10.07.2015 Views

Download PDF (3.50 Mb) - Verotec

Download PDF (3.50 Mb) - Verotec

Download PDF (3.50 Mb) - Verotec

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CompactPCI 6U 8HP 500 WATT AC POWER SUPPLYFEATURESl 500W output powerl Efficiency - better than 81% @ High linel 85-264VAC Wide-Range Input with Unity PFCl Operation Temp. -5ºC to +55 ºC – No De-ratingl “Hot-Swap” Active Current share on V1 & V2l N+1 Full redundancy operationl No Minimum loading requirementl Standard PICMG® 47Pin Connectorl IEEE 1101.10 compliant form factorl Safety Per UL CSA & CE Markingl Meets FCC-68 Part 15 Class-B & EN-55022 Class-B with externalline filterl I2C Data Bus (optional) for PSU Hardware configurationDescriptionOrdercodeCPCI-AC-6U-500 (Vertical Overlay) 925-4004136CompactPCI 6U 8HP 500 WATT AC POWER SUPPLY11 Power SuppliesINPUT AC Input Voltage 85 - 264 VRMSDC Input VoltageInput Frequency RangeInput Inrush CurrentInput Reflected Ripple47 - 63 Hz (400Hz Option)Active Power Factor Correction EN 61000-2-3 >0.95Efficiency @ 230VAC Full LoadEfficiency @ 115VAC Full LoadEfficiency @ 48/24VDC Full LoadInput Line ProtectionHold-up TimeCold Start 35A @ 110VAC & 65A @ 230VACFCC-68 part 15 & EN55022 Class B with the use of an external line filter81%Typical79% TypicalNon-User Serviceable Fuse20mSec @ Full LoadOUTPUT V1/Current +5VDC /65AV2/Current+3.3VDC / 80AV3/Current+12VDC / 12AV4/Current -12VDC / 1.5ATotal Output PowerLine Regulation +/- 0.5%Load RegulationMin. Load RequirementV1&V2 +/- 1%V3&V4 +/- 5%500W With 400LFMOvershoot/Undershoot at Turn-On Less than 1%Turn-On DelayInitial Setting AccuracyNo2Sec Max.Voltage Set point (Internal trim-pot) V1/V2 +/- 5%+/- 0.4% for V1 & V2 +/- 2% for V3 & V4Ripple @ Noise with 20MHz Bandwidth measured across 10uF Load Capacitor Paralleled with 0.1uF Ceramic Cap.Hot-SwapCurrent Share+5VDC+3.3VDCRemote Sense (Open sense lines protected)Long Term StabilityTransient ResponseOver-Voltage ProtectionOverload ProtectionShort Circuit Protection60mV p-p60mV p-p+/- 12VDC 120mV p-pV1 & V2YesSingle Wire - on V1 & V2On +5VDC & +3.3VDC0.1% over 10 Hours after 10min. Warm UpFor a step Load of 50%max Load peak transient < 5%. & outputRecovers to 1% inLess than 0.5mSec.110% - 125% of V1,V2 & V3 with Latched Shut Down125% Max.V3 200% Max.V4Temperature Protection Excess250% Max.Available On All OutputsTemp will Shut Down the Unit - with Auto recovery11.22 UK Tel: +44 (0)2380-246900 sales@verotec.co.ukUSA Tel: 603.821.9921 sales@verotec.us

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!