10.07.2015 Views

Download PDF (3.50 Mb) - Verotec

Download PDF (3.50 Mb) - Verotec

Download PDF (3.50 Mb) - Verotec

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CompactPCI 3U 8HP 200 WATT 48VDC POWER SUPPLYFEATURESl 200W output powerl Efficiency - better than 83%l 36-72VDC Nominal Input Voltagel Operation Temp. -5ºC to +55 ºC – No De-ratingl “Hot-Swap” Active Current share on V1 & V2l N+1 Full redundancy operationl No Minimum loading requirementl Standard PICMG® 47Pin Connectorl IEEE 1101.10 compliant form factorl Safety Per UL CSA & CE Markingl Meets FCC-68 Part 15 Class-B & EN-55022 Class-B with externalline filterl On board E2PROM for PS H/W configurationDescriptionOrdercodeCPCI-DC-3U-200 (Horizontal Overlay) 925-4004122CPCI-DC-3U-200 (Vertical Overlay) 925-4004128CompactPCI 3U 8HP 200 WATT 48VDC POWER SUPPLYINPUTAC Input VoltageDC Input VoltageInput Frequency RangeInput Inrush CurrentInput Reflected RippleActive Power Factor CorrectionEfficiency @ 230VAC Full LoadEfficiency @ 115VAC Full LoadEfficiency @ 48/24VDC Full LoadInput Line ProtectionHold-up Time36 - 72 VDC20A MaxFCC-68 part 15 & EN55022 Class B with the use of an external line filter83% @ 48VDCNon-User Serviceable FuseOUTPUT V1/Current +5VDC / 25AV2/Current+3.3VDC / 36AV3/Current+12VDC / 3AV4/Current -12VDC / 0.5ATotal Output PowerLine Regulation +/- 0.5%Load RegulationV1&V2 +/- 1%V3&V4 +/- 5%200W with 250LFM11 Power SuppliesMin. Load RequirementNoOvershoot/Undershoot at Turn-On Less than 1%Turn-On Delay1Sec Max.Initial Setting Accuracy+/- 0.4% for V1 & V2 +/- 2% for V3 & V4Voltage Set point (Internal trim-pot) V1/V2 +/- 5%Ripple @ Noise with 20MHz Bandwidth measured across 10uF Load Capacitor Paralleled with 0.1uF Ceramic Cap.+5VDC60mV p-p+3.3VDC60mV p-p+/- 12VDC 120mV p-pHot-SwapYesCurrent ShareSingle Wire - on V1 & V2Remote Sense (Open sense lines protected) On +5VDC & +3.3VDCLong Term StabilityTransient ResponseOver-Voltage ProtectionOverload ProtectionShort Circuit ProtectionTemperature ProtectionV1 & V2 125% Max.V3V40.1% over 10 Hours after 10min. Warm UpFor a step Load of 50%max Load peak transient < 5%. & outputRecovers to 1% in Less than 0.5mSec.110% - 125% of V1,V2 & V3 with Latched Shut Down200% Max.250% Max.Available On All OutputsExcess Temp will Shut Down the Unit - with Auto recovery11.06 UK Tel: +44 (0)2380-246900 sales@verotec.co.ukUSA Tel: 603.821.9921 sales@verotec.us

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!