Shimaden, Temperature and Humidity Control Specialists<br />

°C<br />

%RH<br />

SERIES PAC15<br />

SINGLE PHASE POWER REGULATOR<br />

BASIC FEATURES<br />

Phase Angle <strong>or</strong> Zero Voltage Switch<strong>in</strong>g<br />

Current Capacity: 20~100 Amperes<br />

Power Supply: 100~120 / 200~240V AC<br />

SPECIFICATIONS<br />

Control Mode:<br />

Phase angle (PAC15P)<br />

Zero voltage switch<strong>in</strong>g (PAC15C)<br />

Possible Loads:<br />

All resistance loads (PAC15P)<br />

Constant resistance loads (PAC15C)<br />

Power Supply Cycle:<br />

50/60Hz. (<strong>in</strong>ternally selectable-PAC15P)<br />

50/60Hz. common (PAC15C)<br />

Output Voltage Control Range: 0~95% m<strong>in</strong>. 50/60Hz. of <strong>in</strong>ut voltage (PAC15P)<br />

0~95% m<strong>in</strong>. of load power (PAC15C)<br />

Power Lamp:<br />

Green LED lamp (PAC15P)<br />

Output Indication:<br />

Green LED lamp (when load 'ON'-PAC15C)<br />

Current Capacity:<br />

20, 30, 45, 60, 80 and 100 Amps.<br />

Power Supply: 100~120V/200~240V AC ± 10%<br />

Control Input:<br />

Current = 4~20mA DC (Receiv<strong>in</strong>g impedance: 100 ohms)<br />

Contact = Zero voltage contact<br />

Power Adjuster:<br />

Current <strong>in</strong>put = Internal <strong>in</strong>stallation as standard (External <strong>in</strong>stallation as option)<br />

Contact <strong>in</strong>put = External <strong>in</strong>stallation as standard<br />

Auto/Manual Power Adjuster: Only current <strong>in</strong>put type is available - optional<br />

Thyrist<strong>or</strong> Element Cool<strong>in</strong>g: Natural air<br />

Over-Current Protection:<br />

None available (Use a fuse f<strong>or</strong> semiconduct<strong>or</strong>)<br />

M<strong>in</strong>imum Load:<br />

0.5 Amps<br />

Operat<strong>in</strong>g Ambient<br />

Temperature and Humidity: -10~50°C, 90%RH maximum<br />

Insulation Resistance:<br />

500V DC 20M ohms between power supply term<strong>in</strong>als and chassis<br />

500V DC 20M ohms between power supply term<strong>in</strong>als and <strong>in</strong>put term<strong>in</strong>als<br />

Dielectric Strength:<br />

1 m<strong>in</strong>. at 2000V AC between power supply term<strong>in</strong>als and chassis<br />

Dimensions and Weight: See page 4.


ORDERING INFORMATION<br />

Series PAC15<br />

ITEMS<br />

SERIES<br />

CONTROL INPUT<br />

CURRENT CAPACITY<br />

POWER SUPPLY<br />

CODE<br />

EXTERNAL POWER ADJUSTER<br />

REMARKS<br />

PAC15P<br />

PAC15C<br />

0<br />

2<br />

9<br />

020<br />

030<br />

045<br />

060<br />

080<br />

100<br />

81–<br />

99–<br />

N<br />

P<br />

M<br />

B<br />

W<br />

Y<br />

P<br />

B<br />

X<br />

0<br />

9<br />

SPECIFICATIONS<br />

Phase Angle S<strong>in</strong>gle Phase Power Regulat<strong>or</strong><br />

Cycle Base Zero Voltage Switch<strong>in</strong>g S<strong>in</strong>gle Phase Power Regulat<strong>or</strong><br />

4~20mA DC, Receiv<strong>in</strong>g impedance: 100Ω<br />

Non-voltage contact<br />

Others (Please consult bef<strong>or</strong>e <strong>or</strong>der<strong>in</strong>g.)<br />

20A<br />

30A<br />

45A<br />

60A<br />

80A<br />

100A<br />

100~120V / 200~240V AC ±10%, 50 / 60Hz<br />

Others (Please consult bef<strong>or</strong>e <strong>or</strong>der<strong>in</strong>g.)<br />

None (Internal <strong>in</strong>stallation as standard)<br />

External power adjuster<br />

Manual power adjuster<br />

Base power adjuster<br />

External power adjuster + manual power adjuster<br />

External power adjuster + base power adjuster<br />

High power adjuster (standard)<br />

High power adjuster (standard) + Low power adjuster<br />

Others (Please consult bef<strong>or</strong>e <strong>or</strong>der<strong>in</strong>g.)<br />

