Introducti<strong>on</strong><br />

Refrigerant Handling<br />

Refrigerant Safety<br />

Mobile air c<strong>on</strong>diti<strong>on</strong>ing systems c<strong>on</strong>tain chemical mixtures that<br />

require special handling to avoid injury and to avoid venting<br />

refrigerant into the atmosp<str<strong>on</strong>g>here</str<strong>on</strong>g>.<br />

Do not discharge any refrigerant gas, vapor or liquid from a<br />

refrigerati<strong>on</strong> system into the atmosp<str<strong>on</strong>g>here</str<strong>on</strong>g>. If service is required<br />

that involves opening the refrigerant system, use a certified<br />

recovery system.<br />

• Wear safety goggles and protective gloves, user<br />

and bystander. Everyday eyeglasses <strong>on</strong>ly have<br />

impact resistant lenses, they are NOT safety<br />

glasses. the If any refrigerant gets into eyes,<br />

flush with water and seek a doctor's aid<br />

immediately, even though irritati<strong>on</strong> may cease.<br />

• Do not remove master filter while under pressure.<br />

Follow instructi<strong>on</strong>s for removing master filter. For<br />

additi<strong>on</strong>al informati<strong>on</strong> refer to Chapter<br />

3–Changing the Master Filter.<br />

• Prevent refrigerant from c<strong>on</strong>tacting the skin.<br />

• Read, understand and follow Safety Informati<strong>on</strong> in<br />

the fr<strong>on</strong>t of this manual.<br />

• Use your Kool Kare unit in locati<strong>on</strong>s with<br />

mechanical ventilati<strong>on</strong> providing at least four air<br />

changes per hour.<br />

• Avoid breathing air c<strong>on</strong>diti<strong>on</strong>ing refrigerant and<br />

lubricant vapor or mist.<br />

• Do not allow refrigerant to c<strong>on</strong>tact open flame or<br />

be drawn into a running engine. This can cause<br />

refrigerant to become pois<strong>on</strong>ous phosgene gas.<br />

• Use your Kool Kare unit to remove refrigerant<br />

from air c<strong>on</strong>diti<strong>on</strong>ing systems.<br />

• Read, understand and follow Safety Informati<strong>on</strong> in<br />

the fr<strong>on</strong>t of this manual.<br />

Tighten all tubing and hose c<strong>on</strong>necti<strong>on</strong>s properly.<br />

Insufficient or excessive torque can result in loose<br />

joints or deformed parts. Either c<strong>on</strong>diti<strong>on</strong> can result<br />

in refrigerant leakage.<br />