All manhole covers, seating frames, and adapter rings shall be machined to a firm and even<br />

bearing and fit truly into the frames. The manufacturer’s name shall be cast upon the manhole<br />

covers and frames.<br />

NEENAH<br />

EAST JORDAN<br />

Catch Basin Castings <strong>Xenia</strong> Type 2<br />

1. Chairback Curb 1-inch radius R-3290 Grate Type C or L 7380 – T1 Grate M2 or M6<br />

2. Chairback Curb 3-inch radius R-3290 Grate Type C or L 7380 – T1 Grate M2 or M6<br />

3. Barrier Curb R-3290 Grate Type C or L 7380 – T1 Grate M2 or M6<br />

4. Roll Curb R-3290-D Grate Type C or L 7030 – T2 Grate M2 or M6<br />

5. Drive Approach R3290-A Grate Type C 7034 – Grate Type M2 or M6<br />

6. Roll Drive Approach R3290-A Grate Type C 7030 – T3 Grate M2 or M6<br />

Catch Basin Casting <strong>Xenia</strong> Type 3 R-3295-2 Grate Type C or L 7031 – T1 Grate Type M2 or M6<br />

<strong>Xenia</strong> Type 3 Roll Curb R-3295-2-D 7031 – T2 Grate Type M2 or M6<br />

Catch Basin 2-2-B R-4852 5115 – M2<br />

Manhole Casting R-1767 VENTED LID 1600 VENTED LID<br />

Manhole Casting Water Tite R-1916-D 1600 Water Tite<br />

15.8 Chimney Seals - Chimney Seals may be required as determined by the <strong>City</strong> Engineer or the<br />

Engineer’s Representative.<br />

15.9 Drop Assemblies (See Standard Drawing #203) - Drop assemblies shall be installed where<br />

the change in elevation <strong>of</strong> pipes through a manhole exceeds 24-inches. Drop manhole assemblies<br />

shall consist <strong>of</strong> a standard tee <strong>of</strong> the main line pipe, line diameter with the spur diameter as<br />

specified on the drawings. The riser pipe, the standard short elbow, and the short hob section<br />

shall be the same material as the main line. The entire assembly shall be encased in a minimum<br />

<strong>of</strong> 5-inches <strong>of</strong> concrete, reinforced and anchored to manhole with 1-inch diameter reinforcing<br />

bars. Reinforcement shall be shown on the construction drawings. Drop assemblies shall be<br />

constructed on the outside <strong>of</strong> the manhole.<br />

15.10 Venting Assemblies - Manhole venting assemblies shall be constructed <strong>of</strong> 4-inch ductile<br />

iron pipe and fittings. The locations <strong>of</strong> venting assemblies with the individual length <strong>of</strong> run and<br />

height <strong>of</strong> rise and elevation <strong>of</strong> vent are shown on the construction drawings.<br />

15.11 Swing Check Valves All new construction shall install a swing check valve if any <strong>of</strong> the<br />

following criteria has been met or at the discretion <strong>of</strong> the <strong>City</strong> <strong>of</strong> <strong>Xenia</strong>.<br />

1. The building has a basement or crawl space within 250 ft <strong>of</strong> a known 100 year flood<br />

boundary.<br />

2. The building has a basement, crawl space, or finish floor elevation within 5 ft <strong>of</strong> a<br />

known 100 year base flood elevation.<br />

The swing check valve must meet the requirements <strong>of</strong> the <strong>City</strong> <strong>of</strong> <strong>Xenia</strong> and/or Greene County<br />

Plumbing Inspection. The swing check valve installation must be installed in a manor that allows<br />