Without<br />

With (Please consult bef<strong>or</strong>e <strong>or</strong>der<strong>in</strong>g.)<br />

Current<br />

<strong>in</strong>put<br />

Contact<br />

<strong>in</strong>put<br />

TERMINALS & WIRING (CURRENT INPUT TYPE)<br />

Control Signal<br />

4 ~ 20mA DC<br />

+<br />

−<br />

1<br />

2<br />

C1<br />

C2<br />

Control Input Term<strong>in</strong>als<br />

External Power<br />

Adjuster<br />

B 10k<br />

1<br />

3<br />

2<br />

3<br />

4<br />

5<br />

R1<br />

R2<br />

R3<br />

Power Adjuster Term<strong>in</strong>als<br />

when used, <strong>in</strong>ternal power<br />

adjuster at maximum.<br />

when not used, R2-R3 sh<strong>or</strong>t-circuited.<br />

6<br />

M<br />

Manual Power Adjust Term<strong>in</strong>al<br />

7<br />

8<br />

RA<br />

T1<br />

0V AC<br />

100 ~ 120V AC<br />

Control Circuit Power<br />

Input Term<strong>in</strong>als<br />

9<br />

T2<br />

200 ~ 240V AC<br />

GND<br />

Earth<strong>in</strong>g Term<strong>in</strong>als<br />

R<br />

U<br />

Rapid Fuse<br />

Power<br />

Supply<br />

200 ~ 240V AC<br />

Load<br />

POWER ADJUSTER CONNECTIONS (CURRENT INPUT TYPE)<br />

Auto / Manual Selectable<br />

Base Power Control<br />

External Power Adjust / Base Power Adjust<br />

C1 C2 R1 R2 R3 M<br />

1 2 3 4 5 6<br />

Control Signal<br />

4 ~ 20mA DC<br />

External Power<br />

Adjuster<br />

Manual Power<br />

Adjuster<br />

Auto<br />

Internal power adjuster = maximum<br />

1<br />

Manual<br />

1<br />

2<br />

2<br />

3<br />

C1 C2 R1 R2 R3 M<br />

1 2 3 4 5 6<br />

1<br />

2<br />

Control Signal<br />

4 ~ 20mA DC<br />

Base Power<br />

Adjuster<br />

Power adjustment can be done with<br />

Internal power adjuster.<br />

3<br />

C1 C2 R1 R2 R3 M<br />

1 2 3 4 5 6<br />

External Power<br />

2<br />

Control Signal<br />

1<br />

3<br />

4~20mA DC<br />

2 1<br />

Base Power<br />

External power adjuster and base power<br />

adjuster c<strong>or</strong>respond with each other.<br />

Internal power adjuster = at maximum<br />

3


TERMINALS & WIRING (CONTACT INPUT TYPE)<br />

Series PAC15<br />

1. N<strong>or</strong>mal Control<br />

Control Signal<br />

+<br />

−<br />

1<br />

2<br />

C1<br />

C2<br />

Control Input Term<strong>in</strong>als<br />

External Power<br />

Adjuster<br />

B 10k<br />

1<br />

3<br />

2<br />

3<br />

4<br />

R1<br />

R2<br />

External Power Adjuster Term<strong>in</strong>als<br />

when not used, R1-R3 sh<strong>or</strong>t-circuited.<br />

5<br />

R3<br />

6<br />

7<br />

8<br />

RA<br />

T1<br />

0V AC<br />

100 ~ 120V AC<br />

Control Circuit Power<br />

Input Term<strong>in</strong>als<br />

9<br />

T2<br />

200 ~ 240V AC<br />

GND<br />

Earth<strong>in</strong>g Term<strong>in</strong>als<br />

R<br />

U<br />

Rapid Fuse<br />

Power<br />

Supply<br />

100 ~ 120V AC<br />

Load<br />

2. High/Low Control<br />

Control Signal<br />

High Power<br />

Adjuster<br />

B 10k<br />

Low Power<br />

Adjuster<br />

B 10k<br />

1<br />

1<br />

+<br />

−<br />

3<br />

2<br />

3<br />

2<br />

1<br />

2<br />

3<br />

4<br />

5<br />

C1<br />

C2<br />

R1<br />

R2<br />

R3<br />

Control Input Term<strong>in</strong>als<br />

External Power Adjuster Term<strong>in</strong>als<br />

Output when high power adjust/contact (C1-C2=ON)<br />

0~100% power output control available by high<br />

power adjuster.<br />

Output when low power adjust/contact=OPEN<br />

