Installati<strong>on</strong> and Operati<strong>on</strong><br />
9. Select CONTINUE. The following messages display:<br />
WAITING FOR STABLE SCALE!<br />
RECYCLING REFRIGERANT FROM VEHICLE!<br />
— The refrigerant c<strong>on</strong>tinues to recycle until the virgin<br />
tank valve is closed, or the virgin tank is empty.<br />
— If t<str<strong>on</strong>g>here</str<strong>on</strong>g> is air in the recovery tank when the recycling<br />
process is completed the following message<br />
displays:<br />
PURGING AIR FROM TANK!<br />
3 A pulsed gas escaping sound emits while purging n<strong>on</strong>c<strong>on</strong>densable<br />
gasses and moisture from the system at<br />
the end of the recycling process. Do not be alarmed by<br />
this noise or defeat this process.<br />
— When the process is complete the following message<br />
displays:<br />
COMPLETED!<br />
10. Close the virgin tank valve, blue (low) service hose<br />
coupler and c<strong>on</strong>trol panel hand valve.<br />
11. Remove the hose from the virgin tank.<br />
2-5