When necessary, compact subgrade surfaces to density requirements for the backfill material<br />

and prepare subgrade or previous layer of compacted fill prior to placement of additional fill<br />

by scarifying or disking.<br />

Cut out soft areas of subgrade not readily capable of in situ compaction. Backfill with<br />

subsoil and compact to density equal to requirements for subsequent backfill material.<br />

Backfill areas to contours and elevations. Use materials that are not frozen. The Contractor<br />

shall keep the foundation and subgrade free from water or unacceptable materials after the<br />

fill operations have started.<br />

Backfill systematically, as early as possible, to allow minimum time for natural settlement.<br />

Do not backfill over porous, wet, or spongy subgrade surfaces.<br />

Place and compact soil fill materials in continuous layers not exceeding eight (8) inches loose<br />

depth. Compact soil fill materials to 95 percent of maximum dry density. Field density tests<br />

shall be performed on each lift. Areas that fail to meet the requirements will be reworked as<br />

necessary to meet the requirements and then tested again. This process shall be repeated<br />

until the compaction requirements are met.<br />

Tests shall be performed on each 400 square feet of surface area and on each lift of the<br />

surface area.<br />

Maintain optimum moisture content of backfill material to attain required compaction density<br />

as specified. Material deposited on the fill that is too wet shall be removed or spread and<br />

permitted to dry, assisted by disking or blading, if necessary, until the moisture content is<br />

reduced to the specified limits.<br />

All crushed stone fill and crushed stone backfill under structures and pavements adjacent to<br />

structures shall be DGA crushed stone per Kentucky Highway Department Standard<br />

Specifications for Road and Bridge Construction, unless indicated otherwise. Stone fill and<br />

backfill materials shall be placed in layers not exceeding six (6) inches in thickness and<br />

compacted to 95 percent of maximum dry density.<br />

Backfill shall not be placed against or on structures until they have attained sufficient<br />

strength to support all loads to which subjected without distortion, cracking, or damage.<br />

Deposit soil evenly around the structure.<br />

Slope grade away from structures minimum two (2) inches in ten (10) feet, unless noted<br />

otherwise.<br />

Make changes in grade gradual. Blend slopes into level areas.<br />

Remove surplus excavation materials to designated areas.<br />

STORMWATER MANUAL 10-25 January 1, 2009<br />