10.07.2015 Views

Alféa S - Atlantic-comfort.com

Alféa S - Atlantic-comfort.com

Alféa S - Atlantic-comfort.com

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Split systemLineFunctionSetting rangeor displaySettingincrementBasicsettingDiagnostics heat generation8410 Return temp HP 0... 140 °CSetpoint (return) HP 0... 140 °C8412 Flow temp HP 0... 140 °CSetpoint (flow) HP 0... 140 °C8413 Compressor modulation 0... 100%Diagnostics consumers8700 Outdside temperature -50... 50 °C8701 Outside temp minReset ? (No, Yes)8702 Outside temp maxReset ? (No, Yes)-50... 50 °C-50... 50 °C8740 Room temperature 1 0... 50 °C 20 °CRoom setpoint 1 4... 35 °C 20 °C8743 Flow temperature 1 0... 140 °C 50 °CFlow temperature setpoint 1 0... 140 °C 50 °C8756 Flow temp cooling 1 0... 140 °C 0 °CFlow temp setpoint cooling 1 0... 140 °C 0 °C8770 Room temperature 2 0... 50 °C 20 °CRoom setpoint 2 4... 35 °C 20 °C8773 Flow temperature 2 0... 140 °C 50 °CFlow temperature setpoint 2 0... 140 °C 50 °C8830 DHW (domestic hot water) temperature 0... 140 °CDHW temperature setpoint 5... 80 °C 50 °C8900 Swimming pool temperature 0... 140 °CSwimming pool temperature setpoint 0... 35 °C 22 °C- 14 -Operation manual "1328 - EN"