D:\Carol\My Documents\PDBs\PDRC
D:\Carol\My Documents\PDBs\PDRC
D:\Carol\My Documents\PDBs\PDRC
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
®<br />
HEATING • AIR CONDITIONING<br />
Indoor Coil Specifications & Dimensions** (continued):<br />
CCA--FCC, CHA--TCC & CHA--TXC Cased Coils<br />
CCA18FCC<br />
CCA24FCC<br />
CHA18TCC<br />
CCA30FCC<br />
CCA30FDC<br />
CHA24TCC<br />
CHA24TXC<br />
CCA36FCC<br />
CCA36FDC<br />
CCA36FKC<br />
CHA30TCC<br />
CHA30TXC<br />
CCA42FCC<br />
CCA42FDC<br />
CHA36TCC<br />
CHA365TXC<br />
CCA48FCC<br />
CCA48FDC<br />
CHA42TXC<br />
CHA42TXC<br />
CCA54FCC<br />
CHA48TCC<br />
CCA57FCC<br />
CHA54TCC<br />
CCA60FCC<br />
CHA57TCC<br />
CHA60TCC<br />
CHA60TXC<br />
Evaporator Coil<br />
Face Area (Sq. Ft.) 2.81 2.81 3.75 3.75 4.22 4.69 5.16 5.16 5.63 5.63<br />
Rows 2 3 2 3 3 3 2 3 3 4<br />
FPI 16 14 16 14 13 13 16 14 14 15<br />
Drain Connections<br />
Primary 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT<br />
Auxiliary 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT<br />
Refrig. Line Connection<br />
Liquid (1) 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"<br />
Vapor (1) 5/8" 5/8" 3/4" 3/4" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8"<br />
Shipping Weight (lbs.) 34 39<br />
43<br />
46 (FDC)<br />
50<br />
53 (FDC)<br />
58 (FKC)<br />
54<br />
57 (FDC)<br />
58<br />
62 (FDC)<br />
(1) Refer to Outdoor Unit Specification Sheet for proper refrigeration line sizes. Use an adapter to fit connection to tubing size, if necessary.<br />
64 71 73 89<br />
Cabinet<br />
Width<br />
(W)<br />
Small<br />
(16 -1/2)<br />
Medium<br />
(20-1/2)<br />
Large<br />
(24-1/2)<br />
CCA--F*C CHA--TCC CHA--TXC<br />
CCA18FCC<br />
Cabinet Height<br />
(H)<br />
CCA24FCC CHA18TCC 14-1/4<br />
CCA30FCC CHA24TCC CHA24TXC<br />
CCA36FCC CHA30TCC CHA30TXC<br />
CCA42FCC CHA36TCC CHA36TXC 22-1/4<br />
CCA30FDC<br />
CCA36FDC<br />
CCA42FDC<br />
CCA48FCC CHA42TCC CHA42TXC<br />
CCA36FKC<br />
CCA48FDC<br />
CCA54FCC<br />
CCA57FCC<br />
CCA60FCC<br />
Horizontal Standard Efficiency Orifice Control Coils<br />
Cased A-Coil Models<br />
CHA48TCC<br />
CHA54TCC<br />
CHA57TCC<br />
CHA60TCC<br />
CHA60TXC<br />
18-1/4<br />
22-1/4<br />
26-1/4<br />
DIMENSION (inches)<br />
Left Air Opening<br />
(A X B)<br />
15 X 18-3/4<br />
19 X 18-3/4<br />
23 X 18-3/4<br />
All air opening flanges are 3/4" except for the two adjacent to the access panel. The flange to the right is 3/16" and the one to the left is 1-5/16".<br />
Right Air Opening<br />
(A X C)<br />
15 X 30-3/16<br />
19 X 20-3/16<br />
23 X 20-3/16<br />
BBA/BBC Matching<br />
Blower Coils<br />
Matches With:<br />
BBA24A2A<br />
BBA36A2A<br />
BBC24A2A<br />
BBA48A2A<br />
BBA60A2A<br />
BBC60A2A<br />
21 1/8<br />
B (Top) or<br />
C (Bottom)<br />
A<br />
H<br />
2<br />
H<br />
7<br />
4 3/4<br />
W<br />
** All dimensions in inches<br />
1 5/8<br />
2 3/4<br />
2<br />
W<br />
1<br />
6