10.07.2015 Views

Download PDF (3.50 Mb) - Verotec

Download PDF (3.50 Mb) - Verotec

Download PDF (3.50 Mb) - Verotec

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CompactPCI 6U 8HP 400 WATT AC POWER SUPPLYFEATURESl 400W output powerl Efficiency - better than 81% @ High linel 85-264VAC Wide-Range Input with Unity PFCl Operation Temp. -5ºC to +55 ºC – No De-ratingl “Hot-Swap” Active Current share on V1 & V2l N+1 Full redundancy operationl No Minimum loading requirementl Standard PICMG® 47Pin Connectorl IEEE 1101.10 compliant form factorl Safety Per UL CSA & CE Markingl Meets FCC-68 Part 15 Class-B & EN-55022 Class-B with externalline filterl I2C Data Bus (optional) for PSU Hardware configurationDescriptionOrdercodeCPCI-AC-6U-400 (Vertical Overlay) 925-4004133CompactPCI 6U 8HP 400 WATT AC POWER SUPPLY11 Power SuppliesINPUT AC Input Voltage 85 - 264 VRMSDC Input VoltageInput Frequency RangeInput Inrush CurrentInput Reflected Ripple47 - 63 Hz (400Hz Option)Active Power Factor Correction EN 61000-2-3 >0.95Efficiency @ 230VACEfficiency @ 115VACEfficiency @ 48/24VDCInput Line Protection Non-User Serviceable FuseHold-up TimeCold Start 30A @ 110VAC & 60A @ 230VACFCC-68 part 15 & EN55022 Class B with the use of an external line filterFull Load 81%TypicalFull Load 79% TypicalFull Load16mSec @ Full LoadOUTPUT V1/Current +5VDC /50AV2/Current+3.3VDC / 80AV3/Current +12VDC / 7.5AV4/Current -12VDC / 1.5ATotal Output PowerLine Regulation +/- 0.5%Load RegulationV1&V2 +/- 1%V3&V4 +/- 5%Min. Load RequirementOvershoot/Undershoot at Turn-On Less than 1%Turn-On DelayInitial Setting Accuracy400W with 250LFM ( 500W With 400LFM - Safety Pending)No2Sec Max.Voltage Set point (Internal trim-pot) V1/V2 +/- 5%+/- 0.4% for V1 & V2 +/- 2% for V3 & V4Ripple @ Noise with 20MHz Bandwidth measured across 10uF Load Capacitor Paralleled with 0.1uF Ceramic Cap.+5VDC+3.3VDC60mV p-p60mV p-p+/- 12VDC 120mV p-pHot-SwapCurrent ShareRemote Sense (Open sense lines protected)Long Term StabilityTransient ResponseRecovers to 1% inOver-Voltage ProtectionOverload ProtectionV1 & V2V3V4Short Circuit ProtectionTemperature ProtectionYesSingle Wire - on V1 & V2On +5VDC & +3.3VDC0.1% over 10 Hours after 10min. Warm UpFor a step Load of 50%max Load peak transient < 5%. & outputLess than 0.5mSec.110% - 125% of V1,V2 & V3 with Latched Shut Down125% Max.200% Max.250% Max.Available On All OutputsExcess Temp will Shut Down the Unit - with Auto recovery11.18 UK Tel: +44 (0)2380-246900 sales@verotec.co.ukUSA Tel: 603.821.9921 sales@verotec.us

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!