7613 EXT_19 Input Num 2 8 0<br />

7614 EXT_20 Input 1 0502 7C3B 0000 HEX<br />

7615 EXT_21 Input 2 0500 7C3B 0000 HEX<br />

7616 EXT_22 Input 3 - 7C3B 0000 HEX<br />

7617 EXT_23 Input 4 - 7C3B 0000 HEX<br />

7618 EXT_24 Input 5 - 7C3B 0000 HEX<br />

7619 EXT_25 Input 6 - 7C3B 0000 HEX<br />

761A EXT_26 Input 7 - 7C3B 0000 HEX<br />

761B EXT_27 Input 8 - 7C3B 0000 HEX<br />

COM-01 [Opt B/D]<br />

• Indicates <strong>Option</strong> <strong>board</strong>s installed. This value is automatically set when the <strong>board</strong>s are installed.<br />

COM-02 [ Opt Version ]<br />

• Displays version of <strong>Option</strong> Board.<br />

COM-09 [ Profi MAC ID ]<br />

• Sets MAC ID of profibus. The MAC ID must have a unique value in network.<br />

COM-10 [ Output Num ]<br />

• Sets the number of Read area address only.<br />

• Arrange EXT #11~18 for using and set 1 ~ 8<br />

COM-19 [ Input Num ]<br />

• Sets the number of Write area address only.<br />

• Arrange EXT #20~27 for using and set 1 ~ 8