SuperDuct Four-Wire Duct Smoke Detector - UTCFS Global Security ...
SuperDuct Four-Wire Duct Smoke Detector - UTCFS Global Security ...
SuperDuct Four-Wire Duct Smoke Detector - UTCFS Global Security ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Sensitivity: 0.67 to 2.46 %obscuration/ftReset time: 2 seconds, max.Power up time: 8 seconds, max.Alarm test response time: 5 to 7 secondsController LED indicators: Alarm (red), Trouble (yellow),Power (green)Sensor LED indicators: Alarm (red), Trouble (yellow), Dirty(yellow), Power (green)Alarm initiation relayQuantity: 1Style: Normally openRatings: 2.0 A at 30 Vdc (resistive)Auxiliary relayQuantity: 2Style: Form CRatings: 10 A at 30 Vdc, 10 A at 250 Vac (contacts mustswitch a minimum of 100 mA at 5 Vdc)Supervision (trouble) relayQuantity: 1Style: Form CRatings: 2.0 A at 30 Vdc (resistive)Auxiliary output: 18 Vdc, nom., 30 mA, max.TSD-CO2 module output: 0 to 10 Vdc (0 to 2,000 ppm)Operating environmentTemperature: -20 to 70 °C (-4 to 158 °F)Temperature with TSD-CO2 module installed: 0 to 55 °C(32 to 131 °F)Humidity: 10 to 93%, RH noncondensing at 68 to 72 °C(154.4 to 161.6°F)Operating voltages: 20 to 29 Vdc (-15 to 10%), 24 V (-15 to10%) at 50/60 Hz, 120 V (-15 to 10%) at 50/60 Hz,220/240 V (-15 to 10%) at 50/60 HzOperating currents: See table belowSupply voltage Standby current Alarm currentModelSD-T18SD-T24SD-T36SD-T42SD-T60SD-T78SD-T120SD-RJ5SD-RJ10SD-RJ15SD-RJ20SD-TRM4SD-TRK4SD-MAGSD-TMPSD-VTKSD-GSKTSD-CO2Description18-inch sampling tube24-inch sampling tube36-inch sampling tube42-inch sampling tube60-inch sampling tube78-inch sampling tube120-inch sampling tubeRJ-45 wiring harness kit, 5.0 ftRJ-45 wiring harness kit, 10.0 ftRJ-45 wiring harness kit, 15.0 ftRJ-45 wiring harness kit, 20.0 ft.Remote test-reset station, magneticRemote test-reset station, keyedTest magnet kitSampling tube mounting plateAir velocity test kitCover gasket kitCarbon dioxide (CO 2 ) sensor moduleNote: The TSD-CO2 module has not been performanceevaluated to UL 2075 or approved by ULC.Operation24 Vdc 77.9 mA 124.3 mA24 V at 50 Hz 215.3 mA 307.0 mA24 V at 60 Hz 220.0 mA 316.5 mA120 V at 50 Hz 91.0 mA 89.0 mA120 V at 60 Hz 79.0 mA 74.0 mA220/240 V at 50 Hz 44.9 mA 44.0 mA220/240 V at 60 Hz 34.0 mA 32.0 mANote: The TSD-CO2 module has not been performanceevaluated to UL 2075 or approved by ULC.Controller controls and indicatorsAlarmTroublePowerTest/resetswitchAccessoriesThe accessories that you can use with the duct smoke detectorare listed in the table below.Figure 4: Controller controls and indicatorsThe controls and indicators on the four-wire controller (seeFigure 4) are described in the table below.ModelSD-T8Description8-inch sampling tubeTechnical Bulletin<strong>Super<strong>Duct</strong></strong> <strong>Four</strong>-<strong>Wire</strong> <strong>Duct</strong> <strong>Smoke</strong> <strong>Detector</strong> 5