10.07.2015 Views

Download PDF (3.50 Mb) - Verotec

Download PDF (3.50 Mb) - Verotec

Download PDF (3.50 Mb) - Verotec

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CompactPCI 3U 8HP 200 WATT 24VDC POWER SUPPLYFEATURESl 200W output powerl Efficiency - better than 78%l 18-36VDC Nominal Input Voltagel Operation Temp. -5ºC to +55 ºC – No De-ratingl “Hot-Swap” Active Current share on V1 & V2l N+1 Full redundancy operationl No Minimum loading requirementl Standard PICMG® 47Pin Connectorl IEEE 1101.10 compliant form factorl Safety Per UL CSA & CE Markingl Meets FCC-68 Part 15 Class-B & EN-55022 Class-B with externalline filterl On board E2PROM for PS H/W configurationDescriptionOrdercodeCPCI-DC-3U-200/24 (Horizontal Overlay) 925-4004123CPCI-DC-3U-200/24 (Vertical Overlay) 925-4004129CompactPCI 3U 8HP 200 WATT 24VDC POWER SUPPLYINPUTAC Input VoltageDC Input VoltageInput Frequency Range18 - 36 VDCOUTPUTInput Inrush Current20A MaxInput Reflected RippleFCC-68 part 15 & EN55022 Class B with the use of an external line filterActive Power Factor CorrectionEfficiency @ 230VAC Full LoadEfficiency @ 115VAC Full LoadEfficiency @ 48/24VDC Full Load82% @ 24VDCInput Line ProtectionNon-User Serviceable FuseHold-up TimeV1/Current +5VDC / 25AV2/Current+3.3VDC / 36AV3/Current+12VDC / 3AV4/Current -12VDC / 0.5ATotal Output Power 200W with 250LFMLine Regulation +/- 0.5%Load RegulationV1&V2 +/- 1%V3&V4 +/- 5%Min. Load RequirementNoOvershoot/Undershoot at Turn-On Less than 1%11 Power SuppliesTurn-On Delay1Sec Max.Initial Setting Accuracy+/- 0.4% for V1 & V2 +/- 2% for V3 & V4Voltage Set point (Internal trim-pot) V1/V2 +/- 5%Ripple @ Noise with 20MHz Bandwidth measured across 10uF Load Capacitor Paralleled with 0.1uF Ceramic Cap.+5VDC60mV p-p+3.3VDC 60mV p-p+/- 12VDC 120mV p-pHot-SwapYesCurrent ShareSingle Wire - on V1 & V2Remote Sense (Open sense lines protected) On +5VDC & +3.3VDCLong Term Stability0.1% over 10 Hours after 10min. Warm UpTransient ResponseFor a step Load of 50%max Load peak transient < 5%. & output Recovers to 1% in Less thanOver-Voltage Protection0.5mSec.110% - 125% of V1,V2 & V3 with Latched Shut DownOverload ProtectionV1 & V2V3V4Short Circuit ProtectionTemperature Protection125% Max.200% Max.250% Max.Available On All OutputsExcess Temp will Shut Down the Unit - with Auto recovery11.08 UK Tel: +44 (0)2380-246900 sales@verotec.co.ukUSA Tel: 603.821.9921 sales@verotec.us

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!