Proportional <strong>Valves</strong><br />

PDB10P-01<br />

Pressure Relief, Pilot Operated, Spool Type<br />

31 gpm (120 l/min) • 5000 psi (350 bar)<br />

Hydraulic Symbol<br />

1<br />

Description<br />

A screw-in cartridge, pilot operated, spool type, pressure relief valve, intended<br />

for use as a pressure limiting device. This valve can be infinitely adjusted across<br />

a specified range using a variable electric input. Pressure output is proportional<br />

to DC current input.<br />

2<br />

Operation<br />

The PDB10P-01 blocks flow from port 1 to port 2 until sufficient pressure is<br />

reached at port 1 to open the pilot stage by offsetting the electrically induced<br />

solenoid force. The pilot stage opens and allows flow from the back of the main<br />

piston to port 2. The resulting pressure imbalance causes the main spool to move<br />

against the return spring and allows flow from port 1 to port 2.<br />

Electrical current increase will increase the relief pressure setting. With no current<br />

applied to the solenoid, the valve will relieve at approximately 75 psi.<br />

Features<br />

• Excellent stability throughout flow range<br />

• 12 and 24 volt proportional waterproof coils<br />

• Screen on pilot orifice to enhance safety<br />

• Manual override option<br />

Performance<br />

% of Maximum Relieving Pressure<br />

125<br />

100<br />

75<br />

50<br />

25<br />

1<br />

2<br />

Measured at 158 SUS (34 cSt)<br />

= 115°F (46°C)<br />

T Oil<br />

0<br />

10 20 30 40 50 60 70 80 90 100<br />

% of Maximum Control Current<br />

Specifications<br />

Operating Pressure 5000 psi (350 bar) max at port 2<br />

Nominal Flow<br />

31 gpm (120 l/min)<br />

Maximum Pilot Flow<br />

3.75 cu in/min. (0.5 l/min)<br />

Relieving Pressure Ranges<br />

(0 to maximum control current)<br />

75 to 870 psi (5 to 60 bar)<br />

75 to 3300 psi (5 to 230 bar)<br />

75 to 5000 psi (5 to 350 bar)<br />

Maximum Control Current 2.1 amps for 12VDC coil (2.2 Ohms)<br />

1.05 amps for 24VDC coil (8.8 Ohms)<br />

Dither Frequency<br />

160 to 250 Hz<br />

Hysteresis With Dither<br />

2-4% of maximum control current<br />

Typical Step Response Time ON: approx 50 ms, OFF: approx. 30 ms<br />

Repeatability<br />