 2-port/2-position (2-way) valve.<br />

When the valve is actuated, vacuum will be<br />

applied to the outlet port.<br />

For selecting alternately between vacuum and<br />

pressure, use a normally open 3-port/2-position<br />

(3-way) valve. Connect the vacuum to the exhaust<br />

port and pressure to the inlet port. When the<br />

valve is actuated, vacuum will be applied to the<br />

outlet port.<br />

For selecting alternately between vacuum and<br />

vent, use a normally open 3-port/2-position (3-<br />

way) valve. Connect the vacuum to the exhaust<br />

port and vent the inlet port. When the valve is<br />

actuated, vacuum will be applied to the outlet<br />

port.<br />

In addition, a 4-port/2-position (4-way) valve<br />

can be connected the same way as 3-port/2-<br />

position (3-way) valves for selecting alternately<br />

between vacuum and pressure or vacuum and<br />

vent. That is, connect the vacuum to the exhaust<br />

port and pressure or vent to the inlet port. When<br />

the valve is actuated, the cylinder ports (outlets)<br />

will be alternately switched between vacuum and<br />

pressure or vacuum and vent.<br />

Optional Solenoid Operators**<br />

C 0<br />

C 1<br />

P 1<br />

1/2" NPT conduit<br />

without override<br />

1/2" NPT conduit,<br />

locking override<br />

1/2" NPT conduit,<br />

non-locking override<br />

Weight<br />

lbs. (kg)<br />

1.11 (0.50)<br />

2.05 (0.93)<br />

1/2" NPT conduit,<br />

X 1 hazardous location, 1.57 (0.71)<br />

locking override<br />

(NEMA 4); C0, C1: IP30 (NEMA 1); X1: EEx d 11B T4<br />

(NEMA 7C, 7D, 8C, 8D, 9E and 9G. Solenoids using<br />

specified optional coils, meet the requirements of<br />

Underwriters Laboratories and Canadian Standards<br />

Association for use in hazardous locations as defined in the<br />

National Electric Code (ANSI CI): Class I, Groups C & D;<br />

Class II, Groups E, F & G.<br />

Power Requirements: CC: 8 WDC; 8 WAC; CE, CY: 6 WDC, 7<br />

WAC; CF: 2 WDC, 3.5 WAC; C0, C1, P1, X1: 12 W<br />

** Orifice Diameter: C0, C1, X1: 1.2mm (3/64")<br />

Pilot Supply: Internal (Convertible to External)<br />

Solenoid Exhaust Port: P1: 1/8" PTF; X1: 10-32 UNF;<br />

C0, C1: Not Threaded.<br />

To calculate the weight of a valve and optional operator take the weight given for the relevant valve from the ordering tables, subtract either 1.65 lbs (0.75 kg) for a<br />

CC operator, or 1.00 lbs. (0.45 kg) for a CE or CY operator, and add the weight given above for the appropriate optional operator.<br />

For example: For D1022C-00-CY has a listed weight of 2.50 lbs (1.13 kg). To convert this from a non-locking override to a hazardous location, locking override, i.e.<br />

D1022C-00-X1 ➔ 1.13 - 1.00 + 1.57 = 1.70 kg (3.74 lbs).<br />

Littleton, CO USA Phone: 303-794-2611 www.norgren.com VAL-12-13