10.07.2015 Views

Driver Manual FS-8704-14 EtherNet/IP - FieldServer Technologies

Driver Manual FS-8704-14 EtherNet/IP - FieldServer Technologies

Driver Manual FS-8704-14 EtherNet/IP - FieldServer Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>FS</strong>-<strong>8704</strong>-<strong>14</strong> <strong>EtherNet</strong>/<strong>IP</strong> <strong>Manual</strong> Page 13 of 31Example// Server Side NodesNodesNode_NameE<strong>IP</strong>_01, Protocol, <strong>EtherNet</strong>/<strong>IP</strong>6.3 Server Side Map Descriptor6.3.1 <strong>FieldServer</strong> Specific Map Descriptor ParametersColumn Title Function Legal ValuesMap_Descriptor_NameData_Array_NameData_Array_OffsetName of this Map DescriptorName of Data Array where data is to be stored in the<strong>FieldServer</strong>Starting location in Data ArrayFunction Function of Server Map Descriptor PassiveServer_Hold_Timeout*Specifies the length of time that the <strong>FieldServer</strong> willreserve the Server side connection while waiting forthe Client side to update data in Data Array (ifnecessary)Up to 32 alphanumericcharactersOne of the Data Array namesfrom Section 40 to (Data_Array_Length -1)as specified in Section 4.>1.0s6.3.2 Server Specific Map Descriptor Parameters – Unconnected MessagesColumn Title Function Legal ValuesE<strong>IP</strong>_Service The action to be performed. Get_Attrib, Set_AttribE<strong>IP</strong>_ClassE<strong>IP</strong>_AttributeLengthAddressClass to be served.Attribute associated with the class served.Number of data elements to be mapped. If the number of dataelements exceeds the Map Descriptor length, the list of dataelements will be truncated and an error message will be printedonce per Map Descriptor. Refer to Appendix D for furtherinformation.Instance of the class to be served.One of the classessupported by the driver. .Refer to Appendix A.4See particular attributesof each class. Refer toAppendix A.4For any given MapDescriptor there can be200 Floats, 400 Integers or800 BytesDepends on thesupported instances foreach class.<strong>FieldServer</strong> <strong>Technologies</strong> 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.comTel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!