Low Power Output=<br />

High Power Value+Low Power Value-100%<br />

(When output of low power is (-),<br />

low power output is zero.)<br />

6<br />

7<br />

8<br />

RA<br />

T1<br />

0V AC<br />

100 ~ 120V AC<br />

Control Circuit Power<br />

Input Term<strong>in</strong>als<br />

9<br />

T2<br />

200 ~ 240V AC<br />

GND<br />

Earth<strong>in</strong>g Term<strong>in</strong>als<br />

R<br />

U<br />

Rapid Fuse<br />

Power<br />

Supply<br />

100 ~ 120V AC<br />

Load<br />

CONTROL MODES & WAVE FORM<br />

Item<br />

Noise<br />

Control Mode<br />

Phase Angle Little<br />

Control (P)<br />

Mov<strong>in</strong>g Coil<br />

Deflection<br />

Cont<strong>in</strong>uous<br />

Heat<strong>in</strong>g Element<br />

Capacity<br />

Very Small<br />

Output Wave F<strong>or</strong>m<br />

10% Output 50% Output 90% Output<br />

Zero-voltage<br />

Switch<strong>in</strong>g<br />

Control (C)<br />

None<br />

Low Output/<br />

Large Deflection<br />

Mid ~ High<br />

Output/Almost<br />

Cont<strong>in</strong>uous<br />

Small<br />

1 cycle ON and 9<br />

cycle OFF<br />

1 cycle ON and 1cycle<br />

OFF cont<strong>in</strong>uously<br />

9 cycle ON and 1<br />

cycle OFF<br />

PAC15 Series Total Heat<strong>in</strong>g Value<br />

Capacity<br />

20 A 30 A 45 A 60 A 80 A 100 A<br />

Recommended mount<strong>in</strong>g<br />

100mm m<strong>in</strong>imum<br />

Heat<strong>in</strong>g Value<br />

24 W 36 W 48 W 60 W 84W 100 W<br />

*Care must be taken f<strong>or</strong> air-ventilation.<br />

*Vertical mount<strong>in</strong>g is recommended.<br />

When mount<strong>in</strong>g h<strong>or</strong>izontally, use at 70% of the current capacity.<br />

100mm m<strong>in</strong>imum<br />

30mm m<strong>in</strong>imum


EXTERNAL DIMENSIONS & WEIGHT<br />

Series PAC15<br />

20A & 30A Types<br />

45A & 60A Types<br />

68<br />

5.5<br />

120<br />

(96)<br />

70<br />

5.5<br />

152<br />

(129)<br />

PAC15-SERIES<br />

PAC15-SERIES<br />

15<br />

160<br />

170<br />

180<br />

190<br />

R<br />

U<br />

R<br />

U<br />

2-M4<br />

5.5<br />

13<br />

(98)<br />

Weight: Approx. 1.2 kg<br />

2-M5<br />

5.5<br />

16<br />

20<br />

(134)<br />

Weight: Approx. 2.0 kg<br />

80A & 100A Types<br />

123<br />

80<br />

2- 5.5<br />

162<br />

(139)<br />

PAC15-SERIES<br />

194<br />

204<br />

R<br />

U<br />

20<br />

2-M8 25 20<br />

17<br />

2-5.5<br />

3<br />

97 ~ 100<br />

Weight: Approx. 3.4 kg<br />

Unit: mm<br />

Warn<strong>in</strong>g<br />

• The PAC15 series is designed f<strong>or</strong> controll<strong>in</strong>g the power of a heater <strong>or</strong> similar equipment used <strong>in</strong> a general <strong>in</strong>dustrial<br />

facilities. (It is not to be used f<strong>or</strong> any purpose which regulates the prevention of serious effects on human life <strong>or</strong> safety.)<br />

Caution<br />

• If the possibility of loss <strong>or</strong> damage to your system <strong>or</strong> property as a result of failure of any part of the process exists, proper<br />

safety measures must be made bef<strong>or</strong>e the <strong>in</strong>strument is put <strong>in</strong>to use so as to prevent the occurrence of trouble.<br />

Temperature and Humidity Control Specialists<br />

PO Box 60, Thompson Ridge NY 10985<br />

Phone: (800) 49 - VESPO Fax: (800) 36 - VESPO<br />

E-MAIL: Controls@vespo.com URL: http://www.vespo.com