10.07.2015 Views

Driver Manual FS-8704-14 EtherNet/IP - FieldServer Technologies

Driver Manual FS-8704-14 EtherNet/IP - FieldServer Technologies

Driver Manual FS-8704-14 EtherNet/IP - FieldServer Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>FS</strong>-<strong>8704</strong>-<strong>14</strong> <strong>EtherNet</strong>/<strong>IP</strong> <strong>Manual</strong> Page 9 of 31Column Title Function Legal ValuesAddressdata elements exceeds the Map Descriptor length, the list ofdata elements will be truncated and an error message will beprinted once per Map Descriptor. Refer to Appendix D forfurther information.Instance of the class to be polled.there can be 200 Floats, 400Integers or 800 BytesDepends on the supportedinstances for each class.5.3.3 <strong>Driver</strong> Related Map Descriptor Parameters – Data Table Read/Write.Column Title Function Legal ValuesE<strong>IP</strong>_ServiceThe action to be performed.E<strong>IP</strong>_Con_Typ The type of data transfer required. ExplicitE<strong>IP</strong>_Path *E<strong>IP</strong>_Tag_NameE<strong>IP</strong>_Data_Type*LengthE<strong>IP</strong>_Structure_Handle*Used to stipulate the path to the CPU in certain PLC’s.Paths vary and are dependent on the structure of thenetwork.Tag name expressed in PLC program. The data type ofthis parameter is used to set the data format of theData Array if the E<strong>IP</strong>_DATA_TYPE parameter is notspecified.This parameter can be used to specify the data type ofthe tag to match the data type used in the remotedevice. If this parameter is not specified the Data Typeof the Data Array will be used. Refer to Appendix A.4for more information. Alias data types are requiredwhen interacting with PLC’s using RSLogix. Refer toAppendix C.4 for more information.Number of data elements to be mapped. If thenumber of data elements exceeds the Map Descriptorlength, the list of data elements will be truncated andan error message will be printed once per MapDescriptor. See Appendix D for further information.This parameter is required to read/write structures.The driver supports read/write structures havingmembers of same type, i.e. all members are of typeByte, UINT16, UINT32 or Float etcWhen this parameter is defined, the number ofstructure members must be specified as the length ofthe Map Descriptor. Refer to Appendix A.7 for moreinformation.Data_Table_Read,Data_Table_WriteAny space delimitednumerical value. Refer tovendor’sdevicedocumentation. Also seeAppendix A.3, 0 0Maximum length 48characters.Value Alias ( As used in PLC)Float REALUint32 DINTUint16 INTBYTE SINTBIT BOOL & BOOLEAN0 to (Data_Array_Length -1)as specified in Section 4.Any 16bit Integer number(e.g. 59592), 0<strong>FieldServer</strong> <strong>Technologies</strong> 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.comTel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!