10.07.2015 Views

Download PDF (3.50 Mb) - Verotec

Download PDF (3.50 Mb) - Verotec

Download PDF (3.50 Mb) - Verotec

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CompactPCI 6U 8HP 400 WATT 48VDC POWER SUPPLYFEATURESl 400W output powerl Efficiency - better than 83%l 36-72VDC Nominal Input Voltagel Operation Temp. -5ºC to +55 ºC – No De-ratingl “Hot-Swap” Active Current share on V1 & V2l N+1 Full redundancy operationl No Minimum loading requirementl Standard PICMG® 47Pin Connectorl IEEE 1101.10 compliant form factorl Safety Per UL CSA & CE Markingl Meets FCC-68 Part 15 Class-B & EN-55022 Class-B with externalline filterl I2C Data Bus (optional) for PSU Hardware configurationDescriptionOrdercodeCPCI-DC-6U-400 (Vertical Overlay) 925-4004134CompactPCI 6U 8HP 400 WATT 48VDC POWER SUPPLYINPUTAC Input VoltageDC Input VoltageInput Frequency RangeInput Inrush CurrentInput Reflected RippleActive Power Factor CorrectionEfficiency @ 230VAC Full LoadEfficiency @ 115VAC Full LoadEfficiency @ 48/24VDC Full LoadInput Line Protection36 - 72 VDC20AMax.FCC-68 part 15 & EN55022 Class B with the use of an external line filter83% @ 48VDCNon-User Serviceable Fuse11 Power SuppliesHold-up TimeOUTPUT V1/Current +5VDC /50AV2/Current+3.3VDC / 80AV3/Current +12VDC / 7.5AV4/Current -12VDC / 1.5ATotal Output PowerLine Regulation +/- 0.5%Load RegulationMin. Load Requirement NoV1&V2 +/- 1%V3&V4 +/- 5%Overshoot/Undershoot at Turn-On Less than 1%Turn-On DelayInitial Setting Accuracy400W with 250LFM ( 500W With 400LFM - Safety Pending)1Sec Max.Voltage Set point (Internal trim-pot) V1/V2 +/- 5%+/- 0.4% for V1 & V2 +/- 2% for V3 & V4Ripple @ Noise with 20MHz Bandwidth measured across 10uF Load Capacitor Paralleled with 0.1uF Ceramic Cap.Hot-Swap YesCurrent Share+5VDC+3.3VDCRemote Sense (Open sense lines protected)Long Term StabilityTransient ResponseOver-Voltage ProtectionOverload Protection60mV p-p60mV p-p+/- 12VDC 120mV p-pV1 & V2V3V4Short Circuit Protection Available On All OutputsTemperature ProtectionSingle Wire - on V1 & V2On +5VDC & +3.3VDC0.1% over 10 Hours after 10min. Warm UpFor a step Load of 50%max Load peak transient < 5%. & outputRecovers to 1% in Less than 0.5mSec.110% - 125% of V1,V2 & V3 with Latched Shut Down125% Max.200% Max.250% Max.Excess Temp will Shut Down the Unit - with Auto recovery11.20 UK Tel: +44 (0)2380-246900 sales@verotec.co.ukUSA Tel: 603.821.9921 sales@verotec.us

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!