Fryer Mill with Anilam 6000 and 20KVA Transformer<br />
Setup<br />
The Anilam 6000 control requires special secondary voltage of 400 vac. This requires a<br />
special transformer to be installed on all mills equipped with this control. The 20KVA<br />
transformer is used on all mills except ones with the 30 Horsepower spindle option. The<br />
transformer is pre-wired at the factory for the primary voltage specified at time of order<br />
and the machine serial number tag.<br />
Main input power must ONLY be connected to the line side (TOP) of the disconnect<br />
switch located inside the electrical cabinet. NEVER connect main power directly to the<br />
Transformer. Following is an explanation of how to configure the transformer (all wiring<br />
changes are done inside the transformer) for the two most common incoming primary<br />
voltage ranges. Refer to the specifications on the front cover of the transformer for other<br />
possible inputs (210 – 483 V).<br />
For 208-250 VAC input (Voltage must be within this range or warranty will be void.),<br />
connect the internal tap wires from H1-H2-H3 to each corresponding tap (4=250, 5=230,<br />
6=210) respectively (one wire per phase). The 3- 12 AWG black wires labeled as 13-14-<br />
15 should be connected to H1, H2, H3 respectively alongside with the input AC wires<br />
ONLY when 208 – 250 volt primary is used.<br />
For 420-495 VAC input (Voltage must be within this range or warranty will be void),<br />
connect the internal tap wires from H1-H2-H3 to each corresponding tap (1=483, 2=460,<br />
3=437) respectively (one wire per phase). The 3- 12 AWG black wires labeled as 13-14-<br />
15 should be connected to X1-13, X2-14, X3-15<br />
Electrical <strong>Manual</strong> Anilam 6000i.doc Page 9 of 25