Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Audible signaling devices<br />
Connection diagrams<br />
SON 2 DS 5 / DS 10 AC version DS 5 / DS 10 DC version<br />
External tone control<br />
tone 2: terminal 2 connected to ‘-‘<br />
tone 3: terminal 1 connected to ‘-‘<br />
Operating voltage<br />
connection<br />
Optional:<br />
volume control for<br />
DS 5<br />
Operating voltage<br />
connection<br />
(double pole)<br />
Tone selection<br />
(see table on<br />
page 131 for tone<br />
selection switch<br />
settings)<br />
115 V<br />
230 V<br />
AC<br />
L<br />
N<br />
PE<br />
X1<br />
Code switch for setting the tone<br />
Optional: progra<strong>mm</strong>ing mode<br />
for external tone selection<br />
L<br />
N<br />
PE<br />
Optional:<br />
external tone selection<br />
stage 2, 3 and 4<br />
12-48V DC<br />
24V AC<br />
X1<br />
for the supply of additional<br />
sounders; max. 10 of type<br />
DS 10 or max. 15 of type<br />
DS 5<br />
PA 130<br />
Connecting terminals (removable)<br />
Audio input<br />
0 dB 600 Ω<br />
Temperature sensor<br />
Code switch II<br />
1: audio:<br />
switch 1 to ON: activation of the terminal resistor<br />
(120 Ω) for cable monitoring<br />
- audio input 0 dB 600 Ω<br />
2: not used (normally set to OFF)<br />
3: cable monitoring<br />
switch 3 to ON: activation of the resistor (4K7) for<br />
cable monitoring (DC devices only)<br />
4: auxiliary relay<br />
switch 4 to ON: malfunction message output<br />
switch 4 to OFF: activation of additional devices<br />
Malfunction message-/<br />
aux. relay NO/NC<br />
Operating voltage<br />
24 V (48 V DC)<br />
External tone selection<br />
L3-L5<br />
L3<br />
L4<br />
L5<br />
L6<br />
Tone<br />
selection<br />
Code switch I<br />
Self-test:<br />
switch 7 to OFF:<br />
activation of the<br />
self-test every 24 hrs<br />
(operating voltage,<br />
amplifier, driver, tone<br />
test - duration 2 s)<br />
LED‘s - OFF during troule-free operation<br />
operating voltage failure<br />
overheating<br />
driver not operating<br />
not used<br />
Normally<br />
set to ON<br />
Connecting<br />
terminals<br />
AC version<br />
Examples for external tone selection<br />
Setting of code<br />
switch I according<br />
to line 59<br />
Customer application<br />
Relay energised during trouble-free operation<br />
NO<br />
Factory setting<br />
Connecting<br />
terminals<br />
NC<br />
tone SW1 SW2 SW3 SW4<br />
-<br />
51 x<br />
52 x<br />
53 x<br />
54 x<br />
audio x x<br />
55 x x<br />
– x x<br />
56 x x<br />
x = closed<br />
150<br />
www.pfannenberg.com